Nature Communications · Apr 2019
Leila Ghanbari, Russell E. Carter, Mathew L. Rynes, … Suhasa B. Kodandaramaiah
Abstract
Neural computations occurring simultaneously in multiple cerebral cortical regions are critical for mediating behaviors. Progress has been made in understanding how neural activity in specific cortical regions contributes to behavior. However, there is a lack of tools that allow simultaneous monitoring and perturbing neural activity from multiple cortical regions. We engineered ‘See-Shells’—digitally designed, morphologically realistic, transparent polymer skulls that allow long-term (>300 days) optical access to 45 mm 2 of the dorsal cerebral cortex in the mouse. We demonstrate the ability to perform mesoscopic imaging, as well as cellular and subcellular resolution two-photon imaging of neural structures up to 600 µm deep. See-Shells allow calcium imaging from multiple, non-contiguous regions across the cortex. Perforated See-Shells enable introducing penetrating neural probes to perturb or record neural activity simultaneously with whole cortex imaging. See-Shells are constructed using common desktop fabrication tools, providing a powerful tool for investigating brain structure and function.
The Journal of the Acoustical Society of America · Apr 2019
Keng Moua, Alan Kan, Heath G. Jones, … Ruth Y. Litovsky
Abstract
Adults with bilateral cochlear implants (BiCIs) receive benefits in localizing stationary sounds when listening with two implants compared with one; however, sound localization ability is significantly poorer when compared to normal hearing (NH) listeners. Little is known about localizing sound sources in motion, which occurs in typical everyday listening situations. The authors considered the possibility that sound motion may improve sound localization in BiCI users by providing multiple places of information. Alternatively, the ability to compare multiple spatial locations may be compromised in BiCI users due to degradation of binaural cues, and thus result in poorer performance relative to NH adults. In this study, the authors assessed listeners' abilities to distinguish between sounds that appear to be moving vs stationary, and track the angular range and direction of moving sounds. Stimuli were bandpass-filtered (150–6000 Hz) noise bursts of different durations, panned over an array of loudspeakers. Overall, the results showed that BiCI users were poorer than NH adults in (i) distinguishing between a moving vs stationary sound, (ii) correctly identifying the direction of movement, and (iii) tracking the range of movement. These findings suggest that conventional cochlear implant processors are not able to fully provide the cues necessary for perceiving auditory motion correctly.
Scientific Reports · Mar 2019
Chuming Zhao, Katherine E. Knisely, Deborah J. Colesa, … Karl Grosh
Abstract
The ability to measure the voltage readout from a sensor implanted inside the living cochlea enables continuous monitoring of intracochlear acoustic pressure locally, which could improve cochlear implants. We developed a piezoelectric intracochlear acoustic transducer (PIAT) designed to sense the acoustic pressure while fully implanted inside a living guinea pig cochlea. The PIAT, fabricated using micro-electro-mechanical systems (MEMS) techniques, consisted of an array of four piezoelectric cantilevers with varying lengths to enhance sensitivity across a wide frequency bandwidth. Prior to implantation, benchtop tests were conducted to characterize the device performance in air and in water. When implanted in the cochlea of an anesthetized guinea pig, the in vivo voltage response from the PIAT was measured in response to 80–95 dB sound pressure level 1–14 kHz sinusoidal acoustic excitation at the entrance of the guinea pig’s ear canal. All sensed signals were above the noise floor and unaffected by crosstalk from the cochlear microphonic or external electrical interference. These results demonstrate that external acoustic stimulus can be sensed via the piezoelectric voltage response of the implanted MEMS transducer inside the living cochlea, providing key steps towards developing intracochlear acoustic sensors to replace external or subcutaneous microphones for auditory prosthetics.
Scientific Reports · Mar 2019
David J. Caldwell, Jeneva A. Cronin, Jing Wu, … Jeffrey G. Ojemann
Abstract
Direct cortical stimulation (DCS) of primary somatosensory cortex (S1) could help restore sensation and provide task-relevant feedback in a neuroprosthesis. However, the psychophysics of S1 DCS is poorly studied, including any comparison to cutaneous haptic stimulation. We compare the response times to DCS of human hand somatosensory cortex through electrocorticographic grids with response times to haptic stimuli delivered to the hand in four subjects. We found that subjects respond significantly slower to S1 DCS than to natural, haptic stimuli for a range of DCS train durations. Median response times for haptic stimulation varied from 198 ms to 313 ms, while median responses to reliably perceived DCS ranged from 254 ms for one subject, all the way to 528 ms for another. We discern no significant impact of learning or habituation through the analysis of blocked trials, and find no significant impact of cortical stimulation train duration on response times. Our results provide a realistic set of expectations for latencies with somatosensory DCS feedback for future neuroprosthetic applications and motivate the study of neural mechanisms underlying human perception of somatosensation via DCS.
Otology & Neurotology · Mar 2019
Zhao Ellen Peng, Christi Hess, Jenny R. Saffran, … Ruth Y. Litovsky
Abstract
Hypothesis: Children of 2 to 3 years old with cochlear implants can perform consonant discriminations using fine-grained acoustic cues. Background: Children born with severe-to-profound deafness are provided with early cochlear implantation (<2 yr) to maximize oral communication outcomes. Little is known regarding their abilities to discriminate consonant contrasts for accurately identifying speech sounds. Methods: Using a Reaching for Sound paradigm to collect behavioral responses, consonant contrast discrimination was measured in 13 children with bilateral cochlear implants (BiCIs; aged 28–37 mo), and 13 age-matched normal-hearing (NH) children. Four contrast pairs were tested: 1) place + voicing, 2) place, 3) voicing, and 4) reduced voice-onset-time cue. Using standard processing strategies, electrodograms showing pulsatile stimulation patterns were created retrospectively to assess the spectral-temporal cues delivered through the clinical speech processors. Results: As a group, children with BiCIs were able to discriminate all consonant contrasts at a level that was above chance, but their performance was poorer than NH children. Larger individual variability in discrimination performance was found in children with BiCIs. Stepwise regression revealed that, in the place contrast, chronological age was correlated with improved discrimination performance among children with BiCIs. Conclusion: Children with BiCIs were able to discriminate consonant contrasts using fine-grained spectral-temporal cues above chance level but more poorly than their NH peers. Electrodogram analysis confirmed the access to spectral-temporal cues in the consonant contrasts through clinical speech processors. However, the cue saliency might not have be enough for children with BiCIs to achieve the same discrimination accuracy as NH children.
Hearing Research · Mar 2019
Stephanie J. Wong, Kristina S. Abrams, Kassidy N. Amburgey, … Kenneth S. Henry
Abstract
Auditory-nerve fibers are lost steadily with age and as a possible consequence of noise-induced glutamate excitotoxicity. Auditory-nerve loss in the absence of other cochlear pathologies is thought to be undetectable with a pure-tone audiogram while degrading real-world speech perception (hidden hearing loss). Perceptual deficits remain unclear, however, due in part to the limited behavioral capacity of existing rodent models to discriminate complex sounds. The budgerigar is an avian vocal learner with human-like behavioral sensitivity to many simple and complex sounds and the capacity to mimic speech. Previous studies in this species show that intracochlear kainic-acid infusion reduces wave 1 of the auditory brainstem response by 40-70%, consistent with substantial excitotoxic auditory-nerve damage. The present study used operant-conditioning procedures in trained budgerigars to quantify kainic-acid effects on tone detection across frequency (0.25-8 kHz; the audiogram) and as a function of duration (20-160 ms; temporal integration). Tone thresholds in control animals were lowest from 1 to 4 kHz and decreased with increasing duration as in previous studies of the budgerigar. Behavioral results in kainic-acid-exposed animals were as sensitive as in controls, suggesting preservation of the audiogram and temporal integration despite auditory-nerve loss associated with up to 70% wave 1 reduction. Distortion-product otoacoustic emissions were also preserved in kainic-acid exposed animals, consistent with normal hair-cell function. These results highlight considerable perceptual resistance of tone-detection performance with selective auditory-nerve loss. Future behavioral studies in budgerigars with auditory-nerve damage can use complex speech-like stimuli to help clarify aspects of auditory perception impacted by this common cochlear pathology.
Molecular Therapy · Mar 2019
Hidekane Yoshimura, Seiji B. Shibata, Paul T. Ranum, … Richard J.H. Smith
Abstract
Hearing loss is the most common human sensory deficit. Its correction has been the goal of several gene-therapy based studies exploring a variety of interventions. Although these studies report varying degrees of success, all treatments have targeted developing inner ears in neonatal mice, a time point in the structural maturation of the cochlea prior to 26 weeks gestational age in humans. It is unclear whether cochlear gene therapy can salvage hearing in the mature organ of Corti. Herein, we report the first study to test gene therapy in an adult murine model of human deafness. Using a single intracochlear injection of an artificial microRNA carried in an AAV vector, we show that RNAi-mediated gene silencing can slow progression of hearing loss, improve inner hair cell survival, and prevent stereocilia bundle degeneration in the mature Beethoven mouse, a model of human TMC1 deafness. The ability to study gene therapy in mature murine ears constitutes a significant step toward its translation to human subjects.
bioRxiv · Jan 2019
Andrew R. Bogaard, Guillaume Lajoie, Hayley Boyd, … Eberhard E. Fetz
Abstract
Transcranial direct current stimulation (tDCS) is a non-invasive neuromodulation technique that is widely used to stimulate the sensorimotor cortex, and yet the mechanism by which it influences the natural activity of cortical networks is still under debate. Here, we characterize the effects of anodal and cathodal tDCS on underlying neurons in active macaque sensorimotor cortex across a range of doses. We find changes in spike rates that are sensitive to both current intensity and polarity, behavioral state, and that are cell-type specific. At high currents, effects persist after the offset of stimulation, and the spatiotemporal activity associated with motor activity of the contralateral limb, measured by dynamics of neural ensembles, are altered. These data suggest that tDCS induces reproducible and noticeable changes in cortical neuron activity and support the theory that it affects brain activity through a combination of single neuron polarization and network interactions.
Human Gene Therapy · 2019
Omar Akil, Bas Blits, Lawrence R. Lustig, Patricia A. Leake
Abstract
Contemporary cochlear implants (CI) are generally very effective for remediation of severe to profound sensorineural hearing loss, but outcomes are still highly variable. Auditory nerve survival is likely one of the major factors underlying this variability. Neurotrophin therapy therefore has been proposed for CI recipients, with the goal of improving outcomes by promoting improved survival of cochlear spiral ganglion neurons (SGN) and/or residual hair cells. Previous studies have shown that glial-derived neurotrophic factor (GDNF), brain-derived neurotrophic factor, and neurotrophin-3 can rescue SGNs following insult. The current study was designed to determine whether adeno-associated virus vector serotype 5 (AAV-5) encoding either green fluorescent protein or GDNF can transduce cells in the mouse cochlea to express useful levels of neurotrophin and to approximate the optimum therapeutic dose(s) for transducing hair cells and SGN. The findings demonstrate that AAV-5 is a potentially useful gene therapy vector for the cochlea, resulting in extremely high levels of transgene expression in the cochlear inner hair cells and SGN. However, overexpression of human GDNF in newborn mice caused severe neurological symptoms and hearing loss, likely due to Purkinje cell loss and cochlear nucleus pathology. Thus, extremely high levels of transgene protein expression should be avoided, particularly for proteins that have neurological function in neonatal subjects.
Scholarship@Western (Western University) · 2019
Gugustea R
Biological and Pharmaceutical Bulletin · 2019
Norito Nishiyama, Taro Yamaguchi, Masanori Yoneyama, … Kiyokazu Ogita
Abstract
It is well-known that outer hair cell (OHC) loss occurs in the cochlea of animal models of permanent hearing loss induced by intense noise exposure. Our earlier studies demonstrated the production of hydroxynonenal and peroxynitrite, as well as the disruption of gap junction-mediated intercellular communication (GJIC), in the cochlear spiral ligament prior to noise-induced sudden hearing loss. The goal of the present study was to evaluate the mechanism underlying cochlear OHC loss after sudden hearing loss induced by intense noise exposure. In organ of Corti explant cultures from mice, no significant OHC loss was observed after in vitro exposure to 4-hydroxynonenal (a product of lipid peroxidation), H2O2, SIN-1 (peroxynitrite generator), and carbenoxolone (a gap junction inhibitor). Interestingly, in vivo intracochlear carbenoxolone injection through the posterior semicircular canal caused marked OHC and hearing loss, as well as the disruption of gap junction-mediated intercellular communication in the cochlear spiral ligament. However, no significant OHC loss was observed in vivo in animals treated with 4-hydroxynonenal and SIN-1. Taken together, our data suggest that disruption of GJIC in the cochlear lateral wall structures is an important cause of cochlear OHC loss in models of hearing loss, including those induced by noise.
Trends in Hearing · 2019
Sebastian A. Ausili, Bradford Backus, Martijn J. H. Agterberg, … Marc M. van Wanrooij
Abstract
Bilateral cochlear-implant (CI) users and single-sided deaf listeners with a CI are less effective at localizing sounds than normal-hearing (NH) listeners. This performance gap is due to the degradation of binaural and monaural sound localization cues, caused by a combination of device-related and patient-related issues. In this study, we targeted the device-related issues by measuring sound localization performance of 11 NH listeners, listening to free-field stimuli processed by a real-time CI vocoder. The use of a real-time vocoder is a new approach, which enables testing in a free-field environment. For the NH listening condition, all listeners accurately and precisely localized sounds according to a linear stimulus–response relationship with an optimal gain and a minimal bias both in the azimuth and in the elevation directions. In contrast, when listening with bilateral real-time vocoders, listeners tended to orient either to the left or to the right in azimuth and were unable to determine sound source elevation. When listening with an NH ear and a unilateral vocoder, localization was impoverished on the vocoder side but improved toward the NH side. Localization performance was also reflected by systematic variations in reaction times across listening conditions. We conclude that perturbation of interaural temporal cues, reduction of interaural level cues, and removal of spectral pinna cues by the vocoder impairs sound localization. Listeners seem to ignore cues that were made unreliable by the vocoder, leading to acute reweighting of available localization cues. We discuss how current CI processors prevent CI users from localizing sounds in everyday environments.
The Journal of the Acoustical Society of America · 2019
Jeffrey Tao Cheng, Nima Maftoon, Jérémie Guignard, … John Rosowski
Abstract
Characterization of Tympanic Membrane (TM) surface motions with forward and reverse stimulation is important to understanding how the TM transduces acoustical and mechanical energy in both directions. In this paper, stroboscopic opto-electronic holography is used to quantify motions of the entire TM surface induced by forward sound and reverse mechanical stimulation in human cadaveric ears from 0.25 to 18.4 kHz. The forward sound stimulus was coupled to an anatomically realistic artificial ear canal that allowed optical access to the entire TM surface, and the reverse mechanical stimulus was applied to the body of the incus by a piezo-electric stimulator. The results show clear differences in TM surface motions evoked by the two stimuli. In the forward case, TM motion is dominated by standing-wave-like modal motions that are consistent with a relatively uniform sound-pressure load over the entire TM surface. With reverse mechanical stimulation, the TM surface shows more traveling waves, consistent with a localized mechanical drive applied to the manubrium embedded in the TM. With both stimuli, the manubrium moves less than the rest of the TM, consistent with the TM acting like a compliant membrane rather than a stiff diaphragm, and also consistent with catenary behavior due to the TM's curved shape.
Hearing Research · 2019
Kirill V. Nourski, Mitchell Steinschneider, Ariane E. Rhone, … Matthew A. Howard
Abstract
Understanding cortical processing of spectrally degraded speech in normal-hearing subjects may provide insights into how sound information is processed by cochlear implant (CI) users. This study investigated electrocorticographic (ECoG) responses to noise-vocoded speech and related these responses to behavioral performance in a phonemic identification task. Subjects were neurosurgical patients undergoing chronic invasive monitoring for medically refractory epilepsy. Stimuli were utterances /aba/ and /ada/, spectrally degraded using a noise vocoder (1-4 bands). ECoG responses were obtained from Heschl's gyrus (HG) and superior temporal gyrus (STG), and were examined within the high gamma frequency range (70-150 Hz). All subjects performed at chance accuracy with speech degraded to 1 and 2 spectral bands, and at or near ceiling for clear speech. Inter-subject variability was observed in the 3- and 4-band conditions. High gamma responses in posteromedial HG (auditory core cortex) were similar for all vocoded conditions and clear speech. A progressive preference for clear speech emerged in anterolateral segments of HG, regardless of behavioral performance. On the lateral STG, responses to all vocoded stimuli were larger in subjects with better task performance. In contrast, both behavioral and neural responses to clear speech were comparable across subjects regardless of their ability to identify degraded stimuli. Findings highlight differences in representation of spectrally degraded speech across cortical areas and their relationship to perception. The results are in agreement with prior non-invasive results. The data provide insight into the neural mechanisms associated with variability in perception of degraded speech and potentially into sources of such variability in CI users.
Nature Biomedical Engineering · Dec 2018
Andy Zhou, Samantha R. Santacruz, Benjamin C. Johnson, … Rikky Muller
Abstract
Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and the distortion of recorded signals by large and persistent stimulation artefacts. Here, we describe an artefact-free wireless neuromodulation device that enables research applications requiring high-throughput data streaming, low-latency biosignal processing, and simultaneous sensing and stimulation. The device is a miniaturized neural interface capable of closed-loop recording and stimulation on 128 channels, with on-board processing to fully cancel stimulation artefacts. In addition, it can detect neural biomarkers and automatically adjust stimulation parameters in closed-loop mode. In a behaving non-human primate, the device enabled long-term recordings of local field potentials and the real-time cancellation of stimulation artefacts, as well as closed-loop stimulation to disrupt movement preparatory activity during a delayed-reach task. The neuromodulation device may help advance neuroscientific discovery and preclinical investigations of stimulation-based therapeutic interventions.
Journal of Neuroscience Research · Dec 2018
Nicholas J. Michelson, James R. Eles, Alberto L. Vazquez, … Takashi D. Y. Kozai
Abstract
Electrical stimulation of the brain has become a mainstay of fundamental neuroscience research and an increasingly prevalent clinical therapy. Despite decades of use in basic neuroscience research and the growing prevalence of neuromodulation therapies, gaps in knowledge regarding activation or inactivation of neural elements over time have limited its ability to adequately interpret evoked downstream responses or fine‐tune stimulation parameters to focus on desired responses. In this work, in vivo two‐photon microscopy was used to image neuronal calcium activity in layer 2/3 neurons of somatosensory cortex (S1) in male C57BL/6J‐Tg(Thy1‐GCaMP6s)GP4.3Dkim/J mice during 30 s of continuous electrical stimulation at varying frequencies. We show frequency–dependent differences in spatial and temporal somatic responses during continuous stimulation. Our results elucidate conflicting results from prior studies reporting either dense spherical activation of somas biased toward those near the electrode, or sparse activation of somas at a distance via axons near the electrode. These findings indicate that the neural element specific temporal response local to the stimulating electrode changes as a function of applied charge density and frequency. These temporal responses need to be considered to properly interpret downstream circuit responses or determining mechanisms of action in basic science experiments or clinical therapeutic applications.
Materials · Dec 2018
Maria Vomero, Elena Zucchini, Emanuela Delfino, … Thomas Stieglitz
Abstract
Glassy carbon (GC) has high potential to serve as a biomaterial in neural applications because it is biocompatible, electrochemically inert and can be incorporated in polyimide-based implantable devices. Miniaturization and applicability of GC is, however, thought to be partially limited by its electrical conductivity. For this study, ultra-conformable polyimide-based electrocorticography (ECoG) devices with different-diameter GC electrodes were fabricated and tested in vitro and in rat models. For achieving conformability to the rat brain, polyimide was patterned in a finger-like shape and its thickness was set to 8 µm. To investigate different electrode sizes, each ECoG device was assigned electrodes with diameters of 50, 100, 200 and 300 µm. They were electrochemically characterized and subjected to 10 million biphasic pulses—for achieving a steady-state—and to X-ray photoelectron spectroscopy, for examining their elemental composition. The electrodes were then implanted epidurally to evaluate the ability of each diameter to detect neural activity. Results show that their performance at low frequencies (up to 300 Hz) depends on the distance from the signal source rather than on the electrode diameter, while at high frequencies (above 200 Hz) small electrodes have higher background noises than large ones, unless they are coated with poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS).
BioMed Research International · Nov 2018
So Young Kim, Hwon Heo, Doo Hee Kim, … Seung-ha Oh
Abstract
Single-sided deafness (SSD) induces cortical neural plastic changes according to duration of deafness. However, it is still unclear how the auditory cortical changes accompany the subcortical neural changes. The present study aimed to find the neural plastic changes in the cortical and subcortical auditory system following adult-onset single-sided deafness (SSD) using Mn-enhanced magnetic resonance imaging (MEMRI). B57BL/6 mice (postnatal 8-week-old) were divided into three groups: the SSD-4-week group (postnatal 12-week-old, n = 11), the SSD-8-week group (postnatal 16-week-old, n = 11), and a normal-hearing control group (postnatal 8-week-old, n = 9). The left cochlea was ablated in the SSD groups. White Gaussian noise was delivered for 24 h before MEMRI acquisition. T 1 -weighted MRI data were analyzed from the cochlear nucleus (CN), superior olivary complex (SOC), lateral lemniscus (LL), inferior colliculus (IC), medial geniculate body (MG), and auditory cortex (AC). The differences in relative Mn 2+ -enhanced signal intensities (Mn 2+ SI) and laterality were analyzed between the groups. Four weeks after the SSD procedure, the ipsilateral side of the SSD showed significantly lower Mn 2+ SI in the CN than the control group. On the other hand, the contralateral side of the SSD demonstrated significantly lower Mn 2+ SI in the SOC, LL, and IC. These decreased Mn 2+ SI values were partially recovered at 8 weeks after the SSD procedure. The interaural Mn 2+ SI differences representing the interaural dominance were highest in CN and then became less prominently higher in the auditory neural system. The SSD-8-week group still showed interaural differences in the CN, LL, and IC. In contrast, the MG and AC did not show any significant intergroup or interaural differences in Mn 2+ SI. In conclusion, subcortical auditory neural activities were decreased after SSD, and the interaural differences were diluted in the higher auditory nervous system. These findings were attenuated with time. Subcortical auditory neural changes after SSD may contribute to the change in tinnitus severity and the outcomes of cochlear implantation in SSD patients.
Nature Neuroscience · Oct 2018
Emanuele Formento, Karen Minassian, Fabien Wagner, … Gregoire Courtine
Abstract
Epidural electrical stimulation (EES) of the spinal cord restores locomotion in animal models of spinal cord injury but is less effective in humans. Here we hypothesized that this interspecies discrepancy is due to interference between EES and proprioceptive information in humans. Computational simulations and preclinical and clinical experiments reveal that EES blocks a significant amount of proprioceptive input in humans, but not in rats. This transient deafferentation prevents modulation of reciprocal inhibitory networks involved in locomotion and reduces or abolishes the conscious perception of leg position. Consequently, continuous EES can only facilitate locomotion within a narrow range of stimulation parameters and is unable to provide meaningful locomotor improvements in humans without rehabilitation. Simulations showed that burst stimulation and spatiotemporal stimulation profiles mitigate the cancellation of proprioceptive information, enabling robust control over motor neuron activity. This demonstrates the importance of stimulation protocols that preserve proprioceptive information to facilitate walking with EES.
Micromachines · Oct 2018
Jian Xu, Hongsun Guo, Anh Tuan Nguyen, … Zhi Yang
Abstract
Electrical nerve recording and stimulation technologies are critically needed to monitor and modulate nerve activity to treat a variety of neurological diseases. However, current neuromodulation technologies presented in the literature or commercially available products cannot support simultaneous recording and stimulation on the same nerve. To solve this problem, a new bidirectional neuromodulation system-on-chip (SoC) is proposed in this paper, which includes a frequency-shaping neural recorder and a fully integrated neural stimulator with charge balancing capability. In addition, auxiliary circuits consisting of power management and data transmission circuits are designed to provide the necessary power supply for the SoC and the bidirectional data communication between the SoC and an external computer via a universal serial bus (USB) interface, respectively. To achieve sufficient low input noise for sensing nerve activity at a sub-10 μ V range, several noise reduction techniques are developed in the neural recorder. The designed SoC was fabricated in a 0.18 μ m high-voltage Bipolar CMOS DMOS (BCD) process technology that was described in a previous publication and it has been recently tested in animal experiments that demonstrate the proposed SoC is capable of achieving reliable and simultaneous electrical stimulation and recording on the same nerve.