TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

467 papers

Frontiers in Neuroscience · Feb 2021

Rapid and Low Cost Manufacturing of Cuff Electrodes (opens in a new tab)

Matthew T. Flavin, Marek A. Paul, Alexander S. Lim, … Jongyoon Han

Abstract

For many peripheral neuro-modulation applications, the cuff electrode has become a preferred technology for delivering electrical current into targeted volumes of tissue. While basic cuffs with low spatial selectivity, having longitudinally arranged contacts, can be produced from relatively straightforward processes, the fabrication of more complex electrode configurations typically requires iterative design and clean-room fabrication with skilled technicians. Although facile methods for fabricating cuff electrodes exist, their inconsistent products have limited their adoption for rapid manufacturing. In this article, we report a fast, low-cost fabrication process for patterning of electrode contacts in an implantable peripheral nerve cuff. Using a laser cutter as we have prescribed, the designer can render precise contact geometries that are consistent between batches. This method is enabled by the use of silicone/carbon black (CB) composite electrodes, which integrate with the patterned surface of its substrate—tubular silicone insulation. The size and features of its products can be adapted to fit a wide range of nerve diameters and applications. In this study, we specifically documented the manufacturing and evaluation of circumpolar cuffs with radial arrays of three contacts for acute implantation on the rat sciatic nerve. As part of this method, we also detail protocols for verification—electrochemical characterization—and validation—electrophysiological evaluation—of implantable cuff electrodes. Applied to our circumpolar cuff electrode, we report favorable electrical characteristics. In addition, we report that it reproduces expected electrophysiological behaviors described in prior literature. No specialized equipment or fabrication experience was required in our production, and we encountered negligible costs relative to commercially available solutions. Since, as we demonstrate, this process generates consistent and precise electrode geometries, we propose that it has strong merits for use in rapid manufacturing.

Nature · Jan 2021

Neuroprosthetic baroreflex controls haemodynamics after spinal cord injury (opens in a new tab)

Squair JW, Gautier M, Mahe L, … Phillips AA

Abstract

Spinal cord injury (SCI) induces haemodynamic instability that threatens survival 1-3 , impairs neurological recovery 4,5 , increases the risk of cardiovascular disease 6,7 , and reduces quality of life 8,9 . Haemodynamic instability in this context is due to the interruption of supraspinal efferent commands to sympathetic circuits located in the spinal cord 10 , which prevents the natural baroreflex from controlling these circuits to adjust peripheral vascular resistance. Epidural electrical stimulation (EES) of the spinal cord has been shown to compensate for interrupted supraspinal commands to motor circuits below the injury 11 , and restored walking after paralysis 12 . Here, we leveraged these concepts to develop EES protocols that restored haemodynamic stability after SCI. We established a preclinical model that enabled us to dissect the topology and dynamics of the sympathetic circuits, and to understand how EES can engage these circuits. We incorporated these spatial and temporal features into stimulation protocols to conceive a clinical-grade biomimetic haemodynamic regulator that operates in a closed loop. This 'neuroprosthetic baroreflex' controlled haemodynamics for extended periods of time in rodents, non-human primates and humans, after both acute and chronic SCI. We will now conduct clinical trials to turn the neuroprosthetic baroreflex into a commonly available therapy for people with SCI.

Journal of Neural Engineering · Jan 2021

The temporal pattern of intracortical microstimulation pulses elicits distinct temporal and spatial recruitment of cortical neuropil and neurons (opens in a new tab)

James R Eles, Kevin C Stieger, Takashi D Y Kozai

Abstract

Objective. The temporal spacing or distribution of stimulation pulses in therapeutic neurostimulation waveforms—referred to here as the Temporal Pattern (TP)—has emerged as an important parameter for tuning the response to deep-brain stimulation and intracortical microstimulation (ICMS). While it has long been assumed that modulating the TP of ICMS may be effective by altering the rate coding of the neural response, it is unclear how it alters the neural response at the network level. The present study is designed to elucidate the neural response to TP at the network level. Approach . We use in vivo two-photon imaging of mice expressing the calcium sensor Thy1 -GCaMP or the glutamate sensor hSyn -iGluSnFr to examine the layer II/III neural response to ICMS with different TPs. We study the neuronal calcium and glutamate response to TPs with the same average frequency (10 Hz) and same total charge injection, but varying degrees of bursting. We also investigate one control pattern with an average frequency of 100 Hz and 10X the charge injection. Main Results . Stimulation trains with the same average frequency and same total charge injection but distinct TPs recruit distinct sets of neurons. More than half (60% of 309 cells) of neurons prefer one TP over the other. Despite their distinct spatial recruitment patterns, cells exhibit similar ability to follow 30 s trains of both TPs without failing, and they exhibit similar levels of glutamate release during stimulation. Both neuronal calcium and glutamate release entrain to the bursting TP pattern, with a ∼21-fold increase in relative power at the frequency of bursting. Bursting also results in a statistically significant elevation in the correlation between somatic calcium activity and neuropil activity, which we explore as a metric for inhibitory-excitatory tone. Interestingly, soma-neuropil correlation during the bursting pattern is a statistically significant predictor of cell preference for TP, which exposes a key link between TP and inhibitory-excitatory tone. Finally, using mesoscale imaging, we show that both TPs result in distal inhibition during stimulation, which reveals complex spatial and temporal interactions between TP and inhibitory-excitatory tone in ICMS. Significance . Our results may ultimately suggest that TP is a valuable parameter space to modulate inhibitory-excitatory tone and to recruit distinct network activity in ICMS. This presents a broader mechanism of action than rate coding, as previously thought. By implicating these additional mechanisms, TP may have broader utility in the clinic and should be pursued to expand the efficacy of ICMS therapies.

Journal of NeuroEngineering and Rehabilitation · Jan 2021

Discriminability of multiple cutaneous and proprioceptive hand percepts evoked by intraneural stimulation with Utah slanted electrode arrays in human amputees (opens in a new tab)

David M. Page, Jacob A. George, Suzanne M. Wendelken, … Gregory A. Clark

Abstract

Background Electrical stimulation of residual afferent nerve fibers can evoke sensations from a missing limb after amputation, and bionic arms endowed with artificial sensory feedback have been shown to confer functional and psychological benefits. Here we explore the extent to which artificial sensations can be discriminated based on location, quality, and intensity. Methods We implanted Utah Slanted Electrode Arrays (USEAs) in the arm nerves of three transradial amputees and delivered electrical stimulation via different electrodes and frequencies to produce sensations on the missing hand with various locations, qualities, and intensities. Participants performed blind discrimination trials to discriminate among these artificial sensations. Results Participants successfully discriminated cutaneous and proprioceptive sensations ranging in location, quality and intensity. Performance was significantly greater than chance for all discrimination tasks, including discrimination among up to ten different cutaneous location-intensity combinations (15/30 successes, p < 0.0001) and seven different proprioceptive location-intensity combinations (21/40 successes, p < 0.0001). Variations in the site of stimulation within the nerve, via electrode selection, enabled discrimination among up to five locations and qualities (35/35 successes, p < 0.0001). Variations in the stimulation frequency enabled discrimination among four different intensities at the same location (13/20 successes, p < 0.0005). One participant also discriminated among individual stimulation of two different USEA electrodes, simultaneous stimulation on both electrodes, and interleaved stimulation on both electrodes (20/24 successes, p < 0.0001). Conclusion Electrode location, stimulation frequency, and stimulation pattern can be modulated to evoke functionally discriminable sensations with a range of locations, qualities, and intensities. This rich source of artificial sensory feedback may enhance functional performance and embodiment of bionic arms endowed with a sense of touch.

eLife · Jan 2021

Microsecond interaural time difference discrimination restored by cochlear implants after neonatal deafness (opens in a new tab)

Nicole Rosskothen-Kuhl, Alexa N Buck, Kongyan Li, Jan WH Schnupp

Abstract

Spatial hearing in cochlear implant (CI) patients remains a major challenge, with many early deaf users reported to have no measurable sensitivity to interaural time differences (ITDs). Deprivation of binaural experience during an early critical period is often hypothesized to be the cause of this shortcoming. However, we show that neonatally deafened (ND) rats provided with precisely synchronized CI stimulation in adulthood can be trained to lateralize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, comparable ND rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. Our result that ND-CI rats achieved very good behavioral ITD thresholds, while prelingually deaf human CI patients often fail to develop a useful sensitivity to ITD raises urgent questions concerning the possibility that shortcomings in technology or treatment, rather than missing input during early development, may be behind the usually poor binaural outcomes for current CI patients.

bioRxiv* · Dec 2020

A vision prosthesis based on electrical stimulation of the primary visual cortex using epicortical microelectrodes (opens in a new tab)

Denise Oswalt, P. Datta, N. Talbot, … Bradley Greger

Abstract

Prostheses that can restore limited vision in the profoundly blind have been under investigation for several decades. Studies using epicortical macroelectrodes and intracortical microelectrodes have validated that electrical stimulation of primary visual cortical can serve as the basis for a vision prosthesis. However, neither of these approaches has resulted in a clinically viable vision prosthesis. Epicortical macroelectrodes required high levels of electrical current to evoke visual percepts, while intracortical microelectrodes faced challenges with longevity and stability. We hypothesized that epicortical microelectrodes could evoke visual percepts at lower currents than macroelectrodes and provide improved longevity and stability compared with intracortical microelectrodes. To test this hypotheses we implanted epicortical microelectrode arrays over the primary visual cortex of a nonhuman primate. Electrical stimulation via this array was used to evaluate the ability of epicortical microstimulation to evoke differentiable visual percepts. Visual percepts were evoked using the epicortical microelectrode array, and at electrical currents notably lower than those required to evoke visual percepts on macroelectrode arrays. The electrical current thresholds for evoking visual percepts on the epicortical microelectrode array were consistent across multiple array implants and over several months. Normal vision of light perception was not impaired by multiple array implants or chronic electrical stimulation, demonstrating that no gross visual deficit resulted from the experiments. We specifically demonstrate that epicortical microelectrode interfaces can serve as the basis for a vision prosthesis and more generally may provide an approach to evoking perception in multiple sensory modalities. One Sentence Summary Electrical stimulation of the brain via microelectrodes resting on the surface of primary visual cortex can evoke multiple differentiable visual percepts.

UF Journal of Undergraduate Research · Nov 2020

Design of Pulse Oximeter Solution for Conscious Rodents (opens in a new tab)

Lauren Elizabeth Lester, Elliott Dirr, Kevin Otto

Abstract

Neuromodulation can be used to control organ function through exogenous augmentation of neural activity via targeted delivery of an electrical stimulus. Recently, neuromodulation has been a topic of investigation to treat many illnesses and conditions including Parkinson’s disease, epilepsy, obesity, chronic pain, type 1 diabetes, and hypertension. During neuromodulatory treatments, it is important to measure both the physiological response of the target system as well as any off-target systems that may be engaged from the delivered stimulus. Stimulation of the vagus nerve, a common target of neuromodulatory therapies, causes a vasovagal response which results in decreased cardiac rate and arteriolar dilatation. It is possible to measure these physiological parameters in anesthetized rats, but it is a challenge in conscious, moving rats because of motion artifact introduced to the sensors. By creating a noninvasive, stabilized pulse oximeter that measures the blood oxygenation waveform, one can analyze the heart rate in awake behaving animals. This study reports the design of a heart rate monitor used to monitor effects of heart rate variability during neuromodulation experiments. Design of this device included testing different sensors, methods of attaching to the rodent, microcontrollers, and wireless communication modules.

Journal of Neurophysiology · Nov 2020

Frequency-dependent spike-pattern changes in motor cortex during thalamic deep brain stimulation (opens in a new tab)

Edward M. Bello, Filippo Agnesi, Yizi Xiao, … Matthew D. Johnson

Abstract

The network mechanisms of thalamic deep brain stimulation (DBS) are not well understood at the cellular level. This study investigated the neuronal firing rate and pattern changes in the motor cortex resulting from stimulation of the cerebellar-receiving area of the motor thalamus. We showed that there is a nonintuitive relationship between general entropy-based spike-pattern measures and phase-locked regularization to DBS.

IEEJ Transactions on Electrical and Electronic Engineering · Sep 2020

Numerical Analysis of Microcoil‐Induced Electric Fields and Evaluation of In vivo Magnetic Stimulation of the Mouse Brain (opens in a new tab)

Shunsuke Sugai, Hisaya Higuchi, Jun Nishikawa, … Takashi Tateno

Abstract

Magnetic stimulation is widely used as a medical treatment for neurological diseases. A reduction in the size of magnetic stimulation devices is desirable, however, because the coils are relatively large compared with electrode stimulation devices. Furthermore, in transcranial magnetic stimulation, the exact magnetically evoked areas in the brain and the mechanisms of neural activation are largely unknown. This study aimed to develop a new implantable microcoil device that stimulates the brain locally, on the order of several tens of micrometers, as well as to understand the mechanisms of micromagnetic stimulation‐induced neural activity. First, to investigate the effects of microcoil shape on neural activation, the induced electric fields of semicircular microcoils with different diameters were calculated numerically in a microcoil model using the standard finite element method. Next, on the basis of the obtained numerical results from the microcoil model with different diameters, we compared the spatial properties of the possible activated areas in neural tissue and examined the most effective microcoil shape for neural activation. Finally, we measured microcoil‐evoked responses using autofluorescent flavoprotein imaging of the mouse brain in vivo , evaluated the validity of our proposed microcoil devices, and discussed possible future improvements for a chronic implant. © 2020 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.

Advanced Functional Materials · Sep 2020

High Fidelity Bidirectional Neural Interfacing with Carbon Fiber Microelectrodes Coated with Boron‐Doped Carbon Nanowalls: An Acute Study (opens in a new tab)

Maryam A. Hejazi, Wei Tong, Alastair Stacey, … David. J Garrett

Abstract

Abstract Implantable electrodes that can communicate with a small, selective group of neurons via both neural stimulation and recording are critical for the development of advanced neuroprosthetic devices. Microfiber electrodes with neuron‐scale cross‐sections have the potential to improve the spatial resolution for both stimulation and recording, while minimizing the chronic inflammation response after implantation. In this work, glass insulated microfiber electrodes are fabricated by coating carbon fibers with boron‐doped carbon nanowalls. The coating significantly improves the electrochemical properties of carbon fibers, leading to a charge injection capacity of 7.82 ± 0.35 mC cm−2, while retaining good flexibility, stability and biocompatibility. When used for neural interfacing, the coated microelectrodes successfully elicit localized stimulation responses in explanted retina, and are also able to detect signals from single neurons, in vivo with a signal‐to‐noise ratio as high as 6.7 in an acute study. This is the first report of using carbon nanowall coated carbon fibers for neural interfacing.

Neuroscience · Sep 2020

Lower baseline variability gives rise to Lower detection thresholds in midbrain than hindbrain electrosensory neurons (opens in a new tab)

Kim C, Chacron MJ

Abstract

Understanding how the brain decodes sensory information to give rise to behaviour remains an important problem in systems neuroscience. Across various sensory modalities (e.g. auditory, visual), the time-varying contrast of natural stimuli has been shown to carry behaviourally relevant information. However, it is unclear how such information is actually decoded by the brain to evoke perception and behaviour. Here we investigated how midbrain electrosensory neurons respond to weak contrasts in the electrosensory system of the weakly electric fish Apteronotus leptorhynchus. We found that these neurons displayed lower detection thresholds than their afferent hindbrain electrosensory neurons. Further analysis revealed that the lower detection thresholds of midbrain neurons were not due to increased sensitivity to the stimulus. Rather, these were due to the fact that midbrain neurons displayed lower variability in their firing activities in the absence of stimulation, which is due to lower firing rates. Our results suggest that midbrain neurons play an active role towards enabling the detection of weak stimulus contrasts, which in turn leads to perception and behavioral responses.

Aug 2020

Vagus Nerve Stimulation Evoked Electroneurography and Electromyography Recordings in Swine v1 (opens in a new tab)

Evan N Nicolai, Kip Ludwig

Abstract

This protocol was used to collect data now published in the Journal of Neural Engineering, Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs, see Metadata for citation. Additionally, the dataset is publicly available on Pennsieve 10.26275/qcuk-a8ty.

Nature Communications · Aug 2020

Single-trial cross-area neural population dynamics during long-term skill learning (opens in a new tab)

T. L. Veuthey, K. Derosier, S. Kondapavulur, K. Ganguly

Abstract

Mammalian cortex has both local and cross-area connections, suggesting vital roles for both local and cross-area neural population dynamics in cortically-dependent tasks, like movement learning. Prior studies of movement learning have focused on how single-area population dynamics change during short-term adaptation. It is unclear how cross-area dynamics contribute to movement learning, particularly long-term learning and skill acquisition. Using simultaneous recordings of rodent motor (M1) and premotor (M2) cortex and computational methods, we show how cross-area activity patterns evolve during reach-to-grasp learning in rats. The emergence of reach-related modulation in cross-area activity correlates with skill acquisition, and single-trial modulation in cross-area activity predicts reaction time and reach duration. Local M2 neural activity precedes local M1 activity, supporting top–down hierarchy between the regions. M2 inactivation preferentially affects cross-area dynamics and behavior, with minimal disruption of local M1 dynamics. Together, these results indicate that cross-area population dynamics are necessary for learned motor skills.

Journal of Neural Engineering · Aug 2020

A biomimetic electrical stimulation strategy to induce asynchronous stochastic neural activity (opens in a new tab)

Formento E, D'Anna E, Gribi S, et al.

Abstract

OBJECTIVE: Electrical stimulation is an effective method for artificially modulating the activity of the nervous system. However, current stimulation paradigms fail to reproduce the stochastic and asynchronous properties of natural neural activity. Here, we introduce a novel biomimetic stimulation (BioS) strategy that overcomes these limitations. APPROACH: We hypothesized that high-frequency amplitude-modulated bursts of stimulation could induce asynchronous neural firings by distributing recruitment over the duration of a burst, without sacrificing the ability to precisely control neural activity. We tested this hypothesis using computer simulations and ex vivo experiments. MAIN RESULTS: We found that BioS bursts induce asynchronous, stochastic, yet controllable, neural activity. We established that varying the amplitude, duration, and repetition frequency of a BioS burst enables graded modulation of the number of recruited fibers, their firing rate, and the synchronicity of their responses. SIGNIFICANCE: These results demonstrate an unprecedented level of control over artificially induced neural activity, enabling the design of next-generation BioS paradigms with potentially profound consequences for the field of neurostimulation.

Journal of Neural Engineering · Jul 2020

Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs (opens in a new tab)

Evan N Nicolai, Megan L Settell, Bruce E Knudsen, … Kip A Ludwig

Abstract

Objective Clinical data suggest that efficacious vagus nerve stimulation (VNS) is limited by side effects such as cough and dyspnea that have stimulation thresholds lower than those for therapeutic outcomes. VNS side effects are putatively caused by activation of nearby muscles within the neck, via direct muscle activation or activation of nerve fibers innervating those muscles. Our goal was to determine the thresholds at which various VNS-evoked effects occur in the domestic pig—an animal model with vagus anatomy similar to human—using the bipolar helical lead deployed clinically. Approach Intrafascicular electrodes were placed within the vagus nerve to record electroneurographic (ENG) responses, and needle electrodes were placed in the vagal-innervated neck muscles to record electromyographic (EMG) responses. Main results Contraction of the cricoarytenoid muscle occurred at low amplitudes (∼0.3 mA) and resulted from activation of motor nerve fibers in the cervical vagus trunk within the electrode cuff which bifurcate into the recurrent laryngeal branch of the vagus. At higher amplitudes (∼1.4 mA), contraction of the cricoarytenoid and cricothyroid muscles was generated by current leakage outside the cuff to activate motor nerve fibers running within the nearby superior laryngeal branch of the vagus. Activation of these muscles generated artifacts in the ENG recordings that may be mistaken for compound action potentials representing slowly conducting Aδ-, B-, and C-fibers. Significance Our data resolve conflicting reports of the stimulation amplitudes required for C-fiber activation in large animal studies (>10 mA) and human studies (<250 μ A). After removing muscle-generated artifacts, ENG signals with post-stimulus latencies consistent with Aδ- and B-fibers occurred in only a small subset of animals, and these signals had similar thresholds to those that caused bradycardia. By identifying specific neuroanatomical pathways that cause off-target effects and characterizing the stimulation dose-response curves for on- and off-target effects, we hope to guide interpretation and optimization of clinical VNS.

Frontiers in Neuroscience · Jul 2020

Optimal Multichannel Artifact Prediction and Removal for Neural Stimulation and Brain Machine Interfaces (opens in a new tab)

Mina Sadeghi Najafabadi, Longtu Chen, Kelsey Dutta, … Monty A. Escabí

Abstract

Neural implants that deliver multi-site electrical stimulation to the nervous systems are no longer the last resort but routine treatment options for various neurological disorders. Multi-site electrical stimulation is also widely used to study nervous system function and neural circuit transformations. These technologies increasingly demand dynamic electrical stimulation and closed-loop feedback control for real-time assessment of neural function, which is technically challenging since stimulus-evoked artifacts overwhelm the small neural signals of interest. We report a novel and versatile artifact removal method that can be applied in a variety of settings, from single- to multi-site stimulation and recording and for current waveforms of arbitrary shape and size. The method capitalizes on linear electrical coupling between stimulating currents and recording artifacts, which allows us to estimate a multi-channel linear Wiener filter to predict and subsequently remove artifacts via subtraction. We confirm and verify the linearity assumption and demonstrate feasibility in a variety of recording modalities, including in vitro sciatic nerve stimulation, bilateral cochlear implant stimulation, and multi-channel stimulation and recording between the auditory midbrain and cortex. We demonstrate a vast enhancement in the recording quality with a typical artifact reduction of 25-40 dB. The method is efficient and can be scaled to arbitrary number of stimulus and recording sites, making it ideal for applications in large-scale arrays, closed-loop implants, and high-resolution multi-channel brain-machine interfaces.

Frontiers in Integrative Neuroscience · Jul 2020

Serotonergic Modulation of Sensory Neuron Activity and Behavior in Apteronotus albifrons (opens in a new tab)

Mariana M. Marquez, Maurice J. Chacron

Abstract

Organisms must constantly adapt to changes in their environment to survive. It is thought that neuromodulators such as serotonin enable sensory neurons to better process input encountered during different behavioral contexts. Here, we investigated how serotonergic innervation affects neural and behavioral responses to behaviorally relevant envelope stimuli in the weakly electric fish species Apteronotus albifrons. Under baseline conditions, we found that exogenous serotonin application within the electrosensory lateral line lobe increased sensory neuron excitability, thereby promoting burst firing. We found that serotonin enhanced the responses to envelope stimuli of pyramidal cells within the lateral segment of the electrosensory lateral line lobe (ELL) by increasing sensitivity, with the increase more pronounced for stimuli with higher temporal frequencies (i.e., >0.2 Hz). Such increases in neural sensitivity were due to increased burst firing. At the organismal level, bilateral serotonin application within the ELL lateral segment enhanced behavioral responses to sensory input through increases in sensitivity. Similar to what was observed for neural responses, increases in behavioral sensitivity were more pronounced for higher (i.e., >0.2 Hz) temporal frequencies. Surprisingly, a comparison between our results and previous ones obtained in the closely related species A. leptorhynchus revealed that, while serotonin application gave rise to similar effects on neural excitability and responses to sensory input, serotonin application also gave rise to marked differences in behavior. Specifically, behavioral responses in A. leptorhynchus were increased primarily for lower (i.e., ≤0.2 Hz) rather than for higher temporal frequencies. Thus, our results strongly suggest that there are marked differences in how sensory neural responses are processed downstream to give rise to behavior across both species. This is even though previous results have shown that the behavioral responses of both species to envelope stimuli were identical when serotonin is not applied.

Journal of Neuroscience Research · Jun 2020

In vivo microstimulation with cathodic and anodic asymmetric waveforms modulates spatiotemporal calcium dynamics in cortical neuropil and pyramidal neurons of male mice (opens in a new tab)

Kevin C. Stieger, James R. Eles, Kip A. Ludwig, Takashi D. Y. Kozai

Abstract

Electrical stimulation has been critical in the development of an understanding of brain function and disease. Despite its widespread use and obvious clinical potential, the mechanisms governing stimulation in the cortex remain largely unexplored in the context of pulse parameters. Modeling studies have suggested that modulation of stimulation pulse waveform may be able to control the probability of neuronal activation to selectively stimulate either cell bodies or passing fibers depending on the leading polarity. Thus, asymmetric waveforms with equal charge per phase (i.e., increasing the leading phase duration and proportionately decreasing the amplitude) may be able to activate a more spatially localized or distributed population of neurons if the leading phase is cathodic or anodic, respectively. Here, we use two‐photon and mesoscale calcium imaging of GCaMP6s expressed in excitatory pyramidal neurons of male mice to investigate the role of pulse polarity and waveform asymmetry on the spatiotemporal properties of direct neuronal activation with 10‐Hz electrical stimulation. We demonstrate that increasing cathodic asymmetry effectively reduces neuronal activation and results in a more spatially localized subpopulation of activated neurons without sacrificing the density of activated neurons around the electrode. Conversely, increasing anodic asymmetry increases the spatial spread of activation and highly resembles spatiotemporal calcium activity induced by conventional symmetric cathodic stimulation. These results suggest that stimulation polarity and asymmetry can be used to modulate the spatiotemporal dynamics of neuronal activity thus increasing the effective parameter space of electrical stimulation to restore sensation and study circuit dynamics.

* Preprint: not yet peer reviewed.