Advanced Materials Technologies · Dec 2024

Softening, Conformable, and Stretchable Conductors for Implantable Bioelectronics Interfaces (opens in a new tab)

Pedro E. Rocha‐Flores, Chandani Chitrakar, Ovidio Rodriguez‐Lopez, … Walter E. Voit

Abstract

Neural implantable devices serve as electronic interfaces facilitating communication between the body and external electronic systems. These bioelectronic systems ideally possess stable electrical conductivity, flexibility, and stretchability to accommodate dynamic movements within the body. However, achieving both high electrical conductivity and mechanical compatibility remains a challenge. Effective electrical conductors tend to be rigid and stiff, leading to a substantial mechanical mismatch with bodily tissues. On the other hand, highly stretchable polymers, while mechanically compatible, often suffer from limited compatibility with lithography techniques and reduced electrical stability. Therefore, there exists a pressing need to develop electromechanically stable neural interfaces that enable precise communication with biological tissues. In this study, a polymer that is softening, flexible, conformal, and compatible with lithography to microfabricate perforated thin‐film architectures is utilized. These architectures offer stretchability and improved mechanical compatibility. Three distinct geometries are evaluated both mechanically and electrically under in vitro conditions that simulate physiological environments. Notably, the Peano structure demonstrates minimal changes in resistance, varying less than 1.5× even when subjected to ≈150% strain. Furthermore, devices exhibit a maximum mechanical elongation before fracture, reaching 220%. Finally, the application of multi‐electrode spinal cord leads employing titanium nitride for neural stimulation in rat models is demonstrated.

eLife · Nov 2024

Cortical neuroprosthesis-mediated functional ipsilateral control of locomotion in rats with spinal cord hemisection (opens in a new tab)

Elena Massai, Marco Bonizzato, Isley De Jesus, … Marina Martinez

Abstract

Control of voluntary limb movement is predominantly attributed to the contralateral motor cortex. However, increasing evidence suggests the involvement of ipsilateral cortical networks in this process, especially in motor tasks requiring bilateral coordination, such as locomotion. In this study, we combined a unilateral thoracic spinal cord injury (SCI) with a cortical neuroprosthetic approach to investigate the functional role of the ipsilateral motor cortex in rat movement through spared contralesional pathways. Our findings reveal that in all SCI rats, stimulation of the ipsilesional motor cortex promoted a bilateral synergy. This synergy involved the elevation of the contralateral foot along with ipsilateral hindlimb extension. Additionally, in two out of seven animals, stimulation of a sub-region of the hindlimb motor cortex modulated ipsilateral hindlimb flexion. Importantly, ipsilateral cortical stimulation delivered after SCI immediately alleviated multiple locomotor and postural deficits, and this effect persisted after ablation of the homologous motor cortex. These results provide strong evidence of a causal link between cortical activation and precise ipsilateral control of hindlimb movement. This study has significant implications for the development of future neuroprosthetic technology and our understanding of motor control in the context of SCI.

The Journal of Neuroscience · Nov 2024

Nonresponsive Neurons Improve Population Coding of Object Location (opens in a new tab)

Myriah Haggard, Maurice J. Chacron

Abstract

Understanding how heterogeneous neural populations represent sensory input to give rise to behavior remains a central problem in systems neuroscience. Here we investigated how midbrain neurons within the electrosensory system of Apteronotus leptorhynchus code for object location in space. In vivo simultaneous recordings were achieved via Neuropixels probes, high-density electrode arrays, with the stimulus positioned at different locations relative to the animal. Midbrain neurons exhibited heterogeneous response profiles, with a significant proportion (65%) seemingly nonresponsive to moving stimuli. Remarkably, we found that nonresponsive neurons increased population coding of object location through synergistic interactions with responsive neurons by effectively reducing noise. Mathematical modeling demonstrated that increased response heterogeneity together with the experimentally observed correlations was sufficient to give rise to independent encoding by responsive neurons. Furthermore, the addition of nonresponsive neurons in the model gave rise to synergistic population coding. Taken together, our findings reveal that nonresponsive neurons, which are frequently excluded from analysis, can significantly improve population coding of object location through synergistic interactions with responsive neurons. Combinations of responsive and nonresponsive neurons have been observed in sensory systems across taxa; it is likely that similar synergistic interactions improve population coding across modalities and behavioral tasks.

Biomaterials · Nov 2024

Dynamic changes in the structure and function of brain mural cells around chronically implanted microelectrodes (opens in a new tab)

Wellman SM, Forrest AM, Douglas MM, … Kozai TDY

Abstract

Integration of neural interfaces with minimal tissue disruption in the brain is ideal to develop robust tools that can address essential neuroscience questions and combat neurological disorders. However, implantation of intracortical devices provokes severe tissue inflammation within the brain, which requires a high metabolic demand to support a complex series of cellular events mediating tissue degeneration and wound healing. Pericytes, peri-vascular cells involved in blood-brain barrier maintenance, vascular permeability, waste clearance, and angiogenesis, have recently been implicated as potential perpetuators of neurodegeneration in brain injury and disease. While the intimate relationship between pericytes and the cortical microvasculature have been explored in other disease states, their behavior following microelectrode implantation, which is responsible for direct blood vessel disruption and dysfunction, is currently unknown. Using two-photon microscopy we observed dynamic changes in the structure and function of pericytes during implantation of a microelectrode array over a 4-week implantation period. Pericytes respond to electrode insertion through transient increases in intracellular calcium and underlying constriction of capillary vessels. Within days following the initial insertion, we observed an influx of new, proliferating pericytes which contribute to new blood vessel formation. Additionally, we discovered a potentially novel population of reactive immune cells in close proximity to the electrode-tissue interface actively engaging in encapsulation of the microelectrode array. Finally, we determined that intracellular pericyte calcium can be modulated by intracortical microstimulation in an amplitude- and frequency-dependent manner. This study provides a new perspective on the complex biological sequelae occurring at the electrode-tissue interface and will foster new avenues of potential research consideration and lead to development of more advanced therapeutic interventions towards improving the biocompatibility of neural electrode technology.

Journal of Neural Engineering · Oct 2024

Simultaneous modulation of pulse charge and burst period elicits two differentiable referred sensations (opens in a new tab)

Benigni TR, Pena AE, Kuntaegowdanahalli SS, … Jung R

Abstract

Objective. To investigate the feasibility of delivering multidimensional feedback using a single channel of peripheral nerve stimulation by complementing intensity percepts with flutter frequency percepts controlled by burst period modulation. Approach. Two dimensions of a distally referred sensation were provided simultaneously: intensity was conveyed by the modulation of the pulse charge rate inside short discrete periods of stimulation referred to as bursts and frequency was conveyed by the modulation of the period between bursts. For this approach to be feasible, intensity percepts must be perceived independently of frequency percepts. Two experiments investigated these interactions. A series of two alternative forced choice tasks (2AFC) were used to investigate burst period modulation's role in intensity discernibility. Magnitude estimation tasks were used to determine any interactions in the gradation between the frequency and intensity percepts. Main results. The 2AFC revealed that burst periods can be individually differentiated as a gradable frequency percept in peripheral nerve stimulation. Participants could correctly rate a perceptual scale of intensity and frequency regardless of the value of the second, but the dependence of frequency differentiability on charge rate indicates that frequency was harder to detect with weaker intensity percepts. The same was not observed in intensity differentiability as the length of burst periods did not significantly alter intensity differentiation. These results suggest multidimensional encoding is a promising approach for increasing information throughput in sensory feedback systems if intensity ranges are selected properly. Significance. This study offers valuable insights into haptic feedback through the peripheral nervous system and demonstrates an encoding approach for neural stimulation that may offer enhanced information transfer in virtual reality applications and sensory-enabled prosthetic systems. This multidimensional encoding strategy for sensory feedback may open new avenues for enriched control capabilities.

Nature Neuroscience · Sep 2024

Vagus nerve stimulation recruits the central cholinergic system to enhance perceptual learning (opens in a new tab)

Kathleen A. Martin, Eleni S. Papadoyannis, Jennifer K. Schiavo, … Robert C. Froemke

Abstract

Perception can be refined by experience, up to certain limits. It is unclear whether perceptual limits are absolute or could be partially overcome via enhanced neuromodulation and/or plasticity. Recent studies suggest that peripheral nerve stimulation, specifically vagus nerve stimulation (VNS), can alter neural activity and augment experience-dependent plasticity, although little is known about central mechanisms recruited by VNS. Here we developed an auditory discrimination task for mice implanted with a VNS electrode. VNS applied during behavior gradually improved discrimination abilities beyond the level achieved by training alone. Two-photon imaging revealed VNS induced changes to auditory cortical responses and activated cortically projecting cholinergic axons. Anatomical and optogenetic experiments indicated that VNS can enhance task performance through activation of the central cholinergic system. These results highlight the importance of cholinergic modulation for the efficacy of VNS and may contribute to further refinement of VNS methodology for clinical conditions.

bioRxiv* · Aug 2024

Extended-Interval Theta Burst Stimulation Enhances Glutamatergic Plasticity and Antidepressant Effects via Reduced GABAergic Recruitment (opens in a new tab)

Salimi M, Nazari M, Linnik A, … Ramanathan DS

Abstract

Summary Intermittent Theta Burst Stimulation (iTBS) is a patterned stimulation protocol FDA-cleared to treat depression, yet its outcomes are variable and mechanistically unclear. Here, using a combination of calcium imaging, histology, optogenetics and behavior, we show that one parameter of iTBS, the inter-train interval (ITI) between stimulation trains, plays a critical role in modulating GABAergic (and especially parvalbumin) neuronal activity, modulating subsequent neuronal plasticity and antidepressant effects. Shorter ITI stimulation protocols (4-10Ssinter-train intervals) activate GABA neurons, limiting resulting changes in cortical excitability and plasticity compared to extended interval TBS protocols (eTBS, with a 20s ITI). eTBS also drives the largest changes in synaptic / spine plasticity and leads to rapid and durable antidepressant-like effects after only a single stimulation session. Optogenetic activation of GABAergic neurons during eTBS blocks synaptic plasticity and rapid antidepressant effects. Together, these findings reveal a temporal control principle for TBS-induced cortical plasticity and provides a physiology-based strategy to improve TBS efficacy. Highlights Inter-train interval (ITI) controls excitatory-inhibitory balance during theta burst stimulation Short ITIs strongly activate PV interneurons limiting longer-term changes in glutamatergic excitatory plasticity Extended ITI (20s in particular) reduces inhibitory activity while maintaining sufficient activation of glutamatergic neurons to promote post-stimulation plasticity eTBS produces rapid and durable antidepressant-like effects that are blocked by GABAergic co-activation Graphical Abstract Inter-train interval (ITI) determines the balance between excitation and inhibition during theta burst stimulation (TBS), an FDA-cleared treatment for depression. (A) Short ITIs (4s) drive concurrent glutamatergic and GABAergic activation, with inhibitory dominance during stimulation and suppressed long-term modulation of excitability. Extending the ITI to 20s (eTBS) reduces GABAergic recruitment during stimulation, promoting sustained long-term glutamatergic modulation resulting cortical disinhibition, leading to rapid and durable antidepressant-like effects (B) . Optogenetic activation of GABAergic interneurons during eTBS abolishes synaptic and antidepressant effects, demonstrating that reduced inhibitory recruitment during eTBS is required for the rapid and durable behavioral effects observed with that protocol.

Cognitive Affective & Behavioral Neuroscience · Aug 2024

Cortico-striatal beta oscillations as a reward-related signal (opens in a new tab)

M. F. Koloski, S. Hulyalkar, S. A. Barnes, … D. S. Ramanathan

Abstract

The value associated with reward is sensitive to external factors, such as the time between the choice and reward delivery as classically manipulated in temporal discounting tasks. Subjective preference for two reward options is dependent on objective variables of reward magnitude and reward delay. Single neuron correlates of reward value have been observed in regions, including ventral striatum, orbital, and medial prefrontal cortex. Brain imaging studies show cortico-striatal-limbic network activity related to subjective preferences. To explore how oscillatory dynamics represent reward processing across brain regions, we measured local field potentials of rats performing a temporal discounting task. Our goal was to use a data-driven approach to identify an electrophysiological marker that correlates with reward preference. We found that reward-locked oscillations at beta frequencies signaled the magnitude of reward and decayed with longer temporal delays. Electrodes in orbitofrontal/medial prefrontal cortex, anterior insula, ventral striatum, and amygdala individually increased power and were functionally connected at beta frequencies during reward outcome. Beta power during reward outcome correlated with subjective value as defined by a computational model fit to the discounting behavior. These data suggest that cortico-striatal beta oscillations are a reward signal correlated, which may represent subjective value and hold potential to serve as a biomarker and potential therapeutic target.

Bioelectronic Medicine · Jul 2024

The role of spinal cord neuroanatomy and the variances of epidurally evoked spinal responses (opens in a new tab)

Danny V. Lam, Justin Chin, Meagan K. Brucker-Hahn, … Igor Lavrov

Abstract

Background Spinal cord stimulation (SCS) has demonstrated multiple benefits in treating chronic pain and other clinical disorders related to sensorimotor dysfunctions. However, the underlying mechanisms are still not fully understood, including how electrode placement in relation to the spinal cord neuroanatomy influences epidural spinal recordings (ESRs). To characterize this relationship, this study utilized stimulation applied at various anatomical sections of the spinal column, including at levels of the intervertebral disc and regions correlating to the dorsal root entry zone. Method Two electrode arrays were surgically implanted into the dorsal epidural space of the swine. The stimulation leads were positioned such that the caudal-most electrode contact was at the level of a thoracic intervertebral segment. Intraoperative cone beam computed tomography (CBCT) images were utilized to precisely determine the location of the epidural leads relative to the spinal column. High-resolution microCT imaging and 3D-model reconstructions of the explanted spinal cord illustrated precise positioning and dimensions of the epidural leads in relation to the surrounding neuroanatomy, including the spinal rootlets of the dorsal and ventral columns of the spinal cord. In a separate swine cohort, implanted epidural leads were used for SCS and recording evoked ESRs. Results Reconstructed 3D-models of the swine spinal cord with epidural lead implants demonstrated considerable distinctions in the dimensions of a single electrode contact on a standard industry epidural stimulation lead compared to dorsal rootlets at the dorsal root entry zone (DREZ). At the intervertebral segment, it was observed that a single electrode contact may cover 20-25% of the DREZ if positioned laterally. Electrode contacts were estimated to be ~0.75 mm from the margins of the DREZ when placed at the midline. Furthermore, ventral rootlets were observed to travel in proximity and parallel to dorsal rootlets at this level prior to separation into their respective sides of the spinal cord. Cathodic stimulation at the level of the intervertebral disc, compared to an ‘off-disc’ stimulation (7 mm rostral), demonstrated considerable variations in the features of recorded ESRs, such as amplitude and shape, and evoked unintended motor activation at lower stimulation thresholds. This substantial change may be due to the influence of nearby ventral roots. To further illustrate the influence of rootlet activation vs. dorsal column activation, the stimulation lead was displaced laterally at ~2.88 mm from the midline, resulting in variances in both evoked compound action potential (ECAP) components and electromyography (EMG) components in ESRs at lower stimulation thresholds. Conclusion The results of this study suggest that the ECAP and EMG components of recorded ESRs can vary depending on small differences in the location of the stimulating electrodes within the spinal anatomy, such as at the level of the intervertebral segment. Furthermore, the effects of sub-centimeter lateral displacement of the stimulation lead from the midline, leading to significant changes in electrophysiological metrics. The results of this pilot study reveal the importance of the small displacement of the electrodes that can cause significant changes to evoked responses SCS. These results may provide further valuable insights into the underlying mechanisms and assist in optimizing future SCS-related applications.

2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2024

Stability Assessment of Ultramicroelectrode Arrays in Neural Stimulation: an Electrochemical Impedance Spectroscopy Analysis (opens in a new tab)

Qiwei Dong, Cynthia Ezeh, Yupeng Wu, … Kevin J. Otto

Abstract

The overall focus of this research program is to investigate the viability and safety of microelectrode arrays (MEAs) and ultramicroelectrode arrays (UMEAs) for microstimulation (µStim) in the brain. We aim to assess their potential to deliver adequate electrical stimulation for neural activation without causing electrode or tissue damage. To this end, here we conducted galvanostatic Electrochemical Impedance Spectroscopy (EIS) to assess the behavior of electrodes of various diameters both pre- and post-stimulation in a rat model. Our first-generation electrode arrays (G1) were designed with electrode diameters spanning 3 orders of magnitude and including subcellular dimensions. Using these devices, we delivered 0.4 nC/phase stimulation in vivo. We conducted in vitro EIS measurements before and after the current pulsing. Our findings show that these electrode arrays, including UMEAs, exhibit stable electrochemical behavior following a 0.4 nC/phase current pulse. To validate the EIS frequency range used for the G1 measurements, we designed a second-generation electrode array (G2) that included a terminating lead and a looping lead. This array provided the ability to assess the accuracy contour plot of our EIS system and electrode array platform. This exploratory research contributes to the ongoing knowledge of UMEAs in µStim applications. These developments may result in high-fidelity, non-damaging multichannel µStim, and improved neuromodulation technology for the treatment of neural diseases and injuries.

Scientific Reports · Jul 2024

Prediction of isometric forces from combined epidural spinal cord and neuromuscular electrical stimulation in the rat lower limb (opens in a new tab)

Daniel Song, Matthew C. Tresch

Abstract

Although epidural spinal cord and muscle stimulation have each been separately used for restoration of movement after spinal cord injury, their combined use has not been widely explored. Using both approaches in combination could provide more flexible control compared to using either approach alone, but whether responses evoked from such combined stimulation can be easily predicted is unknown. We evaluate whether responses evoked by combined spinal and muscle stimulation can be predicted simply, as the linear summation of responses produced by each type of stimulation individually. Should this be true, it would simplify the prediction of co-stimulation responses and the development of control schemes for spinal cord injury rehabilitation. In healthy anesthetized rats, we measured hindlimb isometric forces in response to spinal and muscle stimulation. Force prediction errors were calculated as the difference between predicted and observed co-stimulation forces. We found that spinal and muscle co-stimulation could be closely predicted as the linear summation of the individual spinal and muscle responses and that the errors were relatively low. We discuss the implications of these results to the use of combined muscle and spinal stimulation for the restoration of movement following spinal cord injury.

bioRxiv* · May 2024

Epidural Spinal Cord Recordings (ESRs): Sources of Artifact in Stimulation Evoked Compound Action Potentials (opens in a new tab)

Ashlesha Deshmukh, Megan L Settell, Kevin L Cheng, … Kip Ludwig

Abstract

Introduction: Evoked compound action potentials (ECAPs) measured using epidural spinal recordings (ESRs) during epidural spinal cord stimulation (SCS) can help elucidate fundamental mechanisms for the treatment of pain, as well as inform closed-loop control of SCS. Previous studies have used ECAPs to characterize the neural response to various neuromodulation therapies and have demonstrated that ECAPs are highly prone to multiple sources of artifact, including post-stimulus pulse capacitive artifact, electromyography (EMG) bleed-through, and motion artifact resulting from disturbance of the electrode/tissue interface during normal behavior. However, a thorough characterization has yet to be performed for how these sources of artifact may contaminate recordings within the temporal window commonly used to determine activation of A-beta fibers in a large animal model. Methods: We characterized the sources of artifacts that can contaminate the recording of ECAPs in an epidural SCS swine model using the Abbott Octrode™ lead. Muscle paralytics were administered to block muscle activation preventing EMG from contaminating the recorded ECAPs. Concurrent EMG recordings of the longissimus, a long muscle of the back, were used to confirm a 2-4 millisecond (ms) latency source of EMG bleed-through that frequently contaminated the A-beta temporal window. Additionally, we obtained recordings approximately 5-10 minutes post-mortem after clear evoked A-beta and associated EMG responses ceased to characterize the representation of stimulation artifact across the array. Results: Spinal ECAP recordings can be contaminated by capacitive artifact, short latency EMG from nearby long muscles of the back, and motion artifact from multiple sources. In many cases, the capacitive artifact can appear nearly identical in duration and waveshape to evoked A-beta responses. These sources of EMG can have phase shifts across the electrode array, very similar to the phase shift anticipated by propagation of an evoked A-beta fiber response across the array. This short latency EMG is often evident at currents similar to those needed to activate A-beta fibers associated with the treatment of pain. Changes in cerebrospinal fluid between the cord and dura, and motion induced during breathing created a cyclic oscillation in all evoked components of the recorded ECAP signal. Conclusion: Careful controls must be implemented to accurately separate neural signal from the sources of artifact in spinal cord ECAPs. To address this, we suggest experimental procedures and associated reporting requirements necessary to disambiguate the underlying neural response from these confounds. These data are important to better understand the conceptual framework for recorded ESRs, with components such as ECAPs, EMG responses and artifacts, and have important implications for closed-loop control algorithms to account for transient motion such as postural changes and cough.

bioRxiv* · May 2024

Hippocampal sharp wave ripples mediate generalization and subsequent fear attenuation via closed-loop brain stimulation in rats (opens in a new tab)

Pedraza LK, Sierra RO, Barcsai L, … Berenyi A

Abstract

The balance between stimulus generalization and discrimination is essential in modulating behavioral responses across different contexts. Excessive fear generalization is linked to neuropsychiatric disorders such as generalized anxiety disorder (GAD) and PTSD. While hippocampal sharp wave-ripples (SWRs) and concurrent neocortical oscillations are central to the consolidation of contextual memories, their involvement in non-hippocampal dependent memories remains poorly understood. Here we show that closed-loop disruption of SWRs, after the consolidation of a cued fear conditioning, leads to atypical memory discrimination that would normally be generalized. Furthermore, SWR-triggered closed-loop stimulation of the basolateral amygdala (BLA) during memory reconsolidation inhibits fear generalization and enhances subsequent extinction. Comparable effects were observed when stimulating the infralimbic cortex either post-training or after a brief memory reactivation. A consistent increase in gamma incidence within the amygdala was identified in animals subjected to closed-loop BLA or infralimbic cortex neuromodulation. Our findings highlight the functional role of hippocampal SWRs in modulating the qualitative aspects of amygdala-dependent memories. Targeting the amygdala activity via prefrontal cortex with closed-loop SWR triggered stimulation presents a potential foundation of a non-invasive therapy for GAD and PTSD.

Journal of Neural Engineering · Apr 2024

Activation and depression of neural and hemodynamic responses induced by the intracortical microstimulation and visual stimulation in the mouse visual cortex (opens in a new tab)

Naofumi Suematsu, Alberto L Vazquez, Takashi D Y Kozai

Abstract

Objective . Intracortical microstimulation (ICMS) can be an effective method for restoring sensory perception in contemporary brain–machine interfaces. However, the mechanisms underlying better control of neuronal responses remain poorly understood, as well as the relationship between neuronal activity and other concomitant phenomena occurring around the stimulation site. Approach . Different microstimulation frequencies were investigated in vivo on Thy1-GCaMP6s mice using widefield and two-photon imaging to evaluate the evoked excitatory neural responses across multiple spatial scales as well as the induced hemodynamic responses. Specifically, we quantified stimulation-induced neuronal activation and depression in the mouse visual cortex and measured hemodynamic oxyhemoglobin and deoxyhemoglobin signals using mesoscopic-scale widefield imaging. Main results . Our calcium imaging findings revealed a preference for lower-frequency stimulation in driving stronger neuronal activation. A depressive response following the neural activation preferred a slightly higher frequency stimulation compared to the activation. Hemodynamic signals exhibited a comparable spatial spread to neural calcium signals. Oxyhemoglobin concentration around the stimulation site remained elevated during the post-activation (depression) period. Somatic and neuropil calcium responses measured by two-photon microscopy showed similar dependence on stimulation parameters, although the magnitudes measured in soma was greater than in neuropil. Furthermore, higher-frequency stimulation induced a more pronounced activation in soma compared to neuropil, while depression was predominantly induced in soma irrespective of stimulation frequencies. Significance . These results suggest that the mechanism underlying depression differs from activation, requiring ample oxygen supply, and affecting neurons. Our findings provide a novel understanding of evoked excitatory neuronal activity induced by ICMS and offer insights into neuro-devices that utilize both activation and depression phenomena to achieve desired neural responses.

Scientific Reports · Mar 2024

Fractional order memcapacitive neuromorphic elements reproduce and predict neuronal function (opens in a new tab)

Patricia Vazquez-Guerrero, Rohisha Tuladhar, Costas Psychalinos, … Fidel Santamaria

Abstract

There is an increasing need to implement neuromorphic systems that are both energetically and computationally efficient. There is also great interest in using electric elements with memory, memelements, that can implement complex neuronal functions intrinsically. A feature not widely incorporated in neuromorphic systems is history-dependent action potential time adaptation which is widely seen in real cells. Previous theoretical work shows that power-law history dependent spike time adaptation, seen in several brain areas and species, can be modeled with fractional order differential equations. Here, we show that fractional order spiking neurons can be implemented using super-capacitors. The super-capacitors have fractional order derivative and memcapacitive properties. We implemented two circuits, a leaky integrate and fire and a Hodgkin–Huxley. Both circuits show power-law spiking time adaptation and optimal coding properties. The spiking dynamics reproduced previously published computer simulations. However, the fractional order Hodgkin–Huxley circuit showed novel dynamics consistent with criticality. We compared the responses of this circuit to recordings from neurons in the weakly-electric fish that have previously been shown to perform fractional order differentiation of their sensory input. The criticality seen in the circuit was confirmed in spontaneous recordings in the live fish. Furthermore, the circuit also predicted long-lasting stimulation that was also corroborated experimentally. Our work shows that fractional order memcapacitors provide intrinsic memory dependence that could allow implementation of computationally efficient neuromorphic devices. Memcapacitors are static elements that consume less energy than the most widely studied memristors, thus allowing the realization of energetically efficient neuromorphic devices.

eLife · Mar 2024

Heterosynaptic plasticity of the visuo-auditory projection requires cholecystokinin released from entorhinal cortex afferents (opens in a new tab)

Wenjian Sun, Haohao Wu, Yujie Peng, … Jufang He

Abstract

The entorhinal cortex is involved in establishing enduring visuo-auditory associative memory in the neocortex. Here we explored the mechanisms underlying this synaptic plasticity related to projections from the visual and entorhinal cortices to the auditory cortex in mice using optogenetics of dual pathways. High-frequency laser stimulation (HFS laser) of the visuo-auditory projection did not induce long-term potentiation. However, after pairing with sound stimulus, the visuo-auditory inputs were potentiated following either infusion of cholecystokinin (CCK) or HFS laser of the entorhino-auditory CCK-expressing projection. Combining retrograde tracing and RNAscope in situ hybridization, we show that Cck expression is higher in entorhinal cortex neurons projecting to the auditory cortex than in those originating from the visual cortex. In the presence of CCK, potentiation in the neocortex occurred when the presynaptic input arrived 200 ms before postsynaptic firing, even after just five trials of pairing. Behaviorally, inactivation of the CCK + projection from the entorhinal cortex to the auditory cortex blocked the formation of visuo-auditory associative memory. Our results indicate that neocortical visuo-auditory association is formed through heterosynaptic plasticity, which depends on release of CCK in the neocortex mostly from entorhinal afferents.

STAR Protocols · Mar 2024

Gaussian-process-based Bayesian optimization for neurostimulation interventions in rats (opens in a new tab)

Léo Choinière, Rose Guay-Hottin, Rémi Picard, … Numa Dancause

Abstract

Effective neural stimulation requires adequate parametrization. Gaussian-process (GP)-based Bayesian optimization (BO) offers a framework to discover optimal stimulation parameters in real time. Here, we first provide a general protocol to deploy this framework in neurostimulation interventions and follow by exemplifying its use in detail. Specifically, we describe the steps to implant rats with multi-channel electrode arrays in the hindlimb motor cortex. We then detail how to utilize the GP-BO algorithm to maximize evoked target movements, measured as electromyographic responses. For complete details on the use and execution of this protocol, please refer to Bonizzato and colleagues (2023).1.

Micromachines · Feb 2024

Using Compound Neural Action Potentials for Functional Validation of a High-Density Intraneural Interface: A Preliminary Study (opens in a new tab)

Aritra Kundu, Erin Patrick, Seth Currlin, … Rizwan Bashirullah

Abstract

Compound nerve action potentials (CNAPs) were used as a metric to assess the stimulation performance of a novel high-density, transverse, intrafascicular electrode in rat models. We show characteristic CNAPs recorded from distally implanted cuff electrodes. Evaluation of the CNAPs as a function of stimulus current and calculation of recruitment plots were used to obtain a qualitative approximation of the neural interface’s placement and orientation inside the nerve. This method avoids elaborate surgeries required for the implantation of EMG electrodes and thus minimizes surgical complications and may accelerate the healing process of the implanted subject.

bioRxiv* · Feb 2024

SAFE-OPT: A Bayesian optimization algorithm for learning optimal deep brain stimulation parameters with safety constraints (opens in a new tab)

Eric R. Cole, Mark J. Connolly, Mihir Ghetiya, … Robert E. Gross

Abstract

To treat neurological and psychiatric diseases with deep brain stimulation, a trained clinician must select parameters for each patient by monitoring their symptoms and side-effects in a months-long trial-and-error process, delaying optimal clinical outcomes. Bayesian optimization has been proposed as an efficient method to quickly and automatically search for optimal parameters. However, conventional Bayesian optimization does not account for patient safety and could trigger unwanted or dangerous side-effects. In this study we develop SAFE-OPT, a Bayesian optimization algorithm designed to learn subject-specific safety constraints to avoid potentially harmful stimulation settings during optimization. We prototype and validate SAFE-OPT using a rodent multielectrode stimulation paradigm which causes subject-specific performance deficits in a spatial memory task. We first use data from an initial cohort of subjects to build a simulation where we design the best SAFE-OPT configuration for safe and accurate searching in silico . We then deploy both SAFE-OPT and conventional Bayesian optimization in new subjects in vivo , showing that SAFE-OPT can find an optimally high stimulation amplitude that does not harm task performance with comparable sample efficiency to Bayesian optimization and without selecting amplitude values that exceed the subject’s safety threshold. The incorporation of safety constraints will provide a key step for adopting Bayesian optimization in real-world applications of deep brain stimulation.

Bioelectronic Medicine · Feb 2024

A soft, scalable and adaptable multi-contact cuff electrode for targeted peripheral nerve modulation (opens in a new tab)

Valentina Paggi, Florian Fallegger, Ludovic Serex, … Stéphanie P. Lacour

Abstract

Background Cuff electrodes target various nerves throughout the body, providing neuromodulation therapies for motor, sensory, or autonomic disorders. However, when using standard, thick silicone cuffs, fabricated in discrete circular sizes, complications may arise, namely cuff displacement or nerve compression, due to a poor adaptability to variable nerve shapes and sizes encountered in vivo. Improvements in cuff design, materials, closing mechanism and surgical approach are necessary to overcome these issues. Methods In this work, we propose a microfabricated multi-channel silicone-based soft cuff electrode with a novel easy-to-implant and size-adaptable design and evaluate a number of essential features such as nerve-cuff contact, nerve compression, cuff locking stability, long-term integration and stimulation selectivity. We also compared performance to that of standard fixed-size cuffs. Results The belt-like cuff made of 150 μm thick silicone membranes provides a stable and pressure-free conformal contact, independently of nerve size variability, combined with a straightforward implantation procedure. The adaptable design and use of soft materials lead to limited scarring and demyelination after 6-week implantation. In addition, multi-contact designs, ranging from 6 to 16 electrodes, allow for selective stimulation in models of rat and pig sciatic nerve, achieving targeted activation of up to 5 hindlimb muscles. Conclusion These results suggest a promising alternative to classic fixed-diameter cuffs and may facilitate the adoption of soft, adaptable cuffs in clinical settings.

* Preprint: not yet peer reviewed.