PA5 Programmable Attenuator
Used in 357 published studies →
TDT has built more than 2000 programmable attenuators over the last 25 years, improving and perfecting the design with each new hardware generation. Our latest version, the PA5 Programmable Attenuator, is a precision device for controlling signal levels over a wide dynamic range. The device is fully programmable; however, simple manual operation is also available using front panel controls.
Research Uses
Resources
Publications
- ABR & DPOAE
- Auditory research
- Tuning curves
357 published studies used the PA5. The newest:
Journal of Experimental Biology · Sep 2026
Song recognition in Floridian Ormia ochracea reflects multidimensional temporal tuning (opens in a new tab)
Abstract
Acoustic communication signals often contain a complex temporal structure, yet how this temporal structure contributes to signal recognition is poorly understood, particularly in eavesdropping receivers. The parasitoid fly Ormia ochracea localises host crickets by eavesdropping on their calling songs. In Florida, preferred host songs consist of sound pulses repeated at ∼50 pulses s−1, and flies exhibit matching preferences. However, it is unclear whether this preference reflects sensitivity to individual temporal parameters or to derived temporal relationships that emerge from their combination. We independently varied pulse duration and interpulse interval across a broad stimulus space and quantified tethered-walking phonotaxis using a switch-following paradigm. Behavioural responses formed a structured tuning surface, with elevated responses for pulse durations of ∼5–15 ms across a broad range of interpulse intervals, together with high performance along a diagonal corresponding to 50 pulses s−1. Responses failed to collapse across stimuli sharing the same pulse rate or pulse period, indicating that these parameters alone do not determine recognition. Models allowing behavioural responses to vary jointly across combinations of temporal parameters substantially outperformed models based on single parameters. Although pulse duration strongly constrained recognition, behavioural responses also varied systematically with interpulse interval and could not be explained by pulse duration, interpulse interval, pulse rate, pulse period or duty cycle alone. The apparent preference of O. ochracea for ∼50 pulses s−1 therefore represents one component of a broader temporal recognition landscape rather than recognition based on pulse rate alone.
bioRxiv · Sep 2026
SEDATION DIFFERENTIALLY AFFECTS DISTORTION-PRODUCT AND STIMULUS-FREQUENCY OTOACOUSTIC EMISSIONS IN CHINCHILLAS (opens in a new tab)
Abstract
Purpose Otoacoustic emissions (OAEs) are used to assess outer hair cell (OHC) function. Clinical interpretation of OAE responses, however, is often limited to a present/absent binary since both physiological factors and measurement variability affect the measured OAE amplitude. Prior work showed elevated OAE responses in sedated compared to awake chinchillas, pointing to the potential influence of the medial olivocochlear (MOC) efferents on amplitudes, but this finding is inconsistent across species and OAE type. Here, we aimed to further investigate the effect of anesthesia on distortion-and reflection-type emissions in chinchillas using swept stimuli and more reliable calibration methods. Methods Swept distortion-product (DP) and stimulus-frequency (SF) OAEs were measured in chinchillas with and without ketamine/xylazine sedation. Stimuli were presented using in-ear forward pressure level calibrations. DPOAE and SFOAE amplitudes and estimated Q erb from SFOAE group delays were compared across the two conditions. Results We found that low-frequency DPOAE amplitudes were elevated when animals were sedated. The difference in SFOAE amplitudes was more variable across animals but appeared mildly reduced in sedated animals. Q erb estimates were slightly higher in sedated animals at some frequencies. The effect of sedation was not different across sexes. Conclusion Taken together, these findings suggest that sedation impacts OAE measurements in chinchillas. MOC modulation could account for the present findings and differences across species. For diagnostic precision, OAE responses should be considered in the context of not only intrinsic OHC function but also extrinsic physiological processes that can modulate OHCs.
Scientific Reports · Sep 2026
Neuromagnetic representation of vowel prosody in the auditory cortex (opens in a new tab)
Abstract
A key feature of vowels in spoken language is that their fundamental frequency ( f 0 ), which underlies perceived pitch, can change dynamically over time. However, it remains elusive how such prosodic glides shape the neural response in the auditory cortex. The current magnetoencephalography (MEG) experiment was designed to study the transient and sustained neuromagnetic correlates of prosodic contour information in vowels, with a particular focus on the P2 component. Twenty-four normal-hearing participants passively listened to vowel sequences in which both vowel type and prosodic contour were either unchanged or varied between successive vowels. At the level of single vowels, the results showed that falling contours elicit larger and earlier P2 responses than rising and flat prosodic contours. At the level of vowel triplets, the P2 was larger in response to stimulus sequences in which prosodic contour was varied across stimuli. The data indicate that the P2 might be a neural correlate of the early processing of prosodic contour information; moreover, they suggest that the P2 might be particularly sensitive to pitch glides, possibly due to longer time constants that are encompassed within the P2.
How to cite the PA5
Name the model in your Methods so readers can find the equipment you used, for example:
PA5 Programmable Attenuator (Tucker-Davis Technologies, Alachua, FL, USA)
