Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

467 papers

Journal of the Association for Research in Otolaryngology · Jan 2014

Auditory-nerve responses to varied inter-phase gap and phase duration of the electric pulse stimulus as predictors for neuronal degeneration (opens in a new tab)

Dyan Ramekers, Huib Versnel, Stefan B. Strahl, … Wilko Grolman

Abstract

After severe hair cell loss, secondary degeneration of spiral ganglion cells (SGCs) is observed-a gradual process that spans years in humans but only takes weeks in guinea pigs. Being the target for cochlear implants (CIs), the physiological state of the SGCs is important for the effectiveness of a CI. For assessment of the nerve's state, focus has generally been on its response threshold. Our goal was to add a more detailed characterization of SGC functionality. To this end, the electrically evoked compound action potential (eCAP) was recorded in normal-hearing guinea pigs and guinea pigs that were deafened 2 or 6 weeks prior to the experiments. We evaluated changes in eCAP characteristics when the phase duration (PD) and inter-phase gap (IPG) of a biphasic current pulse were varied. We correlated the magnitude of these changes to quantified histological measures of neurodegeneration (SGC packing density and SGC size). The maximum eCAP amplitude, derived from the input-output function, decreased after deafening, and increased with both PD and IPG. The eCAP threshold did not change after deafening, and decreased with increasing PD and IPG. The dynamic range was wider for the 6-weeks-deaf animals than for the other two groups. Excitability increased with IPG (steeper slope of the input-output function and lower stimulation level at the half-maximum eCAP amplitude), but to a lesser extent for the deafened animals than for normal-hearing controls. The latency was shorter for the 6-weeks-deaf animals than for the other two groups. For several of these eCAP characteristics, the effect size of IPG correlated well with histological measures of degeneration, whereas effect size of PD did not. These correlations depend on the use of high current levels, which could limit clinical application. Nevertheless, their potential of these correlations towards assessment of the condition of the auditory nerve may be of great benefit to clinical diagnostics and prognosis in cochlear implant recipients.

Neurourology and Urodynamics · Jan 2014

Microstimulation of afferents in the sacral dorsal root ganglia can evoke reflex bladder activity (opens in a new tab)

Tim M. Bruns, Douglas J. Weber, Robert A. Gaunt

Abstract

Aims: Pudendal afferent fibers can be excited using electrical stimulation to evoke reflex bladder activity. While this approach shows promise for restoring bladder function, stimulation of desired pathways, and integration of afferent signals for sensory feedback remains challenging. At sacral dorsal root ganglia (DRG), the convergence of pelvic and pudendal afferent fibers provides a unique location for access to lower urinary tract neurons. Our goal in this study was to demonstrate the potential of microstimulation in sacral DRG for evoking reflex bladder responses. Methods: Penetrating microelectrode arrays were inserted in the left S1 and S2 DRG of six anesthetized adult male cats. While the bladder volume was held at a level below the leak volume, single and multiple channel stimulation was performed using various stimulation patterns. Results: Reflex bladder excitation was observed in five cats, for stimulation in either S1 or S2 DRG at 1 Hz and 30-33 Hz with a pulse amplitude of 10-50 µA. Bladder relaxation was observed during a few trials. Adjacent electrodes frequently elicited very different responses. Conclusions: These results demonstrate the potential of low-current microstimulation to recruit reflexive bladder responses. An approach such as this could be integrated with DRG recordings of bladder afferents to provide a closed-loop bladder neuroprosthesis.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2014

In vivo evaluation of a μECoG array for chronic stimulation (opens in a new tab)

Lycke RJ, Schendel A, Williams JC, Otto KJ

Abstract

Advancements in neural interfaces capable of neural stimulation have shown that neural implants may potentially target the central nervous system to treat neurological disorders. Unfortunately, many of the current technologies used to stimulate and record from the brain do not suffice for this purpose; those that provide a sufficient channel density, which is required for interfacing and chronic functionality in vivo, fail quickly, while others that last for an extended period of time in vivo are limited in recording and stimulation capabilities. Of the current methodologies available, electrocorticography (ECoG) based implants show promise for providing both high channel density interfaces as well as chronic functionality after implantation. This study evaluates the performance of a μECoG for the purpose of chronic stimulation.

PLOS ONE · Dec 2013

Investigation of a new electrode array technology for a central auditory prosthesis (opens in a new tab)

Roger Calixto, Behrouz Salamat, Thilo Rode, … Hubert H. Lim

Abstract

Ongoing clinical studies on patients recently implanted with the auditory midbrain implant (AMI) into the inferior colliculus (IC) for hearing restoration have shown that these patients do not achieve performance levels comparable to cochlear implant patients. The AMI consists of a single-shank array (20 electrodes) for stimulation along the tonotopic axis of the IC. Recent findings suggest that one major limitation in AMI performance is the inability to sufficiently activate neurons across the three-dimensional (3-D) IC. Unfortunately, there are no currently available 3-D array technologies that can be used for clinical applications. More recently, there has been a new initiative by the European Commission to fund and develop 3-D chronic electrode arrays for science and clinical applications through the NeuroProbes project that can overcome the bulkiness and limited 3-D configurations of currently available array technologies. As part of the NeuroProbes initiative, we investigated whether their new array technology could be potentially used for future AMI patients. Since the NeuroProbes technology had not yet been tested for electrical stimulation in an in vivo animal preparation, we performed experiments in ketamine-anesthetized guinea pigs in which we inserted and stimulated a NeuroProbes array within the IC and recorded the corresponding neural activation within the auditory cortex. We used 2-D arrays for this initial feasibility study since they were already available and were sufficient to access the IC and also demonstrate effective activation of the central auditory system. Based on these encouraging results and the ability to develop customized 3-D arrays with the NeuroProbes technology, we can further investigate different stimulation patterns across the ICC to improve AMI performance.

Proceedings of the National Academy of Sciences · Nov 2013

Serotonin selectively enhances perception and sensory neural responses to stimuli generated by same-sex conspecifics (opens in a new tab)

Tara Deemyad, Michael G. Metzen, Yingzhou Pan, Maurice J. Chacron

Abstract

Significance Serotonergic innervation of sensory areas is seen ubiquitously across species and systems, but its functional role remains unclear to this day. We used a systems level approach to investigate the functional role of serotonergic input onto electrosensory pyramidal neurons in the weakly electric fish Apteronotus leptorhynchus . We found that serotonin selectively improved neuronal responses to stimuli associated with same-sex conspecifics by inducing increased excitability and burst firing. Further, serotonin enhanced perception of these stimuli while simultaneously inhibiting aggressive behaviors. Our results provide the first evidence that the serotonergic system acts as a “shut up and listen” system, thereby favoring covert behavior after an aggressive encounter together with enhanced perception of stimuli associated with dominant conspecifics.

Journal of Neurophysiology · Oct 2013

Central dysmyelination reduces the temporal fidelity of synaptic transmission and the reliability of postsynaptic firing during high-frequency stimulation (opens in a new tab)

Sei Eun Kim, Karl Turkington, Christopher Kushmerick, Jun Hee Kim

Abstract

Auditory brain stem circuits rely on fast, precise, and reliable neurotransmission to process auditory information. To determine the fundamental role of myelination in auditory brain stem function, we examined the evoked auditory brain stem response (ABR) from the Long Evans shaker ( LES) rat, which lacks myelin due to a genetic deletion of myelin basic protein. In control rats, the ABR evoked by a click consisted of five well-defined waves (denoted waves I–V). In LES rats, waves I, IV, and V were present, but waves II and III were undetectable, indicating disrupted function in the earliest stages of central nervous system auditory processing. In addition, the developmental shortening of the interval between waves I and IV that normally occurs in control rats was arrested and resulted in a significant increase in the central conduction time in LES rats. In brain stem slices, action potential transmission between the calyx of Held terminals and the medial nucleus of the trapezoid body (MNTB) neurons was delayed and less reliable in LES rats, although the resting potential, threshold, input resistance, and length of the axon initial segment of the postsynaptic MNTB neurons were normal. The amplitude of glutamatergic excitatory postsynaptic currents (EPSCs) and the degree of synaptic depression during high-frequency stimulation were not different between LES rats and controls, but LES rats exhibited a marked slow component to the EPSC decay and a much higher rate of presynaptic failures. Together, these results indicate that loss of myelin disrupts brain stem auditory processing, increasing central conduction time and reducing the reliability of neurotransmission.

Graefe's Archive for Clinical and Experimental Ophthalmology = Albrecht von Graefes Archiv fur Klinische und Experimentelle Ophthalmologie · Sep 2013

Penetrating electrode stimulation of the rabbit optic nerve: parameters and effects on evoked cortical potentials (opens in a new tab)

Sun J, Chen Y, Chai X, … Li L

Abstract

Background Stimulus parameters, in particular pulse shape, are an important consideration in the application of electrical stimulation when experimentally testing a visual prosthesis. We changed the biphasic pulse shape of several asymmetric charge-balanced pulses to investigate their effect on optic nerve (ON) stimulation and the recorded cortical response. Methods Monopolar platinum-iridium electrodes were implanted into the rabbit's ON behind the eyeball. Electrical evoked potentials (EEPs) were recorded with silver ball electrodes placed on the cortex, and the results quantified. Results Our results indicate that changing the shape of cathodic-first charge-balanced biphasic pulse (CA) while maintaining charge balance could reduce the current thresholds for stimulation. When stimulated at the same charge density, the stimulus having high-amplitude short-duration (HASD) cathodic phase produced a higher amplitude response, with a larger spatial spread but with a lower current threshold compared with other stimuli. Adding an inter-phase gap between the two phases of the stimulus increased the EEP amplitude, but was saturated at a gap of ∼0.2 ms; this was most obvious with CA stimulation, which was able to elicit a larger cortical response than that elicited by asymmetrical charge-balanced stimulus pulses with HASD cathodic phase, in contrast to CA without a gap. As the stimulating frequency increased, the amplitudes of the EEP components elicited by CA monotonically decreased. The fastest component (P0) was present with stimulating frequencies as high as 80 Hz, while the slower P1 and P2 disappeared with stimulating frequencies higher than 40 and 20 Hz, respectively. Conclusion A CA stimulus waveform with an inter-phase gap of 0.2 ms was more efficacious for ON stimulation than other stimulus combinations, and therefore should result in less tissue damage, minimal electrode etching, and lower power consumption if used in a visual prosthesis.

Journal of Neural Engineering · Aug 2013

Multi-electrode stimulation in somatosensory cortex increases probability of detection (opens in a new tab)

Boubker Zaaimi, Ricardo Ruiz-Torres, Sara A Solla, Lee E Miller

Abstract

Objective: Brain machine interfaces (BMIs) that decode control signals from motor cortex have developed tremendously in the past decade, but virtually all rely exclusively on vision to provide feedback. There is now increasing interest in developing an afferent interface to replace natural somatosensation, much as the cochlear implant has done for the sense of hearing. Preliminary experiments toward a somatosensory neuroprosthesis have mostly addressed the sense of touch, but proprioception, the sense of limb position and movement, is also critical for the control of movement. However, proprioceptive areas of cortex lack the precise somatotopy of tactile areas. We showed previously that there is only a weak tendency for neighboring neurons in area 2 to signal similar directions of hand movement. Consequently, stimulation with the relatively large currents used in many studies is likely to activate a rather heterogeneous set of neurons. Approach: Here, we have compared the effect of single-electrode stimulation at subthreshold levels to the effect of stimulating as many as seven electrodes in combination. Main results: We found a mean enhancement in the sensitivity to the stimulus (d') of 0.17 for pairs compared to individual electrodes (an increase of roughly 30%), and an increase of 2.5 for groups of seven electrodes (260%). Significance: We propose that a proprioceptive interface made up of several hundred electrodes may yield safer, more effective sensation than a BMI using fewer electrodes and larger currents.

Journal of Neurophysiology · Aug 2013

Neural integration and enhancement from the inferior colliculus up to different layers of auditory cortex (opens in a new tab)

Straka MM, Schendel D, Lim HH

Abstract

While the cochlear implant has successfully restored hearing to many deaf patients, it cannot benefit those without a functional auditory nerve or an implantable cochlea. As an alternative, the auditory midbrain implant (AMI) has been developed and implanted into deaf patients. Consisting of a single-shank array, the AMI is designed for stimulation along the tonotopic gradient of the inferior colliculus (ICC). Although the AMI can provide frequency cues, it appears to insufficiently transmit temporal cues for speech understanding because repeated stimulation of a single site causes strong suppressive and refractory effects. Applying the electrical stimulation to at least two sites within an isofrequency lamina can circumvent these refractory processes. Moreover, coactivation with short intersite delays (<5 ms) can elicit cortical activation which is enhanced beyond the summation of activity induced by the individual sites. The goal of our study was to further investigate the role of the auditory cortex in this enhancement effect. In guinea pigs, we electrically stimulated two locations within an ICC lamina or along different laminae with varying interpulse intervals (0-10 ms) and recorded activity in different locations and layers of primary auditory cortex (A1). Our findings reveal a neural mechanism that integrates activity only from neurons located within the same ICC lamina for short spiking intervals (<6 ms). This mechanism leads to enhanced activity into layers III-V of A1 that is further magnified in supragranular layers. This integration mechanism may contribute to perceptual coding of different sound features that are relevant for improving AMI performance.

2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2013

Constant RMS versus constant peak modulation for the perceptual equivalence of sinusoidal amplitude modulated signals (opens in a new tab)

Oliver B. Regele, Andrew S. Koivuniemi, Kevin J. Otto

Abstract

Neuroprosthetics using intracortical microstimulation can potentially alleviate sensory deprivation due to injury or disease. However the information bandwidth of a single microstimulation channel remains largely unanswered. This paper presents three experiments that examine the importance of Peak Power/Charge and RMS Power/Charge for detection of acoustic and electrical Sinusoidal Amplitude Modulated stimuli by the auditory system. While the peripheral auditory system is sensitive to RMS power cues for the detection of acoustic stimuli, here we provide results that suggest that the auditory cortex is sensitive to peak charge cues for electrical stimuli. Varying the modulation frequency and depth do not change this effect for detection of modulated electrical stimuli.

The Journal of Neuroscience · Jun 2013

Encoding and retrieval of artificial visuoauditory memory traces in the auditory cortex requires the entorhinal cortex (opens in a new tab)

X. Chen, Y. Guo, J. Feng, … J. He

Abstract

Damage to the medial temporal lobe impairs the encoding of new memories and the retrieval of memories acquired immediately before the damage in human. In this study, we demonstrated that artificial visuoauditory memory traces can be established in the rat auditory cortex and that their encoding and retrieval depend on the entorhinal cortex of the medial temporal lobe in the rat. We trained rats to associate a visual stimulus with electrical stimulation of the auditory cortex using a classical conditioning protocol. After conditioning, we examined the associative memory traces electrophysiologically (i.e., visual stimulus-evoked responses of auditory cortical neurons) and behaviorally (i.e., visual stimulus-induced freezing and visual stimulus-guided reward retrieval). The establishment of a visuoauditory memory trace in the auditory cortex, which was detectable by electrophysiological recordings, was achieved over 20-30 conditioning trials and was blocked by unilateral, temporary inactivation of the entorhinal cortex. Retrieval of a previously established visuoauditory memory was also affected by unilateral entorhinal cortex inactivation. These findings suggest that the entorhinal cortex is necessary for the encoding and involved in the retrieval of artificial visuoauditory memory in the auditory cortex, at least during the early stages of memory consolidation.

Journal of NeuroEngineering and Rehabilitation · May 2013

In vitro and in vivo evaluation of a photosensitive polyimide thin-film microelectrode array suitable for epiretinal stimulation (opens in a new tab)

Xia Jiang, Xiaohong Sui, Yiliang Lu, … Xinyu Chai

Abstract

Background Epiretinal implants based on microelectro-mechanical system (MEMS) technology with a polyimide (PI) material are being proposed for application. Many kinds of non-photosensitive PIs have good biocompatibility and stability as typical MEMS materials for implantable electrodes. However, the effects of MEMS microfabrication, sterilization and implantation using a photosensitive polyimide (PSPI) microelectrode array for epiretinal electrical stimulation has not been extensively examined. Methods A novel PSPI (Durimide 7510) microelectrode array for epiretinal electrical stimulation was designed, fabricated based on MEMS processing and microfabrication techniques. The biocompatibility of our new microelectrode was tested in vitro using an MTT assay and direct contact tests between the microelectrode surface and cells. Electrochemical impedance characteristics were tested based on a three-electrode testing method. The reliability and stability was evaluated by a chronic implantation of a non-functional array within the rabbit eye. Histological examination and SEM were performed to monitor possible damage of the retina and microelectrodes. Electrically evoked potentials (EEPs) were recorded during the acute stimulation of the retina. Results The substrate was made of PSPI and the electrode material was platinum (Pt). The PSPI microelectrode array showed good biocompatibility and appropriate impedance characteristics for epiretinal stimulation. After a 6-month epiretinal implantation in the eyes of rabbits, we found no local retinal toxicity and no mechanical compression caused by the array. The Pt electrodes adhesion to the PSPI remained stable. A response to electrical stimuli was with recording electrodes lying on the visual cortex. Conclusion We provide a relevant design and fundamental characteristics of a PSPI microelectrode array. Strong evidences on testing indicate that implantation is safe in terms of mechanical pressure and biocompatibility of PSPI microelectrode arrays on the retina. The dual-layer process we used proffers considerable advantages over the more traditional single-layer approach and can accommodate much many electrode sites. This lays the groundwork for a future, high-resolution retinal prosthesis with many more electrode sites based on the flexible PSPI thin film substrate.

Journal of the Association for Research in Otolaryngology · Apr 2013

Modulation frequency discrimination with modulated and unmodulated interference in normal hearing and in cochlear-implant users (opens in a new tab)

Heather A. Kreft, David A. Nelson, Andrew J. Oxenham

Abstract

Differences in fundamental frequency (F0) provide an important cue for segregating simultaneous sounds. Cochlear implants (CIs) transmit F0 information primarily through the periodicity of the temporal envelope of the electrical pulse trains. Successful segregation of sounds with different F0s requires the ability to process multiple F0s simultaneously, but it is unknown whether CI users have this ability. This study measured modulation frequency discrimination thresholds for half-wave rectified sinusoidal envelopes modulated at 115 Hz in CI users and normal-hearing (NH) listeners. The target modulation was presented in isolation or in the presence of an interferer. Discrimination thresholds were strongly affected by the presence of an interferer, even when it was unmodulated and spectrally remote. Interferer modulation increased interference and often led to very high discrimination thresholds, especially when the interfering modulation frequency was lower than that of the target. Introducing a temporal offset between the interferer and the target led to at best modest improvements in performance in CI users and NH listeners. The results suggest no fundamental difference between acoustic and electric hearing in processing single or multiple envelope-based F0s, but confirm that differences in F0 are unlikely to provide a robust cue for perceptual segregation in CI users.

The Journal of Neuroscience · Apr 2013

Deep brain stimulation reduces Tic-related neural activity via temporal locking with stimulus pulses (opens in a new tab)

Kevin W. McCairn, Atsushi Iriki, Masaki Isoda

Abstract

A neurosurgical intervention that has shown potential for treating basal ganglia (BG) mediated motor tics involves high-frequency deep brain stimulation (HF-DBS) targeted to the output nucleus of the BG: the globus pallidus internus (GPi). This study used a nonhuman primate ( Macaca fuscata ) model of BG-meditated motor tics, and investigated the short-term neuronal mechanism that might underlie the beneficial effects of GPi-HF-DBS. In parallel with behavioral tic expressions, phasic alterations of neuronal activity emerged in the pallidum following focal disinhibition of the striatum with bicuculline. We delivered HF-DBS in the GPi in such a way that on-stimulation and off-stimulation conditions alternated every 30 s. Analysis of electromyographic (EMG) records showed that during on-stimulation, there were significant reductions in tic-related EMG amplitude. Analysis of pallidal activity showed that GPi-HF-DBS induced both sustained and transient patterns of excitation and inhibition in both segments of the GP. Population-scale firing rates were initially raised relative to baseline, but were not significantly different by the time stimulation ceased. Modulation of behavior and neuronal firing rates were associated with the reduction of tic-related phasic activity in pallidal cells. Examination of short-latency responses showed that firing rate changes were strongly associated with locking of the cells' activity with the HF-DBS pulse. This temporal locking often induced multiphasic changes of firing rates in individual cells, which dynamically changed across the stimulation period. These results support clinical studies that reported success in treating motor tics with GPi-HF-DBS, and demonstrate that the underlying local mechanism within the GP is suppression of tic-related activity through temporal locking with the stimulation pulse.

The Journal of the Acoustical Society of America · Apr 2013

Effect of mismatched place-of-stimulation on the salience of binaural cues in conditions that simulate bilateral cochlear-implant listening (opens in a new tab)

Matthew J. Goupell, Corey Stoelb, Alan Kan, Ruth Y. Litovsky

Abstract

Although bilateral cochlear implantation has the potential to improve sound localization and speech understanding in noise, obstacles exist in presenting maximally useful binaural information to bilateral cochlear-implant (CI) users. One obstacle is that electrode arrays may differ in cochlear position by several millimeters, thereby stimulating different neural populations. Effects of interaural frequency mismatch on binaural processing were studied in normal-hearing (NH) listeners using band-limited pulse trains, thereby avoiding confounding factors that may occur in CI users. In experiment 1, binaural image fusion was measured to capture perceptual number, location, and compactness. Subjects heard a single, compact image on 73% of the trials. In experiment 2, intracranial image location was measured for different interaural time differences (ITDs) and interaural level differences (ILDs). For larger mismatch, locations perceptually shifted towards the ear with the higher carrier frequency. In experiment 3, ITD and ILD just-noticeable differences (JNDs) were measured. JNDs increased with decreasing bandwidth and increasing mismatch, but were always measurable up to 3 mm of mismatch. If binaural-hearing mechanisms are similar between NH and CI subjects, these results may explain reduced sensitivity of ITDs and ILDs in CI users. Large mismatches may lead to distorted spatial maps and reduced binaural image fusion.

Journal of the Association for Research in Otolaryngology · Mar 2013

Direct recordings from the auditory cortex in a cochlear implant user (opens in a new tab)

Kirill V. Nourski, Christine P. Etler, John F. Brugge, … Matthew A. Howard

Abstract

Electrical stimulation of the auditory nerve with a cochlear implant (CI) is the method of choice for treatment of severe-to-profound hearing loss. Understanding how the human auditory cortex responds to CI stimulation is important for advances in stimulation paradigms and rehabilitation strategies. In this study, auditory cortical responses to CI stimulation were recorded intracranially in a neurosurgical patient to examine directly the functional organization of the auditory cortex and compare the findings with those obtained in normal-hearing subjects. The subject was a bilateral CI user with a 20-year history of deafness and refractory epilepsy. As part of the epilepsy treatment, a subdural grid electrode was implanted over the left temporal lobe. Pure tones, click trains, sinusoidal amplitude-modulated noise, and speech were presented via the auxiliary input of the right CI speech processor. Additional experiments were conducted with bilateral CI stimulation. Auditory event-related changes in cortical activity, characterized by the averaged evoked potential and event-related band power, were localized to posterolateral superior temporal gyrus. Responses were stable across recording sessions and were abolished under general anesthesia. Response latency decreased and magnitude increased with increasing stimulus level. More apical intracochlear stimulation yielded the largest responses. Cortical evoked potentials were phase-locked to the temporal modulations of periodic stimuli and speech utterances. Bilateral electrical stimulation resulted in minimal artifact contamination. This study demonstrates the feasibility of intracranial electrophysiological recordings of responses to CI stimulation in a human subject, shows that cortical response properties may be similar to those obtained in normal-hearing individuals, and provides a basis for future comparisons with extracranial recordings.

PLOS ONE · Feb 2013

Intracranial somatosensory responses with direct spinal cord stimulation in anesthetized sheep (opens in a new tab)

Oliver E. Flouty, Hiroyuki Oya, Hiroto Kawasaki, … Matthew A. Howard

Abstract

The efficacy of spinal cord stimulators is dependent on the ability of the device to functionally activate targeted structures within the spinal cord, while avoiding activation of near-by non-targeted structures. In theory, these objectives can best be achieved by delivering electrical stimuli directly to the surface of the spinal cord. The current experiments were performed to study the influence of different stimulating electrode positions on patterns of spinal cord electrophysiological activation. A custom-designed spinal cord neurostimulator was used to investigate the effects of lead position and stimulus amplitude on cortical electrophysiological responses to spinal cord stimulation. Brain recordings were obtained from subdural grids placed in four adult sheep. We systematically varied the position of the stimulating lead relative to the spinal cord and the voltage delivered by the device at each position, and then examined how these variables influenced cortical responses. A clear relationship was observed between voltage and electrode position, and the magnitude of high gamma-band oscillations. Direct stimulation of the dorsal column contralateral to the grid required the lowest voltage to evoke brain responses to spinal cord stimulation. Given the lower voltage thresholds associated with direct stimulation of the dorsal column, and its possible impact on the therapeutic window, this intradural modality may have particular clinical advantages over standard epidural techniques now in routine use.

Journal of Neurophysiology · Jan 2013

Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses (opens in a new tab)

Noah M. Ledbetter, Christian Ethier, Emily R. Oby, … Gregory A. Clark

Abstract

High-count microelectrode arrays implanted in peripheral nerves could restore motor function after spinal cord injury or sensory function after limb loss. In this study, we implanted Utah Slanted Electrode Arrays (USEAs) intrafascicularly at the elbow or shoulder in arm nerves of rhesus monkeys ( n = 4) under isoflurane anesthesia. Input-output curves indicated that pulse-width-modulated single-electrode stimulation in each arm nerve could recruit single muscles with little or no recruitment of other muscles. Stimulus trains evoked specific, natural, hand movements, which could be combined via multielectrode stimulation to elicit coordinated power or pinch grasp. Stimulation also elicited short-latency evoked potentials (EPs) in primary somatosensory cortex, which might be used to provide sensory feedback from a prosthetic limb. These results demonstrate a high-resolution, high-channel-count interface to the peripheral nervous system for restoring hand function after neural injury or disruption or for examining nerve structure.

teme · 2013

Selektive Ableitung und Stimulation für ein blutdrucksenkendes Implantat unter Verwendung von Vielkanal-Cuff-Elektroden. (opens in a new tab)

Dennis T. T. Plachta, Oscar Cota, Thomas Stieglitz, Mortimer Gierthmühlen

Abstract

Zusammenfassung Mit der Möglichkeit, blutdruckrelevante Fasern des N. vagus zu identifizieren und selektiv zu stimulieren, hat die Vagusnervstimulation das Potential, als Alternative zur Behandlung des therapierefraktären Blutdruckes etabliert zu werden. Die Selektivität dieser Stimulation ist essentiell, da eine unselektive Stimulation des gesamten N. vagus zu kardialen und gastrointestinalen Nebenwirkungen führen kann, die für eine chronische Therapie inakzeptabel sind. Durch den Einsatz von Vielkanal-Polyimid-Dünnfilm-Cuff-Elektroden ist es möglich, barorezeptiven Fasern im Vagusnerv zu lokalisieren und selektiv zu stimulieren. Hierzu werden die abgeleiteten neuronalen Signale in Echtzeit mit simultan aufgezeichneten EKG und Blutdrucksignalen korreliert, um diejenigen Elektroden zu identifizieren, welche den barorezeptiven Fasern am nächsten liegen. Der hierfür entwickelte Algorithmus basiert auf der kohärenten Mittelung und setzt keine dauerstabile Elektroden-Gewebe-Impedanz voraus. Die den blutdruckrelevanten Fasern am nächsten gelegenen Elektroden werden in tri- oder pentapolarer Konfiguration verwendet, um die Fasern selektiv zu stimulieren und über Aktivierung des Baroreflexes eine Blutdrucksenkung ohne relevante Bradykardie zu erreichen.