Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

742 papers

Pharmaceutics · Feb 2023

Dual Drug Delivery in Cochlear Implants: In Vivo Study of Dexamethasone Combined with Diclofenac or Immunophilin Inhibitor MM284 in Guinea Pigs (opens in a new tab)

Wiebke Behrends, Katharina Wulf, Stefan Raggl, … Gerrit Paasche

Abstract

Cochlear implants are well established to treat severe hearing impairments. Despite many different approaches to reduce the formation of connective tissue after electrode insertion and to keep electrical impedances low, results are not yet satisfying. Therefore, the aim of the current study was to combine the incorporation of 5% dexamethasone in the silicone body of the electrode array with an additional polymeric coating releasing diclofenac or the immunophilin inhibitor MM284, some anti-inflammatory substances not yet tested in the inner ear. Guinea pigs were implanted for four weeks and hearing thresholds were determined before implantation and after the observation time. Impedances were monitored over time and, finally, connective tissue and the survival of spiral ganglion neurons (SGNs) were quantified. Impedances increased in all groups to a similar extent but this increase was delayed in the groups with an additional release of diclofenac or MM284. Using Poly-L-lactide (PLLA)-coated electrodes, the damage caused during insertion was much higher than without the coating. Only in these groups, connective tissue could extend to the apex of the cochlea. Despite this, numbers of SGNs were only reduced in PLLA and PLLA plus diclofenac groups. Even though the polymeric coating was not flexible enough, MM284 seems to especially have potential for further evaluation in connection with cochlear implantation.

Frontiers in Human Neuroscience · Feb 2023

Human subthalamic nucleus neurons differentially encode speech and limb movement (opens in a new tab)

Karim Johari, Ryan M. Kelley, Kris Tjaden, … Jeremy D. W. Greenlee

Abstract

Deep brain stimulation (DBS) of the subthalamic nucleus (STN), which consistently improves limb motor functions, shows mixed effects on speech functions in Parkinson’s disease (PD). One possible explanation for this discrepancy is that STN neurons may differentially encode speech and limb movement. However, this hypothesis has not yet been tested. We examined how STN is modulated by limb movement and speech by recording 69 single- and multi-unit neuronal clusters in 12 intraoperative PD patients. Our findings indicated: (1) diverse patterns of modulation in neuronal firing rates in STN for speech and limb movement; (2) a higher number of STN neurons were modulated by speech vs. limb movement; (3) an overall increase in neuronal firing rates for speech vs. limb movement; and (4) participants with longer disease duration had higher firing rates. These data provide new insights into the role of STN neurons in speech and limb movement.

Scientific Reports · Feb 2023

Classification of electrically-evoked potentials in the parkinsonian subthalamic nucleus region (opens in a new tab)

Joshua Rosing, Alex Doyle, AnneMarie Brinda, … Matthew D. Johnson

Abstract

Electrically evoked compound action potentials (ECAPs) generated in the subthalamic nucleus (STN) contain features that may be useful for titrating deep brain stimulation (DBS) therapy for Parkinson’s disease. Delivering a strong therapeutic effect with DBS therapies, however, relies on selectively targeting neural pathways to avoid inducing side effects. In this study, we investigated the spatiotemporal features of ECAPs in and around the STN across parameter sweeps of stimulation current amplitude, pulse width, and electrode configuration, and used a linear classifier of ECAP responses to predict electrode location. Four non-human primates were implanted unilaterally with either a directional (n = 3) or non-directional (n = 1) DBS lead targeting the sensorimotor STN. ECAP responses were characterized by primary features (within 1.6 ms after a stimulus pulse) and secondary features (between 1.6 and 7.4 ms after a stimulus pulse). Using these features, a linear classifier was able to accurately differentiate electrodes within the STN versus dorsal to the STN in all four subjects. ECAP responses varied systematically with recording and stimulating electrode locations, which provides a subject-specific neuroanatomical basis for selecting electrode configurations in the treatment of Parkinson’s disease with DBS therapy.

Nature Neuroscience · Feb 2023

Integrated cardio-behavioral responses to threat define defensive states (opens in a new tab)

Jérémy Signoret-Genest, Nina Schukraft, Sara L. Reis, … Philip Tovote

Abstract

Fear and anxiety are brain states that evolved to mediate defensive responses to threats. The defense reaction includes multiple interacting behavioral, autonomic and endocrine adjustments, but their integrative nature is poorly understood. In particular, although threat has been associated with various cardiac changes, there is no clear consensus regarding the relevance of these changes for the integrated defense reaction. Here we identify rapid microstates that are associated with specific behaviors and heart rate dynamics, which are affected by long-lasting macrostates and reflect context-dependent threat levels. In addition, we demonstrate that one of the most commonly used defensive behavioral responses—freezing as measured by immobility—is part of an integrated cardio-behavioral microstate mediated by Chx10 + neurons in the periaqueductal gray. Our framework for systematic integration of cardiac and behavioral readouts presents the basis for a better understanding of complex neural defensive states and their associated systemic functions.

Frontiers in Neuroscience · Feb 2023

Acute effects of cochleostomy and electrode-array insertion on compound action potentials in normal-hearing guinea pigs (opens in a new tab)

Saad Jwair, Dyan Ramekers, Hans G. X. M. Thomeer, Huib Versnel

Abstract

Introduction Electrocochleography (ECochG) is increasingly used in cochlear implant (CI) surgery, in order to monitor the effect of insertion of the electrode array aiming to preserve residual hearing. However, obtained results are often difficult to interpret. Here we aim to relate changes in ECochG responses to acute trauma induced by different stages of cochlear implantation by performing ECochG at multiple time points during the procedure in normal-hearing guinea pigs. Materials and methods Eleven normal-hearing guinea pigs received a gold-ball electrode that was fixed in the round-window niche. ECochG recordings were performed during the four steps of cochlear implantation using the gold-ball electrode: (1) Bullostomy to expose the round window, (2) hand-drilling of 0.5–0.6 mm cochleostomy in the basal turn near the round window, (3) insertion of a short flexible electrode array, and (4) withdrawal of electrode array. Acoustical stimuli were tones varying in frequency (0.25–16 kHz) and sound level. The ECochG signal was primarily analyzed in terms of threshold, amplitude, and latency of the compound action potential (CAP). Midmodiolar sections of the implanted cochleas were analyzed in terms of trauma to hair cells, modiolar wall, osseous spiral lamina (OSL) and lateral wall. Results Animals were assigned to cochlear trauma categories: minimal ( n = 3), moderate ( n = 5), or severe ( n = 3). After cochleostomy and array insertion, CAP threshold shifts increased with trauma severity. At each stage a threshold shift at high frequencies (4–16 kHz) was accompanied with a threshold shift at low frequencies (0.25–2 kHz) that was 10–20 dB smaller. Withdrawal of the array led to a further worsening of responses, which probably indicates that insertion and removal trauma affected the responses rather than the mere presence of the array. In two instances, CAP threshold shifts were considerably larger than threshold shifts of cochlear microphonics, which could be explained by neural damage due to OSL fracture. A change in amplitudes at high sound levels was strongly correlated with threshold shifts, which is relevant for clinical ECochG performed at one sound level. Conclusion Basal trauma caused by cochleostomy and/or array insertion should be minimized in order to preserve the low-frequency residual hearing of CI recipients.

Journal of Neural Engineering · Feb 2023

Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect (opens in a new tab)

Stephan L Blanz, Eric D Musselman, Megan L Settell, … Kip A Ludwig

Abstract

Electrical stimulation of the cervical vagus nerve using implanted electrodes (VNS) is FDA-approved for the treatment of drug-resistant epilepsy, treatment-resistant depression, and most recently, chronic ischemic stroke rehabilitation. However, VNS is critically limited by the unwanted stimulation of nearby neck muscles—a result of non-specific stimulation activating motor nerve fibers within the vagus. Prior studies suggested that precise placement of small epineural electrodes can modify VNS therapeutic effects, such as cardiac responses. However, it remains unclear if placement can alter the balance between intended effect and limiting side effect. We used an FDA investigational device exemption approved six-contact epineural cuff to deliver VNS in pigs and quantified how epineural electrode location impacts on- and off-target VNS activation. Detailed post-mortem histology was conducted to understand how the underlying neuroanatomy impacts observed functional responses. Here we report the discovery and characterization of clear neuroanatomy-dependent differences in threshold and saturation for responses related to both effect (change in heart rate) and side effect (neck muscle contractions). The histological and electrophysiological data were used to develop and validate subject-specific computation models of VNS, creating a well-grounded quantitative framework to optimize electrode location-specific activation of nerve fibers governing intended effect versus unwanted side effect.

Jan 2023

Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect v1 (opens in a new tab)

Stephan L Blanz

Abstract

This protocol was used to collect data now published in the Journal of Neural Engineering, Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect using the multi-contact ImThera stimulating device. https://doi.org/10.1088/1741-2552/acb3fd Dataset has been published to pennsieve.io and can be found at: https://doi.org/10.26275/efbj-8evl

Frontiers in Neuroscience · Jan 2023

Temporal hyper-precision of brainstem neurons alters spatial sensitivity of binaural auditory processing with cochlear implants (opens in a new tab)

Michaela Müller, Hongmei Hu, Mathias Dietz, … Michael Pecka

Abstract

The ability to localize a sound source in complex environments is essential for communication and navigation. Spatial hearing relies predominantly on the comparison of differences in the arrival time of sound between the two ears, the interaural time differences (ITDs). Hearing impairments are highly detrimental to sound localization. While cochlear implants (CIs) have been successful in restoring many crucial hearing capabilities, sound localization via ITD detection with bilateral CIs remains poor. The underlying reasons are not well understood. Neuronally, ITD sensitivity is generated by coincidence detection between excitatory and inhibitory inputs from the two ears performed by specialized brainstem neurons. Due to the lack of electrophysiological brainstem recordings during CI stimulation, it is unclear to what extent the apparent deficits are caused by the binaural comparator neurons or arise already on the input level. Here, we use a bottom-up approach to compare response features between electric and acoustic stimulation in an animal model of CI hearing. Conducting extracellular single neuron recordings in gerbils, we find severe hyper-precision and moderate hyper-entrainment of both the excitatory and inhibitory brainstem inputs to the binaural comparator neurons during electrical pulse-train stimulation. This finding establishes conclusively that the binaural processing stage must cope with highly altered input statistics during CI stimulation. To estimate the consequences of these effects on ITD sensitivity, we used a computational model of the auditory brainstem. After tuning the model parameters to match its response properties to our physiological data during either stimulation type, the model predicted that ITD sensitivity to electrical pulses is maintained even for the hyper-precise inputs. However, the model exhibits severely altered spatial sensitivity during electrical stimulation compared to acoustic: while resolution of ITDs near midline was increased, more lateralized adjacent source locations became inseparable. These results directly resemble recent findings in rodent and human CI listeners. Notably, decreasing the phase-locking precision of inputs during electrical stimulation recovered a wider range of separable ITDs. Together, our findings suggest that a central problem underlying the diminished ITD sensitivity in CI users might be the temporal hyper-precision of inputs to the binaural comparator stage induced by electrical stimulation.

IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2023

Glassy Carbon Neural Interface for Chronic Epidural Stimulation in Rats With Cervical Spinal Cord Injury (opens in a new tab)

Soshi Samejima, Rita Hanna, Brinda K. Cariappa, … Sam Kassegne

Abstract

There is growing evidence on the efficacy of electrical stimulation delivered via spinal neural interfaces to improve functional recovery following spinal cord injury. For such interfaces, carbon-based neural arrays are fast becoming recognized as a compelling material and platform due to biocompatibility and long-term electrochemical stability. Here, we introduce the design, fabrication, and in vivo characterization of a novel cervical epidural implant with carbon-based surface electrodes. Through finite element analysis and mechanical load tests, we demonstrated that the array could safely withstand loads applied to it during implantation and natural movement of the subject with minimal stress levels. Furthermore, the long-term in vivo performance of this neural array consisting of glassy carbon surface electrodes was investigated through acute and chronic spinal motor evoked potential recordings and electrode impedance tests in rats. We demonstrated stable stimulation performance for at least four weeks in a rat model of spinal cord injury. Lastly, we found that impedance measurements on all carbon-based spinal arrays were generally stable over time up to four weeks after implantation, with a slight increase in impedance in subsequent weeks when tested in spinally injured rats. Taken together, this study demonstrated the potential for carbon-based electrodes as a spinal neural interface to accelerate both mechanistic research and functional restoration in animal models of spinal cord injury.

eneuro · 2023

Neonatal Deafening Selectively Degrades the Sensitivity to Interaural Time Differences of Electrical Stimuli in Low-Frequency Pathways in Rats (opens in a new tab)

Woongsang Sunwoo

Abstract

We examined the effect of neonatal deafening on frequency-specific pathways for processing of interaural time differences (ITDs) in cochlear-implant stimuli. Animal studies have demonstrated differences in neural ITD sensitivity in the inferior colliculus (IC) depending on the intracochlear location of intracochlear stimulating electrodes. We used neonatally deafened (ND) rats of both sexes and recorded the responses of single neurons in the IC to electrical stimuli with ITDs delivered to the apical or basal cochlea and compared them with acutely deafened (AD) rats of both sexes with normal hearing (NH) during development. We found that neonatal deafness significantly impacted the ITD sensitivity and the ITD tuning patterns restricted to apically driven IC neurons. In ND rats, the ITD sensitivity of apically driven neurons is reduced to values similar to basally driven neurons. The prevalence of ITD-sensitive apical neurons with a peak-shaped ITD tuning curve, which may reflect predominant input from the medial superior olivary (MSO) complex, in ND rats was diminished compared with that in AD rats (67%, AD vs 40%, ND). Conversely, monotonic-type responses rarely occurred in AD rats (14%) but were approximately equally as prevalent as peak-type tuning curves in ND rats (42%). Nevertheless, in ND rats, the ITD at the maximum slope of the ITD tuning curve was still more concentrated within the physiological ITD range in apically driven than in basally driven neurons. These results indicate that the development of high ITD sensitivity processed by low-frequency pathways depends on normal auditory experience and associated biases in ITD tuning strategies.

Trends in Hearing · 2023

Hearing Asymmetry Biases Spatial Hearing in Bimodal Cochlear-Implant Users Despite Bilateral Low-Frequency Hearing Preservation (opens in a new tab)

Snandan Sharma, Lucas H.M. Mens, Ad F.M. Snik, … Marc M. van Wanrooij

Abstract

Many cochlear implant users with binaural residual (acoustic) hearing benefit from combining electric and acoustic stimulation (EAS) in the implanted ear with acoustic amplification in the other. These bimodal EAS listeners can potentially use low-frequency binaural cues to localize sounds. However, their hearing is generally asymmetric for mid- and high-frequency sounds, perturbing or even abolishing binaural cues. Here, we investigated the effect of a frequency-dependent binaural asymmetry in hearing thresholds on sound localization by seven bimodal EAS listeners. Frequency dependence was probed by presenting sounds with power in low-, mid-, high-, or mid-to-high-frequency bands. Frequency-dependent hearing asymmetry was present in the bimodal EAS listening condition (when using both devices) but was also induced by independently switching devices on or off. Using both devices, hearing was near symmetric for low frequencies, asymmetric for mid frequencies with better hearing thresholds in the implanted ear, and monaural for high frequencies with no hearing in the non-implanted ear. Results show that sound-localization performance was poor in general. Typically, localization was strongly biased toward the better hearing ear. We observed that hearing asymmetry was a good predictor for these biases. Notably, even when hearing was symmetric a preferential bias toward the ear using the hearing aid was revealed. We discuss how frequency dependence of any hearing asymmetry may lead to binaural cues that are spatially inconsistent as the spectrum of a sound changes. We speculate that this inconsistency may prevent accurate sound-localization even after long-term exposure to the hearing asymmetry.

IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2023

Neural Stimulation Hardware for the Selective Intrafascicular Modulation of the Vagus Nerve (opens in a new tab)

I. Strauss, F. Agnesi, C. Zinno, … S. Micera

Abstract

The neural stimulation of the vagus nerve is able to modulate various functions of the parasympathetic response in different organs. The stimulation of the vagus nerve is a promising approach to treating inflammatory diseases, obesity, diabetes, heart failure, and hypertension. The complexity of the vagus nerve requires highly selective stimulation, allowing the modulation of target-specific organs without side effects. Here, we address this issue by adapting a neural stimulator and developing an intraneural electrode for the particular modulation of the vagus nerve. The neurostimulator parameters such as amplitude, pulse width, and pulse shape were modulated. Single-, and multi-channel stimulation was performed at different amplitudes. For the first time, a polyimide thin-film neural electrode was designed for the specific stimulation of the vagus nerve. In vivo experiments were performed in the adult minipig to validate to elicit electrically evoked action potentials and to modulate physiological functions, validating the spatial selectivity of intraneural stimulation. Electrochemical tests of the electrode and the neurostimulator showed that the stimulation hardware was working correctly. Stimulating the porcine vagus nerve resulted in spatially selective modulation of the vagus nerve. ECAP belonging to alpha and beta fibers could be distinguished during single- and multi-channel stimulation. We have shown that the here presented system is able to activate the vagus nerve and can therefore modulate the heart rate, diastolic pressure, and systolic pressure. The here presented system may be used to restore the cardiac loop after denervation by implementing biomimetic stimulation patterns. Presented methods may be used to develop intraneural electrodes adapted for various applications.

Nature · Dec 2022

Locus coeruleus activity improves cochlear implant performance (opens in a new tab)

Erin Glennon, Silvana Valtcheva, Angela Zhu, … Robert C. Froemke

Abstract

Cochlear implants (CIs) are neuroprosthetic devices that can provide hearing to deaf people1. Despite the benefits offered by CIs, the time taken for hearing to be restored and perceptual accuracy after long-term CI use remain highly variable2,3. CI use is believed to require neuroplasticity in the central auditory system, and differential engagement of neuroplastic mechanisms might contribute to the variability in outcomes4-7. Despite extensive studies on how CIs activate the auditory system4,8-12, the understanding of CI-related neuroplasticity remains limited. One potent factor enabling plasticity is the neuromodulator noradrenaline from the brainstem locus coeruleus (LC). Here we examine behavioural responses and neural activity in LC and auditory cortex of deafened rats fitted with multi-channel CIs. The rats were trained on a reward-based auditory task, and showed considerable individual differences of learning rates and maximum performance. LC photometry predicted when CI subjects began responding to sounds and longer-term perceptual accuracy. Optogenetic LC stimulation produced faster learning and higher long-term accuracy. Auditory cortical responses to CI stimulation reflected behavioural performance, with enhanced responses to rewarded stimuli and decreased distinction between unrewarded stimuli. Adequate engagement of central neuromodulatory systems is thus a potential clinically relevant target for optimizing neuroprosthetic device use.

Scientific Reports · Dec 2022

Efficacy of bone stimulators in large-animal models and humans may be limited by weak electric fields reaching fracture (opens in a new tab)

Nishant Verma, Todd Le, Jonah Mudge, … Aaron M. Dingle

Abstract

Noninvasive electronic bone growth stimulators (EBGSs) have been in clinical use for decades. However, systematic reviews show inconsistent and limited clinical efficacy. Further, noninvasive EBGS studies in small animals, where the stimulation electrode is closer to the fracture site, have shown promising efficacy, which has not translated to large animals or humans. We propose that this is due to the weaker electric fields reaching the fracture site when scaling from small animals to large animals and humans. To address this gap, we measured the electric field strength reaching the bone during noninvasive EBGS therapy in human and sheep cadaver legs and in finite element method (FEM) models of human and sheep legs. During application of 1100 V/m with an external EBGS, only 21 V/m reached the fracture site in humans. Substantially weaker electric fields reached the fracture site during the later stages of healing and at increased bone depths. To augment the electric field strength reaching the fracture site during noninvasive EBGS therapy, we introduced the Injectrode, an injectable electrode that spans the distance between the bone and subcutaneous tissue. Our study lays the groundwork to improve the efficacy of noninvasive EBGSs by increasing the electric field strength reaching the fracture site.

bioRxiv · Dec 2022

A spatial code for temporal cues is necessary for sensory learning (opens in a new tab)

Sophie Bagur, Jacques Bourg, Alexandre Kempf, … Brice Bathellier

Abstract

The temporal structure of sensory inputs contains essential information for their interpretation by the brain 1–9 . Sensory systems represent these temporal cues through two codes: the temporal sequences of neuronal activity and the spatial patterns of neuronal firing rate 3,7,10–20 . However, it is still unknown which of these two coexisting codes causally drives sensory decisions 3,10,20,21 . To separate their contributions, we designed an optogenetic stimulation paradigm in the mouse auditory cortex to generate neuronal activity patterns differing exclusively along their temporal or spatial dimensions. Training mice to discriminate these patterns shows that they efficiently learn to discriminate spatial but not temporal patterns, indicating that spatial representations are necessary for sensory learning. In line with this result, we observed, based on large-scale neuronal recordings of the auditory system, that the auditory cortex is the first region in which spatial patterns efficiently represent temporal auditory cues varying over several hundred milliseconds. This feature is shared by the deep layers of neural networks trained to categorise time-varying sounds. Therefore, the emergence of a spatial code for temporal sensory cues is a necessary condition to associate temporally structured stimuli to decisions. We expect this constraint to be crucial for re-engineering perception by cortical stimulation.

Cell Reports Methods · Dec 2022

Enhanced perceptual task performance without deprivation in mice using medial forebrain bundle stimulation (opens in a new tab)

Antonin Verdier, Noémi Dominique, Déborah Groussard, … Sophie Bagur

Abstract

Perceptual decision-making tasks are essential to many fields of neuroscience. Current protocols generally reward deprived animals with water. However, balancing animals' deprivation level with their well-being is challenging, and trial number is limited by satiation. Here, we present electrical stimulation of the medial forebrain bundle (MFB) as an alternative that avoids deprivation while yielding stable motivation for thousands of trials. Using licking or lever press as a report, MFB animals learnt auditory discrimination tasks at similar speed to water-deprived mice. Moreover, they more reliably reached higher accuracy in harder tasks, performing up to 4,500 trials per session without loss of motivation. MFB stimulation did not impact the underlying sensory behavior since psychometric parameters and response times are preserved. MFB mice lacked signs of metabolic or behavioral stress compared with water-deprived mice. Overall, MFB stimulation is a highly promising tool for task learning because it enhances task performance while avoiding deprivation.

Frontiers in Human Neuroscience · Nov 2022

Neural responses to naturalistic audiovisual speech are related to listening demand in cochlear implant users (opens in a new tab)

Bowen Xiu, Brandon T. Paul, Joseph M. Chen, … Andrew Dimitrijevic

Abstract

There is a weak relationship between clinical and self-reported speech perception outcomes in cochlear implant (CI) listeners. Such poor correspondence may be due to differences in clinical and “real-world” listening environments and stimuli. Speech in the real world is often accompanied by visual cues, background environmental noise, and is generally in a conversational context, all factors that could affect listening demand. Thus, our objectives were to determine if brain responses to naturalistic speech could index speech perception and listening demand in CI users. Accordingly, we recorded high-density electroencephalogram (EEG) while CI users listened/watched a naturalistic stimulus (i.e., the television show, “The Office”). We used continuous EEG to quantify “speech neural tracking” (i.e., TRFs, temporal response functions) to the show’s soundtrack and 8–12 Hz (alpha) brain rhythms commonly related to listening effort. Background noise at three different signal-to-noise ratios (SNRs), +5, +10, and +15 dB were presented to vary the difficulty of following the television show, mimicking a natural noisy environment. The task also included an audio-only (no video) condition. After each condition, participants subjectively rated listening demand and the degree of words and conversations they felt they understood. Fifteen CI users reported progressively higher degrees of listening demand and less words and conversation with increasing background noise. Listening demand and conversation understanding in the audio-only condition was comparable to that of the highest noise condition (+5 dB). Increasing background noise affected speech neural tracking at a group level, in addition to eliciting strong individual differences. Mixed effect modeling showed that listening demand and conversation understanding were correlated to early cortical speech tracking, such that high demand and low conversation understanding occurred with lower amplitude TRFs. In the high noise condition, greater listening demand was negatively correlated to parietal alpha power, where higher demand was related to lower alpha power. No significant correlations were observed between TRF/alpha and clinical speech perception scores. These results are similar to previous findings showing little relationship between clinical speech perception and quality-of-life in CI users. However, physiological responses to complex natural speech may provide an objective measure of aspects of quality-of-life measures like self-perceived listening demand.

Brain Sciences · Oct 2022

Selective Neural Electrical Stimulation of an Injured Facial Nerve Using Chronically Implanted Dual Cuff Electrodes (opens in a new tab)

Arash Abiri, Steven Chau, Nathan R. James, … Harrison W. Lin

Abstract

Facial nerve (FN) injury can lead to debilitating and permanent facial paresis/paralysis (FP), where facial muscles progressively lose tone, atrophy, and ultimately reduce to scar tissue. Despite considerable efforts in the recent decades, therapies for FP still possess high failure rates and provide inadequate recovery of muscle function. In this pilot study, we used a feline model to demonstrate the potential for chronically implanted multichannel dual-cuff electrodes (MCE) to selectively stimulate injured facial nerves at low current intensities to avoid stimulus-induced neural injury. Selective facial muscle activation was achieved over six months after FN injury and MCE implantation in two domestic shorthaired cats (Felis catus). Through utilization of bipolar stimulation, specific muscles were activated at significantly lower electrical currents than was achievable with single channel stimulation. Moreover, interval increases in subthreshold current intensities using bipolar stimulation enabled a graded EMG voltage response while maintaining muscle selectivity. Histological examination of neural tissue at implant sites showed no appreciable signs of stimulation-induced nerve injury. Thus, by selectively activating facial musculature six months following initial FN injury and MCE implantation, we demonstrated the potential for our neural stimulator system to be safely and effectively applied to the chronic setting, with implications for FP treatment.

Clinical Neurophysiology · Oct 2022

Microscale electrophysiological functional connectivity in human cortico-basal ganglia network (opens in a new tab)

Ashley C Guest, Kevin J O'Neill, Dakota Graham, … Bradley Greger

Abstract

Objective: We investigated the electrophysiological relationships in the cortico-basal ganglia network on a sub-centimeter scale to increase our understanding of neural functional relationships in Parkinson's disease (PD). Methods: Data was intraoperatively recorded from 2 sources in the human brain-a microelectrode in the subthalamic nucleus (STN) and a micro-electrocorticography grid on the motor association cortex-during bilateral deep brain stimulation (DBS) electrode placement. STN neurons and local field potential (LFP) were defined as functionally connected when the 99.7% confidence intervals of the action potential (AP)-aligned average LFP and control did not overlap. Results: APs from STN neurons were functionally connected to the STN LFP for 18/46 STN neurons. This functional connection was observed between STN neuron APs and cortical LFP for 25/46 STN neurons. The cortical patterns of electrophysiological functional connectivity differed for each neuron. Conclusions: A subset of single neurons in the STN exhibited functional connectivity with electrophysiological activity in the STN and at a distance with the motor association cortex surveyed on a sub-centimeter spatial scale. These connections show a per neuron differential topography on the cortex. Significance: The cortico-basal ganglia circuit is organized on a sub-centimeter scale, and plays an important role in the mechanisms of PD and DBS.