Hearing Research · Nov 1997

Diversity in frequency response properties of saccular afferents of the toadfish, Opsanus tau (opens in a new tab)

Fay RR, Edds-Walton PL

Abstract

The frequency response of primary saccular afferents of toadfish (Opsanus tau) was studied in the time and frequency domains using the reverse correlation (revcor) method. Stimuli were noise bands with flat acceleration spectra delivered as whole-body motion. The recorded acceleration waveform was averaged over epochs preceding and following each spike. This average, termed the revcor, is an estimate of the response of an equivalent linear filter intervening between body motion and spike initiation. The spectrum of the revcor estimates the shape of the equivalent linear filter. Revcor responses were brief, damped oscillations indicative of relatively broadly tuned filters. Filter shapes were generally band-pass and differed in bandwidth, band edge slope, and characteristic frequency (74 Hz to 140 Hz). Filter shapes tend to be independent of stimulus level. Afferents can be placed into two groups with respect to characteristic frequency (74-88 Hz and 140 Hz). Some high-frequency afferents share a secondary peak at the characteristic frequency of low-frequency afferents, suggesting that an afferent may receive differently tuned peripheral inputs. For some afferents having similar filter shapes, revcor responses often differ only in polarity, probably reflecting inputs from hair cells oriented in opposite directions. The origin of frequency selectivity and its diversity among saccular afferents may arise from a combination of hair cell resonance and micromechanical processes. The resulting frequency analysis is the simplest yet observed among vertebrate animals. During courtship, male toadfish produce the 'boatwhistle' call, a periodic vocalization having several harmonics of a 130 Hz fundamental frequency. The saccule encodes the waveform of acoustic particle acceleration between < 50 and about 250 Hz. Thus, the fundamental frequency component of the boatwhistle is well encoded, but the successive higher harmonics are filtered out. The boatwhistle is thus encoded as a time-domain representation of its fundamental frequency or pulse repetition rate.

The Journal of the Acoustical Society of America · Oct 1997

Identification of multidimensional stimuli containing speech cues and the effects of training (opens in a new tab)

Christensen LA, Humes LE

Abstract

The purpose of this study was to determine how listeners with normal hearing make use of cues from multiple, independent stimulus dimensions when classifying synthesized stimuli containing acoustic cues found in speech. Listeners classified synthesized stimuli that differed on three independent and discriminable dimensions. The three dimensions of the stimuli included: (1) the fricative spectrum center frequency; (2) the slope of the frequency transition; and (3) the duration of the temporal gap. Each of the three dimensions could take on one of three possible values. Twenty-seven stimuli were synthesized using all possible combinations of the values on the three dimensions. Multidimensional scaling of paired-comparison similarity judgments confirmed the existence of three perceptual dimensions. Listeners were then trained to classify three exemplar stimuli as "circle," "triangle," and "square," respectively. Following this training, subjects classified all 27 stimuli as "circle," "triangle," and "square." From this it was determined how each listener's attention was distributed among the dimensions. Results indicated the listeners did not pay equal attention to the three stimulus dimensions. In addition, it was demonstrated that it was possible to train a listener to attend to a dimension that was not previously used to classify the stimuli.

The Journal of the Acoustical Society of America · Oct 1997

Effects of electrode configuration on psychophysical strength-duration functions for single biphasic electrical stimuli in cats (opens in a new tab)

Smith DW, Finley CC

Abstract

The interface between electrode and neural target tissue is thought to influence certain characteristics of neural and behavioral responses to electrical stimulation of the auditory system. At present, the biophysical properties of this interface are not well understood. Here the effects of biphasic phase duration and electrode configuration on psychophysical threshold in response to electrical stimulation in cats are described. Five cats were trained to respond to acoustic stimuli using food as a reward in an operant reinforcement paradigm. After training, the animals were unilaterally deafened and implanted with a multicontact intracochlear electrode array. Thresholds for single presentations of biphasic current pulses were measured as a function of phase duration and electrode arrangement. Statistical analyses of the data indicated that strength-duration function slopes between 200 and 1600 microseconds/phase were significantly different for the different electrode configurations and, overall, were unrelated to the absolute level of the strength-duration function (i.e., were independent of absolute threshold). For all subjects, the slope of this function for intermediate pulse durations was dependent on electrode configuration and most shallow for radial-bipolar configurations (-3.4 dB/doubling), was steepest for monopolar arrangements (-5.9 dB/doubling), and was intermediate for longitudinal-bipolar pairings. (-4.4 dB/doubling). Slopes for both shorter and longer phase duration stimuli were not significantly different. The underlying mechanisms for these effects may include, or be a combination of altered electrical field patterns, integrated activity across multiple fibers, and stochastic behavior of individual auditory neurons to electrical stimulation.

Journal of the American Academy of Audiology · Oct 1997

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions. (opens in a new tab)

Chertoff ME, Guruprasad SN

AP2DA2PA4ABR/DPOAE
Abstract

This study examined the influence of a calibrated transient stimulus on click evoked otoacoustic emissions (CEOAEs). The calibration procedure produced a spectrally uniform stimulus (1-8 kHz) at the plane of the ear probe that was very similar among individuals. However, the calibrated signal reduced the overall level and repeatability of the CEOAE, probably due to the minimization of the energy peak at 2 kHz, which is enhanced in the uncalibrated signal. The amplitude of CEOAEs obtained with the calibrated signal was less variable among individuals compared to CEOAEs obtained with the uncalibrated signal.

Visual Neuroscience · Sep 1997

Neuronal responses in extrastriate cortex to objects in optic flow fields (opens in a new tab)

Sherk H, Mulligan K, Kim JN

Abstract

During locomotion, observers respond to objects in the environment that may represent obstacles to avoid or landmarks for navigation. Although much is known about how visual cortical neurons respond to stimulus objects moving against a blank background, nothing is known about their responses when objects are embedded in optic flow fields (the patterns of motion seen during locomotion). We recorded from cells in the lateral suprasylvian visual area (LS) of the cat, an area probably analogous to area MT. In our first experiments, optic flow simulations mimicked the view of a cat trotting across a plain covered with small balls; a black bar lying on the balls served as a target object. In subsequent experiments, optic flow simulations were composed of natural elements, with target objects representing bushes, rocks, and variants of these. Cells did not respond to the target bar in the presence of optic flow backgrounds, although they did respond to it in the absence of a background. However, 273/423 cells responded to at least one of the taller, naturalistic objects embedded in optic flow simulations. These responses might represent a form of image segmentation, in that cells detected objects against a complex background. Surprisingly, the responsiveness of cells to objects in optic flow fields was not correlated with preferred direction as measured with a moving bar or whole-field texture. Because the direction of object motion was determined solely by receptive-field location, it often differed considerably from a cell's preferred direction. About a quarter of the cells responded well to objects in optic flow movies but more weakly or not at all to bars moving in the same direction as the object, suggesting that the optic flow background modified or suppressed direction selectivity.

Hearing Research · Sep 1997

Directional response properties of saccular afferents of the toadfish, Opsanus tau (opens in a new tab)

Fay RR, Edds-Walton PL

Abstract

The displacement sensitivity, frequency response, and directional response properties of primary saccular afferents of toadfish (Opsanus tau) were studied in response to a simulation of acoustic particle motion for which displacement magnitudes and directions were manipulated in azimuth and elevation. Stimuli were 50, 100, and 200 Hz sinusoidal, translatory oscillations of the animal at various axes in the horizontal and midsagittal planes. Thresholds in these planes defined a cell's characteristic axis (the axis having the lowest threshold) in spherical coordinates. Recordings were made from afferents in rostral, middle, and caudal bundles of the saccular nerve. The most sensitive saccular afferents responded with a phase-locked response to displacements as small as 0.1 nm. This sensitivity rivals that of the mammalian cochlea and is probably common to the sacculi and other otolith organs of most fishes. Most afferents showed lower thresholds at 100 Hz than at 50 or 200 Hz. Eighty percent of afferents have three-dimensional directional properties that would be expected if they innervated a group of hair cells having the same directional orientation on the saccular epithelium. Of the afferents that are not perfectly directional, most appear to innervate just two groups of hair cells having different orientations. The directional characteristics of afferents are qualitatively correlated with anatomically defined patterns of hair cell orientation on the saccule. In general, azimuths of best sensitivity tend to lie parallel to the plane of the otolith and sensory epithelium. Elevations of best sensitivity correspond well with hair cell orientation patterns in different regions of the saccular epithelium. Directional hearing in the horizontal plane probably depends upon the processing of interaural differences in overall response magnitude. These response differences arise from the gross orientations of the sacculi and are represented, in part, as time differences among nonspontaneous afferents that show level-dependent phase angles of synchronization. Directional hearing in the vertical plane may be derived from the processing of across-afferent profiles of activity within each saccule. Fishes were probably the first vertebrates to solve problems in sound source localization, and we suggest that their solutions formed a model for those of their terrestrial inheritors.

Ear & Hearing · Aug 1997

Subjective judgments of speech clarity measured by paired comparisons and category rating (opens in a new tab)

Eisenberg LS, Dirks DD, Gornbein JA

Abstract

Objective The purpose of this study was to compare listeners' subjective judgments of speech clarity via paired comparisons and category rating using stimulus conditions that varied in the relative spacing between stimulus items, producing either a wide or narrow range of performance. Design Subjective judgments of speech clarity were measured via paired comparisons and category rating in 12 normal-hearing (Experiment 1) and eight hearing-impaired adults (Experiment 2). Sentences processed by six band-pass filters that increased monotonically in Articulation Index (AI) estimates constituted the stimuli to be judged. Using subsets of three filters from the group of six, subjective judgments were additionally obtained for stimulus conditions in which the performance ranges were wide (large differences in AI) and narrow (small differences in AI). Results Speech clarity judgments obtained by paired comparisons and category rating were highly related to the AI estimates both for normal-hearing and hearing-impaired subjects. When the performance range was wide, both methods provided similar judgments for the normal-hearing subjects. For the hearing-impaired subjects, paired comparisons were more sensitive than category rating. When the performance range was narrow, paired comparisons were more sensitive than category rating in differentiating between filters for both groups of subjects. This difference was less obvious for the normal-hearing subjects when paired comparison data were converted to a scale comparable to the category ratings. Large between-subject variability was evident for the hearing-impaired subjects on the psychophysical scaling procedures, most notably for category rating. Conclusions When judging the clarity among stimulus items where performance varied over a wide range, both category rating and paired comparisons provided comparable judgments for normal-hearing listeners. For conditions in which perceptual differences between stimulus items were restricted either by the choice of conditions or by the effects of sensorineural hearing loss, the method of paired comparisons was the more sensitive procedure.

The Laryngoscope · Aug 1997

Calcium Channel Blockade Reduces Noise‐Induced Vascular Permeability in Cochlear Stria Vascularis (opens in a new tab)

Goldwyn BG, Quirk WS

Abstract

Exposure to noise results in multiple perturbations of cochlear microcirculation, including increases in vascular permeability. There is evidence that these events are mediated, in part, by calcium channels. The current study examined the effects of calcium channel blockade on the diameter and permeability of cochlear vessels during noise exposure. Subjects were exposed to either noise alone or noise after verapamil pretreatment. Vessels of the cochlear stria vascularis were imaged using intravital microscopy. Animals exposed to noise showed decreases in diameter and increased permeability above baseline levels. Animals pretreated with the calcium channel blocker verapamil and exposed to noise demonstrated increases in vessel diameter and no changes in permeability. These data indicate that calcium channel blockade reduces noise-induced microvascular permeability. Treatment strategies designed to protect from increases in vascular permeability due to noise exposure may reduce temporary threshold shifts.

The Journal of the Acoustical Society of America · Jun 1997

Auditory filters measured at neighboring center frequencies (opens in a new tab)

Fagelson MA, Champlin CA

Abstract

Auditory filters were derived in 20 normal-hearing human listeners at center frequencies (CFs) of 913, 1095, 3651, and 4382 Hz using the roex (p,r) method. Comparisons were made between slopes of the filters' skirts at the neighboring CFs with filter output levels of 45 and 70 dB. The same comparisons were made with regard to filter equivalent rectangular bandwidth (ERB). In the 1000-Hz region, the low-frequency slopes (Pl) of filters centered at 913 and 1095 Hz were significantly correlated at both stimulus levels, while the high-frequency slopes (Pu) were similar only at the high test level. In the 4000-Hz region, for sinusoids of 3651 and 4382 Hz, the level effect was clearer as both Pu and Pl values diverged at the low level but were related at high levels. The ERBs centered at the same CFs displayed a similar level dependence. At the stimulus level most likely to be affected by an active feedback mechanism, auditory filters centered at nearly the same frequency displayed quite distinct frequency selectivity, and this trend was stronger in the 4000-Hz region than the 1000-Hz region. The findings suggest that a saturating, active cochlear mechanism may not be distributed evenly, or contribute to peripheral tuning with equal effectiveness throughout the length of the partition.

The Journal of the Acoustical Society of America · May 1997

Spectral weights in level discrimination by preschool children: Synthetic listening conditions (opens in a new tab)

Willihnganz MS, Stellmack MA, Lutfi RA, Wightman FL

Abstract

On most auditory discrimination and detection tasks young children perform more poorly than adults. The current experiment applies a technique which potentially can reveal the extent to which the adult-child performance difference results from suboptimal attentional strategies or simply greater internal noise in the children. In this experiment preschool children and adults were asked to discriminate between complex tones comprised of three random-amplitude sinusoidal components. A trial-by-trial correlational analysis [R. A. Lutfi, J. Acoust. Soc. Am. 97, 1333-1334 (1995)] provided an estimate of the weight listeners placed on the level information from individual spectral components in making the discrimination. The patterns of weights were interpreted as measures of "attentional strategy." Both children and adults produced reliable patterns of weights. This is an especially important result since measuring a single weighting pattern requires large numbers of trials and hence multiple sessions with the children. While individual weighting patterns were reliable, weighting patterns differed both within and across groups. Moreover, neither the children nor the adults produced weighting patterns that would maximize percent correct in the task. A substantial proportion of the responses from both children and adults could be predicted from their weighting patterns even when performance was near chance. However, differences in overall performance between children and adults could not be accounted for by differences in their weighting functions.

The Journal of the Acoustical Society of America · May 1997

Spectral weights in level discrimination by preschool children: Analytic listening conditions (opens in a new tab)

Stellmack MA, Willihnganz MS, Wightman FL, Lutfi RA

Abstract

In this series of experiments, adult and child listeners were required to attend to a target tone in the presence of two distracters and to indicate in which of two intervals the target tone had the higher level. The attentional weight listeners placed on each component was estimated by computing the correlation between the level change of each component across intervals and the listener's response. In the first experiment, weights were obtained as a function of the mean level of the distracters (250 and 4000 Hz) for a 1000-Hz target. No consistent differences between the weighting functions of children and adults were observed. In a second experiment, weights were obtained as a function of the harmonic relationship between the distracters (250 and 4000 Hz, or 270 and 4320 Hz) and the 1000-Hz target. No difference was observed between the weighting functions computed with harmonic and inharmonic complexes. In the final experiment, each component of the complex (250, 1000, and 4000 Hz) was identified as the target in separate blocks of trials. In general, adults were able to weight the target component appropriately regardless of its frequency, while children tended to weight all components equally. The results suggest that preschool listeners may exhibit poorer attentional selectivity than adults.

The Journal of the Acoustical Society of America · Apr 1997

Basilar-membrane responses to tones at the base of the chinchilla cochlea (opens in a new tab)

Ruggero MA, Rich NC, Recio A, et al.

Abstract

Basilar-membrane responses to clicks were measured, using laser velocimetry, at a site of the chinchilla cochlea located about 3.5 mm from the oval window (characteristic frequency or CF: typically 8-10 kHz). They consisted of relatively undamped oscillations with instantaneous frequency that increased rapidly (time constant: 200 microseconds) from a few kHz to CF. Such frequency modulation was evident regardless of stimulus level and was also present post-mortem. Responses grew linearly at low stimulus levels, but exhibited a compressive nonlinearity at higher levels. Velocity-intensity functions were almost linear near response onset but became nonlinear within 100 microseconds. Slopes could be as low as 0.1-0.2 dB/dB at later times. Hence, the response envelopes became increasingly skewed at higher stimulus levels, with their center of gravity shifting to earlier times. The phases of near-CF response components changed by nearly 180 degrees as a function of time. At high stimulus levels, this generated cancellation notches and phase jumps in the frequency spectra. With increases in click level, sharpness of tuning deteriorated and the spectral maximum shifted to lower frequencies. Response phases also changed as a function of increasing stimulus intensity, exhibiting relative lags and leads at frequencies somewhat lower and higher than CF, respectively. In most respects, the magnitude and phase frequency spectra of responses to clicks closely resembled those of responses to tones. Post-mortem responses were similar to in vivo responses to very intense clicks.

Journal of Speech, Language, and Hearing Research · Apr 1997

Selected cognitive factors and speech recognition performance among young and elderly listeners (opens in a new tab)

Gordon-Salant S, Fitzgibbons PJ

Abstract

The influence of selected cognitive factors on age-related changes in speech recognition was examined by measuring the effects of recall task, speech rate, and availability of contextual cues on recognition performance by young and elderly listeners. Stimuli were low and high context sentences from the R-SPIN test presented at normal and slowed speech rates in noise. Response modes were final word recall and sentence recall. The effects of hearing loss and age were examined by comparing performances of young and elderly listeners with normal hearing and young and elderly listeners with hearing loss. Listeners with hearing loss performed more poorly than listeners with normal hearing in nearly every condition. In addition, elderly listeners exhibited poorer performance than younger listeners on the sentence recall task, but not on the word recall task, indicating that added memory demands have a detrimental effect on elderly listeners' performance. Slowing of speech rate did not have a differential effect on performance of young and elderly listeners. All listeners performed well when stimulus contextual cues were available. Taken together, these results support the notion that the performance of elderly listeners with hearing loss is influenced by a combination of auditory processing factors, memory demands, and speech contextual information.

Journal of Comparative Physiology. A, Sensory, Neural, and Behavioral Physiology · Apr 1997

Dipole source localization by the mottled sculpin II. The role of lateral line excitation patterns (opens in a new tab)

Coombs S, Conley RA

Abstract

Extracellular, single unit recording techniques were used to measure the responses of posterior lateral line nerve fibers to a 50-Hz dipole source that slowly changed its location along the length of the fish. The flow-field equations for a dipole source were used to model the pressure gradient pattern and thus, the expected excitation pattern along a linear array of lateral line receptor organs for different source locations. Finally, excitation patterns were similarly modeled along the left and right side of the fish's head for actual steps taken by sculpin in approach pathways to the 50-Hz dipole source. Spatial histograms of posterior lateral line nerve fiber responses to different locations of the dipole source could be predicted from pressure gradient patterns modeled from the flow-field equations, confirming that the modeling approach applied to behavioral results was a good predictor of excitation patterns likely to be encoded by the lateral line periphery. An examination of how modeled excitation patterns changed from one position to the next in typical approach pathways and how patterns differed between positions from which successful and unsuccessful strikes were launched suggests that approach and strike strategies can indeed be explained by the information available in excitation patterns. In particular, changes in the spatial distribution of pressure gradient directions (polarities), available only when the source is lateral (as opposed to directly in front of the fish), appear to enhance the ability of sculpin to determine source distance. Without such information, misses are more likely to occur and successful strikes are more likely to be launched from short distances only.

The Journal of the Acoustical Society of America · Apr 1997

Age-related changes in temporal gap detection (opens in a new tab)

Snell KB

Abstract

The purpose of this study was to clarify and extend the results of earlier studies of age-related effects on temporal resolution by precisely matching young and old subjects with normal hearing and measuring gap thresholds in a variety of listening conditions. Younger subjects were between 17 and 40 years of age, older subjects between 64 and 77 years. Signals were noisebursts which varied in upper-cutoff frequency, overall level, and sinusoidal-amplitude-modulation depth. Signals were presented in quiet, in a noise floor, and with a gated-high-frequency masker in a noise floor. Significant main effects were found for signal frequency, intensity, modulation, age, and background condition. Mean gap thresholds ranged between 2.1 and 10.1 ms and were larger for the older subjects in all 24 conditions. In some conditions, introduction of a noise floor increased the gap thresholds of the older subjects relative to those of the younger. Analyses of individual data support the conclusion that the mean differences between groups reflect shifts in the distributions of gap thresholds of the older subjects towards poorer temporal resolution.

The Journal of Neuroscience · Mar 1997

Representation of accurate temporal information in the electrosensory system of the African electric fish, Gymnarchus niloticus (opens in a new tab)

Guo YX, Kawasaki M

Abstract

Differential-phase-sensitive neurons in the electrosensory lateral line lobe (ELL) of the African electric fish, Gymnarchus niloticus, are sensitive to time disparities on the order of microseconds between afferent action potentials. These action potentials fire in a phase-locked manner in response to the animal's own wave-type electric organ discharges (EODs) (). The time disparity is one of the essential cues for an electrical behavior, the jamming avoidance response (JAR). To gain an insight into the accurate temporal processing in the ELL, firing time accuracy and dynamic response properties of action potentials of the phase-locked neurons (PLNs) in the ELL were examined. The temporal accuracy of the entire neuronal circuit for the JAR was also measured using behavioral responses. Standard deviation of firing times of PLNs' action potentials was approximately 6 micro;sec. The PLNs represent zerocrossing times of each stimulus cycle with this accuracy even when stimulus phase was modulated at high frequencies ( approximately 50 Hz). Distinct JAR occurred when time disparity was diminished below 1 micro;sec, and a marginal JAR could still be detected with a time disparity of 100 nsec. Standard deviation of the firing times of EODs was approximately several hundred nanoseconds. This stability of the EOD, however, was demonstrated to be unnecessary for the JAR. JARs occurred even when a large artificial jitter ( approximately 60 micro;sec) was introduced to a stimulus that mimicked fish's own EOD and the time disparity for JAR was diminished to 1 micro;sec. This immunity of JAR to the EOD jitter is explained by the insensitivity of the differential-phase-sensitive neurons in the ELL to a common phase modulation. The JAR of the South American electric fish, Eigenmannia, also occurs in response to stimuli that generate comparably small phase differences (; ). The present study revealed that the independently evolved Eigenmannia and Gymnarchus exhibit a comparative level of remarkable temporal accuracy.

Journal of Neurophysiology · Mar 1997

Neural Selectivity and Tuning for Sinusoidal Frequency Modulations in the Inferior Colliculus of the Big Brown Bat, Eptesicus fuscus (opens in a new tab)

Casseday JH, Covey E, Grothe B

Abstract

Most communication sounds and most echolocation sounds, including those used by the big brown bat (Eptesicus fuscus), contain frequency-modulated (FM) components, including cyclical FM. Because previous studies have shown that some neurons in the inferior colliculus (IC) of this bat respond to linear FM sweeps but not to pure tones or noise, we asked whether these or other neurons are specialized for conveying information about cyclical FM signals. In unanesthetized bats, we tested the response of 116 neurons in the IC to pure tones, noise with various bandwidths, single linear FM sweeps, sinusoidally amplitude-modulated signals, and sinusoidally frequency-modulated (SFM) signals. With the use of these stimuli, 20 neurons (17%) responded only to SFM, and 10 (9%) responded best to SFM but also responded to one other test stimulus. We refer to the total 26% of neurons that responded best to SFM as SFM-selective neurons. Fifty-nine neurons (51%) responded about equally well to SFM and other stimuli, and 27 (23%) did not respond to SFM but did respond to other stimuli. Most SFM-selective neurons responded to a limited range of modulation rates and a limited range of modulation depths. The range of modulation rates over which individual neurons responded was 5-170 Hz (n = 20). Thus SFM-selective neurons respond to low modulation rates. The depths of modulations to which the neurons responded ranged from +/-0.4 to +/-19 kHz (n = 15). Half of the SFM-selective neurons did not respond to the first cycle of SFM. This finding suggests that the mechanism for selective response to SFM involves neural delays and coincidence detectors in which the response to one part of the SFM cycle coincides in time either with the response to a later part of the SFM cycle or with the response to the first part of the next cycle. The SFM-selective neurons in the IC responded to a lower and more limited range of SFM rates than do neurons in the nuclei of the lateral lemniscus of this bat. Because the FM components of biological sounds usually have low rates of modulation, we suggest that the tuning of these neurons is related to biologically important sound parameters. The tuning could be used to detect FM in echolocation signals, modulations in high-frequency sounds that are generated by wing beats of some beetles, or social communication sounds of Eptesicus.

The Journal of Neuroscience · Mar 1997

Effects of interaural intensity difference on the processing of interaural time difference in the owl’s nucleus laminaris (opens in a new tab)

Svenja Viete, José Luis Peña, Masakazu Konishi

Abstract

Interaural time and intensity differences (ITD and IID) are processed independently in the owl’s auditory system. This paper examines whether this independence is established in nucleus laminaris (NL), the first site of ITD processing. A plot of discharge rate against time difference (ITD curve) is sinusoidal in NL. The ITDs that produce the peaks are called the most favorable ITDs, and those that produce the troughs are called the least favorable ITDs. IID had little effect on the discharge rates of laminaris neurons for the most and least favorable ITDs. The degree of peak–trough modulation changed slightly with variation in IID. In contrast, IID in tonal stimuli affected the temporal aspect of ITD curves depending on the difference between the stimulus frequency and the neuron’s best frequency (BF). For frequencies below BF, IID caused large and systematic shifts in ITD toward the ear in which the sound was louder, whereas for frequencies above BF, IID caused small shifts in ITD toward the opposite ear. IID had little effect on ITD curves taken with BF or broadband noise. These results can be largely accounted for by the effects of frequency and intensity on the timing of impulses at the level of the cochlear nuclei. Thus, the processing of ITD by NL neurons is independent of IID for behaviorally relevant stimuli, because the timing of impulses is insensitive to sound level when the signal is broadband.

Journal of Neurophysiology · Feb 1997

Simulated optic flow and extrastriate cortex. I. Optic flow versus texture (opens in a new tab)

Kim JN, Mulligan K, Sherk H

Abstract

A locomoting observer sees a very different visual scene than an observer at rest: images throughout the visual field accelerate and expand, and they follow approximately radial outward paths from a single origin. This so-called optic flow field is presumably used for visual guidance, and it has been suggested that particular areas of visual cortex are specialized for the analysis of optic flow. In the cat, the lateral suprasylvian visual area (LS) is a likely candidate. To test the hypothesis that LS is specialized for analysis of optic flow fields, we recorded cell responses to optic flow displays. Stimulus movies simulated the experience of a cat trotting slowly across an endless plain covered with small balls. In different simulations we varied the size of balls, their organization (randomly or regularly dispersed), and their color (all one gray level, or multiple shades of gray). For each optic flow movie, a "texture" movie composed of the same elements but lacking optic flow cues was tested. In anesthetized cats, > 500 neurons in LS were studied with a variety of movies. Most (70%) of 454 visually responsive cells responded to optic flow movies. Visually responsive cells generally preferred optic flow to texture movies (69% of those responsive to any movie). The direction in which a movie was shown (forward or reverse) was also an important factor. Most cells (68%) strongly preferred forward motion, which corresponded to visual experience during locomotion.