Trans Neural Syst · 2013
Electrical Stimulation publications
Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.
467 papers
Frontiers in Neural Circuits · 2013
Tonotopic and localized pathways from primary auditory cortex to the central nucleus of the inferior colliculus (opens in a new tab)
Abstract
Descending projections from the cortex to subcortical structures are critical for auditory plasticity, including the ability for central neurons to adjust their frequency tuning to relevant and meaningful stimuli. We show that focal electrical stimulation of primary auditory cortex in guinea pigs produces excitatory responses in the central nucleus of the inferior colliculus (CNIC) with two tonotopic patterns: a narrow tuned pattern that is consistent with previous findings showing direct frequency-aligned projections; and a broad tuned pattern in which the auditory cortex can influence multiple frequency regions. Moreover, excitatory responses could be elicited in the caudomedial portion along the isofrequency laminae of the CNIC but not in the rostrolateral portion. This descending organization may underlie or contribute to the ability of the auditory cortex to induce changes in frequency tuning of subcortical neurons as shown extensively in previous studies.
Frontiers in Neuroengineering · 2013
A hardware model of the auditory periphery to transduce acoustic signals into neural activity (opens in a new tab)
Abstract
To improve the performance of cochlear implants, we have integrated a microdevice into a model of the auditory periphery with the goal of creating a microprocessor. We constructed an artificial peripheral auditory system using a hybrid model in which polyvinylidene difluoride was used as a piezoelectric sensor to convert mechanical stimuli into electric signals. To produce frequency selectivity, the slit on a stainless steel base plate was designed such that the local resonance frequency of the membrane over the slit reflected the transfer function. In the acoustic sensor, electric signals were generated based on the piezoelectric effect from local stress in the membrane. The electrodes on the resonating plate produced relatively large electric output signals. The signals were fed into a computer model that mimicked some functions of inner hair cells, inner hair cell-auditory nerve synapses, and auditory nerve fibers. In general, the responses of the model to pure-tone burst and complex stimuli accurately represented the discharge rates of high-spontaneous-rate auditory nerve fibers across a range of frequencies greater than 1 kHz and middle to high sound pressure levels. Thus, the model provides a tool to understand information processing in the peripheral auditory system and a basic design for connecting artificial acoustic sensors to the peripheral auditory nervous system. Finally, we discuss the need for stimulus control with an appropriate model of the auditory periphery based on auditory brainstem responses that were electrically evoked by different temporal pulse patterns with the same pulse number.
Journal of Neural Engineering · Nov 2012
Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque (opens in a new tab)
Abstract
Objective: It has been hypothesized that a vision prosthesis capable of evoking useful visual percepts can be based upon electrically stimulating the primary visual cortex (V1) of a blind human subject via penetrating microelectrode arrays. As a continuation of earlier work, we examined several spatial and temporal characteristics of V1 microstimulation. Approach: An array of 100 penetrating microelectrodes was chronically implanted in V1 of a behaving macaque monkey. Microstimulation thresholds were measured using a two-alternative forced choice detection task. Relative locations of electrically-evoked percepts were measured using a memory saccade-to-target task. Main results: The principal finding was that two years after implantation we were able to evoke behavioural responses to electric stimulation across the spatial extent of the array using groups of contiguous electrodes. Consistent responses to stimulation were evoked at an average threshold current per electrode of 204 ± 49 µA (mean ± std) for groups of four electrodes and 91 ± 25 µA for groups of nine electrodes. Saccades to electrically-evoked percepts using groups of nine electrodes showed that the animal could discriminate spatially distinct percepts with groups having an average separation of 1.6 ± 0.3 mm (mean ± std) in cortex and 1.0° ± 0.2° in visual space. Significance. These results demonstrate chronic perceptual functionality and provide evidence for the feasibility of a cortically-based vision prosthesis for the blind using penetrating microelectrodes.
Physiological Measurement · Nov 2012
A new device concept for directly modulating spinal cord pathways: initial in vivo experimental results (opens in a new tab)
Abstract
We describe a novel spinal cord (SC) stimulator that is designed to overcome a major shortcoming of existing stimulator devices: their restricted capacity to selectively activate targeted axons within the dorsal columns. This device overcomes that limitation by delivering electrical stimuli directly to the pial surface of the SC. Our goal in testing this device was to measure its ability to physiologically activate the SC and examine its capacity to modulate somatosensory evoked potentials (SSEPs) triggered by peripheral stimulation. In this acute study on adult sheep (n = 7), local field potentials were recorded from a grid placed in the subdural space of the right hemisphere during electrical stimulation of the left tibial nerve and the spinal cord. Large amplitude SSEPs (>200 µV) in response to SC stimulation were consistently obtained at stimulation strengths well below the thresholds inducing neural injury. Moreover, stimulation of the dorsal columns with signals employed routinely by devices in standard clinical use, e.g., 50 Hz, 0.2 ms pulse width, produced long-lasting changes (>4.5 h) in the SSEP patterns produced by subsequent tibial nerve stimulation. The results of these acute experiments demonstrate that this device can be safely secured to the SC surface and effectively activate somatosensory pathways.
The Journal of Neuroscience · Oct 2012
Differences in sensitivity to neural timing among cortical areas (opens in a new tab)
Abstract
The basic circuitry of auditory, visual, somatosensory and other cortical areas is highly stereotyped (Douglas and Martin, 2004). However, it remains unclear whether this anatomical stereotypy implies functional homogeneity, or whether instead different cortical areas are specialized to process the diverse sensory inputs they receive. Here we have used a two alternative forced choice task to assess modality-specific differences in the ability of rats to exploit precise neuronal timing. We delivered pairs of electrical pulses directly to different areas of cortex to determine the minimum timing differences subjects could detect. By stimulating the cortex directly, we isolated differences due to cortical circuitry rather than to sensory transduction and subcortical processing. Surprisingly, the minimum detectable timing differences varied over more than an order of magnitude, ranging from 1 ms in barrel cortex to 15 ms in visual cortex. Furthermore, these modality-specific differences depended upon sensory experience: although animals subjected to whisker clipping initially showed an impaired ability to exploit fine timing in barrel cortical stimulation, behavioral training partially rescued this deficit. Our results suggest that different cortical areas are adapted to the specific structure of the input signals they process, and that precise spike timing may play a more important role for some cortical areas than for others.
Journal of Microelectromechanical Systems · Oct 2012
Electrothermal Microactuators With Peg Drive Improve Performance for Brain Implant Applications (opens in a new tab)
Abstract
This paper presents a new actuation scheme for in-plane bidirectional translation of polysilicon microelectrodes. The new Chevron-peg actuation scheme uses microelectromechanical systems (MEMS) based electrothermal microactuators to move microelectrodes for brain implant applications. The design changes were motivated by specific needs identified by the in vivo testing of an earlier generation of MEMS microelectrodes that were actuated by the Chevron-latch type of mechanism. The microelectrodes actuated by the Chevron-peg mechanism discussed here show improved performance in the following key areas: higher force generation capability (111 μN per heat strip compared to 50 μN), reduced power consumption (91 mW compared to 360 mW), and reliable performance with consistent forward and backward movements of microelectrodes. Failure analysis of the Chevron-latch and the Chevron-peg type of actuation schemes showed that the latter is more robust to wear over four million cycles of operation. The parameters for the activation waveforms for Chevron-peg actuators were optimized using statistical analysis. Waveforms with a 1-ms time period and a 1-Hz frequency of operation showed minimal error between the expected and the actual movement of the microelectrodes. The new generation of Chevron-peg actuators and microelectrodes are therefore expected to enhance the longevity and performance of implanted microelectrodes in the brain. [2011-0341].
2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · Aug 2012
The depth, waveform and pulse rate for electrical microstimulation of the auditory cortex (opens in a new tab)
Abstract
Intracortical microstimulation of primary sensory regions of the brain offers a compelling platform for the development of sensory prostheses. However, fundamental questions remain regarding the optimal stimulation parameters. The purpose of this paper is to summarize a series of experiments which were designed to answer the following three questions. 1) What is the best electrode implantation depth? 2) What is the optimal stimulation waveform? 3) What is the maximal useful stimulus pulse rate? The present results suggest the following answers: 1) cortical layers V&IV, 2) biphasic, charge balanced, symmetric, cathode leading pulses with of duration of ∼ 100 microseconds per phase, and 3) 80 pulses-per-second.
Journal of Neurophysiology · Aug 2012
Modulation of thalamic auditory neurons by the primary auditory cortex (opens in a new tab)
Abstract
The central auditory system consists of the lemniscal and nonlemniscal pathways or systems, which are anatomically and physiologically different from each other. In the thalamus, the ventral division of the medial geniculate body (MGBv) belongs to the lemniscal system, whereas its medial (MGBm) and dorsal (MGBd) divisions belong to the nonlemniscal system. Lemniscal neurons are sharply frequency-tuned and provide highly frequency-specific information to the primary auditory cortex (AI), whereas nonlemniscal neurons are generally broadly frequency-tuned and project widely to cortical auditory areas including AI. These two systems are presumably different not only in auditory signal processing, but also in eliciting cortical plastic changes. Electric stimulation of narrowly frequency-tuned MGBv neurons evokes the shift of the frequency-tuning curves of AI neurons toward the tuning curves of the stimulated MGBv neurons (tone-specific plasticity). In contrast, electric stimulation of broadly frequency-tuned MGBm neurons augments the auditory responses of AI neurons and broadens their frequency-tuning curves (nonspecific plasticity). In our current studies, we found that electric stimulation of AI evoked tone-specific plastic changes of the MGBv neurons, whereas it degraded the frequency tuning of MGBm neurons by inhibiting their auditory responses. AI apparently modulates the lemniscal and nonlemniscal thalamic neurons in quite different ways. High MGBm activity presumably makes AI neurons less favorable for fine auditory signal processing, whereas high MGBv activity makes AI neurons more suitable for fine processing of specific auditory signals and reduces MGBm activity.
PLOS Computational Biology · Jul 2012
Shaping the dynamics of a bidirectional neural interface (opens in a new tab)
Abstract
Progress in decoding neural signals has enabled the development of interfaces that translate cortical brain activities into commands for operating robotic arms and other devices. The electrical stimulation of sensory areas provides a means to create artificial sensory information about the state of a device. Taken together, neural activity recording and microstimulation techniques allow us to embed a portion of the central nervous system within a closed-loop system, whose behavior emerges from the combined dynamical properties of its neural and artificial components. In this study we asked if it is possible to concurrently regulate this bidirectional brain-machine interaction so as to shape a desired dynamical behavior of the combined system. To this end, we followed a well-known biological pathway. In vertebrates, the communications between brain and limb mechanics are mediated by the spinal cord, which combines brain instructions with sensory information and organizes coordinated patterns of muscle forces driving the limbs along dynamically stable trajectories. We report the creation and testing of the first neural interface that emulates this sensory-motor interaction. The interface organizes a bidirectional communication between sensory and motor areas of the brain of anaesthetized rats and an external dynamical object with programmable properties. The system includes (a) a motor interface decoding signals from a motor cortical area, and (b) a sensory interface encoding the state of the external object into electrical stimuli to a somatosensory area. The interactions between brain activities and the state of the external object generate a family of trajectories converging upon a selected equilibrium point from arbitrary starting locations. Thus, the bidirectional interface establishes the possibility to specify not only a particular movement trajectory but an entire family of motions, which includes the prescribed reactions to unexpected perturbations.
Journal of the Association for Research in Otolaryngology · Jun 2012
Monopolar intracochlear pulse trains selectively activate the inferior colliculus (opens in a new tab)
Abstract
Previous cochlear implant studies using isolated electrical stimulus pulses in animal models have reported that intracochlear monopolar stimulus configurations elicit broad extents of neuronal activation within the central auditory system-much broader than the activation patterns produced by bipolar electrode pairs or acoustic tones. However, psychophysical and speech reception studies that use sustained pulse trains do not show clear performance differences for monopolar versus bipolar configurations. To test whether monopolar intracochlear stimulation can produce selective activation of the inferior colliculus, we measured activation widths along the tonotopic axis of the inferior colliculus for acoustic tones and 1,000-pulse/s electrical pulse trains in guinea pigs and cats. Electrical pulse trains were presented using an array of 6-12 stimulating electrodes distributed longitudinally on a space-filling silicone carrier positioned in the scala tympani of the cochlea. We found that for monopolar, bipolar, and acoustic stimuli, activation widths were significantly narrower for sustained responses than for the transient response to the stimulus onset. Furthermore, monopolar and bipolar stimuli elicited similar activation widths when compared at stimulus levels that produced similar peak spike rates. Surprisingly, we found that in guinea pigs, monopolar and bipolar stimuli produced narrower sustained activation than 60 dB sound pressure level acoustic tones when compared at stimulus levels that produced similar peak spike rates. Therefore, we conclude that intracochlear electrical stimulation using monopolar pulse trains can produce activation patterns that are at least as selective as bipolar or acoustic stimulation.
Hearing Research · Apr 2012
Midbrain responses to micro-stimulation of the cochlea using high density thin-film arrays (opens in a new tab)
Abstract
A broader activation of auditory nerve fibres than normal using a cochlear implant contributes to poor frequency discrimination. As cochlear implants also deliver a restricted dynamic range, this hinders the ability to segregate sound sources. Better frequency coding and control over amplitude may be achieved by limiting current spread during electrical stimulation of the cochlea and positioning electrodes closer to the modiolus. Thin-film high density microelectrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of urethane-anaesthetized rats and responses compared. Neurophysiological recordings were taken at 197 multi-unit clusters in the central nucleus of the inferior colliculus (CIC), a site that receives direct monaural innervation from the cochlear nucleus. CIC responses to both the platinum ring and high density electrodes were recorded and differences in activity to changes in stimulation intensity, thresholds and frequency coding of neural activation were examined. The high density electrode array elicited less CIC activity at nonspecific frequency regions than the platinum ring electrode array. The high density electrode array produced significantly lower thresholds and larger dynamic ranges than the platinum ring electrode array when positioned close to the modiolus. These results suggest that a higher density of stimulation sites on electrodes that effectively 'aim' current, combined with placement closer to the modiolus would permit finer control over charge delivery. This may equate to improved frequency specific perception and control over amplitude when using future cochlear implant devices.
IEEE Transactions on Neural Systems and Rehabilitation Engineering · Apr 2012
Evaluation of a MEMS-based dual metal-layer thin-film microelectrode array for suprachoroidal electrical stimulation (opens in a new tab)
Abstract
A double metal-layer thin-film platinum microelectrode array was fabricated for implantation between sclera and choroid based on MEMS processing techniques and photosensitive polyimide material. The array was composed of 60 stimulating sites (6 × 10) and four selectable returning electrodes. The diameter of each stimulating electrode was 350 μ m with a center-to-center spacing of 750 μm. The transient voltage responses of the electrode to current pulse stimulation indicated a charge-injection capacity greater than 52.1 μ C/cm (2) . Acute in vivo animal experiments showed that the implicit time of electrically evoked potentials (EEPs) was 17.09±1.45 ms at a threshold current of 25.55 ±5.43 μA for a full-row of simultaneously stimulated electrodes (i.e., current applied simultaneously to each of the 10 electrodes). Individual electrode stimulation threshold was 48.57 ±6.90 μA. The corresponding threshold charge densities were 13.28 ±2.82 μC/cm (2) and 25.24 ±3.59 μC/cm (2) , respectively. The spatial spread of the maximally recorded P1 response in the EEPs indicated a correspondence between the retinal stimulation site and the focal response location in the cortex. This method of array fabrication is suitable for acute suprachoroidal stimulation, and has a potential use for the fabrication of a visual prosthesis.
Journal of Neural Engineering · Apr 2012
Using independent component analysis to remove artifacts in visual cortex responses elicited by electrical stimulation of the optic nerve (opens in a new tab)
Abstract
In visual prosthesis research, electrically evoked potentials (EEPs) can be elicited by one or more biphasic current pulses delivered to the optic nerve (ON) through penetrating electrodes. Multi-channel EEPs recorded from the visual cortex usually contain large stimulus artifacts caused by instantaneous electrotonic current spread through the brain tissue. These stimulus artifacts contaminate the EEP waveform and often make subsequent analysis of the underlying neural responses difficult. This is particularly serious when investigating EEPs in response to electrical stimulation with long duration and multi-pulses. We applied independent component analysis (ICA) to remove these electrical stimulation-induced artifacts during the development of a visual prosthesis. Multi-channel signals were recorded from visual cortices of five rabbits in response to ON electrical stimulation with various stimulus parameters. ON action potentials were then blocked by lidocaine in order to acquire cortical potentials only including stimulus artifacts. Correlation analysis of reconstructed artifacts by ICA and artifacts recorded after blocking the ON indicates successful removal of artifacts from electrical stimulation by the ICA method. This technique has potential applications in studies designed to optimize the electrical stimulation parameters used by visual prostheses.
Journal of Neural Engineering · Mar 2012
Coordinated, multi-joint, fatigue-resistant feline stance produced with intrafascicular hind limb nerve stimulation (opens in a new tab)
Abstract
The production of graceful skeletal movements requires coordinated activation of multiple muscles that produce torques around multiple joints. The work described herein is focused on one such movement, stance, that requires coordinated activation of extensor muscles acting around the hip, knee and ankle joints. The forces evoked in these muscles by external stimulation all have a complex dependence on muscle length and shortening velocities, and some of these muscles are biarticular. In order to recreate sit-to-stand maneuvers in the anesthetized feline, we excited the hind limb musculature using intrafascicular multielectrode stimulation (IFMS) of the muscular branch of the sciatic nerve, the femoral nerve and the main branch of the sciatic nerve. Stimulation was achieved with either acutely or chronically implanted Utah Slanted Electrode Arrays (USEAs) via subsets of electrodes (1) that activated motor units in the extensor muscles of the hip, knee and ankle joints, (2) that were able to evoke large extension forces and (3) that manifested minimal coactivation of the targeted motor units. Three hind limb force-generation strategies were investigated, including sequential activation of independent motor units to increase force, and interleaved or simultaneous IFMS of three sets of six or more USEA electrodes that excited the hip, knee and ankle extensors. All force-generation strategies evoked stance, but the interleaved IFMS strategy also reduced muscle fatigue produced by repeated sit-to-stand maneuvers compared with fatigue produced by simultaneous activation of different motor neuron pools. These results demonstrate the use of interleaved IFMS as a means to recreate coordinated, fatigue-resistant multi-joint muscle forces in the unilateral hind limb. This muscle activation paradigm could provide a promising neuroprosthetic approach for the restoration of sit-to-stand transitions in individuals who are paralyzed by spinal cord injury, stroke or disease.
Critical Care Medicine · Feb 2012
Potential long-term benefits of acute hypothermia after spinal cord injury: assessments with somatosensory-evoked potentials (opens in a new tab)
Abstract
Objective: Neuroprotection by hypothermia has been an important research topic over last two decades. In animal models of spinal cord injury, the primary focus has been assessing the effects of hypothermia on behavioral and histologic outcomes. Although a few studies have investigated electrophysiological changes in descending motor pathways with motor-evoked potentials recorded during cooling, we report here hypothermia induced increased electrical conduction in the ascending spinal cord pathways with somatosensory-evoked potentials in injured rats. In our experiments, these effects lasted long after the acute hypothermia and were accompanied by potential long-term improvements in motor movement. Design: Laboratory investigation. Setting: University medical school. Subjects: Twenty-one female Lewis rats. Interventions: Hypothermia. Measurements and main results: All animals underwent spinal cord contusion with the NYU-Impactor by a 12.5-mm weight drop at thoracic vertebra T8. A group (n = 10) was randomly assigned for a systemic 2-hr hypothermia episode (32 ± 0.5°C) initiated approximately 2.0 hrs postinjury. Eleven rats were controls with postinjury temperature maintained at 37 ± 0.5°C for 2 hrs. The two groups underwent preinjury, weekly postinjury (up to 4 wks) somatosensory-evoked potential recordings and standard motor behavioral tests (BBB). Three randomly selected rats from each group were euthanized for histologic analysis at postinjury day 3 and day 28. Compared with controls, the hypothermia group showed significantly higher postinjury somatosensory-evoked potential amplitudes with longer latencies. The BBB scores were also higher immediately after injury and 4 wks later in the hypothermia group. Importantly, specific changes in the Basso, Beattie, Bresnahan scores in the hypothermia group (not seen in controls) indicated regained functions critical for motor control. Histologic evaluations showed more tissue preservation in the hypothermia group. Conclusions: After spinal cord injury, early systemic hypothermia provided significant neuroprotection weeks after injury through improved sensory electrophysiological signals in rats. This was accompanied by higher motor behavioral scores and more spared tissue in acute and postacute periods after injury.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012
The use of a novel carbon nanotube coated microelectrode array for chronic intracortical recording and microstimulation (opens in a new tab)
Abstract
Micro-electrode arrays (MEAs) have been used in a variety of intracortical neural prostheses. While intracortical MEAs have demonstrated their utility in neural prostheses, in many cases MEA performance declines after several months to years of in vivo implantation. The application of carbon nanotubes (CNTs) may increase the functional longevity of intracortical MEAs through enhanced biocompatibility and charge injection properties. An MEA metalized with platinum (Pt) on all electrodes had a CNT coating applied to the electrodes on half of the array. This Pt/Pt-CNT MEA was implanted into feline motor cortex for >1 year. Recordings of action potentials and 1 kHz impedance measurements were made on all electrodes to evaluate device functionality. Additionally, electromyogram (EMG) responses were evoked using micro-stimulation via the MEA to measure device performance. These metrics were compared between Pt and Pt-CNT electrodes. There was no significant difference in the data acquisition or micro-stimulation performance of Pt and the Pt-CNT electrodes. However, impedances were lower on the Pt-CNT electrodes. These results demonstrate the functionality of CNT coatings during chronic in vivo implantation. The lower impedances suggest that for microstimulation applications CNT coatings may impart enhanced interface properties.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012
A parametric study of intracortical microstimulation in behaving rats for the development of artificial sensory channels (opens in a new tab)
Abstract
In the framework of developing new brain-machine interfaces, many valuable results have been obtained in understanding which features of neural activity can be used in controlling an external device. Somatosensory real-time feedback is crucial for motor planning and for executing "online" errors correction during the movement. In people with sensory motor disabilities cortical microstimulation can be used as sensory feedback to elicit an artificial sensation providing the brain with information about the external environment. Even if intracortical microstimulation (ICMS) is broadly used in several experiments, understanding the psychophysics of such artificial sensory channel is still an open issue. Here we present the results of a parametric study that aims to define which stimulation parameters are needed to create an artificial sensation. Behaving rats were trained to report by pressing a lever the presence of ICMS delivered through microwire electrodes chronically implanted in the barrel cortex. Psychometric curves obtained by varying pulse amplitude, pulse frequency and train duration, demonstrate that in freely moving animals the perception threshold of microstimulation increased with respect to previous studies with head-restrained rats.
Scholarship@Western (Western University) · 2012
Effect of Head Movement on Sound Localization in Real and Simulated Cochlear Implant Users (opens in a new tab)
Frontiers in Neurology · 2012
The modified ampullar approach for vestibular implant surgery: feasibility and its first application in a human with a long-term vestibular loss (opens in a new tab)
Abstract
Objective: To assess, for the first time in a human with a long-term vestibular loss, a modified approach to the ampullae and the feasibility of evoking a VOR by ampullar stimulation. Materials and methods: Peroperative stimulation of the ampullae, using the ampullar approach, was performed under full anesthesia during cochlear implantation in a 21-year-old female patient, who had experienced bilateral vestibular areflexia and sensorineural hearing loss for almost 20 years. Results: The modified ampullar approach was performed successfully with as minimally invasive surgery as possible. Ampullar stimulation evoked eye movements containing vectors congruent with the stimulated canal. As expected, the preliminary electrophysiological data were influenced by the general anesthesia, which resulted in current spread and reduced maximum amplitudes of eye movement. Nevertheless, they confirm the feasibility of ampullar stimulation. Conclusion: The modified ampullar approach provides safe access to the ampullae using as minimally invasive surgery as possible. For the first time in a human with long-term bilateral vestibular areflexia, it is shown that the VOR can be evoked by ampullar stimulation, even when there has been no vestibular function for almost 20 years. This approach should be considered in vestibular surgery, as it provides safe access to one of the most favorable stimulus locations for development of a vestibular implant.
