Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

742 papers

eneuro · Jan 2025

Cortical HFS-Induced Neo-Hebbian Local Plasticity Enhances Efferent Output Signal and Strengthens Afferent Input Connectivity (opens in a new tab)

Xiao Li, Xue Wang, Xiaohan Hu, … Jufang He

Abstract

High-frequency stimulation (HFS)-induced long–term potentiation (LTP) is generally regarded as a homosynaptic Hebbian-type LTP, where synaptic changes are thought to occur at the synapses that project from the stimulation site and terminate onto the neurons at the recording site. In this study, we first investigated HFS-induced LTP on urethane-anesthetized rats and found that cortical HFS enhances neural responses at the recording site through the strengthening of local connectivity with nearby neurons at the stimulation site rather than through synaptic strengthening at the recording site. This enhanced local connectivity at the stimulation site leads to increased output propagation, resulting in signal potentiation at the recording site. Additionally, we discovered that HFS can also nonspecifically strengthen distant afferent synapses at the HFS site, thereby expanding its impact beyond local neural connections. This form of plasticity exhibits a neo-Hebbian characteristic as it exclusively manifests in the presence of cholecystokinin release, induced by HFS. The cortical HFS-induced local LTP was further supported by a behavioral task, providing additional evidence. Our results unveil a previously overlooked mechanism underlying cortical plasticity: synaptic plasticity is more likely to occur around the soma site of strongly activated cortical neurons rather than solely at their projection terminals.

Advanced Science · Jan 2025

Reversing Cochlear Nucleus Maladaptive Plasticity via Customized Extracochlear Stimulation: A New Approach for Tinnitus Treatment (opens in a new tab)

Min Chen, Shuwen Fan, Jiabao Mao, … Shufeng Li

Abstract

Tinnitus, a widespread condition affecting numerous individuals worldwide, remains a significant challenge due to limited effective therapeutic interventions. Intriguingly, patients using cochlear implants (CIs) have reported significant relief from tinnitus symptoms, although the underlying mechanisms remain unclear and intracochlear implantation risks cochlear damage and hearing loss. This study demonstrates that targeted intracochlear electrical stimulation (ES) in guinea pigs with noise‐induced hearing loss reversed tinnitus‐related maladaptive plasticity in the cochlear nucleus (CN), characterized by reduced auditory innervation, increased somatosensory innervation, and diminished inhibitory neural networks. Additionally, a customized extracochlear ES delivered by a newly designed extracochlear electrode array to guinea pigs with salicylate‐induced tinnitus also reversed the aforementioned maladaptive plasticity and alleviated tinnitus without causing additional cochlear damage or hearing loss. These findings suggest that CI‐delivered ES may alleviate tinnitus by reversing maladaptive CN plasticity. Additionally, the extracochlear ES strategy offers a promising tinnitus treatment with minimal risk to hearing.

Brain Communications · 2025

Local field potential signal transmission is correlated with the fractional anisotropy measured by diffusion tractography (opens in a new tab)

Maral Kasiri, Sumiko Abe, Rahil Soroushmojdehi, … Terence D Sanger

Abstract

In this paper we aim to examine the correlation between diffusion tensor imaging parameters of anatomical connectivity and characteristics of signal transmission obtained from patient-specific transfer function models. Here, we focused on elucidating the correlation between structural and functional neural connectivity within a cohort of pediatric patients diagnosed with dystonia. Diffusion tractography images were obtained from 12 patients with dystonia prior to the deep brain stimulation surgery. For each patient, we processed the imaging data to estimate anatomical measures including fractional anisotropy, axial diffusivity, number of fibre tracts per unit area, and fibre tract length. After the implantation of temporary depth leads for each patient as part of their treatment plan, intracranial signals were recorded. Transfer function models of local field potential recordings and the corresponding measures of functional connectivity were computed for each patient. Linear mixed effect analysis was then employed to determine the relationship between transfer function measures and diffusion tractography parameters. Our results illustrate a positive correlation between fractional anisotropy, AD, and intrinsic neural transmission measures, representing amplification and spread of intrinsic neural oscillations, obtained from the transfer functions models. However, no significant correlation was found between the functional connectivity and number of fibre tracts or fibre lengths. Our findings suggest that white matter integrity, as measured by fractional anisotropy and AD, can potentially reflect the amplification and spread of intrinsic brain signals throughout the network. This study underscores the significant relationship between structural and functional connectivity, offering valuable insights into propagation of neural activity in the brain network and potential implications for optimizing non-invasive treatments and planning for neurological disorders.

Advanced Healthcare Materials · Dec 2024

Thermally Drawn Shape and Stiffness Programmable Fibers for Medical Devices (opens in a new tab)

Jiwoo Choi, Qindong Zheng, Mohamed E. M. K. Abdelaziz, … Burak Temelkuran

Abstract

Despite the significant advantages of Shape Memory Polymers (SMPs), material processing and production challenges have limited their applications. Recent advances in fiber manufacturing offer a novel approach to processing polymers, broadening the functions of fibers beyond optical applications. In this study, a thermal drawing technique for SMPs to fabricate Shape Memory Polymer Fibers (SMPFs) tailored for medical applications, featuring programmable stiffness and shape control is developed. Rheological and differential scanning calorimetry analyses are conducted to assess SMP's compatibility with the proposed thermal drawing process and applications, leading to the production of multilumen, multimaterial SMPFs activated at body temperature. Different properties of SMPFs are investigated in three medical devices: stiffness‐adjustable catheters, softening neural interface, and shape‐programmable cochlear implants. Comprehensive characterization of these devices demonstrates the potential of thermally drawn SMPs to be employed in a wide range of applications demanding programmable mechanical properties.

Scientific Reports · Dec 2024

An ultra low frequency spike timing dependent plasticity based approach for reducing alcohol drinking (opens in a new tab)

Anders J. Asp, Suelen Lucio Boschen, Su-Youne Chang, … J. Luis Lujan

Abstract

Alcohol use disorder (AUD) is a chronic relapsing brain disorder characterized by an impaired ability to stop or control alcohol consumption despite adverse social, occupational, or health consequences. AUD affects nearly one-third of adults at some point during their lives, with an associated cost of approximately $249 billion annually in the U.S. alone. The effects of alcohol consumption are expected to increase significantly during the COVID-19 pandemic, with alcohol sales increasing by approximately 54%, potentially exacerbating health concerns and risk-taking behaviors. Unfortunately, existing pharmacological and behavioral therapies for AUD are associated with poor success rates, with approximately 40% of individuals relapsing within three years of treatment.Pre-clinical studies have shown that chronic alcohol consumption leads to significant changes in synaptic function within the dorsal medial striatum (DMS), one of the brain regions associated with AUD and responsible for mediating goal-directed behavior. Specifically, chronic alcohol consumption has been associated with hyperactivity of dopamine receptor 1 (D1) medium spiny neurons (MSN) and hypoactivity of dopamine receptor 2 (D1) MSNs within the DMS. Optogenetic, chemogenetic, and transgenic approaches have demonstrated that reducing the D1/D2 MSN signaling imbalance decreases alcohol self-administration in rodent models of AUD.Here, we present an electrical stimulation approach that uses ultra-low (≤ 1 Hz) frequency (ULF) spike-timing-dependent plasticity (STDP) in mouse models of AUD to reduce DMS D1/D2 MSN signaling imbalances by stimulating D1-MSN afferents into the GPi and ACC glutamatergic projections to the DMS in a time-locked stimulation sequence. Our data suggest that GPi/ACC ULF-STDP selectively decreases DMS D1-MSN hyperactivity leading to reduced alcohol consumption without evoking undesired affective behaviors using electrical stimulation rather than approaches requiring genetic modification. This work represents a step towards fulfilling the unmet need for a reliable method of treating severe AUD through cell-type-specific control with clinically available neuromodulation tools.

The Laryngoscope · Dec 2024

Characterization of Tip Fold-Over Using Fluoroscopy and Intracochlear Pressure in Cadaver Specimens (opens in a new tab)

Carolyn A. Chabuz, Renee M. Banakis Hartl, Kenny Rodriguez, … Nathaniel T. Greene

Abstract

Objectives Cochlear implant array malpositioning is associated with impaired speech perception, vertigo, and facial nerve stimulation. Tip fold‐over is a subset of malpositioning that occurs more often with perimodiolar electrodes, but historically it has not been characterized due to lack of knowledge regarding electrode movements of the electrode within the cochlea. The aim of this study was to characterize the mechanics of tip fold‐over events and their associated insertion pressure profiles. Methods Cadaveric human heads were surgically prepared with a mastoidectomy and facial recess. Fiberoptic pressure sensors were inserted into the scala vestibuli and tympani to measure intracochlear pressures. Perimodiolar CI electrodes (Cochlear Slim‐Modiolar, CI532) were inserted via round window under fluoroscopy. Results Three types of tip fold‐over events were observed: anterior‐posterior C‐shaped, medial‐lateral C‐shaped, and S‐shaped roll‐overs. The largest transient pressures occurred with anterior‐posterior and S‐type roll‐over, and were associated with rotation or twisting inside the cochlea. Conclusions Results demonstrate at least three subtypes of tip fold‐overs. Elevated pressure transients were noted before and during the tip fold‐over event related to electrode twisting. The characterization of tip fold‐over into subtypes is novel and may aid identification of tip fold‐over events intraoperatively in the future. It remains important to identify tip fold‐over events, and they should be recognized early using a multimodal verification system. Further investigation is still required to determine the significance of these changes and other possible patterns of intracochlear electrode movement. Level of Evidence NA: Cadaver study Laryngoscope , 135:1795–1802, 2025

Science Advances · Dec 2024

Future spinal reflex is embedded in primary motor cortex output (opens in a new tab)

Tatsuya Umeda, Osamu Yokoyama, Michiaki Suzuki, … Yukio Nishimura

Abstract

Mammals can execute intended limb movements despite the fact that spinal reflexes involuntarily modulate muscle activity. To generate appropriate muscle activity, the cortical descending motor output must coordinate with spinal reflexes, yet the underlying neural mechanism remains unclear. We simultaneously recorded activities in motor-related cortical areas, afferent neurons, and forelimb muscles of monkeys performing reaching movements. Motor-related cortical areas, predominantly primary motor cortex (M1), encode subsequent afferent activities attributed to forelimb movement. M1 also encodes a subcomponent of muscle activity evoked by these afferent activities, corresponding to spinal reflexes. Furthermore, selective disruption of the afferent pathway specifically reduced this subcomponent of muscle activity, suggesting that M1 output drives muscle activity not only through direct descending pathways but also through the “transafferent” pathway composed of descending plus subsequent spinal reflex pathways. Thus, M1 provides optimal motor output based on an internal forward model that prospectively computes future spinal reflexes.

Scientific Reports · Dec 2024

Interaural level difference sensitivity in neonatally deafened rats fitted with bilateral cochlear implants (opens in a new tab)

Sarah Buchholz, Jan W. H. Schnupp, Susan Arndt, Nicole Rosskothen-Kuhl

Abstract

Bilateral cochlear implant (CI) patients exhibit significant limitations in spatial hearing. Their ability to process interaural time differences (ITDs) is often impaired, while their ability to process interaural level differences (ILDs) remains comparatively good. Clinical studies aiming to identify the causes of these limitations are often plagued by confounds and ethical limitations. Recent behavioral work suggests that rats may be a good animal model for studying binaural hearing under neuroprosthetic stimulation, as rats develop excellent ITD sensitivity when provided with suitable CI stimulation. However, their ability to use ILDs has not yet been characterized. Objective of this study is to address this knowledge gap. Neontally deafened rats were bilaterally fitted with CIs, and trained to lateralize binaural stimuli according to ILD. Their behavioral ILD thresholds were measured at pulse rates from 50 to 2400 pps. CI rats exhibited high sensitivity to ILDs with thresholds of a few dB at all tested pulse rates. We conclude that early deafened rats develop good sensitivity, not only to ITDs but also to ILDs, if provided with appropriate CI stimulation. Their generally good performance, in line with expectations from other mammalian species, validates rats as an excellent model for research on binaural auditory prostheses.

Advanced Materials Technologies · Dec 2024

Softening, Conformable, and Stretchable Conductors for Implantable Bioelectronics Interfaces (opens in a new tab)

Pedro E. Rocha‐Flores, Chandani Chitrakar, Ovidio Rodriguez‐Lopez, … Walter E. Voit

Abstract

Neural implantable devices serve as electronic interfaces facilitating communication between the body and external electronic systems. These bioelectronic systems ideally possess stable electrical conductivity, flexibility, and stretchability to accommodate dynamic movements within the body. However, achieving both high electrical conductivity and mechanical compatibility remains a challenge. Effective electrical conductors tend to be rigid and stiff, leading to a substantial mechanical mismatch with bodily tissues. On the other hand, highly stretchable polymers, while mechanically compatible, often suffer from limited compatibility with lithography techniques and reduced electrical stability. Therefore, there exists a pressing need to develop electromechanically stable neural interfaces that enable precise communication with biological tissues. In this study, a polymer that is softening, flexible, conformal, and compatible with lithography to microfabricate perforated thin‐film architectures is utilized. These architectures offer stretchability and improved mechanical compatibility. Three distinct geometries are evaluated both mechanically and electrically under in vitro conditions that simulate physiological environments. Notably, the Peano structure demonstrates minimal changes in resistance, varying less than 1.5× even when subjected to ≈150% strain. Furthermore, devices exhibit a maximum mechanical elongation before fracture, reaching 220%. Finally, the application of multi‐electrode spinal cord leads employing titanium nitride for neural stimulation in rat models is demonstrated.

eLife · Nov 2024

Cortical neuroprosthesis-mediated functional ipsilateral control of locomotion in rats with spinal cord hemisection (opens in a new tab)

Elena Massai, Marco Bonizzato, Isley De Jesus, … Marina Martinez

Abstract

Control of voluntary limb movement is predominantly attributed to the contralateral motor cortex. However, increasing evidence suggests the involvement of ipsilateral cortical networks in this process, especially in motor tasks requiring bilateral coordination, such as locomotion. In this study, we combined a unilateral thoracic spinal cord injury (SCI) with a cortical neuroprosthetic approach to investigate the functional role of the ipsilateral motor cortex in rat movement through spared contralesional pathways. Our findings reveal that in all SCI rats, stimulation of the ipsilesional motor cortex promoted a bilateral synergy. This synergy involved the elevation of the contralateral foot along with ipsilateral hindlimb extension. Additionally, in two out of seven animals, stimulation of a sub-region of the hindlimb motor cortex modulated ipsilateral hindlimb flexion. Importantly, ipsilateral cortical stimulation delivered after SCI immediately alleviated multiple locomotor and postural deficits, and this effect persisted after ablation of the homologous motor cortex. These results provide strong evidence of a causal link between cortical activation and precise ipsilateral control of hindlimb movement. This study has significant implications for the development of future neuroprosthetic technology and our understanding of motor control in the context of SCI.

Journal of Neurophysiology · Nov 2024

Pairing tones with vagus nerve stimulation improves brain stem responses to speech in the valproic acid model of autism (opens in a new tab)

Yuko Tamaoki, Varun Pasapula, Tanya T. Danaphongse, … Crystal T. Engineer

Abstract

Pairing vagus nerve stimulation (VNS) with sounds has improved auditory processing in the auditory cortex of normal-hearing rats and autism models of rats. This study tests the ability of VNS-sound pairing to restore auditory processing in the inferior colliculus (IC) of valproic acid (VPA)-exposed rats. Pairing VNS with tones significantly reversed the degraded sound processing in the IC in VPA-exposed rats. The findings provide evidence that auditory processing in autism rat models can be improved through VNS.

Sensors · Oct 2024

Comparison of Subdural and Intracortical Recordings of Somatosensory Evoked Responses (opens in a new tab)

Felipe Rettore Andreis, Suzan Meijs, Thomas Gomes Nørgaard dos Santos Nielsen, … Winnie Jensen

Abstract

Micro-electrocorticography (µECoG) electrodes have emerged to balance the trade-off between invasiveness and signal quality in brain recordings. However, its large-scale applicability is still hindered by a lack of comparative studies assessing the relationship between ECoG and traditional recording methods such as penetrating electrodes. This study aimed to compare somatosensory evoked potentials (SEPs) through the lenses of a µECoG and an intracortical microelectrode array (MEA). The electrodes were implanted in the pig’s primary somatosensory cortex, while SEPs were generated by applying electrical stimulation to the ulnar nerve. The SEP amplitude, signal-to-noise ratio (SNR), power spectral density (PSD), and correlation structure were analysed. Overall, SEPs resulting from MEA recordings had higher amplitudes and contained significantly more spectral power, especially at higher frequencies. However, the SNRs were similar between the interfaces. These results demonstrate the feasibility of using µECoG to decode SEPs with wide-range applications in physiology monitoring and brain–computer interfaces.

Nature Communications · Oct 2024

Border-ownership tuning determines the connectivity between V4 and V1 in the macaque visual system (opens in a new tab)

Danique Jeurissen, Anne F. van Ham, Amparo Gilhuis, … Matthew W. Self

Abstract

Cortical feedback connections are extremely numerous but the logic of connectivity between higher and lower areas remains poorly understood. Feedback from higher visual areas to primary visual cortex (V1) has been shown to enhance responses on perceptual figures compared to backgrounds, an effect known as figure-background modulation (FBM). A likely source of this feedback are border-ownership (BO) selective cells in mid-tier visual areas (e.g. V4) which represent the location of figures. We examined the connectivity between V4 cells and V1 cells using noise-correlations and micro-stimulation to estimate connectivity strength. We show that connectivity is consistent with a model in which BO-tuned V4 cells send positive feedback in the direction of their preferred figure and negative feedback in the opposite direction. This connectivity scheme can recreate patterns of FBM observed in previous studies. These results provide insights into the cortical connectivity underlying figure-background perception and establish a link between FBM and BO-tuning.

Communications Biology · Oct 2024

Preselection of potential target spaces based on partial information by the supplementary eye field (opens in a new tab)

Osamu Yokoyama, Yukio Nishimura

Abstract

Before selecting a saccadic target, we often acquire partial information about the location of the forthcoming target and preselect a region of visual space even before the target becomes visible. To determine whether the supplementary eye field (SEF) represents information signifying the potential target space, we examined neuronal activity in the SEF of monkeys performing a behavioral task designed to isolate the process of visuospatial preselection under uncertainty from the process of selecting a specified location. Our data showed that the activity of SEF neurons represented information about the potential target space instructed by symbolic cues. Increased activity of visuospatially selective SEF neurons encoded the potential target space, which could be a mechanism facilitating subsequent selection of an appropriate target. Furthermore, electrical stimulation of the SEF during the preselection period disrupted subsequent target selection. These results demonstrate that the SEF contributes to the preselection of potential target spaces based on partial information.

Neuromodulation: Technology at the Neural Interface · Oct 2024

Cardiovascular Response to Intraneural Right Vagus Nerve Stimulation in Adult Minipig (opens in a new tab)

Filippo Agnesi, Ciro Zinno, Ivo Strauss, … Silvestro Micera

Abstract

Objective: This study explored intraneural stimulation of the right thoracic vagus nerve (VN) in sexually mature male minipigs to modulate safe heart rate and blood pressure response. Material and methods: We employed an intraneural electrode designed for the VN of pigs to perform VN stimulation (VNS). This was delivered using different numbers of contacts on the electrode and different stimulation parameters (amplitude, frequency, and pulse width), identifying the most suitable stimulation configuration. All the parameter ranges had been selected from a computational cardiovascular system model. Results: Clinically relevant responses were observed when stimulating with low current intensities and relatively low frequencies delivered with a single contact. Selecting a biphasic, charge-balanced square wave for VNS with a current amplitude of 500 μA, frequency of 10 Hz, and pulse width of 200 μs, we obtained heart rate reduction of 7.67 ± 5.19 beats per minute, systolic pressure reduction of 5.75 ± 2.59 mmHg, and diastolic pressure reduction of 3.39 ± 1.44 mmHg. Conclusion: Heart rate modulation was obtained without inducing any observable adverse effects, underlining the high selectivity of the intraneural approach.

Lab Animal · Sep 2024

Spared ulnar nerve injury results in increased layer III-VI excitability in the pig somatosensory cortex (opens in a new tab)

Suzan Meijs, Andrew J. Hayward, Thomas Gomes Nørgaard Dos Santos Nielsen, … Winnie Jensen

Abstract

This study describes cortical recordings in a large animal nerve injury model. We investigated differences in primary somatosensory cortex (S1) hyperexcitability when stimulating injured and uninjured nerves and how different cortical layers contribute to S1 hyperexcitability after spared ulnar nerve injury. We used a multielectrode array to record single-neuron activity in the S1 of ten female Danish landrace pigs. Electrical stimulation of the injured and uninjured nerve evoked brain activity up to 3 h after injury. The peak amplitude and latency of early and late peristimulus time histogram responses were extracted for statistical analysis. Histological investigations determined the layer of the cortex in which each electrode contact was placed. Nerve injury increased the early peak amplitude compared with that of the control group. This difference was significant immediately after nerve injury when the uninjured nerve was stimulated, while it was delayed for the injured nerve. The amplitude of the early peak was increased in layers III–VI after nerve injury compared with the control. In layer III, S1 excitability was also increased compared with preinjury for the early peak. Furthermore, the late peak was significantly larger in layer III than in the other layers in the intervention and control group before and after injury. Thus, the most prominent increase in excitability occurred in layer III, which is responsible for the gain modulation of cortical output through layer V. Therefore, layer III neurons seem to have an important role in altered brain excitability after nerve injury.

npj Parkinson's Disease · Sep 2024

Reduced subthalamic and subthalamic-cortical coherences associated with the therapeutic carryover effect of coordinated reset deep brain stimulation (opens in a new tab)

Lvpiao Zheng, Ziling Luo, Biswaranjan Mohanty, … Jing Wang

Abstract

Coordinated reset deep brain stimulation (CR DBS), a promising treatment for Parkinson’s disease (PD), is hypothesized to desynchronize neuronal populations. However, little in vivo data probes this hypothesis. In a parkinsonian nonhuman primate, we found that subthalamic CR DBS suppressed subthalamic and cortical-subthalamic coherences in the beta band, correlating with motor improvements. Our results support the desynchronizing mechanism of CR DBS and propose potential biomarkers for closed-loop CR DBS.

Pharmaceutics · Sep 2024

Molded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model (opens in a new tab)

Chunjiang Wei, Ziwen Gao, Robert Mau, … Verena Scheper

Abstract

Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (µCT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.

Journal of Neurochemistry · Sep 2024

Chronic in vivo sequelae of repetitive acute mfb-DBS on accumbal dopamine and midbrain neuronal activity (opens in a new tab)

Lidia Miguel Telega, Danesh Ashouri Vajari, Chockalingam Ramanathan, … Máté D. Döbrössy

Abstract

Medial Forebrain Bundle Deep Brain Stimulation (MFB‐DBS) can have rapid and long lasting antidepressant effects in Treatment Resistant Depression (TRD) patients. The mechanisms are not well understood, but one hypothesis stipulates that modulation of the dopaminergic (DAergic) fibers contribute to the therapeutic outcome. Acute DBS effects on DA release have been studied; however, longitudinal studies with acute‐repetitive DBS are lacking. Long‐Evans accumbal DA release and Ventral Tegmental Area (VTA) calcium tonic and phasic signaling to different mfb‐DBS parameters were measured using fiber photometry over 8 weeks, following acute and repetitive stimulation in behaving and non‐behaving animals. DBS‐induced release was observed in both targets, with increased frequency and DBS duration. 130 Hz stimulation increased phasic and tonic DA response over time, with the latter being a potential mechanism for its long‐term clinical effectiveness. VTA calcium transients decreased, while phasic activity increased with frequency. Pulse width (PW)‐mediated differential peak release timing also suggests potential parallel activation of diverse fiber types. Additionally, decreased DA transients rate during Elevated Plus Maze (EPM) suggests context and stimulation duration‐dependent DA release. The data confirm chronic antidromic/orthodromic DAergic responses with stimulation parameter dependent variability, providing novel insights into temporal adaptations, connectivity and fiber recruitment on mfb DBS. image

Nature Neuroscience · Sep 2024

Vagus nerve stimulation recruits the central cholinergic system to enhance perceptual learning (opens in a new tab)

Kathleen A. Martin, Eleni S. Papadoyannis, Jennifer K. Schiavo, … Robert C. Froemke

Abstract

Perception can be refined by experience, up to certain limits. It is unclear whether perceptual limits are absolute or could be partially overcome via enhanced neuromodulation and/or plasticity. Recent studies suggest that peripheral nerve stimulation, specifically vagus nerve stimulation (VNS), can alter neural activity and augment experience-dependent plasticity, although little is known about central mechanisms recruited by VNS. Here we developed an auditory discrimination task for mice implanted with a VNS electrode. VNS applied during behavior gradually improved discrimination abilities beyond the level achieved by training alone. Two-photon imaging revealed VNS induced changes to auditory cortical responses and activated cortically projecting cholinergic axons. Anatomical and optogenetic experiments indicated that VNS can enhance task performance through activation of the central cholinergic system. These results highlight the importance of cholinergic modulation for the efficacy of VNS and may contribute to further refinement of VNS methodology for clinical conditions.