Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

742 papers

PLOS ONE · Jul 2017

Nanofibrous scaffolds for the guidance of stem cell-derived neurons for auditory nerve regeneration (opens in a new tab)

Sandra Hackelberg, Samuel J. Tuck, Long He, … R. Keith Duncan

Abstract

Impairment of spiral ganglion neurons (SGNs) of the auditory nerve is a major cause for hearing loss occurring independently or in addition to sensory hair cell damage. Unfortunately, mammalian SGNs lack the potential for autonomous regeneration. Stem cell based therapy is a promising approach for auditory nerve regeneration, but proper integration of exogenous cells into the auditory circuit remains a fundamental challenge. Here, we present novel nanofibrous scaffolds designed to guide the integration of human stem cell-derived neurons in the internal auditory meatus (IAM), the foramen allowing passage of the spiral ganglion to the auditory brainstem. Human embryonic stem cells (hESC) were differentiated into neural precursor cells (NPCs) and seeded onto aligned nanofiber mats. The NPCs terminally differentiated into glutamatergic neurons with high efficiency, and neurite projections aligned with nanofibers in vitro. Scaffolds were assembled by seeding GFP-labeled NPCs on nanofibers integrated in a polymer sheath. Biocompatibility and functionality of the NPC-seeded scaffolds were evaluated in vivo in deafened guinea pigs (Cavia porcellus). To this end, we established an ouabain-based deafening procedure that depleted an average 72% of SGNs from apex to base of the cochleae and caused profound hearing loss. Further, we developed a surgical procedure to implant seeded scaffolds directly into the guinea pig IAM. No evidence of an inflammatory response was observed, but post-surgery tissue repair appeared to be facilitated by infiltrating Schwann cells. While NPC survival was found to be poor, both subjects implanted with NPC-seeded and cell-free control scaffolds showed partial recovery of electrically-evoked auditory brainstem thresholds. Thus, while future studies must address cell survival, nanofibrous scaffolds pose a promising strategy for auditory nerve regeneration.

2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2017

Retinal electrostimulation in rats: Activation thresholds from superior colliculus and visual cortex recordings (opens in a new tab)

Alejandro Barriga-Rivera, Tianruo Guo, John W. Morley, … Gregg J. Suaning

Abstract

Retinal neuromodulation is an emerging therapeutic approach to restore functional vision to those suffering retinal photoreceptor degeneration. The retina encodes visual information and transmits it to the brain. Replicating this retinal code through electrical stimulation is essential to improving the performance of visual prostheses. In doing so, the first step relies on precise neural recordings from visual centers that allow studying the response of these neurons to electrical stimulation of the retina. This paper demonstrates the feasibility of a rat model to conduct highly reliable electrophysiological studies in the field of retinal neuromodulation. A disc electrode, implanted in the retrobulbar space was used to stimulate the retina of Long-Evans rats. Buzsaki multi-electro arrays were inserted in the superior colliculus (SC) to record electrical activity propagated from the retinal ganglion cells (RGCs). Activation thresholds calculated from local field potentials (visual cortex) and from neural spikes (SC) were contrasted. Both values were comparable to those in humans and in other animal models, and were slightly higher when estimated from SC recordings. However, differences were not statistically significant.

The Journal of Neuroscience · Jun 2017

A Test of the Stereausis Hypothesis for Sound Localization in Mammals (opens in a new tab)

Andrius Plauška, Marcel van der Heijden, J. Gerard G. Borst

Abstract

The relative arrival times of sounds at both ears constitute an important cue for localization of low-frequency sounds in the horizontal plane. The binaural neurons of the medial superior olive (MSO) act as coincidence detectors that fire when inputs from both ears arrive near simultaneously. Each principal neuron in the MSO is tuned to its own best interaural time difference (ITD), indicating the presence of an internal delay, a difference in the travel times from either ear to the MSO. According to the stereausis hypothesis, differences in wave propagation along the cochlea could provide the delays necessary for coincidence detection if the ipsilateral and contralateral inputs originated from different cochlear positions, with different frequency tuning. We therefore investigated the relation between interaural mismatches in frequency tuning and ITD tuning during in vivo loose-patch (juxtacellular) recordings from principal neurons of the MSO of anesthetized female gerbils. Cochlear delays can be bypassed by directly stimulating the auditory nerve; in agreement with the stereausis hypothesis, tuning for timing differences during bilateral electrical stimulation of the round windows differed markedly from ITD tuning in the same cells. Moreover, some neurons showed a frequency tuning mismatch that was sufficiently large to have a potential impact on ITD tuning. However, we did not find a correlation between frequency tuning mismatches and best ITDs. Our data thus suggest that axonal delays dominate ITD tuning.SIGNIFICANCE STATEMENT Neurons in the medial superior olive (MSO) play a unique role in sound localization because of their ability to compare the relative arrival time of low-frequency sounds at both ears. They fire maximally when the difference in sound arrival time exactly compensates for the internal delay: the difference in travel time from either ear to the MSO neuron. We tested whether differences in cochlear delay systematically contribute to the total travel time by comparing for individual MSO neurons the best difference in arrival times, as predicted from the frequency tuning for either ear, and the actual best difference. No systematic relation was observed, emphasizing the dominant contribution of axonal delays to the internal delay.

The Journal of Neuroscience · Jun 2017

Representations of Time-Varying Cochlear Implant Stimulation in Auditory Cortex of Awake Marmosets ( Callithrix jacchus ) (opens in a new tab)

Luke A. Johnson, Charles C. Della Santina, Xiaoqin Wang

Abstract

Electrical stimulation of the auditory periphery organ by cochlear implant (CI) generates highly synchronized inputs to the auditory system. It has long been thought such inputs would lead to highly synchronized neural firing along the ascending auditory pathway. However, neurophysiological studies with hearing animals have shown that the central auditory system progressively converts temporal representations of time-varying sounds to firing rate-based representations. It is not clear whether this coding principle also applies to highly synchronized CI inputs. Higher-frequency modulations in CI stimulation have been found to evoke largely transient responses with little sustained firing in previous studies of the primary auditory cortex (A1) in anesthetized animals. Here, we show that, in addition to neurons displaying synchronized firing to CI stimuli, a large population of A1 neurons in awake marmosets (Callithrix jacchus) responded to rapid time-varying CI stimulation with discharges that were not synchronized to CI stimuli, yet reflected changing repetition frequency by increased firing rate. Marmosets of both sexes were included in this study. By comparing directly each neuron's responses to time-varying acoustic and CI signals, we found that individual A1 neurons encode both modalities with similar firing patterns (stimulus-synchronized or nonsynchronized). These findings suggest that A1 neurons use the same basic coding schemes to represent time-varying acoustic or CI stimulation and provide new insights into mechanisms underlying how the brain processes natural sounds via a CI device.SIGNIFICANCE STATEMENT In modern cochlear implant (CI) processors, the temporal information in speech or environmental sounds is delivered through modulated electric pulse trains. How the auditory cortex represents temporally modulated CI stimulation across multiple time scales has remained largely unclear. In this study, we compared directly neuronal responses in primary auditory cortex (A1) to time-varying acoustic and CI signals in awake marmoset monkeys (Callithrix jacchus). We found that A1 neurons encode both modalities using similar coding schemes, but some important differences were identified. Our results provide insights into mechanisms underlying how the brain processes sounds via a CI device and suggest a candidate neural code underlying rate-pitch perception limitations often observed in CI users.

Frontiers in Neuroscience · May 2017

State-Dependent Decoding Algorithms Improve the Performance of a Bidirectional BMI in Anesthetized Rats (opens in a new tab)

Vito De Feo, Fabio Boi, Houman Safaai, … Alessandro Vato

Abstract

Brain-machine interfaces (BMIs) promise to improve the quality of life of patients suffering from sensory and motor disabilities by creating a direct communication channel between the brain and the external world. Yet, their performance is currently limited by the relatively small amount of information that can be decoded from neural activity recorded form the brain. We have recently proposed that such decoding performance may be improved when using state-dependent decoding algorithms that predict and discount the large component of the trial-to-trial variability of neural activity which is due to the dependence of neural responses on the network's current internal state. Here we tested this idea by using a bidirectional BMI to investigate the gain in performance arising from using a state-dependent decoding algorithm. This BMI, implemented in anesthetized rats, controlled the movement of a dynamical system using neural activity decoded from motor cortex and fed back to the brain the dynamical system's position by electrically microstimulating somatosensory cortex. We found that using state-dependent algorithms that tracked the dynamics of ongoing activity led to an increase in the amount of information extracted form neural activity by 22%, with a consequently increase in all of the indices measuring the BMI's performance in controlling the dynamical system. This suggests that state-dependent decoding algorithms may be used to enhance BMIs at moderate computational cost.

The Journal of Neuroscience · May 2017

Contrasting Modulatory Effects from the Dorsal and Ventral Premotor Cortex on Primary Motor Cortex Outputs (opens in a new tab)

Sandrine L. Côté, Adjia Hamadjida, Stephan Quessy, Numa Dancause

Abstract

The dorsal and ventral premotor cortices (PMd and PMv, respectively) each take part in unique aspects for the planning and execution of hand movements. These premotor areas are components of complex anatomical networks that include the primary motor cortex (M1) of both hemispheres. One way that PMd and PMv could play distinct roles in hand movements is by modulating the outputs of M1 differently. However, patterns of effects from PMd and PMv on the outputs of M1 have not been compared systematically. Our goals were to study how PMd within the same (i.e., ipsilateral or iPMd) and in the opposite hemisphere (i.e., contralateral or cPMd) can shape M1 outputs and then compare these effects with those induced by PMv. We used paired-pulse protocols with intracortical microstimulation techniques in sedated female cebus monkeys while recording EMG signals from intrinsic hand and forearm muscles. A conditioning stimulus was delivered in iPMd or cPMd concurrently or before a test stimulus in M1. The patterns of modulatory effects from PMd were compared with those from PMv collected in the same animals. Striking differences were revealed. Conditioning stimulation in iPMd induced more frequent and powerful inhibitory effects on M1 outputs compared with iPMv. In the opposite hemisphere, cPMd conditioning induced more frequent and powerful facilitatory effects than cPMv. These contrasting patterns of modulatory effects could allow PMd and PMv to play distinct functions for the control of hand movements and predispose them to undertake different, perhaps somewhat opposite, roles in motor recovery after brain injury.SIGNIFICANCE STATEMENT The dorsal and ventral premotor cortices (PMd and PMv, respectively) are two specialized areas involved in the control of hand movements in primates. One way that PMd and PMv could participate in hand movements is by modulating or shaping the primary motor cortex (M1) outputs to hand muscles. Here, we studied the patterns of modulation from PMd within the same and in the opposite hemisphere on the outputs of M1 and compared them with those from PMv. We found that PMd and PMv have strikingly different effects on M1 outputs. These contrasting patterns of modulation provide a substrate that may allow PMd and PMv to carry distinct functions for the preparation and execution of hand movements and for recovery after brain injury.

Frontiers in Behavioral Neuroscience · Apr 2017

Cycle-Triggered Cortical Stimulation during Slow Wave Sleep Facilitates Learning a BMI Task: A Case Report in a Non-Human Primate (opens in a new tab)

Irene Rembado, Stavros Zanos, Eberhard E. Fetz

Abstract

Slow wave sleep (SWS) has been identified as the sleep stage involved in consolidating newly acquired information. A growing body of evidence has shown that delta (1-4 Hz) oscillatory activity, the characteristic electroencephalographic signature of SWS, is involved in coordinating interaction between the hippocampus and the neocortex and is thought to take a role in stabilizing memory traces related to a novel task. This case report describes a new protocol that uses neuroprosthetics training of a non-human primate to evaluate the effects of surface cortical electrical stimulation triggered from SWS cycles. The results suggest that stimulation phase-locked to SWS oscillatory activity promoted learning of the neuroprosthetic task. This protocol could be used to elucidate mechanisms of synaptic plasticity underlying off-line learning during sleep and offers new insights into the role of brain oscillations in information processing and memory consolidation.

Frontiers in Neural Circuits · Apr 2017

High Spatiotemporal Resolution ECoG Recording of Somatosensory Evoked Potentials with Flexible Micro-Electrode Arrays (opens in a new tab)

Taro Kaiju, Keiichi Doi, Masashi Yokota, … Takafumi Suzuki

Abstract

Electrocorticogram (ECoG) has great potential as a source signal, especially for clinical BMI. Until recently, ECoG electrodes were commonly used for identifying epileptogenic foci in clinical situations, and such electrodes were low-density and large. Increasing the number and density of recording channels could enable the collection of richer motor/sensory information, and may enhance the precision of decoding and increase opportunities for controlling external devices. Several reports have aimed to increase the number and density of channels. However, few studies have discussed the actual validity of high-density ECoG arrays. In this study, we developed novel high-density flexible ECoG arrays and conducted decoding analyses with monkey somatosensory evoked potentials (SEPs). Using MEMS technology, we made 96-channel Parylene electrode arrays with an inter-electrode distance of 700 μm and recording site area of 350 μm2. The arrays were mainly placed onto the finger representation area in the somatosensory cortex of the macaque, and partially inserted into the central sulcus. With electrical finger stimulation, we successfully recorded and visualized finger SEPs with a high spatiotemporal resolution. We conducted offline analyses in which the stimulated fingers and intensity were predicted from recorded SEPs using a support vector machine. We obtained the following results: (1) Very high accuracy (~98%) was achieved with just a short segment of data (~15 ms from stimulus onset). (2) High accuracy (~96%) was achieved even when only a single channel was used. This result indicated placement optimality for decoding. (3) Higher channel counts generally improved prediction accuracy, but the efficacy was small for predictions with feature vectors that included time-series information. These results suggest that ECoG signals with high spatiotemporal resolution could enable greater decoding precision or external device control.

Frontiers in Neuroscience · Apr 2017

A Rodent Model of Dynamic Facial Reanimation Using Functional Electrical Stimulation (opens in a new tab)

Mark A. Attiah, Julius de Vries, Andrew G. Richardson, Timothy H. Lucas

Abstract

Facial paralysis can be a devastating condition, causing disfiguring facial droop, slurred speech, eye dryness, scarring and blindness. This study investigated the utility of closed-loop functional electric stimulation (FES) for reanimating paralyzed facial muscles in a quantitative rodent model. The right buccal and marginal mandibular branches of the rat facial nerve were transected for selective, unilateral paralysis of whisker muscles. Microwire electrodes were implanted bilaterally into the facial musculature for FES and electromyographic (EMG) recording. With the rats awake and head-fixed, whisker trajectories were tracked bilaterally with optical micrometers. First, the relationship between EMG and volitional whisker movement was quantified on the intact side of the face. Second, the effect of FES on whisker trajectories was quantified on the paralyzed side. Third, closed-loop experiments were performed in which the EMG signal on the intact side triggered FES on the paralyzed side to restore symmetric whisking. The results demonstrate a novel in vivo platform for developing control strategies for neuromuscular facial prostheses.

Cortex · Apr 2017

Paradoxical vocal changes in a trained singer by focally cooling the right superior temporal gyrus (opens in a new tab)

Kalman A. Katlowitz, Hiroyuki Oya, Matthew A. Howard, … Michael A. Long

Abstract

The production and perception of music is preferentially mediated by cortical areas within the right hemisphere, but little is known about how these brain regions individually contribute to this process. In an experienced singer undergoing awake craniotomy, we demonstrated that direct electrical stimulation to a portion of the right posterior superior temporal gyrus (pSTG) selectively interrupted singing but not speaking. We then focally cooled this region to modulate its activity during vocalization. In contrast to similar manipulations in left hemisphere speech production regions, pSTG cooling did not elicit any changes in vocal timing or quality. However, this manipulation led to an increase in the pitch of speaking with no such change in singing. Further analysis revealed that all vocalizations exhibited a cooling-induced increase in the frequency of the first formant, raising the possibility that potential pitch offsets may have been actively avoided during singing. Our results suggest that the right pSTG plays a key role in vocal sensorimotor processing whose impact is dependent on the type of vocalization produced.

Journal of the Association for Research in Otolaryngology · Mar 2017

Acoustic Context Alters Vowel Categorization in Perception of Noise-Vocoded Speech (opens in a new tab)

Christian E. Stilp

Abstract

Normal-hearing listeners' speech perception is widely influenced by spectral contrast effects (SCEs), where perception of a given sound is biased away from stable spectral properties of preceding sounds. Despite this influence, it is not clear how these contrast effects affect speech perception for cochlear implant (CI) users whose spectral resolution is notoriously poor. This knowledge is important for understanding how CIs might better encode key spectral properties of the listening environment. Here, SCEs were measured in normal-hearing listeners using noise-vocoded speech to simulate poor spectral resolution. Listeners heard a noise-vocoded sentence where low-F1 (100-400 Hz) or high-F1 (550-850 Hz) frequency regions were amplified to encourage "eh" (/ɛ/) or "ih" (/ɪ/) responses to the following target vowel, respectively. This was done by filtering with +20 dB (experiment 1a) or +5 dB gain (experiment 1b) or filtering using 100 % of the difference between spectral envelopes of /ɛ/ and /ɪ/ endpoint vowels (experiment 2a) or only 25 % of this difference (experiment 2b). SCEs influenced identification of noise-vocoded vowels in each experiment at every level of spectral resolution. In every case but one, SCE magnitudes exceeded those reported for full-spectrum speech, particularly when spectral peaks in the preceding sentence were large (+20 dB gain, 100 % of the spectral envelope difference). Even when spectral resolution was insufficient for accurate vowel recognition, SCEs were still evident. Results are suggestive of SCEs influencing CI users' speech perception as well, encouraging further investigation of CI users' sensitivity to acoustic context.

The Journal of the Acoustical Society of America · Mar 2017

Binaural pitch fusion: Comparison of normal-hearing and hearing-impaired listeners (opens in a new tab)

Lina A. J. Reiss, Corey S. Shayman, Emily P. Walker, … Yonghee Oh

Abstract

Binaural pitch fusion is the fusion of dichotically presented tones that evoke different pitches between the ears. In normal-hearing (NH) listeners, the frequency range over which binaural pitch fusion occurs is usually <0.2 octaves. Recently, broad fusion ranges of 1–4 octaves were demonstrated in bimodal cochlear implant users. In the current study, it was hypothesized that hearing aid (HA) users would also exhibit broad fusion. Fusion ranges were measured in both NH and hearing-impaired (HI) listeners with hearing losses ranging from mild-moderate to severe-profound, and relationships of fusion range with demographic factors and with diplacusis were examined. Fusion ranges of NH and HI listeners averaged 0.17 ± 0.13 octaves and 1.7 ± 1.5 octaves, respectively. In HI listeners, fusion ranges were positively correlated with a principal component measure of the covarying factors of young age, early age of hearing loss onset, and long durations of hearing loss and HA use, but not with hearing threshold, amplification level, or diplacusis. In NH listeners, no correlations were observed with age, hearing threshold, or diplacusis. The association of broad fusion with early onset, long duration of hearing loss suggests a possible role of long-term experience with hearing loss and amplification in the development of broad fusion.

Experimental Neurology · Mar 2017

Parametric characterization of neural activity in the locus coeruleus in response to vagus nerve stimulation (opens in a new tab)

Daniel R. Hulsey, Jonathan R. Riley, Kristofer W. Loerwald, … Seth A. Hays

Abstract

Vagus nerve stimulation (VNS) has emerged as a therapy to treat a wide range of neurological disorders, including epilepsy, depression, stroke, and tinnitus. Activation of neurons in the locus coeruleus (LC) is believed to mediate many of the effects of VNS in the central nervous system. Despite the importance of the LC, there is a dearth of direct evidence characterizing neural activity in response to VNS. A detailed understanding of the brain activity evoked by VNS across a range of stimulation parameters may guide selection of stimulation regimens for therapeutic use. In this study, we recorded neural activity in the LC and the mesencephalic trigeminal nucleus (Me5) in response to VNS over a broad range of current amplitudes, pulse frequencies, train durations, inter-train intervals, and pulse widths. Brief 0.5s trains of VNS drive rapid, phasic firing of LC neurons at 0.1mA. Higher current intensities and longer pulse widths drive greater increases in LC firing rate. Varying the pulse frequency substantially affects the timing, but not the total amount, of phasic LC activity. VNS drives pulse-locked neural activity in the Me5 at current levels above 1.2mA. These results provide insight into VNS-evoked phasic neural activity in multiple neural structures and may be useful in guiding the selection of VNS parameters to enhance clinical efficacy.

Scientific Reports · Feb 2017

High-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis (opens in a new tab)

Alejandro Barriga-Rivera, Tianruo Guo, Chih-Yu Yang, … Gregg J. Suaning

Abstract

Retinal electrostimulation is promising a successful therapy to restore functional vision. However, a narrow stimulating current range exists between retinal neuron excitation and inhibition which may lead to misperformance of visual prostheses. As the conveyance of representation of complex visual scenes may require neighbouring electrodes to be activated simultaneously, electric field summation may contribute to reach this inhibitory threshold. This study used three approaches to assess the implications of relatively high stimulating conditions in visual prostheses: (1) in vivo , using a suprachoroidal prosthesis implanted in a feline model, (2) in vitro through electrostimulation of murine retinal preparations, and (3) in silico by computing the response of a population of retinal ganglion cells. Inhibitory stimulating conditions led to diminished cortical activity in the cat. Stimulus-response relationships showed non-monotonic profiles to increasing stimulating current. This was observed in vitro and in silico as the combined response of groups of neurons (close to the stimulating electrode) being inhibited at certain stimulating amplitudes, whilst other groups (far from the stimulating electrode) being recruited. These findings may explain the halo-like phosphene shapes reported in clinical trials and suggest that simultaneous stimulation in retinal prostheses is limited by the inhibitory threshold of the retinal ganglion cells.

Human Brain Mapping · Jan 2017

The human subthalamic nucleus and globus pallidus internus differentially encode reward during action control (opens in a new tab)

Peter Justin Rossi, Corinna Peden, Oscar Castellanos, … Michael S. Okun

Abstract

The subthalamic nucleus (STN) and globus pallidus internus (GPi) have recently been shown to encode reward, but few studies have been performed in humans. We investigated STN and GPi encoding of reward and loss (i.e., valence) in humans with Parkinson's disease. To test the hypothesis that STN and GPi neurons would change their firing rate in response to reward‐ and loss‐related stimuli, we recorded the activity of individual neurons while participants performed a behavioral task. In the task, action choices were associated with potential rewarding, punitive, or neutral outcomes. We found that STN and GPi neurons encode valence‐related information during action control, but the proportion of valence‐responsive neurons was greater in the STN compared to the GPi. In the STN, reward‐related stimuli mobilized a greater proportion of neurons than loss‐related stimuli. We also found surprising limbic overlap with the sensorimotor regions in both the STN and GPi, and this overlap was greater than has been previously reported. These findings may help to explain alterations in limbic function that have been observed following deep brain stimulation therapy of the STN and GPi. Hum Brain Mapp 38:1952–1964, 2017 . © 2017 Wiley Periodicals, Inc.

The Journal of Neuroscience · Jan 2017

Electrical Microstimulation of the Pulvinar Biases Saccade Choices and Reaction Times in a Time-Dependent Manner (opens in a new tab)

Adan-Ulises Dominguez-Vargas, Lukas Schneider, Melanie Wilke, Igor Kagan

Abstract

The pulvinar complex is interconnected extensively with brain regions involved in spatial processing and eye movement control. Recent inactivation studies have shown that the dorsal pulvinar (dPul) plays a role in saccade target selection; however, it remains unknown whether it exerts effects on visual processing or at planning/execution stages. We used electrical microstimulation of the dPul while monkeys performed saccade tasks toward instructed and freely chosen targets. Timing of stimulation was varied, starting before, at, or after onset of target(s). Stimulation affected saccade properties and target selection in a time-dependent manner. Stimulation starting before but overlapping with target onset shortened saccadic reaction times (RTs) for ipsiversive (to the stimulation site) target locations, whereas stimulation starting at and after target onset caused systematic delays for both ipsiversive and contraversive locations. Similarly, stimulation starting before the onset of bilateral targets increased ipsiversive target choices, whereas stimulation after target onset increased contraversive choices. Properties of dPul neurons and stimulation effects were consistent with an overall contraversive drive, with varying outcomes contingent upon behavioral demands. RT and choice effects were largely congruent in the visually-guided task, but stimulation during memory-guided saccades, while influencing RTs and errors, did not affect choice behavior. Together, these results show that the dPul plays a primary role in action planning as opposed to visual processing, that it exerts its strongest influence on spatial choices when decision and action are temporally close, and that this choice effect can be dissociated from motor effects on saccade initiation and execution. SIGNIFICANCE STATEMENT Despite a recent surge of interest, the core function of the pulvinar, the largest thalamic complex in primates, remains elusive. This understanding is crucial given the central role of the pulvinar in current theories of integrative brain functions supporting cognition and goal-directed behaviors, but electrophysiological and causal interference studies of dorsal pulvinar (dPul) are rare. Building on our previous studies that pharmacologically suppressed dPul activity for several hours, here we used transient electrical microstimulation at different periods while monkeys performed instructed and choice eye movement tasks, to determine time-specific contributions of pulvinar to saccade generation and decision making. We show that stimulation effects depend on timing and behavioral state and that effects on choices can be dissociated from motor effects.

Scientific Reports · Jan 2017

Highly Stable Glassy Carbon Interfaces for Long-Term Neural Stimulation and Low-Noise Recording of Brain Activity (opens in a new tab)

Maria Vomero, Elisa Castagnola, Francesca Ciarpella, … Davide Ricci

Abstract

We report on the superior electrochemical properties, in-vivo performance and long term stability under electrical stimulation of a new electrode material fabricated from lithographically patterned glassy carbon. For a direct comparison with conventional metal electrodes, similar ultra-flexible, micro-electrocorticography (μ-ECoG) arrays with platinum (Pt) or glassy carbon (GC) electrodes were manufactured. The GC microelectrodes have more than 70% wider electrochemical window and 70% higher CTC (charge transfer capacity) than Pt microelectrodes of similar geometry. Moreover, we demonstrate that the GC microelectrodes can withstand at least 5 million pulses at 0.45 mC/cm 2 charge density with less than 7.5% impedance change, while the Pt microelectrodes delaminated after 1 million pulses. Additionally, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) was selectively electrodeposited on both sets of devices to specifically reduce their impedances for smaller diameters (<60 μm). We observed that PEDOT-PSS adhered significantly better to GC than Pt, and allowed drastic reduction of electrode size while maintaining same amount of delivered current. The electrode arrays biocompatibility was demonstrated through in-vitro cell viability experiments, while acute in vivo characterization was performed in rats and showed that GC microelectrode arrays recorded somatosensory evoked potentials (SEP) with an almost twice SNR (signal-to-noise ratio) when compared to the Pt ones.

bioRxiv · Jan 2017

Transcranial alternating current stimulation with speech envelopes modulates speech comprehension (opens in a new tab)

Anna Wilsch, Toralf Neuling, Jonas Obleser, Christoph S. Herrmann

Abstract

Cortical entrainment of the auditory cortex to the broadband temporal envelope of a speech signal is crucial for speech comprehension. Entrainment results in phases of high and low neural excitability, which structure and decode the incoming speech signal. Entrainment to speech is strongest in the theta frequency range (4–8 Hz), the average frequency of the speech envelope. If a speech signal is degraded, entrainment to the speech envelope is weaker and speech intelligibility declines. Besides perceptually evoked cortical entrainment, transcranial alternating current stimulation (tACS) entrains neural oscillations by applying an electric signal to the brain. Accordingly, tACS-induced entrainment in auditory cortex has been shown to improve auditory perception. The aim of the current study was to modulate speech intelligibility externally by means of tACS such that the electric current corresponds to the envelope of the presented speech stream (i.e., envelope-tACS). Participants performed the Oldenburg sentence test with sentences presented in noise in combination with envelope-tACS. Critically, tACS was induced at time lags of 0 to 250 ms in 50-ms steps relative to sentence onset (auditory stimuli were simultaneous to or preceded tACS). We performed single-subject sinusoidal, linear, and quadratic fits to the sentence comprehension performance across the time lags. We could show that the sinusoidal fit described the modulation of sentence comprehension best. Importantly, the average frequency of the sinusoidal fit was 5.12 Hz, corresponding to the peaks of the amplitude spectrum of the stimulated envelopes. This finding was supported by a significant 5-Hz peak in the average power spectrum of individual performance time series. Altogether, envelope tACS modulates intelligibility of speech in noise, presumably by enhancing and disrupting (time lag with in-or out-of-phase stimulation, respectively) cortical entrainment to the speech envelope in auditory cortex.

Ear & Hearing · 2017

Lateralization of Interaural Level Differences with Multiple Electrode Stimulation in Bilateral Cochlear-Implant Listeners (opens in a new tab)

Olga A. Stakhovskaya, Matthew J. Goupell

Abstract

Objective: There is currently no accepted method of mapping bilateral cochlear-implant (BiCI) users to maximize binaural performance, but the current approach of mapping one ear at a time could produce spatial perceptions that are not consistent with a sound’s physical location in space. The goal of this study was to investigate the perceived intracranial lateralization of bilaterally synchronized electrical stimulation with a range of interaural level differences (ILDs) and to determine a method to produce relatively more centered auditory images when provided multielectrode stimulation. Design: Using direct stimulation, lateralization curves were measured in nine BiCI listeners using 1000-pulses per second (pps), 500-msec constant-amplitude pulse trains with ILDs that ranged from −20 to +20 clinical current units (CUs). The stimuli were presented bilaterally at 70 to 80% of the dynamic range on single or multiple electrode pairs. For the multielectrode pairs, the ILD was applied consistently across all the pairs. The lateralization response range and the bias magnitude at 0 CU ILD (i.e., the number of CUs needed to produce a centered auditory image) were computed. Then the levels that elicit a centered auditory image with single-electrode stimulation were used with multielectrode stimulation to determine if this produced fewer significant biases at 0 CU ILD. Lastly, a multichannel ILD processing model was used to predict lateralization for the multielectrode stimulation from the single-electrode stimulation. Results: BiCI listeners often perceived both single- and multielectrode stimulation at 0-CU ILD as not intracranially centered. For single-electrode stimulation, 44% of the lateralization curves had relatively large (≥5 CU) bias magnitudes. For the multielectrode stimulation, 25% of the lateralization curves had large bias magnitudes. After centering the single-electrode pairs, the percentage of multielectrode combinations that produced large biases significantly decreased to only 4% ( p < 0.001, McNemar’s test). The lateralization with multielectrode stimulation was well predicted by a model that used unweighted or weighted average single-electrode lateralization percepts across electrode pairs (87 or 90%, respectively). Conclusion: Current BiCI mapping procedures can produce an inconsistent association between a physical ILD and the perceived location across electrodes for both single- and multielectrode stimulation. Explicit centering of single-electrode pairs using the perceived centered intracranial location almost entirely corrects this problem and such an approach is supported by our understanding and model of across-frequency ILD processing. Such adjustments might be achieved by clinicians using single-electrode binaural comparisons. Binaural abilities, like sound localization and understanding speech in noise, may be improved if these across-electrode perceptual inconsistencies are removed.

Journal of Neurosurgery · 2017

Intraoperative electrocorticography for physiological research in movement disorders: principles and experience in 200 cases (opens in a new tab)

Fedor Panov, Emily Levin, Coralie de Hemptinne, … Philip A. Starr

Abstract

OBJECTIVE Contemporary theories of the pathophysiology of movement disorders emphasize abnormal oscillatory activity in basal ganglia-thalamocortical loops, but these have been studied in humans mainly using depth recordings. Recording from the surface of the cortex using electrocorticography (ECoG) provides a much higher amplitude signal than depth recordings, is less susceptible to deep brain stimulation (DBS) artifacts, and yields a surrogate measure of population spiking via “broadband gamma” (50–200 Hz) activity. Therefore, a technical approach to movement disorders surgery was developed that employs intraoperative ECoG as a research tool. METHODS One hundred eighty-eight patients undergoing DBS for the treatment of movement disorders were studied under an institutional review board–approved protocol. Through the standard bur hole exposure that is clinically indicated for DBS lead insertion, a strip electrode (6 or 28 contacts) was inserted to cover the primary motor or prefrontal cortical areas. Localization was confirmed by the reversal of the somatosensory evoked potential and intraoperative CT or 2D fluoroscopy. The ECoG potentials were recorded at rest and during a variety of tasks and analyzed offline in the frequency domain, focusing on activity between 3 and 200 Hz. Strips were removed prior to closure. Postoperative MRI was inspected for edema, signal change, or hematoma that could be related to the placement of the ECoG strip. RESULTS One hundred ninety-eight (99%) strips were successfully placed. Two ECoG placements were aborted due to resistance during the attempted passage of the electrode. Perioperative surgical complications occurred in 8 patients, including 5 hardware infections, 1 delayed chronic subdural hematoma requiring evacuation, 1 intraparenchymal hematoma, and 1 venous infarction distant from the site of the recording. None of these appeared to be directly related to the use of ECoG. CONCLUSIONS Intraoperative ECoG has long been used in neurosurgery for functional mapping and localization of seizure foci. As applied during DBS surgery, it has become an important research tool for understanding the brain networks in movement disorders and the mechanisms of therapeutic stimulation. In experienced hands, the technique appears to add minimal risk to surgery.