Cell · Sep 2024
Hao Chang, Matthew H. Perkins, Leonardo S. Novaes, … Ivan E. de Araujo
Abstract
Negative psychological states impact immunity by altering the gut microbiome. However, the relationship between brain states and microbiome composition remains unclear. We show that Brunner's glands in the duodenum couple stress-sensitive brain circuits to bacterial homeostasis. Brunner's glands mediated the enrichment of gut Lactobacillus species in response to vagus nerve stimulation. Cell-specific ablation of the glands markedly suppressed Lactobacilli counts and heightened vulnerability to infection. In the forebrain, we mapped a vagally mediated, polysynaptic circuit connecting the central nucleus of the amygdala to Brunner's glands. Chronic stress suppressed central amygdala activity and phenocopied the effects of gland lesions. Conversely, excitation of either the central amygdala or parasympathetic vagal neurons activated Brunner's glands and reversed the effects of stress on the gut microbiome and immunity. The findings revealed a tractable brain-body mechanism linking psychological states to host defense.
Advanced Science · Aug 2024
Xue Wang, Lei Xu, Yu Meng, … Haibo Wang
Abstract
Mammalian cochlea spiral ganglion neurons (SGNs) are crucial for sound transmission, they can be damaged by chemotherapy drug cisplatin and lead to irreversible sensorineural hearing loss (SNHL), while such damage can also render cochlear implants ineffective. However, the mechanisms underlying cisplatin‐induced SGNs damage and subsequent SNHL are still under debate and there is no currently effective clinical treatment. Here, this study demonstrates that ferroptosis is triggered in SGNs following exposure to cisplatin. Inhibiting ferroptosis protects against cisplatin‐induced SGNs damage and hearing loss, while inducing ferroptosis intensifies these effects. Furthermore, cisplatin prompts nuclear receptor coactivator 4 (NCOA4)‐mediated ferritinophagy in SGNs, while knocking down NCOA4 mitigates cisplatin‐induced ferroptosis and hearing loss. Notably, the upstream regulator of NCOA4 is identified and transcription factor forkhead box O1 (FOXO1) is shown to directly suppress NCOA4 expression in SGNs. The knocking down of FOXO1 amplifies NCOA4‐mediated ferritinophagy, increases ferroptosis and lipid peroxidation, while disrupting the interaction between FOXO1 and NCOA4 in NCOA4 knock out mice prevents the cisplatin‐induced SGN ferroptosis and hearing loss. Collectively, this study highlights the critical role of the FOXO1‐NCOA4 axis in regulating ferritinophagy and ferroptosis in cisplatin‐induced SGNs damage, offering promising therapeutic targets for SNHL mitigation.
Drug Delivery · Aug 2024
Chunjiang Wei, Ziwen Gao, Martina Knabel, … Verena Scheper
Abstract
Background: There exists an unfulfilled requirement for effective cochlear pharmacotherapy. Controlled local drug delivery could lead to effective bioavailability. The round window niche (RWN), a cavity in the middle ear, is connected to the cochlea via a membrane through which drug can diffuse. We are developing individualized drug-eluting RWN implants (RNIs). To test their effectiveness in guinea pigs, a commonly used model in cochlear pharmacology studies, it is first necessary to develop guinea pig RNIs (GP-RNI). Methods: Since guinea pigs do not have a RWN such as it is present in humans and to reduce the variables in in vivo studies, a one-size-fits-all GP-RNI model was designed using 12 data sets of Dunkin-Hartley guinea pigs. The model was 3D-printed using silicone. The accuracy and precision of printing, distribution of the sample ingredient dexamethasone (DEX), biocompatibility, bio-efficacy, implantability and drug release were tested in vitro. The GP-RNI efficacy was validated in cochlear implant-traumatized guinea pigs in vivo. Results: The 3D-printed GP-RNI was precise, accurate and fitted in all tested guinea pig RWNs. DEX was homogeneously included in the silicone. The GP-RNI containing 1% DEX was biocompatible, bio-effective and showed a two-phase and sustained DEX release in vitro, while it reduced fibrous tissue growth around the cochlear implant in vivo. Conclusions: We developed a GP-RNI that can be used for precise inner ear drug delivery in guinea pigs, providing a reliable platform for testing the RNI's safety and efficacy, with potential implications for future clinical translation.
Cognitive, Affective, & Behavioral Neuroscience · Aug 2024
M. F. Koloski, S. Hulyalkar, S. A. Barnes, … D. S. Ramanathan
Abstract
The value associated with reward is sensitive to external factors, such as the time between the choice and reward delivery as classically manipulated in temporal discounting tasks. Subjective preference for two reward options is dependent on objective variables of reward magnitude and reward delay. Single neuron correlates of reward value have been observed in regions, including ventral striatum, orbital, and medial prefrontal cortex. Brain imaging studies show cortico-striatal-limbic network activity related to subjective preferences. To explore how oscillatory dynamics represent reward processing across brain regions, we measured local field potentials of rats performing a temporal discounting task. Our goal was to use a data-driven approach to identify an electrophysiological marker that correlates with reward preference. We found that reward-locked oscillations at beta frequencies signaled the magnitude of reward and decayed with longer temporal delays. Electrodes in orbitofrontal/medial prefrontal cortex, anterior insula, ventral striatum, and amygdala individually increased power and were functionally connected at beta frequencies during reward outcome. Beta power during reward outcome correlated with subjective value as defined by a computational model fit to the discounting behavior. These data suggest that cortico-striatal beta oscillations are a reward signal correlated, which may represent subjective value and hold potential to serve as a biomarker and potential therapeutic target.
Bioelectronic Medicine · Jul 2024
Danny V. Lam, Justin Chin, Meagan K. Brucker-Hahn, … Igor Lavrov
Abstract
Background Spinal cord stimulation (SCS) has demonstrated multiple benefits in treating chronic pain and other clinical disorders related to sensorimotor dysfunctions. However, the underlying mechanisms are still not fully understood, including how electrode placement in relation to the spinal cord neuroanatomy influences epidural spinal recordings (ESRs). To characterize this relationship, this study utilized stimulation applied at various anatomical sections of the spinal column, including at levels of the intervertebral disc and regions correlating to the dorsal root entry zone. Method Two electrode arrays were surgically implanted into the dorsal epidural space of the swine. The stimulation leads were positioned such that the caudal-most electrode contact was at the level of a thoracic intervertebral segment. Intraoperative cone beam computed tomography (CBCT) images were utilized to precisely determine the location of the epidural leads relative to the spinal column. High-resolution microCT imaging and 3D-model reconstructions of the explanted spinal cord illustrated precise positioning and dimensions of the epidural leads in relation to the surrounding neuroanatomy, including the spinal rootlets of the dorsal and ventral columns of the spinal cord. In a separate swine cohort, implanted epidural leads were used for SCS and recording evoked ESRs. Results Reconstructed 3D-models of the swine spinal cord with epidural lead implants demonstrated considerable distinctions in the dimensions of a single electrode contact on a standard industry epidural stimulation lead compared to dorsal rootlets at the dorsal root entry zone (DREZ). At the intervertebral segment, it was observed that a single electrode contact may cover 20-25% of the DREZ if positioned laterally. Electrode contacts were estimated to be ~0.75 mm from the margins of the DREZ when placed at the midline. Furthermore, ventral rootlets were observed to travel in proximity and parallel to dorsal rootlets at this level prior to separation into their respective sides of the spinal cord. Cathodic stimulation at the level of the intervertebral disc, compared to an ‘off-disc’ stimulation (7 mm rostral), demonstrated considerable variations in the features of recorded ESRs, such as amplitude and shape, and evoked unintended motor activation at lower stimulation thresholds. This substantial change may be due to the influence of nearby ventral roots. To further illustrate the influence of rootlet activation vs. dorsal column activation, the stimulation lead was displaced laterally at ~2.88 mm from the midline, resulting in variances in both evoked compound action potential (ECAP) components and electromyography (EMG) components in ESRs at lower stimulation thresholds. Conclusion The results of this study suggest that the ECAP and EMG components of recorded ESRs can vary depending on small differences in the location of the stimulating electrodes within the spinal anatomy, such as at the level of the intervertebral segment. Furthermore, the effects of sub-centimeter lateral displacement of the stimulation lead from the midline, leading to significant changes in electrophysiological metrics. The results of this pilot study reveal the importance of the small displacement of the electrodes that can cause significant changes to evoked responses SCS. These results may provide further valuable insights into the underlying mechanisms and assist in optimizing future SCS-related applications.
2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2024
Qiwei Dong, Cynthia Ezeh, Yupeng Wu, … Kevin J. Otto
Abstract
The overall focus of this research program is to investigate the viability and safety of microelectrode arrays (MEAs) and ultramicroelectrode arrays (UMEAs) for microstimulation (µStim) in the brain. We aim to assess their potential to deliver adequate electrical stimulation for neural activation without causing electrode or tissue damage. To this end, here we conducted galvanostatic Electrochemical Impedance Spectroscopy (EIS) to assess the behavior of electrodes of various diameters both pre- and post-stimulation in a rat model. Our first-generation electrode arrays (G1) were designed with electrode diameters spanning 3 orders of magnitude and including subcellular dimensions. Using these devices, we delivered 0.4 nC/phase stimulation in vivo. We conducted in vitro EIS measurements before and after the current pulsing. Our findings show that these electrode arrays, including UMEAs, exhibit stable electrochemical behavior following a 0.4 nC/phase current pulse. To validate the EIS frequency range used for the G1 measurements, we designed a second-generation electrode array (G2) that included a terminating lead and a looping lead. This array provided the ability to assess the accuracy contour plot of our EIS system and electrode array platform. This exploratory research contributes to the ongoing knowledge of UMEAs in µStim applications. These developments may result in high-fidelity, non-damaging multichannel µStim, and improved neuromodulation technology for the treatment of neural diseases and injuries.
Ear & Hearing · Jul 2024
Lina A. J. Reiss, Melissa B. Lawrence, Irina A. Omelchenko, … Jonathon R. Kirk
Abstract
Objectives: Electro-acoustic stimulation (EAS) combines electric stimulation via a cochlear implant (CI) with residual low-frequency acoustic hearing, with benefits for music appreciation and speech perception in noise. However, many EAS CI users lose residual acoustic hearing, reducing this benefit. The main objectives of this study were to determine whether chronic EAS leads to more hearing loss compared with CI surgery alone in an aged guinea pig model, and to assess the relationship of any hearing loss to histology measures. Conversely, it is also important to understand factors impacting efficacy of electric stimulation. If one contributor to CI-induced hearing loss is damage to the auditory nerve, both acoustic and electric thresholds will be affected. Excitotoxicity from EAS may also affect electric thresholds, while electric stimulation is osteogenic and may increase electrode impedances. Hence, secondary objectives were to assess how electric thresholds are related to the amount of residual hearing loss after CI surgery, and how EAS affects electric thresholds and impedances over time. Design: Two groups of guinea pigs, aged 9 to 21 months, were implanted with a CI in the left ear. Preoperatively, the animals had a range of hearing losses, as expected for an aged cohort. At 4 weeks after surgery, the EAS group (n = 5) received chronic EAS for 8 hours a day, 5 days a week, for 20 weeks via a tether system that allowed for free movement during stimulation. The nonstimulated group (NS; n = 6) received no EAS over the same timeframe. Auditory brainstem responses (ABRs) and electrically evoked ABRs (EABRs) were recorded at 3 to 4 week intervals to assess changes in acoustic and electric thresholds over time. At 24 weeks after surgery, cochlear tissue was harvested for histological evaluation, only analyzing animals without electrode extrusions (n = 4 per ear). Results: Cochlear implantation led to an immediate worsening of ABR thresholds peaking between 3 and 5 weeks after surgery and then recovering and stabilizing by 5 and 8 weeks. Significantly greater ABR threshold shifts were seen in the implanted ears compared with contralateral, non-implanted control ears after surgery. After EAS and termination, no significant additional ABR threshold shifts were seen in the EAS group compared with the NS group. A surprising finding was that NS animals had significantly greater recovery in EABR thresholds over time, with decreases (improvements) of −51.8 ± 33.0 and −39.0 ± 37.3 c.u. at 12 and 24 weeks, respectively, compared with EAS animals with EABR threshold increases (worsening) of +1.0 ± 25.6 and 12.8 ± 44.3 c.u. at 12 and 24 weeks. Impedance changes over time did not differ significantly between groups. After exclusion of cases with electrode extrusion or significant trauma, no significant correlations were seen between ABR and EABR thresholds, or between ABR thresholds with histology measures of inner/outer hair cell counts, synaptic ribbon counts, stria vascularis capillary diameters, or spiral ganglion cell density. Conclusions: The findings do not indicate that EAS significantly disrupts acoustic hearing, although the small sample size limits this interpretation. No evidence of associations between hair cell, synaptic ribbon, spiral ganglion cell, or stria vascularis with hearing loss after cochlear implantation was seen when surgical trauma is minimized. In cases of major trauma, both acoustic thresholds and electric thresholds were elevated, which may explain why CI-only outcomes are often better when trauma and hearing loss are minimized. Surprisingly, chronic EAS (or electric stimulation alone) may negatively impact electric thresholds, possibly by prevention of recovery of the auditory nerve after CI surgery. More research is needed to confirm the potentially negative impact of chronic EAS on electric threshold recovery.
Nature Communications · Jul 2024
Byungkook Oh, Seunghyeok Baek, Kum Seok Nam, … Steve Park
Abstract
3D printing has been widely used for on-demand prototyping of complex three-dimensional structures. In biomedical applications, PEDOT:PSS has emerged as a promising material in versatile bioelectronics due to its tissue-like mechanical properties and suitable electrical properties. However, previously developed PEDOT:PSS inks have not been able to fully utilize the advantages of commercial 3D printing due to its long post treatment times, difficulty in high aspect ratio printing, and low conductivity. We propose a one-shot strategy for the fabrication of PEDOT:PSS ink that is able to simultaneously achieve on-demand biocompatibility (no post treatment), structural integrity during 3D printing for tall three-dimensional structures, and high conductivity for rapid-prototyping. By using ionic liquid-facilitated PEDOT:PSS colloidal stacking induced by a centrifugal protocol, a viscoplastic PEDOT:PSS-ionic liquid colloidal (PILC) ink was developed. PILC inks exhibit high-aspect ratio vertical stacking, omnidirectional printability for generating suspended architectures, high conductivity (~286 S/cm), and high-resolution printing (~50 µm). We demonstrate the on-demand and versatile applicability of PILC inks through the fabrication of 3D circuit boards, on-skin physiological signal monitoring e-tattoos, and implantable bioelectronics (opto-electrocorticography recording, low voltage sciatic nerve stimulation and recording from deeper brain layers via 3D vertical spike arrays).
Scientific Reports · Jul 2024
Daniel Song, Matthew C. Tresch
Abstract
Although epidural spinal cord and muscle stimulation have each been separately used for restoration of movement after spinal cord injury, their combined use has not been widely explored. Using both approaches in combination could provide more flexible control compared to using either approach alone, but whether responses evoked from such combined stimulation can be easily predicted is unknown. We evaluate whether responses evoked by combined spinal and muscle stimulation can be predicted simply, as the linear summation of responses produced by each type of stimulation individually. Should this be true, it would simplify the prediction of co-stimulation responses and the development of control schemes for spinal cord injury rehabilitation. In healthy anesthetized rats, we measured hindlimb isometric forces in response to spinal and muscle stimulation. Force prediction errors were calculated as the difference between predicted and observed co-stimulation forces. We found that spinal and muscle co-stimulation could be closely predicted as the linear summation of the individual spinal and muscle responses and that the errors were relatively low. We discuss the implications of these results to the use of combined muscle and spinal stimulation for the restoration of movement following spinal cord injury.
Bioelectronic Medicine · Jul 2024
Fangqi Liu, Maryam Habibollahi, Yu Wu, … Andreas Demosthenous
Abstract
Background Implantable vagus nerve stimulation is a promising approach for restoring autonomic cardiovascular functions after heart transplantation. For successful treatment a system should have multiple electrodes to deliver precise stimulation and complex neuromodulation patterns. Methods This paper presents an implantable multi-channel stimulation system for vagal-cardiac neuromodulation studies in swine species. The system comprises an active electrode array implant percutaneously connected to an external wearable controller. The active electrode array implant has an integrated stimulator ASIC mounted on a ceramic substrate connected to an intraneural electrode array via micro-rivet bonding. The implant is silicone encapsulated for biocompatibility and implanted lifetime. The stimulation parameters are remotely transmitted via a Bluetooth telemetry link. Results The size of the encapsulated active electrode array implant is 8 mm × 10 mm × 3 mm. The stimulator ASIC has 10-bit current amplitude resolution and 16 independent output channels, each capable of delivering up to 550 µA stimulus current and a maximum voltage of 20 V. The active electrode array implant was subjected to in vitro accelerated lifetime testing at 70 °C for 7 days with no degradation in performance. After over 2 h continuous stimulation, the surface temperature change of the implant was less than 0.5 °C. In addition, in vivo testing on the sciatic nerve of a male Göttingen minipig demonstrated that the implant could effectively elicit an EMG response that grew progressively stronger on increasing the amplitude of the stimulation. Conclusions The multi-channel stimulator is suitable for long term implantation. It shows potential as a useful tool in vagal-cardiac neuromodulation studies in animal models for restoring autonomic cardiovascular functions after heart transplantation.
Current Neuropharmacology · Jul 2024
Nicolas Vautrelle, Véronique Coizet, Mariana Leriche, … John N.J. Reynolds
Abstract
Background: Regional changes in corticostriatal transmission induced by phasic dopaminergic signals are an essential feature of the neural network responsible for instrumental reinforcement during discovery of an action. However, the timing of signals that are thought to contribute to the induction of corticostriatal plasticity is difficult to reconcile within the framework of behavioural reinforcement learning, because the reinforcer is normally delayed relative to the selection and execution of causally-related actions. Objective: While recent studies have started to address the relevance of delayed reinforcement signals and their impact on corticostriatal processing, our objective was to establish a model in which a sensory reinforcer triggers appropriately delayed reinforcement signals relayed to the striatum via intact neuronal pathways and to investigate the effects on corticostriatal plasticity. Methods: We measured corticostriatal plasticity with electrophysiological recordings using a light flash as a natural sensory reinforcer, and pharmacological manipulations were applied in an in vivo anesthetized rat model preparation. Results: We demonstrate that the spiking of striatal neurons evoked by single-pulse stimulation of the motor cortex can be potentiated by a natural sensory reinforcer, operating through intact afferent pathways, with signal timing approximating that required for behavioural reinforcement. The pharmacological blockade of dopamine receptors attenuated the observed potentiation of corticostriatal neurotransmission. Conclusion: This novel in vivo model of corticostriatal plasticity offers a behaviourally relevant framework to address the physiological, anatomical, cellular, and molecular bases of instrumental reinforcement learning.
Scientific Reports · Jun 2024
Min Young Lee, Seo-Kyung Jung, Jongmoon Jang, … Jeong Hun Jang
Abstract
In individuals with hearing loss, protection of residual hearing is essential following cochlear implantation to facilitate acoustic and electric hearing. Hearing preservation requires slow insertion, atraumatic electrode and delivery of the optimal quantity of a pharmacological agent. Several studies have reported variable hearing outcomes with osmotic pump-mediated steroid delivery. New drugs, such as sialyllactose (SL) which have anti-inflammatory effect in many body parts, can prevent tissue overgrowth. In the present study, the positive effects of the pharmacological agent SL against insults were evaluated in vitro using HEI-OC1 cells. An animal model to simulate the damage due to electrode insertion during cochlear implantation was used. SL was delivered using osmotic pumps to prevent loss of the residual hearing in this animal model. Hearing deterioration, tissue fibrosis and ossification were confirmed in this animal model. Increased gene expressions of inflammatory cytokines were identified in the cochleae following dummy electrode insertion. Following the administration of SL, insertion led to a decrease in hearing threshold shifts, tissue reactions, and inflammatory markers. These results emphasize the possible role of SL in hearing preservation and improve our understanding of the mechanism underlying hearing loss after cochlear implantation.
Current Biology · Jun 2024
Gregg A. Castellucci, Christopher K. Kovach, Farhad Tabasi, … Michael A. Long
Abstract
Turn-taking is a central feature of conversation across languages and cultures.1,2,3,4 This key social behavior requires numerous sensorimotor and cognitive operations1,5,6 that can be organized into three general phases: comprehension of a partner's turn, preparation of a speaker's own turn, and execution of that turn. Using intracranial electrocorticography, we recently demonstrated that neural activity related to these phases is functionally distinct during turn-taking.7 In particular, networks active during the perceptual and articulatory stages of turn-taking consisted of structures known to be important for speech-related sensory and motor processing,8,9,10,11,12,13,14,15,16,17 while putative planning dynamics were most regularly observed in the caudal inferior frontal gyrus (cIFG) and the middle frontal gyrus (cMFG). To test if these structures are necessary for planning during spoken interaction, we used direct electrical stimulation (DES) to transiently perturb cortical function in neurosurgical patient-volunteers performing a question-answer task.7,18,19 We found that stimulating the cIFG and cMFG led to various response errors9,13,20,21 but not gross articulatory deficits, which instead resulted from DES of structures involved in motor control8,13,20,22 (e.g., the precentral gyrus). Furthermore, perturbation of the cIFG and cMFG delayed inter-speaker timing-consistent with slowed planning-while faster responses could result from stimulation of sites located in other areas. Taken together, our findings suggest that the cIFG and cMFG contain critical preparatory circuits that are relevant for interactive language use.
Frontiers in Molecular Neuroscience · May 2024
Benjamin M. Gansemer, Muhammad T. Rahman, Zhenshen Zhang, Steven H. Green
Abstract
Spiral ganglion neurons (SGNs) transmit auditory information from cochlear hair cells to the brain. SGNs are thus not only important for normal hearing, but also for effective functioning of cochlear implants, which stimulate SGNs when hair cells are missing. SGNs slowly degenerate following aminoglycoside-induced hair cell loss, a process thought to involve an immune response. However, the specific immune response pathways involved remain unknown. We used RNAseq to gain a deeper understanding immune-related and other transcriptomic changes that occur in the rat spiral ganglion after kanamycin-induced deafening. Among the immune and inflammatory genes that were selectively upregulated in deafened spiral ganglia, the complement cascade genes were prominent. We then assessed SGN survival, as well as immune cell numbers and activation, in the spiral ganglia of rats with a CRISPR-Cas9-mediated knockout of complement component 3 (C3). Similar to previous findings in our lab and other deafened rodent models, we observed an increase in macrophage number and increased expression of CD68, a marker of phagocytic activity and cell activation, in macrophages in the deafened ganglia. Moreover, we found an increase in MHCII expression on spiral ganglion macrophages and an increase in lymphocyte number in the deafened ganglia, suggestive of an adaptive immune response. However, C3 knockout did not affect SGN survival or increase in macrophage number/activation, implying that complement activation does not play a role in SGN death after deafening. Together, these data suggest that both innate and adaptive immune responses are activated in the deafened spiral ganglion, with the adaptive response directly contributing to cochlear neurodegeneration.
bioRxiv · May 2024
Ashlesha Deshmukh, Megan L Settell, Kevin L Cheng, … Kip Ludwig
Abstract
Introduction: Evoked compound action potentials (ECAPs) measured using epidural spinal recordings (ESRs) during epidural spinal cord stimulation (SCS) can help elucidate fundamental mechanisms for the treatment of pain, as well as inform closed-loop control of SCS. Previous studies have used ECAPs to characterize the neural response to various neuromodulation therapies and have demonstrated that ECAPs are highly prone to multiple sources of artifact, including post-stimulus pulse capacitive artifact, electromyography (EMG) bleed-through, and motion artifact resulting from disturbance of the electrode/tissue interface during normal behavior. However, a thorough characterization has yet to be performed for how these sources of artifact may contaminate recordings within the temporal window commonly used to determine activation of A-beta fibers in a large animal model. Methods: We characterized the sources of artifacts that can contaminate the recording of ECAPs in an epidural SCS swine model using the Abbott Octrode™ lead. Muscle paralytics were administered to block muscle activation preventing EMG from contaminating the recorded ECAPs. Concurrent EMG recordings of the longissimus, a long muscle of the back, were used to confirm a 2-4 millisecond (ms) latency source of EMG bleed-through that frequently contaminated the A-beta temporal window. Additionally, we obtained recordings approximately 5-10 minutes post-mortem after clear evoked A-beta and associated EMG responses ceased to characterize the representation of stimulation artifact across the array. Results: Spinal ECAP recordings can be contaminated by capacitive artifact, short latency EMG from nearby long muscles of the back, and motion artifact from multiple sources. In many cases, the capacitive artifact can appear nearly identical in duration and waveshape to evoked A-beta responses. These sources of EMG can have phase shifts across the electrode array, very similar to the phase shift anticipated by propagation of an evoked A-beta fiber response across the array. This short latency EMG is often evident at currents similar to those needed to activate A-beta fibers associated with the treatment of pain. Changes in cerebrospinal fluid between the cord and dura, and motion induced during breathing created a cyclic oscillation in all evoked components of the recorded ECAP signal. Conclusion: Careful controls must be implemented to accurately separate neural signal from the sources of artifact in spinal cord ECAPs. To address this, we suggest experimental procedures and associated reporting requirements necessary to disambiguate the underlying neural response from these confounds. These data are important to better understand the conceptual framework for recorded ESRs, with components such as ECAPs, EMG responses and artifacts, and have important implications for closed-loop control algorithms to account for transient motion such as postural changes and cough.
Scientific Reports · May 2024
Yoshiki Matsuda, Nobuyuki Ozawa, Takiko Shinozaki, … Toshikazu Shinba
Abstract
Anticipating positive outcomes is a core cognitive function in the process of reward prediction. However, no neurophysiological method objectively assesses reward prediction in basic medical research. In the present study, we established a physiological paradigm using cortical direct current (DC) potential responses in rats to assess reward prediction. This paradigm consisted of five daily 1-h sessions with two tones, wherein the rewarded tone was followed by electrical stimulation of the medial forebrain bundle (MFB) scheduled at 1000 ms later, whereas the unrewarded tone was not. On day 1, both tones induced a negative DC shift immediately after auditory responses, persisting up to MFB stimulation. This negative shift progressively increased and peaked on day 4. Starting from day 3, the negative shift from 600 to 1000 ms was significantly larger following the rewarded tone than that following the unrewarded tone. This negative DC shift was particularly prominent in the frontal cortex, suggesting its crucial role in discriminative reward prediction. During the extinction sessions, the shift diminished significantly on extinction day 1. These findings suggest that cortical DC potential is related to reward prediction and could be a valuable tool for evaluating animal models of depression, providing a testing system for anhedonia.
PeerJ · Apr 2024
Hongmei Hu, Stephan D. Ewert, Birger Kollmeier, Deborah Vickers
Abstract
Advancements in cochlear implants (CIs) have led to a significant increase in bilateral CI users, especially among children. Yet, most bilateral CI users do not fully achieve the intended binaural benefit due to potential limitations in signal processing and/or surgical implant positioning. One crucial auditory cue that normal hearing (NH) listeners can benefit from is the interaural time difference (ITD), i.e ., the time difference between the arrival of a sound at two ears. The ITD sensitivity is thought to be heavily relying on the effective utilization of temporal fine structure (very rapid oscillations in sound). Unfortunately, most current CIs do not transmit such true fine structure. Nevertheless, bilateral CI users have demonstrated sensitivity to ITD cues delivered through envelope or interaural pulse time differences, i.e ., the time gap between the pulses delivered to the two implants. However, their ITD sensitivity is significantly poorer compared to NH individuals, and it further degrades at higher CI stimulation rates, especially when the rate exceeds 300 pulse per second. The overall purpose of this research thread is to improve spatial hearing abilities in bilateral CI users. This study aims to develop electroencephalography (EEG) paradigms that can be used with clinical settings to assess and optimize the delivery of ITD cues, which are crucial for spatial hearing in everyday life. The research objective of this article was to determine the effect of CI stimulation pulse rate on the ITD sensitivity, and to characterize the rate-dependent degradation in ITD perception using EEG measures. To develop protocols for bilateral CI studies, EEG responses were obtained from NH listeners using sinusoidal-amplitude-modulated (SAM) tones and filtered clicks with changes in either fine structure ITD (ITD FS ) or envelope ITD (ITD ENV ). Multiple EEG responses were analyzed, which included the subcortical auditory steady-state responses (ASSRs) and cortical auditory evoked potentials (CAEPs) elicited by stimuli onset, offset, and changes. Results indicated that acoustic change complex (ACC) responses elicited by ITD ENV changes were significantly smaller or absent compared to those elicited by ITD FS changes. The ACC morphologies evoked by ITD FS changes were similar to onset and offset CAEPs, although the peak latencies were longest for ACC responses and shortest for offset CAEPs. The high-frequency stimuli clearly elicited subcortical ASSRs, but smaller than those evoked by lower carrier frequency SAM tones. The 40-Hz ASSRs decreased with increasing carrier frequencies. Filtered clicks elicited larger ASSRs compared to high-frequency SAM tones, with the order being 40 > 160 > 80> 320 Hz ASSR for both stimulus types. Wavelet analysis revealed a clear interaction between detectable transient CAEPs and 40-Hz ASSRs in the time-frequency domain for SAM tones with a low carrier frequency.
medRxiv · Apr 2024
Sumiko Abe, Jessica Vidmark, Estefania Hernandez-Martin, … Terence D. Sanger
Abstract
Objective This study investigated the relationship between DBS evoked potentials (EPs) and diffusion tensor imaging (DTI) in a group of patients with dystonia who underwent DBS treatment. EPs and DTI are both useful methods for studying neural connectivity in the brain but measure different aspects of brain function. EPs provide information on electrical connectivity, while DTI provides information on anatomical pathways connecting regions. Methods This study focused on the pallidum and motor thalamus nuclei, which are common targets for DBS in dystonia. Prior to DBS implantation, DTI images were acquired for each patient, and were processed to obtain DTI coefficients such as length (L), volume (V), and fractional anisotropy (FA) of the fiber tracts. The relationship between the fiber tracts and electrophysiology was examined using a generalized linear model (GLM). Results We showed that the amplitude of EPs correlated with FA and tract volume, while delay correlated with tract length. These findings suggest that DBS signals travel across tracts to affect both local and distant brain regions, and the magnitude of the effect of DBS is determined by the integrity of the white matter tract, while DBS signal delay is affected by the tract length. Our results further suggest that the magnitude and delay of the spread of the DBS signal may be predicted by the DTI connectivity. This provides strong supporting evidence for other studies that have assumed, but have been unable to test, such a relationship. Conclusion Overall, this study suggests that the electrical effects of DBS can be at least partially predicted by noninvasive DTI imaging in patients with dystonia. By combining EPs with DTI, we could investigate the propagation of stimulation pulses through brain regions. While this relationship has been previously hypothesized by the neuroscience community, this is the first study in humans to demonstrate this relationship between DBS EPs and DTI, thereby advancing the field of human brain mapping and enhancing the precision of neurosurgical targeting.
The Journal of Neuroscience · Apr 2024
Ali Falaki, Stephan Quessy, Numa Dancause
Abstract
Hand movements are associated with modulations of neuronal activity across several interconnected cortical areas, including the primary motor cortex (M1) and the dorsal and ventral premotor cortices (PMd and PMv). Local field potentials (LFPs) provide a link between neuronal discharges and synaptic inputs. Our current understanding of how LFPs vary in M1, PMd, and PMv during contralateral and ipsilateral movements is incomplete. To help reveal unique features in the pattern of modulations, we simultaneously recorded LFPs in these areas in two macaque monkeys performing reach and grasp movements with either the right or left hand. The greatest effector-dependent differences were seen in M1, at low (≤13 Hz) and γ frequencies. In premotor areas, differences related to hand use were only present in low frequencies. PMv exhibited the greatest increase in low frequencies during instruction cues and the smallest effector-dependent modulation during movement execution. In PMd, δ oscillations were greater during contralateral reach and grasp, and β activity increased during contralateral grasp. In contrast, β oscillations decreased in M1 and PMv. These results suggest that while M1 primarily exhibits effector-specific LFP activity, premotor areas compute more effector-independent aspects of the task requirements, particularly during movement preparation for PMv and production for PMd. The generation of precise hand movements likely relies on the combination of complementary information contained in the unique pattern of neural modulations contained in each cortical area. Accordingly, integrating LFPs from premotor areas and M1 could enhance the performance and robustness of brain-machine interfaces.
iScience · Apr 2024
Alan M. Carroll, Jonathan R. Riley, Michael S. Borland, … Crystal T. Engineer
Abstract
Hearing loss can lead to long-lasting effects on the central nervous system, and current therapies, such as auditory training and rehabilitation, show mixed success in improving perception and speech comprehension. Vagus nerve stimulation (VNS) is an adjunctive therapy that can be paired with rehabilitation to facilitate behavioral recovery after neural injury. However, VNS for auditory recovery has not been tested after severe hearing loss or significant damage to peripheral receptors. This study investigated the utility of pairing VNS with passive or active auditory rehabilitation in a rat model of noise-induced hearing loss. Although auditory rehabilitation helped rats improve their frequency discrimination, learn novel speech discrimination tasks, and achieve speech-in-noise performance similar to normal hearing controls, VNS did not enhance recovery of speech sound perception. These results highlight the limitations of VNS as an adjunctive therapy for hearing loss rehabilitation and suggest that optimal benefits from neuromodulation may require restored peripheral signaling.