TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

Hearing Research · Feb 1995

Nonlinear mechanics at the apex of the guinea-pig cochlea (opens in a new tab)

Cooper NP, Rhode WS

Abstract

A heterodyne laser interferometer was used to observe the sound-evoked displacement patterns of Reissner's membrane and various other structures in the apical turn of the guinea-pig cochlea. Most structures (including the basilar membrane) were similarly tuned, and had best frequencies in the 200-350Hz range. A distinct notch was usually observed approximately 0.7 octaves above the best frequency, and amplitude- and phase-plateaus were observed at higher frequencies. In most other respects, however, the mechanical tuning resembled the frequency-threshold curves of low frequency cochlear nerve fibers. In five reasonably intact, in vivo preparations, the frequency of the mechanical sensitivity notch was intensity-dependent: Compressive nonlinearities were observed above approximately 80 dB SPL on the low-frequency side of the notch, with antagonistically expansive nonlinearities on the high-frequency side. Two-tone suppression was observed in one of these preparations. Stimulus-related baseline position shifts were observed in another in vivo preparation. No such nonlinearities were observed in structurally damaged and/or > 1 hour post-mortem preparations. However, more robust nonlinearities were observed in all preparations at higher levels of stimulation (e.g. > 100-110 dB SPL). These high-level nonlinearities diminished only slowly after death, and gave rise to various effects, including time-dependent (i.e. adapting) and severely distorted (e.g. peak-split and/or dc-shifted) responses.

Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 1995

Auditory icons as warning and advisory signals in the US Army Battlefield Combat Identification System (BCIS) (opens in a new tab)

Ellen Haas, Jeffrey Schmidt

Abstract

The U.S. Army proposed the Battlefield Combat Identification System (BCIS) to diminish fratricide by providing five critical auditory and visual warning signals. The purpose of this experiment was to determine whether the auditory warning signals designed by the U.S. Army Human Research and Engineering Directorate (HRED) provided greater user association with the BCIS signal functions than did signals designed by a contractor. The contractor signals consisted of pure tones, while the HRED signals were auditory icons designed with intent to provide a high level of user association. The dependent variable was the subject's free-modulus magnitude estimation rating of the degree of association of the signal with the signal function. Subjects were 20 male U.S. Army Infantrymen. Data were analyzed using t-tests for paired samples. Results indicated that the mean perceived association was significantly greater for the HRED auditory icons in one of five cases, and greater (but not significantly so) in two additional cases. There were no other significant differences. Implications for auditory display design are discussed.

Hearing Research · Dec 1994

Behavioral and electrophysiological responses to electrical stimulation in the cat: I. Absolute thresholds (opens in a new tab)

Smith DW, Finley CC, van den Honert C, … Konrad KE

Abstract

Estimates of electrical auditory brainstem response (EABR) thresholds are compared with behavioral thresholds for electrical stimulation in the same subject using identical stimuli and electrode configurations. Four cats were behaviorally trained to measure acoustic auditory thresholds using food as a reward in an operant reinforcement paradigm. One of the animals was then implanted, in an otherwise normal ear, with a scaled-UCSF multi-contact electrode array containing four intracochlear electrodes. Three animals were implanted with an electrode array containing eight intracochlear contacts and one extracochlear contact under the temporalis muscle following unilateral cochlear perfusion with 10% neomycin solution. Stimuli for the behavioral studies were single presentations of 200 us/phase biphasic current pulses. For the EABR studies, the same stimulus was presented at a rate of 32/s. In general, for the animal with the four-contact array and two of the three subjects with the eight-contact implant, changes in electrode configuration produced well-differentiated changes in threshold. For these three subjects, comparisons of behavioral and EABR thresholds for the majority of monopolar and bipolar electrode configurations tested showed excellent agreement (r2 = 0.88). Correlations between behavioral and EABR measures in these animals were comparable for bipolar and monopolar arrangements (r2 = 0.88 for bipolar and 0.87 for monopolar). For one subject with the eight-contact electrode, who showed similar monopolar and bipolar electrode behavioral thresholds for all tested electrode spacings or configurations, most EABR thresholds were substantially higher than, and poorly correlated with, behavioral thresholds (r2 = 0.15; r2 = 0.28 for monopolar arrangements, and r2 = 0.12 for bipolar arrangements).

Ear & Hearing · Dec 1994

Simultaneous measurement of tinnitus pitch and loudness (opens in a new tab)

Penner MJ, Saran A

Abstract

Objective Simultaneous measures of the frequency and level of a pure tone matching the predominant pitch and loudness of tinnitus were obtained using four interleaved staircases. Design Two staircases in a forced-choice procedure tracked two frequencies, one higher and one lower than the predominant pitch of the tinnitus, while two staircases tracked two levels, one louder and one softer than the tinnitus. Results The standard deviation of the pitch matches to tinnitus using the forced-choice procedure with four staircases (4SFC) exceeded that from a double staircase (2SFC) task in which the level of the matching tone was fixed, whereas the 2SFC and 4SFC tasks had similar SDs for loudness matches to tinnitus when the frequency of the matching tone was fixed and for matches to the pitch or loudness of external tones. As the level of the tone matching the tinnitus pitch in the 4SFC task increased relative to that of the 2SFC task, so did its frequency. Conclusion These data may be interpreted as indicating that tinnitus is a fluctuant signal, and that matches of pure tones to tinnitus are not single-valued.

The Journal of the Acoustical Society of America · Oct 1994

Amplitude modulation rate discrimination with sinusoidal carriers (opens in a new tab)

Lee J

Abstract

Discrimination of the change in rate of sinusoidal amplitude modulation was investigated for sinusoidal carriers. The just-noticeable change in the modulation rate was measured as a function of (1) carrier frequency (fc = 500, 1000, 2000, or 4000 Hz), (2) initial modulation rate (fm = 10, 20, 40, 80, 160, or 320 Hz), and (3) stimulus duration (T = 62, 125, 250, 500, 1000, or 2000 ms). For modulation rates less than 320 Hz, the thresholds for a change in modulation rate were not affected by changing the carrier frequency. When fm = 320 Hz, the threshold for changes in the modulation rate ordered in the same way as the threshold for changes in the frequency of a pure tone, suggesting that the primary cue for discriminating a change in modulation rate was the frequency of either sideband. As stimulus duration increased to a certain T (critical duration), the thresholds decreased by more than a factor of 2. Above that duration, the thresholds for changes in modulation rate decreased only slightly or remained constant. The critical duration corresponded to about five cycles of modulation, at least for the slower modulation rates.

The Journal of the Acoustical Society of America · Oct 1994

Loudness growth in forward masking: Relation to intensity discrimination (opens in a new tab)

Zeng FG

Abstract

The growth of loudness of a tone burst following an intense forward masker was measured as a function of the tone level. The level of the forward-masked tone was adjusted to balance the loudness of a standard tone presented without a forward masker, using a 2AFC, double-staircase, tracking procedure. The forward masker was a 90-dB SPL, 100-ms, 1000-Hz pure tone. The standard tone and the masked tone were both 25-ms, 1000-Hz pure tones. The forward masker and the masked tone were always presented in the first interval. With a 100-ms delay between them, there was little or no threshold elevation for the masked tone. However, the masker caused the masked tone to sound louder than it would if it had not been masked, a phenomenon termed "loudness enhancement" [Irwin and Zwislocki, Percept. Psychophys. 10, 189-192 (1971); Galambos et al., J. Acoust. Soc. Am. 52, 1127-1130 (1972)]. In addition, the present results show a nonmonotonic enhancement function that the forward masker introduced a 10-16-dB enhancement effect for tones of 40-65 dB SPL and no significant effect for the 30 and 90 dB SPL tones. The loudness variability in forward masking was estimated from the upper and lower sequences tracking the 21% and the 79% louder response levels on the psychometric function, respectively. The variability demonstrated a similar nonmonotonic function. In forward masking loudness grows more steeply at low-medium sensation levels, and merges with normal growth at high levels.(ABSTRACT TRUNCATED AT 250 WORDS)

The Journal of the Acoustical Society of America · Sep 1994

The effects of signal frequency and absolute bandwidth on gap detection in noise (opens in a new tab)

Snell KB, Ison JR, Frisina DR

Abstract

Whether temporal resolution in noisebursts is primarily determined by the highest frequency component in the signal or its absolute bandwidth remains unclear. In this study, the absolute bandwidths and upper cutoff frequencies of signal noisebursts were varied across broad frequency ranges, several times greater than previously jointly studied. The purpose was to determine how each independently affects detection, taking into consideration that bandwidth effects at one signal frequency might be very different from bandwidth effects at another. Gap detection thresholds were obtained for five subjects with normal hearing in a 2 IFC paradigm. Signals were noisebursts whose bandwidths and upper cutoff frequencies varied among 1, 2, 4, 8, and 12 kHz. Their duration was 150 ms and they were presented at an overall level of 75 dB SPL above a 45 dB SPL white noise floor. The largest mean gap detection threshold, 6.98 ms, was obtained for a noiseburst with a bandwidth of 1 kHz and upper cutoff frequency of 12 kHz. The smallest mean gap detection threshold, 2.22 ms, was found with a bandwidth and upper cutoff frequency of 12 kHz. Significant interactions were found to exist between absolute bandwidth and upper cutoff frequency. Although gap detection thresholds generally decreased with increasing signal frequency and bandwidth, the pattern was complex. When the absolute bandwidth was at least one-half the upper cutoff frequency then upper cutoff frequency and not bandwidth determined gap sensitivity; but when the absolute bandwidth was less than one-half of the upper frequency, then both determined gap thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Hearing Research · Jun 1994

Perception of temporal acoustic patterns by the goldfish (Carassius auratus) (opens in a new tab)

Fay RR

Abstract

The perception of temporal acoustic patterns was studied in the goldfish using classical respiratory conditioning in combination with a stimulus generalization paradigm. Stimuli consisted of a bandpass filtered pulse repeated in various periodic and aperiodic temporal patterns. In each of 14 experiments, animals received 40 conditioning trials to a given stimulus pattern and were then tested for generalization to eight novel stimuli differing only in temporal pattern. In experiments 1-5, animals were conditioned to a periodic pulse train with a particular interpulse interval (IPI) and then tested to novel periodic pulse trains with various IPIs. Generalization gradients were substantially symmetric and monotonic with repetition rate, suggesting a perceptual continuum in goldfish that is similar to periodicity pitch or roughness in human listeners. Several additional experiments indicated that the perceptual qualities of simple and complex temporal patterns are not primarily determined by spectral structure or pulse rate, but rather are determined by the distribution of IPIs. A model for the central analysis of IPIs was successful in accounting for the results of experiments in which animals were conditioned to simple, periodic stimuli. However, the model failed when animals were conditioned to more complex stimuli having aperiodic temporal patterns. These experiments demonstrate the potential usefulness of the stimulus generalization paradigm for investigating aspects of complex sound source perception in non-human animals.

The Journal of the Acoustical Society of America · Jun 1994

The location‐dependent nature of perceptually salient features of the human head‐related transfer functions (opens in a new tab)

Carlille S, Pralong D

Abstract

The human head-related transfer function (HRTF) has been recorded binaurally from eight subjects using an "in-ear" recording system, for 343 stimulus locations around the head. There are a number of systematic changes in the HRTF as a function of horizontal location and elevation, on and off the median plane, that could be used as cues to sound location. To identify which components of the HRTF might provide perceptually salient cues to sound location, the HRTFs were transformed using an auditory filter model which accounts for the frequency dependence of auditory sensitivity and the frequency and level-dependent characteristics of the auditory filters. These transformations indicated a systematic variation in the frequency of the peak excitation as a function of the horizontal location of a broad band stimulus. Furthermore, there were differences in the frequency range over which elevation-dependent changes in the excitation patterns varied as a function of the vertical meridian. Interaural level differences were also estimated using the excitation patterns. The across frequency pattern of ILDs were roughly symmetrical about the interaural axis, although there were substantial differences between each ear in the magnitude of the ILDs generated for ipsilateral sounds locations.

The Journal of the Acoustical Society of America · Jun 1994

Measuring the human head‐related transfer functions: A novel method for the construction and calibration of a miniature ”in‐ear”recording system (opens in a new tab)

Pralong D, Carlile S

Abstract

A method for the construction of a small "in-ear" system for recording the human-free field-to-eardrum and headphone-to-eardrum transfer functions is described. Customized in-ear inserts were obtained by a simple ear printing and electroplating method, resulting in a thin (< 0.25 mm) outer shell that minimized obstruction of the entrance at the ear canal. The insert can be used to position a microphone probe tube deep within the auditory canal. The effects of this recording system on the sound field in the ear canal were calibrated using a model head equipped with a second internal microphone close to the eardrum. Transfer functions were recorded for 343 different stimulus locations in free space and for a headphone sound source. For the free-field stimuli the presence of the recording system resulted in a small attenuation with maximum effects around 3.5 and 12.5 kHz (-1.5 and -2.0 dB, respectively). Passing the data through an auditory filter model reduced the averaged attenuation to less than -1.4 dB. Phase was undistorted up to 2.5 kHz. These results suggests that the perturbations produced by the insert are unlikely to be perceptually relevant.

Hearing Research · May 1994

Monaural sound localization: acute versus chronic unilateral impairment (opens in a new tab)

Slattery WH 3rd, Middlebrooks JC

Abstract

We tested the ability of human listeners to localize broadband noise bursts in the absence of binaural localization cues. The subject population consisted of five patients, who had normal hearing in one ear and congenital deafness in the other, and seven normal controls, who were tested with both ears open and with one ear plugged. Consistent with previous reports, the introduction of an ear plug unilaterally into control subjects resulted in a prominent lateral displacement in their localization judgements by an average of 30.9 degrees toward the side of the open ear. Vertical localization was less strongly impaired. The five monaural patients showed a considerable range of ability to localize sounds. Two of the patients were essentially indistinguishable from the plugged control subjects in that they showed a prominent displacement of responses toward the side of the hearing ear. The other three subjects localized significantly better than the plugged controls, in that they demonstrated little or no lateral displacement toward the hearing side and that they localized targets on the hearing and on the impaired sides about equally well. The performance of these latter patients demonstrates that monaural cues can provide useful localization information in the horizontal as well as in the vertical dimension.

Otolaryngology · 1994

Covariation of tinnitus pitch and the associated emission: A case study (opens in a new tab)

Penner MJ, Glotzbach L

Abstract

Tinnitus in one female subject was found to be related to numerous (as many as 21) bilateral spontaneous otoacoustic emissions. The association of tinnitus and spontaneous otoacoustic emissions was empirically supported by the masking/suppression demonstration. The subject reported that her tinnitus occurred primarily in her right ear, which had linked, quasi-stable spontaneous otoacoustic emissions not found contralaterally. During one menstrual cycle, a pure tone was adjusted to match the predominant tinnitus pitch. The frequency of the tone generally followed the day-to-day shifts in the frequency of the associated spontaneous otoacoustic emission. The frequencies of these tones were a local minimum near the onset of menstruation, reaching a local maximum after menstruation.

Le Journal de Physique IV · 1994

Système efférent, masquage central et perception dans le bruit (opens in a new tab)

C. MICHEYL, L. COLLET

Abstract

In order to investigate the role of the auditory efferents in perception, the controlateral suppression of evoked otoacoustic emissions (EOAEs) was examined together with 1) central masking and 2) detection in noise in normal hearing subjects. The first study, concerning the relations between the contralateral suppression of EOAEs and central masking at 1 kHz, put into evidence the existence of a significant negative correlation between the amount of central masking obtained with a delay of 20 ms between the test and the mask and the modifications of the amplitude of EOAEs induced around 1 kHz by a contralateral 30 dBSL broadband noise stimulation. In the second study, a correlation was found between the mean equivalent attenuation of EOAEs and the variation of the tone-in-noise detection threshold, both induced by a contralateral 30 dBSL broadband noise stimulation. These results support the hypothesis that the crossed part of the medial olivo-cochlear system is actually involved in auditory perception in humans.

The Journal of the Acoustical Society of America · Nov 1992

Narrow‐band sound localization related to external ear acoustics (opens in a new tab)

Middlebrooks JC

Abstract

Human subjects localized brief 1/6-oct bandpassed noise bursts that were centered at 6, 8, 10, and 12 kHz. All testing was done under binaural conditions. The horizontal component of subjects' responses was accurate, comparable to that for broadband localization, but the vertical and front/back components exhibited systematic errors. Specifically, responses tended to cluster within restricted ranges that were specific for each center frequency. The directional transfer functions of the subjects' external ears were measured for 360 horizontal and vertical locations. The spectra of the sounds that were present in the subjects' ear canals, the "proximal stimulus" spectra, were computed by combining the spectra of the narrow-band sound sources with the directional transfer functions for particular stimulus locations. Subjects consistently localized sounds to regions within which the associated directional transfer function correlated most closely with the proximal stimulus spectrum. A quantitative model was constructed that successfully predicted subjects' responses based on interaural level difference and spectral cues. A test of the model, using techniques adapted from signal detection theory, indicated that subjects tend to use interaural level difference and spectral shape cues independently, limited only by a slight spatial correlation of the two cues. A testing procedure is described that provides a quantitative comparison of various predictive models of sound localization.

Hearing Research · 1992

Methods for detecting auditory steady-state potentials recorded from humans (opens in a new tab)

Craig A Champlin

PA3QDAIABR/DPOAE
Abstract

Auditory steady-state potentials were recorded from the scalp of adult humans. The stimuli were 100-microseconds clicks presented at a rate of 39.1/s. Four stimulus levels were used (-20, 0, 10, and 20 dB SL). The presence or absence of a response was determined by three frequency-domain methods and examiners. The frequency-domain methods were: magnitude-squared coherence (MSC), phase coherence (PC), and magnitude only (MO). The MSC method generally had the highest d' values, indicating that it was the most sensitive method for detecting responses. The hearing threshold predicted by the MSC method was the lowest, and it was within 4 dB of the behaviorally measured threshold for the click stimuli. Further, the amplitude of the response was significantly more variable than its phase, and no relation was found between the variability of the amplitude of the response and the amplitude of the noise. In summary, response detection methods that incorporate phase information (such as MSC and PC) should be chosen over methods which incorporate only amplitude information.