Menu

Subject Interface – Stim & Record

Used in 19 published studies →

Improve your stimulation paradigm with TDT’s versatile Subject Interface (SI). Customize up to 128 channels of stimulation or recording and mix and match isolated stimulation and neural signal recording in one versatile device. The SI programmable stimulator and amplifier features new electrical stimulation capabilities, delivering complex stimulus patterns with unprecedented precision and flexibility, and can carry multiple banks of high fidelity stimulation and recording in one versatile device.

Research Uses

Product Specs

Resources

Publications

  • Spike-triggered stimulation
  • Designed for human, non-human primate, and small mammal use
  • Multi-modal signal integration (including single unit, LFP, and ECoG)
  • Simultaneous animal recording
  • Deep brain stimulation

19 published studies used the Subject Interface. The newest:

Clinical and Experimental Otorhinolaryngology · Aug 2026

Effects of Neonatal Deafness on Central Tonotopic Organization in Rats: an Electrophysiological Study (opens in a new tab)

Woongsang Sunwoo, Yeeun Kim

Abstract

Objectives. Spatial mapping of sound frequencies along the auditory pathway is refined through sound-evoked activity during early development. However, how neonatal auditory deprivation alters this organization remains unclear. This study examined frequency-specific spatial representations in the inferior colliculus (IC) using targeted low-frequency (apical) and high-frequency (basal) cochlear stimulation, enabling direct evaluation of low-frequency pathway integrity after neonatal deafness.Methods. Sixteen Sprague-Dawley rats (8 normal-hearing [NH] and 8 neonatally deafened [ND]) were studied. Neonatal deafness was induced by daily kanamycin injections from postnatal days 4 to 17. At 8–10 weeks of age, all animals underwent unilateral cochlear implantation with bipolar electrode pairs positioned in apical and basal cochlear regions to activate low- and high-frequency pathways. Multiunit responses were recorded from the contralateral IC using a multichannel linear electrode array. Spatial tuning curves (STCs) based on cumulative discriminability were used to assess thresholds, spread of excitation, and tonotopic precision. Spiral ganglion neuron (SGN) density was quantified histologically.Results. Despite 48%–67% SGN loss across cochlear turns, electrically evoked auditory brainstem response thresholds and IC thresholds were comparable between groups, indicating preserved peripheral excitability. However, ND rats exhibited significantly broader STCs (P=0.002) and reduced dorsoventral separation of apical and basal best sites (1.18± 0.67 mm vs. 1.80±0.40 mm, P=0.039), reflecting degraded central tonotopic precision. The effects were most pronounced for apical (low-frequency) stimulation, consistent with the selective vulnerability of low-frequency pathways to early auditory deprivation.Conclusion. These findings provide direct physiological evidence that early auditory experience is critical for refining frequency-organized connectivity in the auditory midbrain. The preferential degradation of apical (low-frequency) spatial tuning offers translational insights for optimizing stimulation strategies in early-onset deafness.

Nature Communications · Jul 2026

Neural dynamics of temporal interference stimulation monitoring by soft liquid metal interfaces across neural systems (opens in a new tab)

Enji Kim, Wonjung Park, Yeon-Mi Hong, … Jang-Ung Park

Abstract

Neuromodulation is widely employed to enhance neural activity and restore impaired circuitry, yet current methods suffer from invasiveness, limited depth, or poor spatial resolution. Temporal interference stimulation (TIS) has emerged as a non-invasive approach to modulate deep brain regions via interference of high-frequency electric fields, achieving spatial selectivity. Despite its potential, the physiological effects remain unexplored. Here, we present a customized liquid metal-based neural interface to record electrophysiological responses to TIS across diverse neural tissues, from brain organoids to mouse brains. The softness of the interface minimizes invasiveness while ensuring stable access to deep neural regions. Electrophysiological analyses reveal TIS-induced dynamics in neurodevelopment and functional connectivity. Furthermore, we investigated latent neural dynamics, presenting population-level neural activity, to compare responses across models of differing complexity and maturity. By combining soft neural interfaces with multi-scale analyses, this study uncovers how neuromodulation shapes neural dynamics and supports the development of future therapeutic strategies.

Nature Electronics · Apr 2026

An implantable epiretinal device for near-infrared light perception (opens in a new tab)

Won Gi Chung, Inhea Jeong, Eun-Joo Lee, … Jang-Ung Park

Abstract

Human vision relies on photoreceptor cells in the outer retina that are sensitive to visible light. However, many people suffer from blindness due to retinal diseases that cause photoreceptor degeneration. Electrical stimulation of retinal neurons can recreate the action potentials associated with seeing that are generated by these cells. Here we report a thin artificial retina that can be adhered to the epiretinal surface and can convert near-infrared (NIR) light into electrical stimuli that selectively stimulate ganglion cells. The artificial retina consists of a NIR-sensitive phototransistor array and three-dimensional liquid metal micropillar electrodes. The liquid metal electrodes enhance proximity to retinal ganglion cells, providing effective charge injection while minimizing tissue damage, owing to their low Young’s modulus. Ex vivo studies demonstrate its biocompatibility, and in vivo studies using healthy and blind mice demonstrate perception of both visible and NIR light, as indicated by cortical recordings and behavioural tests. The retina could, in the future, be used to create a NIR visual channel in patients with photoreceptor degenerative blindness without interfering with their remaining natural vision.

Read all 19 papers →

How to cite the Subject Interface Stim & Record

Name the model in your Methods so readers can find the equipment you used, for example:

Subject Interface (Tucker-Davis Technologies, Alachua, FL, USA)

Request this product

Isolated Stimulation and Neural Signal Recording

  • Customize up to 8 banks with stimulation, analog and digital recording (up to 128 channels of stimulation or recording mix and match)
  • Stimulate up to 5 mA per channel with 10 nA resolution and +/-15V compliance
  • Deliver stimuli in current or voltage mode
  • Combine multiple banks to increase stimulation current and/or compliance voltage
  • Charge balance built into SI hardware and TDT’s Synapse Software
  • Generate complex pulse trains with integrated Synapse software