Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

742 papers

Proceedings of the National Academy of Sciences · Dec 2016

Ownership of an artificial limb induced by electrical brain stimulation (opens in a new tab)

Kelly L. Collins, Arvid Guterstam, Jeneva Cronin, … Jeffrey G. Ojemann

Abstract

Significance Creating a prosthetic device that feels like one’s own limb is a major challenge in applied neuroscience. We show that ownership of an artificial hand can be induced via electrical stimulation of the hand somatosensory cortex in synchrony with touches applied to a prosthetic hand in full view. These findings suggest that the human brain can integrate “natural” visual input and direct cortical-somatosensory stimulation to create the multisensory perception that an artificial limb belongs to one’s own body.

Frontiers in Neuroscience · Dec 2016

A Bidirectional Brain-Machine Interface Featuring a Neuromorphic Hardware Decoder (opens in a new tab)

Fabio Boi, Timoleon Moraitis, Vito De Feo, … Alessandro Vato

Abstract

Bidirectional brain-machine interfaces (BMIs) establish a two-way direct communication link between the brain and the external world. A decoder translates recorded neural activity into motor commands and an encoder delivers sensory information collected from the environment directly to the brain creating a closed-loop system. These two modules are typically integrated in bulky external devices. However, the clinical support of patients with severe motor and sensory deficits requires compact, low-power, and fully implantable systems that can decode neural signals to control external devices. As a first step toward this goal, we developed a modular bidirectional BMI setup that uses a compact neuromorphic processor as a decoder. On this chip we implemented a network of spiking neurons built using its ultra-low-power mixed-signal analog/digital circuits. On-chip on-line spike-timing-dependent plasticity synapse circuits enabled the network to learn to decode neural signals recorded from the brain into motor outputs controlling the movements of an external device. The modularity of the BMI allowed us to tune the individual components of the setup without modifying the whole system. In this paper, we present the features of this modular BMI and describe how we configured the network of spiking neuron circuits to implement the decoder and to coordinate it with the encoder in an experimental BMI paradigm that connects bidirectionally the brain of an anesthetized rat with an external object. We show that the chip learned the decoding task correctly, allowing the interfaced brain to control the object's trajectories robustly. Based on our demonstration, we propose that neuromorphic technology is mature enough for the development of BMI modules that are sufficiently low-power and compact, while being highly computationally powerful and adaptive.

The Journal of Neuroscience · Dec 2016

Selective Neuronal Activation by Cochlear Implant Stimulation in Auditory Cortex of Awake Primate (opens in a new tab)

Luke A. Johnson, Charles C. Della Santina, Xiaoqin Wang

Abstract

Despite the success of cochlear implants (CIs) in human populations, most users perform poorly in noisy environments and music and tonal language perception. How CI devices engage the brain at the single neuron level has remained largely unknown, in particular in the primate brain. By comparing neuronal responses with acoustic and CI stimulation in marmoset monkeys unilaterally implanted with a CI electrode array, we discovered that CI stimulation was surprisingly ineffective at activating many neurons in auditory cortex, particularly in the hemisphere ipsilateral to the CI. Further analyses revealed that the CI-nonresponsive neurons were narrowly tuned to frequency and sound level when probed with acoustic stimuli; such neurons likely play a role in perceptual behaviors requiring fine frequency and level discrimination, tasks that CI users find especially challenging. These findings suggest potential deficits in central auditory processing of CI stimulation and provide important insights into factors responsible for poor CI user performance in a wide range of perceptual tasks. SIGNIFICANCE STATEMENT The cochlear implant (CI) is the most successful neural prosthetic device to date and has restored hearing in hundreds of thousands of deaf individuals worldwide. However, despite its huge successes, CI users still face many perceptual limitations, and the brain mechanisms involved in hearing through CI devices remain poorly understood. By directly comparing single-neuron responses to acoustic and CI stimulation in auditory cortex of awake marmoset monkeys, we discovered that neurons unresponsive to CI stimulation were sharply tuned to frequency and sound level. Our results point out a major deficit in central auditory processing of CI stimulation and provide important insights into mechanisms underlying the poor CI user performance in a wide range of perceptual tasks.

Frontiers in Bioengineering and Biotechnology · Dec 2016

Discriminability of Single and Multichannel Intracortical Microstimulation within Somatosensory Cortex (opens in a new tab)

Cynthia K. Overstreet, Randall B. Hellman, Ruben D. Ponce Wong, … Stephen I. Helms Tillery

Abstract

The addition of tactile and proprioceptive feedback to neuroprosthetic limbs is expected to significantly improve the control of these devices. Intracortical microstimulation (ICMS) of somatosensory cortex is a promising method of delivering this sensory feedback. To date, the main focus of somatosensory ICMS studies has been to deliver discriminable signals, corresponding to varying intensity, to a single location in cortex. However, multiple independent and simultaneous streams of sensory information will need to be encoded by ICMS to provide functionally relevant feedback for a neuroprosthetic limb (e.g., encoding contact events and pressure on multiple digits). In this study, we evaluated the ability of an awake, behaving non-human primate (Macaca mulatta) to discriminate ICMS stimuli delivered on multiple electrodes spaced within somatosensory cortex. We delivered serial stimulation on single electrodes to evaluate the discriminability of sensations corresponding to ICMS of distinct cortical locations. Additionally, we delivered trains of multichannel stimulation, derived from a tactile sensor, synchronously across multiple electrodes. Our results indicate that discrimination of multiple ICMS stimuli is a challenging task, but that discriminable sensory percepts can be elicited by both single and multichannel ICMS on electrodes spaced within somatosensory cortex.

Journal of the Association for Research in Otolaryngology · Dec 2016

Simultaneous Intracochlear Pressure Measurements from Two Cochlear Locations: Propagation of Distortion Products in Gerbil (opens in a new tab)

Wei Dong

Abstract

Sound energy propagates in the cochlea through a forward-traveling or slow wave supported by the cochlear partition and fluid inertia. Additionally, cochlear models support traveling wave propagation in the reverse direction as the expected mechanism for conveying otoacoustic emissions out of the cochlea. Recently, however, this hypothesis has been questioned, casting doubt on the process by which otoacoustic emissions travel back out through the cochlea. The proposed alternative reverse travel path for emissions is directly through the fluids of the cochlea as a compression pressure in the form of a fast wave. In the present study, a custom-made micro-pressure sensor was used in vivo in the gerbil cochlea to map two-tone-evoked pressure responses at distinct longitudinal and vertical locations in both the scala tympani and scala vestibuli. Analyses of the magnitude and phase of intracochlear pressure responses at the primary tone and distortion product frequencies were used to distinguish between fast and slow waves in both the forward- and reverse-propagation directions. Results demonstrated that distortion products may travel in both forward and reverse directions post-generation and the existence of both traveling and compression waves. The forward-traveling component appeared to duplicate the process of any external tone, tuned to the local characteristic-frequency place, as it increased compressively and nonlinearly with primary-tone levels. A compression wave was evidenced at frequencies above the cutoff of the recording site. In the opposite direction, a reverse-traveling wave played the major role in driving the stapes reversely and contributed to the distortion product otoacoustic emission. The compression wave may also play a role in reverse propagation when distortion products are generated at a region close to the stapes.

Neuron · Dec 2016

Linking Electrical Stimulation of Human Primary Visual Cortex, Size of Affected Cortical Area, Neuronal Responses, and Subjective Experience (opens in a new tab)

Jonathan Winawer, Josef Parvizi

Abstract

Electrical brain stimulation (EBS) complements neural measurements by probing the causal relationship between brain and perception, cognition, and action. Many fundamental questions about EBS remain unanswered, including the spatial extent of cortex responsive to stimulation, and the relationship between the circuitry engaged by EBS and the types of neural responses elicited by sensory stimulation. Here, we measured neural responses and the effects of EBS in primary visual cortex in four patients implanted with intracranial electrodes. Using stimulation, behavior, and retinotopic mapping, we show the relationship between the size of affected cortical area and the magnitude of electrical charge. Furthermore, we show that the spatial location of electrically induced visual sensations is matched to the receptive field of the cortical site measured with broadband field potentials, and less so with event related potentials. Together, these findings broaden our knowledge about the mechanism of EBS and the neuromodulation of the human brain.

Otology & Neurotology · Dec 2016

Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion (opens in a new tab)

Nathaniel T. Greene, Jameson K. Mattingly, Renee M. Banakis Hartl, … Stephen P. Cass

Abstract

Hypothesis: Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high-intensity sound transients. Background: Many patients receiving a CI have some remaining functional hearing at low frequencies; thus, devices and surgical techniques have been developed to use this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low-frequency hearing is lost after CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Methods: Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli and tympani were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows, whereas CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Results: Pressures in the scala tympani tended to be larger in magnitude than pressures in the scala vestibuli, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170 dB sound pressure level. Instances of pressure transients varied with electrode styles. Conclusion: Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high-level sounds and thus could cause damage to the basilar membrane and/or hair cells.

Brain Stimulation · Nov 2016

Closed-Loop Deep Brain Stimulation Effects on Parkinsonian Motor Symptoms in a Non-Human Primate – Is Beta Enough? (opens in a new tab)

Luke A. Johnson, Shane D. Nebeck, Abirami Muralidharan, … Jerrold L. Vitek

Abstract

Background: Incorporating feedback controls based on real-time measures of pathological brain activity may improve deep brain stimulation (DBS) approaches for the treatment of Parkinson's disease (PD). Excessive beta oscillations in subthalamic nucleus (STN) local field potentials (LFP) have been proposed as a potential biomarker for closed-loop DBS (CL-DBS). Objective: In a non-human primate PD model we compared CL-DBS, which delivered stimulation only when STN LFP beta activity was elevated, to traditional continuous DBS (tDBS). Methods: Therapeutic effects of CL-DBS and tDBS relative to the Off-DBS condition were evaluated via a clinical rating scale and objective measures of movement speed during a cued reaching task. Results: CL-DBS was comparable to tDBS at reducing rigidity, while reducing the amount of time DBS was on by ≈50%; however, only tDBS improved bradykinesia during the reaching behavior. This was likely due to reach-related reductions in beta amplitude that influence the timing and duration of stimulation in the CL-DBS condition. Conclusion: These results illustrate the potential utility of closed-loop DBS devices for PD based on STN beta LFP levels. They also point to possible consequences in behavioral tasks when restricting real-time sensing to a single LFP frequency that itself is modulated during performance of such tasks. The present study provides data that suggest alternate algorithms or more than one physiological biomarker may be required to optimize the performance of behavioral tasks and demonstrates the value of using multiple objective measures when evaluating the efficacy of closed-loop DBS systems.

Journal of Neurophysiology · Nov 2016

Robust modulation of arousal regulation, performance, and frontostriatal activity through central thalamic deep brain stimulation in healthy nonhuman primates (opens in a new tab)

Jonathan L. Baker, Jae-Wook Ryou, Xuefeng F. Wei, … Keith P. Purpura

Abstract

The central thalamus (CT) is a key component of the brain-wide network underlying arousal regulation and sensory-motor integration during wakefulness in the mammalian brain. Dysfunction of the CT, typically a result of severe brain injury (SBI), leads to long-lasting impairments in arousal regulation and subsequent deficits in cognition. Central thalamic deep brain stimulation (CT-DBS) is proposed as a therapy to reestablish and maintain arousal regulation to improve cognition in select SBI patients. However, a mechanistic understanding of CT-DBS and an optimal method of implementing this promising therapy are unknown. Here we demonstrate in two healthy nonhuman primates (NHPs), Macaca mulatta, that location-specific CT-DBS improves performance in visuomotor tasks and is associated with physiological effects consistent with enhancement of endogenous arousal. Specifically, CT-DBS within the lateral wing of the central lateral nucleus and the surrounding medial dorsal thalamic tegmental tract (DTTm) produces a rapid and robust modulation of performance and arousal, as measured by neuronal activity in the frontal cortex and striatum. Notably, the most robust and reliable behavioral and physiological responses resulted when we implemented a novel method of CT-DBS that orients and shapes the electric field within the DTTm using spatially separated DBS leads. Collectively, our results demonstrate that selective activation within the DTTm of the CT robustly regulates endogenous arousal and enhances cognitive performance in the intact NHP; these findings provide insights into the mechanism of CT-DBS and further support the development of CT-DBS as a therapy for reestablishing arousal regulation to support cognition in SBI patients.

The Journal of Spinal Cord Medicine · Oct 2016

An ovine model of spinal cord injury (opens in a new tab)

Saul Wilson, Kingsley O. Abode-Iyamah, John W. Miller, … Matthew A. Howard

Abstract

Objective: To develop a large animal model of spinal cord injury (SCI), for use in translational studies of spinal cord stimulation (SCS) in the treatment of spasticity. We seek to establish thresholds for the SCS parameters associated with reduction of post-SCI spasticity in the pelvic limbs, with implications for patients. Study design: The weight-drop method was used to create a moderate SCI in adult sheep, leading to mild spasticity in the pelvic limbs. Electrodes for electromyography (EMG) and an epidural spinal cord stimulator were then implanted. Behavioral and electrophysiological data were taken during treadmill ambulation in six animals, and in one animal with and without SCS at 0.1, 0.3, 0.5, and 0.9 V. Setting: All surgical procedures were carried out at the University of Iowa. The gait measurements were made at Iowa State University. Material and methods: Nine adult female sheep were used in these institutionally approved protocols. Six of them were trained in treadmill ambulation prior to SCI surgeries, and underwent gait analysis pre- and post-SCI. Stretch reflex and H-reflex measurements were also made in conscious animals. Results: Gait analysis revealed repeatable quantitative differences in 20% of the key kinematic parameters of the sheep, pre- and post-SCI. Hock joint angular velocity increased toward the normal pre-injury baseline in the animal with SCS at 0.9 V. Conclusion: The ovine model is workable as a large animal surrogate suitable for translational studies of novel SCS therapies aimed at relieving spasticity in patients with SCI.

Otology & Neurotology · Oct 2016

A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation (opens in a new tab)

Renee M. Banakis Hartl, Jameson K. Mattingly, Nathaniel T. Greene, … Daniel J. Tollin

Abstract

Hypothesis: A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Background: Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Methods: Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Results: Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Conclusion: Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity.

IEEE Transactions on Haptics · Oct 2016

Task-Specific Somatosensory Feedback via Cortical Stimulation in Humans (opens in a new tab)

Jeneva A. Cronin, Jing Wu, Kelly L. Collins, … Jared D. Olson

Abstract

Cortical stimulation through electrocorticographic (ECoG) electrodes is a potential method for providing sensory feedback in future prosthetic and rehabilitative applications. Here, we evaluate human subjects' ability to continuously modulate their motor behavior based on feedback from direct surface stimulation of the somatosensory cortex. Subjects wore a dataglove that measured their hand aperture position and received one of three stimuli over the hand sensory cortex based on their current hand position as compared to a target aperture position. Using cortical stimulation feedback, subjects adjusted their hand aperture to move towards the target aperture region. One subject was able to achieve accuracies and R2 values well above chance (best performance: R2 = 0.93; accuracy = 0.76/1). Performance dropped during the catch trial (same stimulus independent of the position) to below chance levels, suggesting that the subject had been using the varied sensory feedback to modulate their motor behavior. To our knowledge, this study represents one of the first demonstrations of using direct cortical surface stimulation of the human sensory cortex to perform a motor task, and is a first step towards developing closed-loop human sensorimotor brain-computer interfaces.

Scientific Reports · Sep 2016

Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing (opens in a new tab)

Yichen Lu, Hongming Lyu, Andrew G. Richardson, … Duygu Kuzum

Abstract

Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial.

Ear & Hearing · Sep 2016

The Effect of Microphone Placement on Interaural Level Differences and Sound Localization Across the Horizontal Plane in Bilateral Cochlear Implant Users (opens in a new tab)

Heath G. Jones, Alan Kan, Ruth Y. Litovsky

Abstract

Objective: This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Design: Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. Results: The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. Conclusions: The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.

2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Aug 2016

Somatosensory encoding with cuneate nucleus microstimulation: Detection of artificial stimuli (opens in a new tab)

Srihari Y. Sritharan, Andrew G. Richardson, Pauline K. Weigand, … Timothy H. Lucas

Abstract

The sense of touch and proprioception are critical to movement control. After spinal cord injury, these senses may be restored with direct, electrical microstimulation of the brain as part of a complete sensorimotor neuroprosthesis. The present study was designed to test, in part, the hypothesis that the cuneate nucleus (CN) of the brainstem is a suitable site to encode somatosensory information. Two rhesus macaques were implanted with microelectrode arrays providing chronic access to the CN. The monkeys were trained on an active touch oddity task to detect vibrotactile stimuli. When the vibrotactile stimuli were replaced with electrical stimuli delivered to the CN, initial detection probabilities were near chance. Detection performance improved over time, reaching a plateau after about 10 daily sessions. At plateau performance, the monkeys exhibited detection probabilities that were 68-80% higher than the chance probability. Finally, detection probability was quantified as a function of stimulus amplitude. The resulting psychometric curve showed a detection threshold of 45 μA for 100-Hz stimulus trains. These behavioral data are the first to show that artificial CN activation is sufficient for perception. The results are consistent with our hypothesis and motivate future tests of the CN as a somatosensory encoding site.

Journal of Neurophysiology · Aug 2016

A physiological and behavioral system for hearing restoration with cochlear implants (opens in a new tab)

Julia King, Ina Shehu, J. Thomas Roland, … Robert C. Froemke

Abstract

Cochlear implants are neuroprosthetic devices that provide hearing to deaf patients, although outcomes are highly variable even with prolonged training and use. The central auditory system must process cochlear implant signals, but it is unclear how neural circuits adapt—or fail to adapt—to such inputs. The knowledge of these mechanisms is required for development of next-generation neuroprosthetics that interface with existing neural circuits and enable synaptic plasticity to improve perceptual outcomes. Here, we describe a new system for cochlear implant insertion, stimulation, and behavioral training in rats. Animals were first ensured to have significant hearing loss via physiological and behavioral criteria. We developed a surgical approach for multichannel (2- or 8-channel) array insertion, comparable with implantation procedures and depth in humans. Peripheral and cortical responses to stimulation were used to program the implant objectively. Animals fitted with implants learned to use them for an auditory-dependent task that assesses frequency detection and recognition in a background of environmentally and self-generated noise and ceased responding appropriately to sounds when the implant was temporarily inactivated. This physiologically calibrated and behaviorally validated system provides a powerful opportunity to study the neural basis of neuroprosthetic device use and plasticity.

Cerebral Cortex · Jul 2016

Modulatory Effects of the Ipsi and Contralateral Ventral Premotor Cortex (PMv) on the Primary Motor Cortex (M1) Outputs to Intrinsic Hand and Forearm Muscles in Cebus apella (opens in a new tab)

Stephan Quessy, Sandrine L. Côté, Adjia Hamadjida, … Numa Dancause

Abstract

The ventral premotor cortex (PMv) is a key node in the neural network involved in grasping. One way PMv can carry out this function is by modulating the outputs of the primary motor cortex (M1) to intrinsic hand and forearm muscles. As many PMv neurons discharge when grasping with either arm, both PMv within the same hemisphere (ipsilateral; iPMv) and in the opposite hemisphere (contralateral; cPMv) could modulate M1 outputs. Our objective was to compare modulatory effects of iPMv and cPMv on M1 outputs to intrinsic hand and forearm muscles. We used paired-pulse protocols with intracortical microstimulations in capuchin monkeys. A conditioning stimulus was applied in either iPMv or cPMv simultaneously or prior to a test stimulus in M1 and the effects quantified in electromyographic signals. Modulatory effects from iPMv were predominantly facilitatory, and facilitation was much more common and powerful on intrinsic hand than forearm muscles. In contrast, while the conditioning of cPMv could elicit facilitatory effects, in particular to intrinsic hand muscles, it was much more likely to inhibit M1 outputs. These data show that iPMv and cPMv have very different modulatory effects on the outputs of M1 to intrinsic hand and forearm muscles.

Journal of Neuroscience Research · Jul 2016

Structural changes in the inner ear over time studied in the experimentally deafened guinea pig (opens in a new tab)

Anette Fransson, Mats Ulfendahl

Abstract

Today a cochlear implant (CI) may significantly restore auditory function, even for people with a profound hearing loss. Because the efficacy of a CI is believed to depend mainly on the remaining population of spiral ganglion neurons (SGNs), it is important to understand the timeline of the degenerative process of the auditory neurons following deafness. Guinea pigs were transtympanically deafened with neomycin, verified by recording auditory brainstem responses (ABRs), and then sacrificed at different time points. Loss of SGNs as well as changes in cell body and nuclear volume were estimated. To study the effect of delayed treatment, a group of animals that had been deaf for 12 weeks was implanted with a stimulus electrode mimicking a CI, after which they received a 4‐week treatment with glial cell‐derived neurotrophic factor (GDNF). The electrical responsiveness of the SGNs was measured by recording electrically evoked ABRs. There was a rapid degeneration during the first 7 weeks, shown as a significant reduction of the SGN population. The degenerative process then slowed, and there was no difference in the amount of remaining neurons between weeks 7 and 18. © 2016 The Authors Journal of Neuroscience Research Published by Wiley Periodicals, Inc.

Hearing Research · Jul 2016

Cochlear perfusion with a viscous fluid (opens in a new tab)

Yi Wang, Elizabeth S. Olson

Abstract

The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and then clearance of viscous fluid within the cochlea, or to a temporary position shift of the Organ of Corti. After 0.5% HA perfusion, a short latency positive peak (P0) appeared in the CAP waveform. This P0 might be due to a change in the cochlea's traveling-wave pattern, or distortion in the cochlear microphonic.

Journal of Neuroscience Methods · Jul 2016

Second spatial derivative analysis of cortical surface potentials recorded in cat primary auditory cortex using thin film surface arrays: Comparisons with multi-unit data (opens in a new tab)

James B. Fallon, Sam Irving, Satinderpall S. Pannu, … Dexter R.F. Irvine

Abstract

Background: Current source density analysis of recordings from penetrating electrode arrays has traditionally been used to examine the layer- specific cortical activation and plastic changes associated with changed afferent input. We report on a related analysis, the second spatial derivative (SSD) of surface local field potentials (LFPs) recorded using custom designed thin-film polyimide substrate arrays. Results: SSD analysis of tone- evoked LFPs generated from the auditory cortex under the recording array demonstrated a stereotypical single local minimum, often flanked by maxima on both the caudal and rostral sides. In contrast, tone-pips at frequencies not represented in the region under the array, but known (on the basis of normal tonotopic organization) to be represented caudal to the recording array, had a more complex pattern of many sources and sinks. Comparison with existing methods: Compared to traditional analysis of LFPs, SSD analysis produced a tonotopic map that was more similar to that obtained with multi-unit recordings in a normal-hearing animal. Additionally, the statistically significant decrease in the number of acoustically responsive cortical locations in partially deafened cats following 6 months of cochlear implant use compared to unstimulated cases observed with multi-unit data (p=0.04) was also observed with SSD analysis (p=0.02), but was not apparent using traditional analysis of LFPs (p=0.6). Conclusions: SSD analysis of surface LFPs from the thin-film array provides a rapid and robust method for examining the spatial distribution of cortical activity with improved spatial resolution compared to more traditional LFP recordings.