TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

467 papers

IEEE Transactions on Neural Systems and Rehabilitation Engineering · Oct 2019

A Robust Encoding Scheme for Delivering Artificial Sensory Information via Direct Brain Stimulation (opens in a new tab)

David A. Bjanes, Chet T. Moritz

Abstract

Innovations for creating somatosensation via direct electrical stimulation of the brain will be required for the next generation of bi-directional cortical neuroprostheses. The current lack of tactile perception and proprioceptive input likely imposes a fundamental limit on speed and accuracy of brain-controlled prostheses or re-animated limbs. This study addresses the unique challenge of identifying a robust, high bandwidth sensory encoding scheme in a high-dimensional parameter space. Previous studies demonstrated single dimensional encoding schemes delivering low bandwidth sensory information, but no comparison has been performed across parameters, nor with update rates suitable for real-time operation of a neuroprosthesis. Here, we report the first comprehensive measurement of the resolution of key stimulation parameters such as pulse amplitude, pulse width, frequency, train interval and number of pulses. Surprisingly, modulation of stimulation frequency was largely undetectable. While we initially expected high frequency content to be an ideal candidate for passing high throughput sensory signals to the brain, we found only modulation of very low frequencies were detectable. Instead, the charge-per-phase of each pulse yields the highest resolution sensory signal, and is the key parameter modulating perceived intensity. The stimulation encoding patterns were designed for high-bandwidth information transfer that will be required for bi-directional brain interfaces. Our discovery of the stimulation features which best encode perceived intensity have significant implications for design of any neural interface seeking to convey information directly to the brain via electrical stimulation.

Biosensors and Bioelectronics · Oct 2019

Flexible, multichannel cuff electrode for selective electrical stimulation of the mouse trigeminal nerve (opens in a new tab)

Jihye Bong, Jared P. Ness, Weifeng Zeng, … Aaron J. Suminski

Abstract

The trigeminal nerve (cranial nerve V), along with other cranial nerves, has in recent years become a popular target for bioelectric medicine due to its direct access to neuromodulatory centers. Trigeminal nerve stimulation is currently being evaluated as an adjunctive treatment for various neurodegenerative and neuropsychiatric diseases despite the mechanism of action being in question. In this work, we describe the development and validation of a novel neural interface for the infraorbital branch of the trigeminal nerve utilizing a thin film (TF) nerve cuff containing multiple electrode sites allowing for more selective stimulation of the nerve. We characterized the properties of the device using electrochemical impedance spectroscopy, cyclic voltammetry, voltage excursions, and in vivo testing. Electrochemical measurements demonstrate that the platinum-based electrodes possess a capacitive charge carrying mechanism suitable for stimulation of biological tissue with a safe charge injection limit of 73.13 μC/cm2. In vivo stimulation experiments show that the TF cuff can reliably stimulate nerve targets eliciting cortical responses similar to a silicone cuff electrode. Furthermore, selecting different pairs of stimulation electrodes on the TF cuff modulated the magnitude and/or spatial pattern of cortical responses suggesting that the device may be able to selectively stimulate different parts of the nerve. These results suggest that the TF cuff is a viable neural interface for stimulation of the infraorbital branch of the trigeminal nerve that enables future research examining the therapeutic mechanisms of trigeminal nerve stimulation.

Advanced Healthcare Materials · Sep 2019

Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation (opens in a new tab)

Stefano Carli, Michele Bianchi, Elena Zucchini, … Fabio Biscarini

Abstract

Microelectrode arrays are used for recording and stimulation in neurosciences both in vitro and in vivo. The electrodeposition of conductive polymers, such as poly(3,4‐ethylene dioxythiophene) (PEDOT), is widely adopted to improve both the in vivo recording and the charge injection limit of metallic microelectrodes. The workhorse of conductive polymers in the neurosciences is PEDOT:PSS, where PSS represents polystyrene‐sulfonate. In this paper, the counterion is the fluorinated polymer Nafion, so the composite PEDOT:Nafion is deposited onto a flexible neural microelectrode array. PEDOT:Nafion coated electrodes exhibit comparable in vivo recording capability to the reference PEDOT:PSS, providing a large signal‐to‐noise ratio in a murine animal model. Importantly, PEDOT:Nafion exhibits a minimized polarization during electrical stimulation, thereby resulting in an improved charge injection limit equal to 4.4 mC cm −2 , almost 80% larger than the 2.5 mC cm −2 that is observed for PEDOT:PSS.

Nature Biomedical Engineering · Aug 2019

Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve (opens in a new tab)

Gaillet V, Cutrone A, Artoni F, … Ghezzi D

Abstract

Retinal prostheses can restore a functional form of vision in patients affected by dystrophies of the outer retinal layer. Beyond clinical utility, prostheses for the stimulation of the optic nerve, the visual thalamus or the visual cortex could also serve as tools for studying the visual system. Optic-nerve stimulation is particularly promising because it directly activates nerve fibres, takes advantage of the high-level information processing occurring downstream in the visual pathway, does not require optical transparency and could be effective in cases of eye trauma. Here we show, in anaesthetized rabbits and with support from numerical modelling, that an intraneural electrode array with high mechanical stability placed in the intracranial segment of the optic nerve induces, on electrical stimulation, selective activation patterns in the visual cortex. These patterns are measured as electrically evoked cortical potentials via an ECoG array placed in the contralateral cortex. The intraneural electrode array should enable further investigations of the effects of electrical stimulation in the visual system and could be further developed as a visual prosthesis for blind patients.

bioRxiv* · Aug 2019

Is Vagus Nerve Stimulation Brain Washing? (opens in a new tab)

Kevin P. Cheng, Sarah K. Brodnick, Stephan L. Blanz, … Kip A. Ludwig

Abstract

Vagal nerve stimulation (VNS) is an FDA approved treatment method for intractable epilepsy, treatment resistant depression, cluster headaches and migraine with over 100,000 patients having received vagal nerve implants to date. Moreover, evidence in the literature has led to a growing list of possible clinical indications, with several small clinical trials applying VNS to treat conditions ranging from neurodegenerative diseases to arthritis, anxiety disorders, and obesity. Despite the growing list of therapeutic applications, the fundamental mechanisms by which VNS achieves its beneficial effects are poorly understood and an area of active research. In parallel, the glymphatic and meningeal lymphatic systems have recently been proposed and experimentally validated to explain how the brain maintains a healthy homeostasis without a traditionally defined lymphatic system. In particular, the glymphatic system relates to the interchange of cerebrospinal fluid (CSF) and interstitial fluid (ISF) whose net effect is to wash through the brain parenchyma removing metabolic waste products and misfolded proteins from the interstitium. Of note, clearance is sensitive to adrenergic signaling, and a primary driver of CSF influx into the parenchyma appears to be cerebral arterial pulsations and respiration. As VNS has well-documented effects on cardiovascular and respiratory physiology as well as brain adrenergic signaling, we hypothesized that VNS delivered at clinically derived parameters would increase CSF influx in the brain. To test this hypothesis, we injected a low molecular weight (3 kD) lysine-fixable fluorescent tracer (TxRed) into the CSF system of mice with a cervical vagus nerve cuff implant and measured the amount of CSF penetrance following VNS. We found that the clinical VNS group showed a significant increase in CSF dye penetrance as compared to the naïve control and sham groups. This study demonstrates that VNS therapeutic strategies already being applied in the clinic today may induce intended effects and/or unwanted side effects by altering CSF/ISF exchange in the brain. This may have broad ranging implications in the treatment of various CNS pathologies. One Sentence Summary Cervical vagus nerve stimulation using clinically derived parameters enhances movement of cerebrospinal fluid into the brain parenchyma presenting a previously unreported effect of vagus nerve stimulation with potential clinical utility.

Journal of Neurophysiology · Aug 2019

Pairing vagus nerve stimulation with tones drives plasticity across the auditory pathway (opens in a new tab)

Michael S. Borland, Will A. Vrana, Nicole A. Moreno, … Crystal T. Engineer

Abstract

Previous studies have demonstrated that pairing vagus nerve stimulation (VNS) with sounds can enhance the primary auditory cortex (A1) response to the paired sound. The neural response to sounds following VNS-sound pairing in other subcortical and cortical auditory fields has not been documented. We predicted that VNS-tone pairing would increase neural responses to the paired tone frequency across the auditory pathway. In this study, we paired VNS with the presentation of a 9-kHz tone 300 times a day for 20 days. We recorded neural responses to tones from 2,950 sites in the inferior colliculus (IC), A1, anterior auditory field (AAF), and posterior auditory field (PAF) 24 h after the last pairing session in anesthetized rats. We found that VNS-tone pairing increased the percentage of IC, A1, AAF, and PAF that responds to the paired tone frequency. Across all tested auditory fields, the response strength to tones was strengthened in VNS-tone paired rats compared with control rats. VNS-tone pairing reduced spontaneous activity, frequency selectivity, and response threshold across the auditory pathway. This is the first study to document both cortical and subcortical plasticity following VNS-sound pairing. Our findings suggest that VNS paired with sound presentation is an effective method to enhance auditory processing. NEW & NOTEWORTHY Previous studies have reported primary auditory cortex plasticity following vagus nerve stimulation (VNS) paired with a sound. This study extends previous findings by documenting that fields across the auditory pathway are altered by VNS-tone pairing. VNS-tone pairing increases the percentage of each field that responds to the paired tone frequency. This is the first study to document both cortical and subcortical plasticity following VNS-sound pairing.

The Journal of the Acoustical Society of America · Aug 2019

Effect of channel separation and interaural mismatch on fusion and lateralization in normal-hearing and cochlear-implant listeners (opens in a new tab)

Alan Kan, Matthew J. Goupell, Ruth Y. Litovsky

Abstract

Bilateral cochlear implantation has provided access to some of the benefits of binaural hearing enjoyed by normal-hearing (NH) listeners. However, a gap in performance still exists between the two populations. Single-channel stimulation studies have shown that interaural place-of-stimulation mismatch (IPM) due to differences in implantation depth leads to decreased binaural fusion and lateralization of interaural time and level differences (ITDs and ILDs, respectively). While single-channel studies are informative, multi-channel stimulation is needed for good speech understanding with cochlear implants (CIs). Some multi-channel studies have shown that channel interaction due to current spread can affect ITD sensitivity. In this work, we studied the effect of IPM and channel spacing, along with their potential interaction, on binaural fusion and ITD/ILD lateralization. Experiments were conducted in adult NH listeners and CI listeners with a history of acoustic hearing. Results showed that IPM reduced the range of lateralization for ITDs but not ILDs. CI listeners were more likely to report a fused percept in the presence of IPM with multi-channel stimulation than NH listeners. However, no effect of channel spacing was found. These results suggest that IPM should be accounted for in clinical mapping practices in order to maximize bilateral CI benefits.

2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2019

Cortical Stimulation Induces Network-Wide Coherence Change In Non-Human Primate Somatosensory Cortex (opens in a new tab)

Julien A. Bloch, Karam Khateeb, Daniel B. Silversmith, … Azadeh Yazdan-Shahmorad

Abstract

Stimulation of the cortex can modulate the connectivity between brain regions. Although targeted neuroplasticity has been demonstrated in-vitro, in-vivo models have been inconsistent in their response to stimulation. In this paper, we tested various stimulation protocols to characterize the effect of stimulation on coherence in the non-human primate cortex in-vivo. We found that the stimulation latency, the state of the cortex during stimulation, and the stimulation site all affected the modulation of cortical coherence. We further investigated features of a resting-state network that could predict how a connection is likely to change with stimulation.

2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2019

Targeted Vagus Nerve Stimulation does not Disrupt Cardiac Function in the Diabetic Rat (opens in a new tab)

Elliott W. Dirr, Yogi A. Patel, Lauren Lester, … Kevin J. Otto

Abstract

In this study, we acutely identified a target branch of the vagus nerve known as the pancreatic branch of the vagus nerve, which exclusively innervates the pancreas by applying electrical stimulus to the known cervical vagus nerve and observing compound neural action potentials at the target nerve. In a set of chronically implanted rats, the target nerve was again cuffed using an electrode and also implanted with a continuous glucose monitor. A model of type 1 diabetes (T1D) was chemically induced and hyperglycemic state confirmed. After induction, stimulation was applied to the pancreatic branch of the vagus nerve and heart rate variability measured to assess the targeted nature of the stimulation. Pancreatic vagus nerve stimulation in a diabetic model was not found to influence heart rate demonstrating the ability of targeted stimulation to be used as for organ-specific neuromodulation while minimizing side effects.

Journal of the Association for Research in Otolaryngology · Jun 2019

Rapamycin Protects Spiral Ganglion Neurons from Gentamicin-Induced Degeneration In Vitro (opens in a new tab)

Shasha Guo, Nana Xu, Peng Chen, … Jie Tang

Abstract

Gentamicin, one of the most widely used aminoglycoside antibiotics, is known to have toxic effects on the inner ear. Taken up by cochlear hair cells and spiral ganglion neurons (SGNs), gentamicin induces the accumulation of reactive oxygen species (ROS) and initiates apoptosis or programmed cell death, resulting in a permanent and irreversible hearing loss. Since the survival of SGNs is specially required for cochlear implant, new procedures that prevent SGN cell loss are crucial to the success of cochlear implantation. ROS modulates the activity of the mammalian target of rapamycin (mTOR) signaling pathway, which mediates apoptosis or autophagy in cells of different organs. However, whether mTOR signaling plays an essential role in the inner ear and whether it is involved in the ototoxic side effects of gentamicin remain unclear. In the present study, we found that gentamicin induced apoptosis and cell loss of SGNs in vivo and significantly decreased the density of SGN and outgrowth of neurites in cultured SGN explants. The phosphorylation levels of ribosomal S6 kinase and elongation factor 4E binding protein 1, two critical kinases in the mTOR complex 1 (mTORC1) signaling pathway, were modulated by gentamicin application in the cochlea. Meanwhile, rapamycin, a specific inhibitor of mTORC1, was co-applied with gentamicin to verify the role of mTOR signaling. We observed that the density of SGN and outgrowth of neurites were significantly increased by rapamycin treatment. Our finding suggests that mTORC1 is hyperactivated in the gentamicin-induced degeneration of SGNs, and rapamycin promoted SGN survival and outgrowth of neurites.

IEEE Transactions on Neural Systems and Rehabilitation Engineering · Apr 2019

Real-time performance of a tactile neuroprosthesis on awake behaving rats (opens in a new tab)

Ozturk S, Devecioglu I, Beygi M, … Guclu B

Abstract

With the advancement of electrode and equipment technology, neuroprosthetics have become a promising alternative to partially compensate for the loss of sensorimotor function in amputees and patients with neurological diseases. Cortical neural interfaces are suitable especially for spinal cord injuries and amyotrophic lateral sclerosis. Although considerable success has been achieved in the literature by spike decoding of motor signals from the human brain, somatosensory feedback is essential for better motor control, interaction with objects, and the embodiment of prosthetic devices. In this paper, we present a tactile neuroprosthesis for rats based on intracortical microstimulation (ICMS). The rats wore mechanically-isolated boots covered with tactile sensors while performing a psychophysical detection task. The vibrotactile stimuli were measured by the artificial sensors and by using a real-time processor, this information was converted to electrical current pulses for ICMS. Some parameters of the real-time processor algorithm were specific to individual rats and were based on psychometric equivalence functions established earlier. Rats could detect the effects of the vibrotactile stimuli better (i.e., higher sensitivity indices) when the tactile neuroprosthesis was switched on compared to the boot only condition during active movement. In other words, the rats could decode the tactile information embedded in ICMS and use that in a behaviorally relevant manner. The presented animal model without peripheral nerve injury or amputation is also a promising tool to test various hardware and software components of neuroprosthetic systems in general.

The Journal of the Acoustical Society of America · Apr 2019

Auditory motion tracking ability of adults with normal hearing and with bilateral cochlear implants (opens in a new tab)

Keng Moua, Alan Kan, Heath G. Jones, … Ruth Y. Litovsky

Abstract

Adults with bilateral cochlear implants (BiCIs) receive benefits in localizing stationary sounds when listening with two implants compared with one; however, sound localization ability is significantly poorer when compared to normal hearing (NH) listeners. Little is known about localizing sound sources in motion, which occurs in typical everyday listening situations. The authors considered the possibility that sound motion may improve sound localization in BiCI users by providing multiple places of information. Alternatively, the ability to compare multiple spatial locations may be compromised in BiCI users due to degradation of binaural cues, and thus result in poorer performance relative to NH adults. In this study, the authors assessed listeners' abilities to distinguish between sounds that appear to be moving vs stationary, and track the angular range and direction of moving sounds. Stimuli were bandpass-filtered (150–6000 Hz) noise bursts of different durations, panned over an array of loudspeakers. Overall, the results showed that BiCI users were poorer than NH adults in (i) distinguishing between a moving vs stationary sound, (ii) correctly identifying the direction of movement, and (iii) tracking the range of movement. These findings suggest that conventional cochlear implant processors are not able to fully provide the cues necessary for perceiving auditory motion correctly.

Molecular Therapy · Mar 2019

Targeted Allele Suppression Prevents Progressive Hearing Loss in the Mature Murine Model of Human TMC1 Deafness (opens in a new tab)

Hidekane Yoshimura, Seiji B. Shibata, Paul T. Ranum, … Richard J.H. Smith

Abstract

Hearing loss is the most common human sensory deficit. Its correction has been the goal of several gene-therapy based studies exploring a variety of interventions. Although these studies report varying degrees of success, all treatments have targeted developing inner ears in neonatal mice, a time point in the structural maturation of the cochlea prior to 26 weeks gestational age in humans. It is unclear whether cochlear gene therapy can salvage hearing in the mature organ of Corti. Herein, we report the first study to test gene therapy in an adult murine model of human deafness. Using a single intracochlear injection of an artificial microRNA carried in an AAV vector, we show that RNAi-mediated gene silencing can slow progression of hearing loss, improve inner hair cell survival, and prevent stereocilia bundle degeneration in the mature Beethoven mouse, a model of human TMC1 deafness. The ability to study gene therapy in mature murine ears constitutes a significant step toward its translation to human subjects.

Scientific Reports · Mar 2019

Direct stimulation of somatosensory cortex results in slower reaction times compared to peripheral touch in humans (opens in a new tab)

David J. Caldwell, Jeneva A. Cronin, Jing Wu, … Jeffrey G. Ojemann

Abstract

Direct cortical stimulation (DCS) of primary somatosensory cortex (S1) could help restore sensation and provide task-relevant feedback in a neuroprosthesis. However, the psychophysics of S1 DCS is poorly studied, including any comparison to cutaneous haptic stimulation. We compare the response times to DCS of human hand somatosensory cortex through electrocorticographic grids with response times to haptic stimuli delivered to the hand in four subjects. We found that subjects respond significantly slower to S1 DCS than to natural, haptic stimuli for a range of DCS train durations. Median response times for haptic stimulation varied from 198 ms to 313 ms, while median responses to reliably perceived DCS ranged from 254 ms for one subject, all the way to 528 ms for another. We discern no significant impact of learning or habituation through the analysis of blocked trials, and find no significant impact of cortical stimulation train duration on response times. Our results provide a realistic set of expectations for latencies with somatosensory DCS feedback for future neuroprosthetic applications and motivate the study of neural mechanisms underlying human perception of somatosensation via DCS.

Human Gene Therapy · 2019

Virally Mediated Overexpression of Glial-Derived Neurotrophic Factor Elicits Age- and Dose-Dependent Neuronal Toxicity and Hearing Loss (opens in a new tab)

Omar Akil, Bas Blits, Lawrence R. Lustig, Patricia A. Leake

Abstract

Contemporary cochlear implants (CI) are generally very effective for remediation of severe to profound sensorineural hearing loss, but outcomes are still highly variable. Auditory nerve survival is likely one of the major factors underlying this variability. Neurotrophin therapy therefore has been proposed for CI recipients, with the goal of improving outcomes by promoting improved survival of cochlear spiral ganglion neurons (SGN) and/or residual hair cells. Previous studies have shown that glial-derived neurotrophic factor (GDNF), brain-derived neurotrophic factor, and neurotrophin-3 can rescue SGNs following insult. The current study was designed to determine whether adeno-associated virus vector serotype 5 (AAV-5) encoding either green fluorescent protein or GDNF can transduce cells in the mouse cochlea to express useful levels of neurotrophin and to approximate the optimum therapeutic dose(s) for transducing hair cells and SGN. The findings demonstrate that AAV-5 is a potentially useful gene therapy vector for the cochlea, resulting in extremely high levels of transgene expression in the cochlear inner hair cells and SGN. However, overexpression of human GDNF in newborn mice caused severe neurological symptoms and hearing loss, likely due to Purkinje cell loss and cochlear nucleus pathology. Thus, extremely high levels of transgene protein expression should be avoided, particularly for proteins that have neurological function in neonatal subjects.

The Journal of the Acoustical Society of America · 2019

Tympanic membrane surface motions in forward and reverse middle ear transmissions (opens in a new tab)

Jeffrey Tao Cheng, Nima Maftoon, Jérémie Guignard, … John Rosowski

Abstract

Characterization of Tympanic Membrane (TM) surface motions with forward and reverse stimulation is important to understanding how the TM transduces acoustical and mechanical energy in both directions. In this paper, stroboscopic opto-electronic holography is used to quantify motions of the entire TM surface induced by forward sound and reverse mechanical stimulation in human cadaveric ears from 0.25 to 18.4 kHz. The forward sound stimulus was coupled to an anatomically realistic artificial ear canal that allowed optical access to the entire TM surface, and the reverse mechanical stimulus was applied to the body of the incus by a piezo-electric stimulator. The results show clear differences in TM surface motions evoked by the two stimuli. In the forward case, TM motion is dominated by standing-wave-like modal motions that are consistent with a relatively uniform sound-pressure load over the entire TM surface. With reverse mechanical stimulation, the TM surface shows more traveling waves, consistent with a localized mechanical drive applied to the manubrium embedded in the TM. With both stimuli, the manubrium moves less than the rest of the TM, consistent with the TM acting like a compliant membrane rather than a stiff diaphragm, and also consistent with catenary behavior due to the TM's curved shape.

Journal of Neuroscience Research · Dec 2018

Calcium activation of cortical neurons by continuous electrical stimulation: Frequency dependence, temporal fidelity, and activation density (opens in a new tab)

Nicholas J. Michelson, James R. Eles, Alberto L. Vazquez, … Takashi D. Y. Kozai

Abstract

Electrical stimulation of the brain has become a mainstay of fundamental neuroscience research and an increasingly prevalent clinical therapy. Despite decades of use in basic neuroscience research and the growing prevalence of neuromodulation therapies, gaps in knowledge regarding activation or inactivation of neural elements over time have limited its ability to adequately interpret evoked downstream responses or fine‐tune stimulation parameters to focus on desired responses. In this work, in vivo two‐photon microscopy was used to image neuronal calcium activity in layer 2/3 neurons of somatosensory cortex (S1) in male C57BL/6J‐Tg(Thy1‐GCaMP6s)GP4.3Dkim/J mice during 30 s of continuous electrical stimulation at varying frequencies. We show frequency–dependent differences in spatial and temporal somatic responses during continuous stimulation. Our results elucidate conflicting results from prior studies reporting either dense spherical activation of somas biased toward those near the electrode, or sparse activation of somas at a distance via axons near the electrode. These findings indicate that the neural element specific temporal response local to the stimulating electrode changes as a function of applied charge density and frequency. These temporal responses need to be considered to properly interpret downstream circuit responses or determining mechanisms of action in basic science experiments or clinical therapeutic applications.

Magnetic Resonance in Medicine · Nov 2018

Evaluation of magnetohydrodynamic effects in magnetic resonance electrical impedance tomography at ultra-high magnetic fields (opens in a new tab)

Atul S. Minhas, Munish Chauhan, Fanrui Fu, Rosalind Sadleir

Abstract

Purpose Artifacts observed in experimental magnetic resonance electrical impedance tomography images were hypothesized to be because of magnetohydrodynamic (MHD) effects. Theory and Methods Simulations of MREIT acquisition in the presence of MHD and electrical current flow were performed to confirm findings. Laminar flow and (electrostatic) electrical conduction equations were bidirectionally coupled via Lorentz force equations, and finite element simulations were performed to predict flow velocity as a function of time. Gradient sequences used in spin‐echo and gradient echo acquisitions were used to calculate overall effects on MR phase images for different electrical current application or phase‐encoding directions. Results Calculated and experimental phase images agreed relatively well, both qualitatively and quantitatively, with some exceptions. Refocusing pulses in spin echo sequences did not appear to affect experimental phase images. Conclusion MHD effects were confirmed as the cause of observed experimental phase changes in MREIT images obtained at high fields. These findings may have implications for quantitative measurement of viscosity using MRI techniques. Methods developed here may be also important in studies of safety and in vivo artifacts observed in high field MRI systems.

* Preprint: not yet peer reviewed.