TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

The Journal of the Acoustical Society of America · Feb 1996

A time domain description for the pitch strength of iterated rippled noise (opens in a new tab)

Yost WA, Patterson R, Sheft S

Abstract

Two versions of a cascaded add, attenuate, and delay circuit were used to generate iterated rippled noise (IRN) stimuli. IRN stimuli produce a repetition pitch whose strength relative to the noise can be varied by changing the type of circuit, the attenuation, or the number of iterations in the circuit. Listeners were asked to discriminate between various pairs of IRN stimuli which differed in the type of network used to generate the sounds or the number of iterations (n = 1, 2, 3, 4, 7, and 9). Performance was determined for IRN stimuli generated with delays of 2, 4, and 8 ms and for four bandpass filter conditions (0-2000, 250-2000, 500-2000, and 750-2000 Hz). Some IRN stimuli were extremely difficult to discriminate despite relatively large spectral differences, while other IRN stimuli produced readily discriminable changes in perception, despite small spectral differences. these contrasting results are inconsistent with simple spectral explanations for the perception of IRN stimuli. An explanation based on the first peak of the autocorrelation function of IRN stimuli is consistent with the results. Simulations of the processing performed by the peripheral auditory system (i.e., interval histograms and correlograms) produce results which are consistent with the involvement of these temporal processes in the perception of IRN stimuli.

The Journal of the Acoustical Society of America · Feb 1996

Sound localization in noise: The effect of signal‐to‐noise ratio (opens in a new tab)

Good MD, Gilkey RH

Abstract

The sound localization ability of human observers has been frequently examined in quiet environments, but there have been relatively few studies that have considered the effect of noise on sound localization. In this study, three subjects judged the perceived direction of broadband click-train signal in the quiet and in the presence of a broadband noise at nine signal-to-noise ratios, which varied over a 23 dB range. The signal could originate from any of 239 spatial locations that completely surrounded the subjects in azimuth 360 degrees) and ranged from -45 degrees to (+)90 degrees in elevation; the masker (when present) was always located directly in front of the subjects at 0 degrees azimuth and 0 degree elevation. The subjects indicated the perceived direction of the signal by pointing at a 20-cm-diam spherical model of auditory space. As the signal-to-noise ratio was lowered, the accuracy of localization judgments decreased nearly monotonically. However, the accuracy of judgments relative to the median plane (i.e., the left/right dimension) was less strongly influenced by the presence of noise than was the accuracy of judgments relative to the horizontal plane (i.e., the up/down dimension). The accuracy of judgments relative to the frontal plane (i.e., the front/back dimension) was most strongly influenced by noise.

The Journal of Neuroscience · 1996

Neuronal circuitry for comparison of timing in the electrosensory lateral line lobe of the African wave-type electric fish Gymnarchus niloticus (opens in a new tab)

Kawasaki M, Guo YX

Abstract

An African wave-type electric fish, Gymnarchus, compares timing on the order of microseconds of sensory feedback from from its high-frequency (approximately 400 Hz) electric organ discharges (EODs) received at different parts of its body surfaces. This capability is essential for and demonstrated by the jamming avoidance response (JAR). The organization of the timing comparison mechanisms was identified in the electrosensory lateral line lobe (ELL) in the hindbrain by field potential, extra- and intracellular recordings, and intracellular labeling with biotinylated agents. Timing of phase of the EOD feedback is carried by action potentials of S-type primary afferent fibers that project to the inner cellular layer (ICL) of the medial zone of the ELL and to the giant neurons in the ELL. The giant neurons bilaterally project to the ICL, where neurons sensitive to phase differences between different parts of the body occur. Although sensitive to dynamic phase changes of several microseconds, these differential-phase-sensitive neurons showed adaptation to steady-state changes of phase difference over a wide range (greater than +/- 100 microseconds) and continued to respond to small modulations after the mean difference was shifted. Gymnarchus and an independently evolved South American electric fish, Eigenmannia, exhibit nearly identical JARs and share a rather complex but identical set of computational algorithms for JAR. This study showed that one of the computational steps, the timing comparison between body surfaces, occurs in the hindbrain in Gymnarchus, in contrast to the midbrain in Eigenmannia. Thus, similar systems with a similar overall function may have evolved differently in different genera by assigning a subfunction to different substructures within the brain.

The Journal of the Acoustical Society of America · 1996

Observer weighting of concurrent binaural information (opens in a new tab)

Stellmack MA, Lutfi RA

Abstract

Two experiments examined how listeners weight binaural information of individual components in a multicomponent complex when they are instructed to use this information in various ways. On each experimental trial of the first experiment, a two-component complex consisting of a 553- and 753-Hz pure tone was presented to listeners over headphones. Each component had an interaural difference of time (IDT) that was randomly chosen from a single distribution. Listeners were to indicate the apparent position of the intracranial image relative to the midline on the basis of either the IDT of the 753-Hz component, the sum of the IDTs of the two components, or the difference between the two IDTs. Observer weights for the component IDTs were derived by computing the point-biserial correlations between the IDTs of the components and the listeners' left-right judgments. Three of the four listeners were found to adjust their weighting of the binaural information appropriately for each listening task, while the fourth listener consistently gave almost no weight to the 553-Hz component regardless of the listening condition. In a second experiment, listeners were instructed to attend to the randomly selected IDT of one of three components (553, 753, or 953 Hz) and to indicate whether the intracranial image produced by that component was to the left or right of midline. Only one of six listeners gave greatest weight to the target component regardless of its frequency. The other five listeners gave significant weight to all three components in all listening conditions. In all cases, individual differences in percent correct performance could be attributed largely to individual differences in weights with little variation in internal noise.

The Journal of the Acoustical Society of America · Dec 1995

Lateralization of comodulated complex waveforms (opens in a new tab)

Saberi K

Abstract

This study examines the ability to lateralize a complex signal characterized by correlated temporal activity across widely separated frequency regions. The high-frequency complex consisted of two narrow-band stimuli. The two stimuli had common interaural delays but different carriers centered on nonoverlapping critical bands. Two basic conditions were examined: The narrow-band stimuli had temporal envelopes which were (1) identical or (2) different. In the first experiment, narrow bands of noise were used which either had identical temporal envelopes (comodulated) or statistically independent envelopes (CFs = 2550 and 3350 Hz). In the second experiment, two sinusoidally amplitude-modulated (SAM) tones were used whose modulators either had the same starting phase or a different starting phase (CFs = 2550 and 4000 Hz). Results of the first experiment showed that for bandwidths narrower than 300 Hz, comodulated bands produced significantly lower interaural-delay thresholds compared to independent bands. Results of the second experiment showed that when the two SAM tones (100-Hz modulation rate) had the same modulator starting phase, interaural-delay thresholds were lowest.

The Journal of the Acoustical Society of America · Dec 1995

Age effects on duration discrimination with simple and complex stimuli (opens in a new tab)

Fitzgibbons PJ, Gordon-Salant S

Abstract

This study examined age-related changes in temporal processing by measuring DLs for signal duration using simple and complex stimuli. Previous research has shown that elderly listeners exhibit difficulty discriminating duration changes in simple sounds, suggesting the possibility of age-related changes in central timing mechanisms. The present experiments examined the interactive effects of aging, hearing loss, and stimulus complexity on duration discrimination. Four groups participated: young and elderly listeners with normal hearing, and young and elderly listeners with hearing loss. Duration DLs were measured for 250-ms tone bursts and for silent gaps between tone bursts that were presented either in isolation or embedded as target stimuli within tonal sequences. The tone sequences were composed of five sequential 250-ms components. Stimulus complexity was varied by changing the sequential order of tone frequencies and the location of an embedded target component across listening conditions. Analyses of results revealed the following: Elderly listeners performed more poorly than younger listeners in nearly all stimulus conditions, the effects of stimulus complexity on discrimination were greatest among elderly listeners, and hearing loss had no systematic effect on discrimination performance.

Journal of Vestibular Research · Nov 1995

The accuracy of absolute localization judgments for speech stimuli (opens in a new tab)

Gilkey RH, Anderson TR

Abstract

Communication signals are likely to be one of the primary forms of acoustic stimulation within three-dimensional auditory displays, yet the ability to localize these signals has received relatively little study. We investigated the ability to localize single-word speech targets, spoken by one male and one female talker, as compared to the ability to localize click targets. On each trial, the targets could arise from any one of 239 speaker locations that surrounded the subject in azimuth and ranged from -45 degrees to +90 degrees in elevation. The results showed that localization accuracy relative to the median plane (the Left/Right dimension) was good for both the speech and nonspeech targets. However, with speech targets, there were more front/back reversals (inaccurate judgments relative to the frontal plane, the Front/Back dimension) and typically less accurate elevation judgments (inaccurate judgments relative to the horizontal plane, the Up/Down dimension) than were found with click targets. These results have important implications for applications of spatial hearing technology and suggest that need for caution when designing three-dimensional auditory displays in order to assure that spatial information is conveyed appropriately.

Journal of Speech and Hearing Research · Oct 1995

Reliability and sensitivity of paired comparisons and category rating in children (opens in a new tab)

Eisenberg LS, Dirks DD

Abstract

Children's subjective judgments of speech clarity using the methods of paired comparisons and category rating were evaluated in this investigation. Eighty children with normal hearing between the ages of 4 and 8 years judged the clarity of sentences that were systematically bandpass-filtered using conditions that increased intelligibility as estimated by the Articulation Index. Subjects were classified into four age groups (4-, 5-, 6-, and 7-8-year age groups) with 20 subjects per group. With use of materials and training methods suitable for children, judgments were obtained via the two psychophysical procedures (10 subjects per age group for each procedure). Results indicated that children 5 years of age and older were able to make reliable clarity judgments using either procedure; however, the method of paired comparisons was more sensitive than category rating in detecting differences between the bandpass-filtered conditions.

Hearing Research · Oct 1995

Combination-sensitive neurons in the inferior colliculus (opens in a new tab)

Mittmann DH, Wenstrup JJ

Abstract

We examined whether neurons in the inferior colliculus of the mustached bat (Pteronotus parnellii) are combination sensitive, responding to both low- and high-frequency components of the bat's sonar signal. These neurons, previously reported in the thalamus and cortex, analyze sonar target features including distance. Of 82 single units and 36 multiple units from the 58-112 kHz representations of the inferior colliculus, most (86%) displayed sensitivity to low-frequency sounds that was tuned in the range of the fundamental biosonar component (24-31 kHz). All histologically localized units were in the central nucleus of the inferior colliculus (ICC). There were two major types of combination-sensitive influences. Many neurons were facilitated by low-frequency sounds and selective for particular delays between the low- and high-frequency components. In other neurons, the low-frequency signal was inhibitory if presented simultaneously or a few milliseconds prior to the high-frequency signal. The results indicate that mechanisms creating specialized frequency comparisons and delay sensitivity in combination-sensitive neurons operate at the ICC or below. Since combination sensitivity or multipeaked tuning curves occur in the auditory systems of many species, ICC neurons in these animals may also respond to species-specific frequency combinations.

The Journal of the Acoustical Society of America · Sep 1995

The effects of sinusoidal amplitude modulation on gap detection in noise (opens in a new tab)

Snell KB

Abstract

The purpose of this study was to investigate the effects of envelope fluctuation on temporal gap detection. Temporal gap detection thresholds were measured in wideband noisebursts that had been amplitude modulated by a very low-frequency sinusoid. Detection was studied at six modulation depths and in four phase conditions which placed the onset of the silent gap at different amplitudes on the temporal envelope of the waveform. Gap thresholds were obtained in a 3IFC paradigm in four young, normal-hearing subjects. The smallest mean gap threshold, 3.5 ms, was obtained for unmodulated noisebursts. The largest mean gap threshold, 25.7 ms, was obtained at a modulation depth of 100%. Phase did not significantly affect gap detection until modulation depth was increased to 40%. At deeper depths of modulation, gap thresholds were smallest, but also most variable, when the gap onset was placed at a peak in the waveform envelope and largest when the gaps were centered on an envelope minimum or randomly placed. Results of this study are consistent with previous findings and the hypothesis that gap detection is dependent on the similarity of the gap itself to inherent fluctuations in the stimulus envelope, reflecting coherence in terms of phase and depth of envelope fluctuation.

Audiology · Jul 1995

Reliability of auditory brainstem responses from sequenced high-frequency (≥ 8 kHz) tonebursts (opens in a new tab)

Fausti SA, Mitchell CR, Frey RH, … Phillips DS

Abstract

An auditory brainstem response method is described for evoking responses to 4 high-frequency (8, 10, 12 and 14 kHz) tonebursts in the same amount of time normally required to obtain responses to single tonebursts. Reliability of responses to high-frequency toneburst stimuli presented in the conventional manner (one at a time) has been previously documented. In the present study, high-frequency tonebursts were presented to 20 normal-hearing subjects singly and in a 4-stimulus sequence. The reliability of resulting responses did not differ significantly between single- and multiple-stimulus test conditions. It is concluded that this sequenced-stimulus concept could be developed for use in serial monitoring of individuals receiving ototoxic agents as well as being broadly applicable to clinical situations in which patients cannot or will not respond voluntarily.

The Journal of the Acoustical Society of America · Jul 1995

Behavioral auditory thresholds for sinusoidal electrical stimuli in the cat (opens in a new tab)

Smith DW, Watt S, Konrad KE, Olszyk VB

Abstract

Behavioral thresholds were measured in four cats by training them to respond behaviorally to acoustic auditory stimuli using food as a reward in an operant reinforcement paradigm. Following training, the subjects were implanted unilaterally with either a scaled-UCSF electrode containing four contacts or an electrode array containing eight intracochlear contacts and one extracochlear contact under temporalis muscle. Behavioral thresholds for electrical stimuli were obtained as a function of sinusoidal frequency, duration, and electrode configuration. Threshold functions for both electrode types and all animals had minima between 48 and 125 Hz and, in general, were relatively flat below this minima; functions increased at 3-6 dB/octave from 96 Hz to 1 kHz. Threshold varied predictably as a function of electrode configuration, with thresholds decreasing as much as 20 dB as electrode spacing was widened from a radial bipolar (200-microns separation) to a monopolar configuration (apical stimulating and temporalis return). With long-duration stimuli, increasing the electrode separation systematically increased the slope of the threshold-versus-frequency contours in all animals. Irrespective of electrode type or configuration, charge/phase thresholds for single-cycle sinusoids were relatively flat for stimulus periods up to 1-5 ms, approximating a constant charge/phase determination of threshold. At phase durations greater than 5 ms, charge thresholds increased at a rate slightly above 6 dB/octave (constant peak current), which was suggestive of neural accommodation. Thresholds for the cat share many features with those reported for implanted humans and monkeys.

The Journal of the Acoustical Society of America · May 1995

Within‐and across‐channel processes in modulation detection interference (opens in a new tab)

Mendoza L, Hall JW 3rd, Grose JH

Abstract

Modulation detection interference (MDI) describes the effect of an amplitude-modulated sound on detection of amplitude modulation (AM) on a spectrally distant target sound. In MDI, AM detection is worsened by an AM interfering sound. Previous research has implicated both within-channel and across-channel processes as the basis for MDI. This study examined the detection of 10-Hz sinusoidal AM as a function of the spectral relationship, gating synchrony, and ear of presentation of the target and interfering sounds. Using a 993-Hz target sound, AM detection improved as the frequency of the interferer increased from 1250 to 2188 Hz, and as it decreased from 788 to 450 Hz. MDI was less for continuous interferers than for interferers gated synchronously with the target. In the continuous interferer conditions, however, MDI was still greatest for interferers most proximal to the target. The effects of frequency proximity and gating asynchrony were also evident using interferers presented to the ear contralateral to the target ear. While a 1250-Hz interferer led to more MDI than a 788-Hz interferer when the interferers were presented to the same ear as a 993-Hz target, no significant asymmetry was noted with dichotic stimulation. Taken together, the results of these experiments indicated that MDI is the result of across-channel, and to a limited extent, within-channel processes.

The Journal of the Acoustical Society of America · Apr 1995

Masked thresholds and consonant recognition in low‐pass maskers for hearing‐impaired and normal‐hearing listeners (opens in a new tab)

Dubno JR, Ahlstrom JB

Abstract

Thresholds and consonant recognition were measured in six low-pass maskers as a function of masker bandwidth for hearing-impaired subjects and for normal-hearing subjects listening in spectrally shaped broadband noise (SSBB). SSBB was adjusted such that thresholds in that masker for a normal-hearing listener were equal to a hearing-impaired listener's absolute thresholds. Thresholds measured in low-pass maskers were higher for hearing-impaired than for normal-hearing subjects for signal frequencies both within and outside masker passbands, although threshold differences were larger for signal frequencies outside masker passbands. Slopes of functions relating consonant recognition to speech level were not significantly different between groups, due to the presence of SSBB for the normal-hearing listeners. However, 25% of observed scores for hearing-impaired listeners, compared to only 5% of observed scores for normal-hearing listeners, were significantly poorer than predicted by the articulation index (AI), when AIs were computed using subjects' absolute thresholds. Better correspondence between observed and predicted scores in low-pass maskers was achieved when AIs were derived empirically from thresholds measured in each low-pass masker. Hence poorer-than-predicted consonant recognition scores in low-pass maskers were accounted for by higher-than-normal thresholds in those maskers.

Acta Oto-Laryngologica · Mar 1995

Contralateral suppression of evoked otoacoustic emissions and detection of a multi-tone complex in noise (opens in a new tab)

Micheyl C, Morlet T, Giraud AL, … Morgon A

Abstract

Although some findings suggest that auditory efferent fibers are involved in perception in noise, their function remains controversial. The contralateral suppression of evoked otoacoustic emissions (EOAEs) has recently provided a means of exploring the medial olivocochlear system (MOCS) in humans. In an experiment based on this paradigm, the present study examined the relationships between variations of both EOAEs and detection-in-noise thresholds, induced in the same subjects by a contralateral 50-dB-SPL broad-band noise masker. EOAEs were recorded in response to a burst of a multitone complex composed of 1, 1.5 and 2-kHz components. The detection thresholds of this 3-component complex were measured at 2 ipsilateral noise levels: 50 and 70 dB SPL. The main finding was a significant correlation between EOAE suppression and threshold variations under contralateral masking. A relationship was also found between the contralateral suppression of EOAEs and threshold variation induced by the increase in ipsilateral noise level. These findings support the notion that the MOCS is involved in the detection of multicomponent stimuli in noise.