bioRxiv* · Feb 2024
Bruno Castellaro, Tony Ka Wing Yip, Fei Peng, … Jan Schnupp
Abstract
Cochlear Implants (CI) are an effective neuroprosthesis for humans with profound hearing loss, enabling deaf adults to have phone calls without lipreading and babies to have successful language development. However, CIs have significant limitations in complex hearing situations, motivating the need for further research, including studies in animal models. Here, we demonstrate the usefulness of wide field Ca++ imaging in assessing different CI stimulation strategies. One major challenge in electrophysiology in CI animals lies in excluding the CI electric artifacts from the recording, since they are orders of magnitude larger than the amplitude of action potentials. Also, electrophysiology can rarely sample large areas of neuropil at high spatial resolution. To circumvent these problems, we have set up an imaging system allowing us to monitor neural activity in the auditory cortex (AC) of CI supplied rats using the Ca++ sensitive dye OGB. Here we describe an initial experiment with this setup, in which we recorded cortical responses to 4 different stimulation patterns which were delivered across 3 CI channels to the contralateral ear. We then investigated two parameters that have been shown to affect intelligibility in CI users: pulse rate and relative pulse timing across CI channels. While pulse rate had only a very modest effect on the discriminability of the neural responses, the stimulation mode had a major effect, with simultaneous pulse timing, perhaps surprisingly, allowing much better pattern discrimination than interleaved sampling. The result suggests that allowing collisions of pulses on neighboring channels may not always be detrimental, at least if partial overlaps of pulses, in which anodic and cathodic pulse phases might cancel, are avoided.
Frontiers in Neuroscience · Feb 2024
W. Mitchel Thomas, Steven A. Zuniga, Inderbir Sondh, … Meredith E. Adams
Abstract
Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.
Neuroscience Bulletin · Feb 2024
Yue Qiu, Le Xie, Xiaohui Wang, … Yu Sun
Abstract
GJB2 gene mutations are the most common causes of autosomal recessive non-syndromic hereditary deafness. For individuals suffering from severe to profound GJB2-related deafness, cochlear implants have emerged as the sole remedy for auditory improvement. Some previous studies have highlighted the crucial role of preserving cochlear neural components in achieving favorable outcomes after cochlear implantation. Thus, we generated a conditional knockout mouse model (Cx26-CKO) in which Cx26 was completely deleted in the cochlear supporting cells driven by the Sox2 promoter. The Cx26-CKO mice showed severe hearing loss and massive loss of hair cells and Deiter's cells, which represented the extreme form of human deafness caused by GJB2 gene mutations. In addition, multiple pathological changes in the peripheral auditory nervous system were found, including abnormal innervation, demyelination, and degeneration of spiral ganglion neurons as well as disruption of heminodes in Cx26-CKO mice. These findings provide invaluable insights into the deafness mechanism and the treatment for severe deafness in Cx26-null mice.
Nature Nanotechnology · Jan 2024
Won Gi Chung, Jiuk Jang, Gang Cui, … Jang-Ung Park
Abstract
Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm −2 ) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.
Brain Stimulation · 2024
Mun J, Lee J, Park SM
Abstract
BACKGROUND: Traditional pharmacological interventions are well tolerated in the management of elevated blood pressure (BP) for individuals with resistant hypertension. Although neuromodulation has been investigated as an alternative solution, its open-loop (OL) modality cannot follow the patient's physiological state. In fact, neuromodulation for controlling highly fluctuating BP necessitates a closed-loop (CL) stimulation modality based on biomarkers to monitor the patient's continuously varying physiological state. OBJECTIVE: By leveraging its intuitive linkage with BP responses in ongoing efforts aimed at developing a CL system to enhance temporal BP reduction effect, this study proposes a CL neuromodulation modality that controls nucleus tractus solitarius (NTS) activity to effectively reduce BP, thus reflecting continuously varying physiological states. METHOD: While performing neurostimulation targeting the NTS in the rat model, the arterial BP response and neural activity of the NTS were simultaneously measured. To evaluate the temporal BP response effect of CL neurostimulation, OL (constant parameter; 20 Hz, 200 μA) and CL (Initial parameter; 11 Hz, 112 μA) stimulation protocols were performed with stimulation 180 s and rest 600 s, respectively, and examined NTS activity and BP response to the protocols. RESULTS: In-vivo experiments for OL versus CL protocol for direct NTS stimulation in rats demonstrated an enhancement in temporal BP reduction via the CL modulation of NTS activity. CONCLUSION: This study proposes a CL stimulation modality that enhances the effectiveness of BP control using a feedback control algorithm based on neural signals, thereby suggesting a new approach to antihypertensive neuromodulation.
Bioengineering · Dec 2023
Joseph Chen, Jayden Sprigg, Nicholas Castle, … Chenkai Dai
Abstract
Bilateral vestibular deficiency (BVD) results in chronic dizziness, blurry vision when moving the head, and postural instability. Vestibular prostheses (VPs) show promise as a treatment, but the VP-restored vestibulo-ocular reflex (VOR) gain in human trials falls short of expectations. We hypothesize that the slope of the rising ramp in stimulation pulses plays an important role in the recruitment of vestibular afferent units. To test this hypothesis, we utilized customized programming to generate ramped pulses with different slopes, testing their efficacy in inducing electrically evoked compound action potentials (eCAPs) and current spread via bench tests and simulations in a virtual inner model created in this study. The results confirmed that the slope of the ramping pulses influenced the recruitment of vestibular afferent units. Subsequently, an optimized stimulation pulse train was identified using model simulations, exhibiting improved modulation of vestibular afferent activity. This optimized slope not only reduced the excitation spread within the semicircular canals (SCCs) but also expanded the neural dynamic range. While the model simulations exhibited promising results, in vitro and in vivo experiments are warranted to validate the findings of this study in future investigations.
Obesity Surgery · Dec 2023
Monique Leinen, Elise F. Grandy, Lourdes M. Ubeira Gebel, … Matthew A. Schiefer
Abstract
Introduction Obesity affects millions of Americans. The vagal nerves convey the degree of stomach fullness to the brain via afferent visceral fibers. Studies have found that vagal nerve stimulation (VNS) promotes reduced food intake, causes weight loss, and reduces cravings and appetite. Methods Here, we evaluate the efficacy of a novel stimulus waveform applied bilaterally to the subdiaphragmatic vagal nerve stimulation (sVNS) for almost 13 weeks. A stimulating cuff electrode was implanted in obesity-prone Sprague Dawley rats maintained on a high-fat diet. Body weight, food consumption, and daily movement were tracked over time and compared against three control groups: sham rats on a high-fat diet that were implanted with non-operational cuffs, rats on a high-fat diet that were not implanted, and rats on a standard diet that were not implanted. Results Results showed that rats on a high-fat diet that received sVNS attained a similar weight to rats on a standard diet due primarily to a reduction in daily caloric intake. Rats on a high-fat diet that received sVNS had significantly less body fat than other high-fat controls. Rats receiving sVNS also began moving a similar amount to rats on the standard diet. Conclusion Results from this study suggest that bilateral subdiaphragmatic vagal nerve stimulation can alter the rate of growth of rats maintained on a high-fat diet through a reduction in daily caloric intake, returning their body weight to that which is similar to rats on a standard diet over approximately 13 weeks. Graphical Abstract
Journal of Plastic, Reconstructive & Aesthetic Surgery : JPRAS · Oct 2023
Nicksic PJ, Donnelly DT, Zeng W, … Dingle AM
Abstract
Background The hypothesis of this study was that trigeminal nerve stimulation (TNS) or peripheral nerve stimulation (PNS) could improve functional outcomes of peripheral nerve injury in a rat forelimb model when compared to control rats not receiving electrical stimulation (ES). While PNS is known to improve outcomes after nerve surgery, the role of TNS has not been explored. Methods Lewis rats were trained to perform a reach and grasp task before receiving a 2 mm gap repair of the ulnar and median nerves and randomized into four treatment groups: (1) sham injury, (2) nerve injury with sham ES, (3) nerve injury with PNS, and (4) nerve injury with TNS. Functional motor (median pull force and percent success in motor task) and sensory metrics (forelimb paw withdrawal thresholds) were collected both pre-injury and throughout rehabilitation. Nerves stained using Gomori's trichrome were assessed quantitatively and qualitatively. Results The sham ES group did not recover their pre-injury baseline functional outcomes. In contrast, the TNS and PNS groups fully recovered following injury, with no difference in functional outcomes between the pre-injury baseline and the final week of rehabilitation (P > 0.05, all). Histomorphology results demonstrated no quantitative difference, but qualitative differences in architecture were evident. Conclusions Electrical stimulation of the trigeminal nerve or the injured nerve improved the functional outcomes of nerve regeneration in rodents. Histomorphology results of nerves from the TNS group support the proposed central mechanisms. This is an important step in translating this therapy as an adjunct, non-invasive treatment for high, mixed nerve injuries in humans.
bioRxiv* · Aug 2023
Lee J, Mun J, Park S
Abstract
The brainstem serves as an intermediary processor of haemodynamic sensations via nucleus tractus solitaries (NTS) in regulating circulatory system. After sensing visceral inputs, the NTS relays information to efferent pathways to modulate peripheral viscera. However, the neural computation mechanism underlying how the NTS processes viscerosensory input remains unknown. Here, we show the computational principles embedded inside the NTS of rats, producing haemodynamic modulation in concert. Our findings demonstrate that the collective dynamics leveraging from neuronal population within the NTS neural circuit encode input-driven haemodynamics. The NTS exhibits the neural trajectory, the dynamical trace of neural states, which is confined to low-dimensional latent space and may represent haemodynamic perturbations. Surprisingly, by normalizing neural trajectory of rats, we found the across-rat common rules for the viscerosensory-information processing by the NTS. Furthermore, the common rules allowed to identify inter-subject variable haemodynamics by quantifying the computational mechanisms in neuro-haemodynamic axis. Our findings provide pioneering insights into understanding the neural computation involved in regulation of visceral functions by the autonomic nervous system.
Frontiers in Neurology · Aug 2023
Brett A. Campbell, Leonardo Favi Bocca, Jakov Tiefenbach, … Kenneth B. Baker
Abstract
Introduction The therapeutic efficacy of deep brain stimulation (DBS) of the subthalamic nucleus (STN) for Parkinson’s disease (PD) may be limited for some patients by the presence of stimulation-related side effects. Such effects are most often attributed to electrical current spread beyond the target region. Prior computational modeling studies have suggested that changing the degree of asymmetry of the individual phases of the biphasic, stimulus pulse may allow for more selective activation of neural elements in the target region. To the extent that different neural elements contribute to the therapeutic vs. side-effect inducing effects of DBS, such improved selectivity may provide a new parameter for optimizing DBS to increase the therapeutic window. Methods We investigated the effect of six different pulse geometries on cortical and myogenic evoked potentials in eight patients with PD whose leads were temporarily externalized following STN DBS implant surgery. DBS-cortical evoked potentials were quantified using peak to peak measurements and wavelets and myogenic potentials were quantified using RMS. Results We found that the slope of the recruitment curves differed significantly as a function of pulse geometry for both the cortical- and myogenic responses. Notably, this effect was observed most frequently when stimulation was delivered using a monopolar, as opposed to a bipolar, configuration. Discussion Manipulating pulse geometry results in differential physiological effects at both the cortical and neuromuscular level. Exploiting these differences may help to expand DBS’ therapeutic window and support the potential for incorporating pulse geometry as an additional parameter for optimizing therapeutic benefit.
bioRxiv* · Aug 2023
Ruszala B, Mazurek KA, Schieber MH
Abstract
Intracortical microstimulation (ICMS) is known to affect distant neurons transynaptically, yet the extent to which ICMS pulses delivered in one cortical area modulate neurons in other cortical areas remains largely unknown. Here we assessed how the individual pulses of multi-channel ICMS trains delivered in the upper extremity representation of the macaque primary somatosensory area (S1) modulate neuron firing in the primary motor cortex (M1) and in the ventral premotor cortex (PMv). S1-ICMS pulses modulated the majority of units recorded both in the M1 upper extremity representation and in PMv, producing more inhibition than excitation. Effects converged on individual neurons in both M1 and PMv from extensive S1 territories. Conversely, effects of ICMS delivered in a small region of S1 diverged to wide territories in both M1 and PMv. The effects of this direct modulation of M1 and PMv neurons produced by multi-electrode S1-ICMS like that used here may need to be taken into account by bidirectional brain-computer interfaces that decode intended movements from neural activity in these cortical motor areas. Significance Statement Although ICMS is known to produce effects transynaptically, relatively little is known about how ICMS in one cortical area affects neurons in other cortical areas. We show that the effects of multi-channel ICMS in a small patch of S1 diverge to affect neurons distributed widely in both M1 and PMv, and conversely, individual neurons in each of these areas can be affected by ICMS converging from much of the S1 upper extremity representation. Such direct effects of ICMS may complicate the decoding of motor intent from M1 or PMv when artificial sensation is delivered via S1-ICMS in bidirectional brain-computer interfaces.
bioRxiv* · Aug 2023
Jan W. H. Schnupp, Sarah Buchholz, Alexa N. Buck, … Nicole Rosskothen-Kuhl
Abstract
Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the “fine structure” ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance Statement CIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brain’s ability to process temporal sound features with sub-millisecond precision. CIs “sample” sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.
bioRxiv* · Jul 2023
Sarah E Gartside, Adrian Rees, Bas MJ Olthof
Abstract
We have recently reported that the central nucleus of the inferior colliculus (the auditory midbrain) is innervated by glutamatergic pyramidal cells originating not only in auditory cortex (AC) but also in multiple ‘non-auditory’ regions of the cerebral cortex. Using optogenetics and electrical stimulation, we investigated the functional properties of these descending connections in vivo in anaesthetised rats. A retrograde virus encoding green fluorescent protein (GFP) and channelrhodopsin (ChR2) injected into the central nucleus of the inferior colliculus (ICC), labelled discrete groups of cells in multiple areas of the cerebral cortex. Light stimulation of AC and M1 caused local activation of cortical neurones and increased the firing rate of neurones in ICc indicating a direct excitatory input from AC and M1 to ICC. Electrical stimulation of M1, secondary motor, somatosensory and prefrontal cortical regions evoked short, fixed latency firing events in ICC as well as longer latency, longer duration increases in firing activity. The short latency events were singular spikes of consistent shape and size likely resulting from monosynaptic excitation of individual ICC units. The longer latency responses comprised multiple units and spikes occurred with significant temporal jitter suggesting polysynaptic activation of local circuits within the ICC. The probability of the monosynaptic event, the magnitude of the polysynaptic response, and the area of ICC affected were dependent on the stimulus current. Our data are consistent with cortical regions exerting an important excitatory direct and indirect regulation of ICc neurones. Significance statement We have recently described inputs from motor, somatosensory, and executive cortices to the inferior colliculus (IC, auditory midbrain). Here we provide functional evidence for such connections. Optogenetics, using a retrograde virus encoding channelrhodopsin injected into IC revealed a direct excitatory influence of neurones in auditory and motor cortices on firing in IC. Electrical stimulation of discrete cortical regions revealed that multiple non-auditory cortical regions have a direct monosynaptic excitatory influence on neurones in the IC which, in turn, activates local circuits increasing the firing probability of multiple neurones in the IC. This is the first evidence for circuitry by which auditory processing can be influenced at an early stage by activity in the sensory, motor and executive domains.
Bioelectronic Medicine · Jul 2023
Lauren Savannah Dewberry, Ken Porche, Travis Koenig, … Kevin J. Otto
Abstract
Background The purpose of this study was to evaluate if kilohertz frequency alternating current (KHFAC) stimulation of peripheral nerve could serve as a treatment for lumbar radiculopathy. Prior work shows that KHFAC stimulation can treat sciatica resulting from chronic sciatic nerve constriction. Here, we evaluate if KHFAC stimulation is also beneficial in a more physiologic model of low back pain which mimics nucleus pulposus (NP) impingement of a lumbar dorsal root ganglion (DRG). Methods To mimic a lumbar radiculopathy, autologous tail NP was harvested and placed upon the right L5 nerve root and DRG. During the same surgery, a cuff electrode was implanted around the sciatic nerve with wires routed to a headcap for delivery of KHFAC stimulation. Male Lewis rats (3 mo., n = 18) were separated into 3 groups: NP injury + KHFAC stimulation ( n = 7), NP injury + sham cuff ( n = 6), and sham injury + sham cuff ( n = 5). Prior to surgery and for 2 weeks following surgery, animal tactile sensitivity, gait, and static weight bearing were evaluated. Results KHFAC stimulation of the sciatic nerve decreased behavioral evidence of pain and disability. Without KHFAC stimulation, injured animals had heightened tactile sensitivity compared to baseline ( p < 0.05), with tactile allodynia reversed during KHFAC stimulation ( p < 0.01). Midfoot flexion during locomotion was decreased after injury but improved with KHFAC stimulation ( p < 0.05). Animals also placed more weight on their injured limb when KHFAC stimulation was applied ( p < 0.05). Electrophysiology measurements at end point showed decreased, but not blocked, compound nerve action potentials with KHFAC stimulation ( p < 0.05). Conclusions KHFAC stimulation decreases hypersensitivity but does not cause additional gait compensations. This supports the idea that KHFAC stimulation applied to a peripheral nerve may be able to treat chronic pain resulting from sciatic nerve root inflammation.
Neuron · Jul 2023
Qun Li, Yuichi Takeuchi, Jiale Wang, … Antal Berényi
Abstract
Although the etiology of major depressive disorder remains poorly understood, reduced gamma oscillations is an emerging biomarker. Olfactory bulbectomy, an established model of depression that reduces limbic gamma oscillations, suffers from non-specific effects of structural damage. Here, we show that transient functional suppression of olfactory bulb neurons or their piriform cortex efferents decreased gamma oscillation power in limbic areas and induced depression-like behaviors in rodents. Enhancing transmission of gamma oscillations from olfactory bulb to limbic structures by closed-loop electrical neuromodulation alleviated these behaviors. By contrast, silencing gamma transmission by anti-phase closed-loop stimulation strengthened depression-like behaviors in naive animals. These induced behaviors were neutralized by ketamine treatment that restored limbic gamma power. Taken together, our results reveal a causal link between limbic gamma oscillations and depression-like behaviors in rodents. Interfering with these endogenous rhythms can affect behaviors in rodent models of depression, suggesting that restoring gamma oscillations may alleviate depressive symptoms.
iScience · Jul 2023
Michael G. Metzen, Maurice J. Chacron
Abstract
The functional role of heterogeneous spiking responses of otherwise similarly tuned neurons to stimulation, which has been observed ubiquitously, remains unclear to date. Here, we demonstrate that such response heterogeneity serves a beneficial function that is used by downstream brain areas to generate behavioral responses that follows the detailed timecourse of the stimulus. Multi-unit recordings from sensory pyramidal cells within the electrosensory system of Apteronotus leptorhynchus were performed and revealed highly heterogeneous responses that were similar for all cell types. By comparing the coding properties of a given neural population before and after inactivation of descending pathways, we found that heterogeneities were beneficial as decoding was then more robust to the addition of noise. Taken together, our results not only reveal that descending pathways actively promote response heterogeneity within a given cell type, but also uncover a beneficial function for such heterogeneity that is used by the brain to generate behavior.
Frontiers in Neuroscience · Jun 2023
Elliott W. Dirr, Yogi Patel, Richard D. Johnson, Kevin J. Otto
Abstract
During type 1 diabetes, an autoimmune attack destroys pancreatic β-cells leading to the inability to maintain glucose homeostasis. These β-cells are neuroresponsive endocrine cells which normally secrete insulin partially in response to input from the vagus nerve. This neural pathway can be utilized as a point of therapeutic intervention by delivering exogenous stimulation to drive increased insulin secretion. In this study, a cuff electrode was implanted on the pancreatic branch of the vagus nerve just prior to pancreatic insertion in rats, and a continuous glucose meter was implanted into the descending aorta. Streptozotocin (STZ) was used to induce a diabetic state, and changes in blood glucose were assessed using various stimulation parameters. Stimulation driven changes in hormone secretion, pancreatic blood flow, and islet cell populations were assessed. We found increased changes in the rate of blood glucose change during stimulation which subsided after stimulation ended paired with increased concentration of circulating insulin. We did not observe increased pancreatic perfusion, which suggests that the modulation of blood glucose was due to the activation of b-cells rather than changes in the extra-organ transport of insulin. Pancreatic neuromodulation showed potentially protective effects by reducing deficits in islet diameter, and ameliorating insulin loss after STZ treatment.
May 2023
Stephan L Blanz
Abstract
This protocol was used to collect data now published in the Journal of Neural Engineering, Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect using the multi-contact ImThera stimulating device. https://doi.org/10.1088/1741-2552/acb3fd Dataset has been published to pennsieve.io and can be found at: https://doi.org/10.26275/efbj-8evl
Journal of Integrative Neuroscience · May 2023
Jordan A. Borrell, Domenico Gattozzi, Dora Krizsan-Agbas, … Shawn B. Frost
Abstract
Background: The purpose of this proof-of-concept feasibility study was to determine if spike-triggered intraspinal microstimulation (ISMS), a form of activity dependent stimulation (ADS), results in improved motor performance in an ambulatory rat model of spinal cord injury (SCI). Methods: Experiments were carried out in adult male Sprague Dawley rats with moderate thoracic contusion injury. Rats were assigned to one of two groups: Control or ADS therapy. Four weeks post-SCI, all rats were implanted with a recording microelectrode in the left hindlimb motor cortex and a fine-wire stimulating electrode in the contralateral lumbar spinal cord. ADS was administered for 4 hours/day, 4 days/week, for 4 weeks. During therapy sessions, single-unit spikes were discriminated in real time in the hindlimb motor cortex and used to trigger stimulation in the spinal cord ventral horn. Control rats were similarly implanted with electrodes but did not receive stimulation therapy. Results: Motor performances of each rat were evaluated before SCI contusion, once a week post-SCI for four weeks (prior to electrode implantation), and once a week post-conditioning for four weeks. Basso, Beattie, and Bresnahan (BBB) locomotor scores were significantly improved in ADS rats compared to Control rats at 1 and 2 weeks after initiation of therapy. Foot fault scores on the Horizontal Ladder were significantly improved in ADS rats compared to pre-therapy ADS and Control rats after 1 week of therapy and recovered to near pre-injury scores after 3 weeks of therapy. The Ledged Beam test showed deficits after SCI in both ADS and Control rats but there were no significant differences between groups after 4 weeks of ADS therapy. Conclusions: These results show that chronic stimulation after spinal cord injury using a methodology of spike-triggered ISMS enhances behavioral recovery of locomotor function as measured by the BBB score and the Horizontal Ladder task. However, it is still uncertain if the behavioral improvements seen were dependent on spike-triggered ISMS.
Brain Stimulation · May 2023
Christopher Hughes, Takashi Kozai
Abstract
Background: Intracortical microstimulation (ICMS) is an emerging approach to restore sensation to people with neurological injury or disease. Biomimetic microstimulation, or stimulus trains that mimic neural activity in the brain through encoding of onset and offset transients, could improve the utility of ICMS for brain-computer interface (BCI) applications, but how biomimetic microstimulation affects neural activation is not understood. Current "biomimetic" ICMS trains aim to reproduce the strong onset and offset transients evoked in the brain by sensory input through dynamic modulation of stimulus parameters. Stimulus induced depression of neural activity (decreases in evoked intensity over time) is also a potential barrier to clinical implementation of sensory feedback, and dynamic microstimulation may reduce this effect. Objective: We evaluated how bio-inspired ICMS trains with dynamic modulation of amplitude and/or frequency change the calcium response, spatial distribution, and depression of neurons in the somatosensory and visual cortices. Methods: Calcium responses of neurons were measured in Layer 2/3 of visual and somatosensory cortices of anesthetized GCaMP6s mice in response to ICMS trains with fixed amplitude and frequency (Fixed) and three dynamic ICMS trains that increased the stimulation intensity during the onset and offset of stimulation by modulating the amplitude (DynAmp), frequency (DynFreq), or amplitude and frequency (DynBoth). ICMS was provided for either 1-s with 4-s breaks (Short) or for 30-s with 15-s breaks (Long). Results: DynAmp and DynBoth trains evoked distinct onset and offset transients in recruited neural populations, while DynFreq trains evoked population activity similar to Fixed trains. Individual neurons had heterogeneous responses primarily based on how quickly they depressed to ICMS, where neurons farther from the electrode depressed faster and a small subpopulation (1-5%) were modulated by DynFreq trains. Neurons that depressed to Short trains were also more likely to depress to Long trains, but Long trains induced more depression overall due to the increased stimulation length. Increasing the amplitude during the hold phase resulted in an increase in recruitment and intensity which resulted in more depression and reduced offset responses. Dynamic amplitude modulation reduced stimulation induced depression by 14.6 ± 0.3% for Short and 36.1 ± 0.6% for Long trains. Ideal observers were 0.031 ± 0.009 s faster for onset detection and 1.33 ± 0.21 s faster for offset detection with dynamic amplitude encoding. Conclusions: Dynamic amplitude modulation evokes distinct onset and offset transients, reduces depression of neural calcium activity, and decreases total charge injection for sensory feedback in BCIs by lowering recruitment of neurons during long maintained periods of ICMS. In contrast, dynamic frequency modulation evokes distinct onset and offset transients in a small subpopulation of neurons but also reduces depression in recruited neurons by reducing the rate of activation.
* Preprint: not yet peer reviewed.