The Journal of Neuroscience · Feb 1998
Matthew A. Friedman, Carl D. Hopkins
Abstract
Mormyrid electric fish have species- and sex-typical electric organ discharges (EODs). One class of tuberous electroreceptors, the knollenorgans, plays a critical role in electric communication; one function is species recognition of EOD waveforms. In this paper, we describe cell types in the knollenorgan central pathway, which appear responsible for analysis of the temporal patterns of spikes encoded by the knollenorgans in response to EOD stimuli. Secondary sensory neurons in the nucleus of the electrosensory lateral line lobe (NELL) act as relays of peripheral responses. They fire a single phase-locked spike to an outside positive-going voltage step. Axons from the NELL project to the toral nucleus exterolateralis pars anterior (ELa). Immediately after they enter the ELa, they send collaterals to terminate on one to three ELa large cells and then continue in a lengthy neuronal pathway that traverses the ELa several times. After a path length of up to 5 mm, the NELL axon terminates on as many as 70 ELa small cells. Thus the large cells appear to be excited first, followed by the small cells, with the intervening length of the axon serving as a delay line. The large cells also respond with phase-locked spikes to voltage steps. Large cell axons extend for ∼1 mm and terminate on several small cells within the ELa. The terminals are known to be GABAergic inputs and are presumed inhibitory. We propose that small cells receive direct inhibition from large cells and delayed excitation from NELL axons. The small cells may act as anti-co-incidence detectors to analyze the temporal structure of the EOD waveform.
Proceedings of the National Academy of Sciences of the United States of America · 1998
Mazer JA
Abstract
The barn owl (Tyto alba) uses interaural time difference (ITD) cues to localize sounds in the horizontal plane. Low-order binaural auditory neurons with sharp frequency tuning act as narrow-band coincidence detectors; such neurons respond equally well to sounds with a particular ITD and its phase equivalents and are said to be phase ambiguous. Higher-order neurons with broad frequency tuning are unambiguously selective for single ITDs in response to broad-band sounds and show little or no response to phase equivalents. Selectivity for single ITDs is thought to arise from the convergence of parallel, narrow-band frequency channels that originate in the cochlea. ITD tuning to variable bandwidth stimuli was measured in higher-order neurons of the owl's inferior colliculus to examine the rules that govern the relationship between frequency channel convergence and the resolution of phase ambiguity. Ambiguity decreased as stimulus bandwidth increased, reaching a minimum at 2-3 kHz. Two independent mechanisms appear to contribute to the elimination of ambiguity: one suppressive and one facilitative. The integration of information carried by parallel, distributed processing channels is a common theme of sensory processing that spans both modality and species boundaries. The principles underlying the resolution of phase ambiguity and frequency channel convergence in the owl may have implications for other sensory systems, such as electrolocation in electric fish and the computation of binocular disparity in the avian and mammalian visual systems.
Brain Research · 1998
E Idrizbegovic, N Bogdanovic, B Canlon
American Journal of Audiology · 1998
Frederick N. Martin, Craig A. Champlin, Tracey Parks Marchbanks
Abstract
The use of a procedure that varies the intensity of critical portions of a story for purposes of quantifying the degree of pseudohypacusis was examined. Results indicated that this procedure can be used to identify normal hearing people who are asked to feign a hearing loss. It was found that, for most subjects, it was possible to determine that their true auditory thresholds were at least 30 dB below what they claimed as their voluntary (simulated) levels.
Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 1998
Ellen C. Haas
Abstract
The design and use of 3-D auditory warning signals can potentially enhance helicopter cockpit safety. A study was conducted to determine how quickly helicopter pilots could respond to helicopter malfunction warning signals in a simulated cockpit environment when four different signal functions (fire in left engine, fire in right engine, chips in transmission, shaft-driven compressor failure) were presented in three different presentation modes (visual only, visual plus 3-D auditory speech signals, visual plus 3-D auditory icons). The dependent variable was pilot response time to the warning signal, from the time of signal onset to the time that the pilot manipulated the collective control in the correct manner. Subjects were 12 U.S. Army pilots between the ages of 18 and 35 who possessed hearing and visual acuity within thresholds acceptable to the U.S. Army. Results indicated that signal presentation was the only significant effect. Signal function and the signal presentation x signal function interaction were not significant. Post hoc test results indicated that pilot response time to the visual signals supplemented with 3-D audio speech or auditory icon signals was significantly shorter than that to visual signals only. The data imply that 3-D audio speech and auditory icon signals provide a safe and effective mode of warning presentation in the helicopter cockpit.
Advances in Neural · 1998
J Pezaris
Canadian Acoustics · 1998
Sawada S, Gysin C, Mount RJ, et al.
1998
MD Wiley
Archives of Acoustics · 1998
L Rutkowski, A Wicher
Canadian Acoustics · 1998
P Allen, CL Marples
INTER-NOISE and NOISE · 1998
PC Laux, P Davies
Canadian Acoustics · 1998
N Harel, RJ Mount, RV Harrison
1998
IM Andersson, B Hagerman, AC Johnson, T Lindh
Hearing Research · 1998
Smurzynski J, Probst R
Abstract
The effects of a consistently disappearing and reappearing spontaneous otoacoustic emission (SOAE) at around 2280 Hz on microstructure for pure tones of varying durations in a 33 year-old woman with normal hearing was studied. The SOAE began to appear after 10-15 min in a quiet test room and increased in level by up to 22 dB over a 30-40-min period. The SOAE was measured every 12 to 15 min. Between measurements, the subject performed a signal detection task for pure tones with total durations varying from 20 to 320 ms. The signal frequencies were within a +/- 30-Hz range relative to the SOAE frequency. For signal durations of 40-320 ms, there was a local dip at the target SOAE frequency when it was either not detectable or its level was lower than -14 dB SPL. Subjective threshold levels were as much as 12 dB better than those obtained when the SOAE was -6 dB SPL or greater. The results suggest that a region of the cochlea with high sensitivity and instability can be put into self-oscillation producing an SOAE, possibly by a change of efferent activity. Hearing threshold is affected possibly due to adaptation or masking.
Journal of Experimental Biology · 1998
Pollack G, z
Abstract
Teleogryllus oceanicus is particularly sensitive to two ranges of sound frequency, one corresponding to intraspecific acoustical signals (4-5 kHz) and the other to the echolocation cries of bats (25-50 kHz). We recorded summed responses of the auditory nerve to stimuli in these two ranges. Nerve responses consist of trains of compound action potentials (CAPs), each produced by the summed activity of a number of receptor neurons. The amplitude of the CAP is up to four times larger for stimuli at 4.5 kHz than for stimuli at 30 kHz, suggesting either that the extracellular spikes produced by receptors that respond to 4.5 kHz are larger than those that respond to 30 kHz, or that receptors fire more synchronously in response to stimulation at 4.5 kHz, or that more receptors respond to stimulation at 4.5 kHz. Neither unit spike amplitude nor conduction velocity (which is expected to vary with spike amplitude) differs for the two frequencies, and the responses to 4.5 kHz are not produced by more tightly synchronized receptor populations, as judged by CAP breadth. We conclude that more receptors respond to 4. 5 kHz than to 30 kHz.
Hearing Research · 1998
Conlon BJ, Smith DW
Abstract
There is increasing evidence to suggest that free radical generation is central to a variety of pathological processes, including drug toxicity. Studies demonstrating the ability of gentamicin to facilitate the generation of radical species suggest that this process plays an important role in aminoglycoside-induced ototoxicity. Because transition metals, particularly iron, play an important role in the production of free radicals and the generation of reactive oxygen species, we sought to determine whether gentamicin-induced ototoxicity is exacerbated by increases in serum iron levels. To this end, we assessed the effects of supplemental iron administration (2 mg/kg/day and 6 mg/kg/day) on changes in auditory function induced by co-administration of gentamicin (100 mg/kg/day for 30 days). Experiments were carried out on pigmented guinea pigs initially weighing 250-300 g. Changes in cochlear function were characterized as shifts in compound action potential (CAP) thresholds, estimated every third day throughout the treatment period by use of chronic indwelling electrodes implanted at the round window, vertex, and contralateral mastoid. Results showed that animals receiving iron in combination with gentamicin demonstrated a more rapid and profound elevation in CAP thresholds compared with animals receiving gentamicin alone. This effect occurred in a dose-dependent manner. Animals receiving supplemental iron alone maintained normal CAP thresholds throughout the treatment period. There was no statistically significant difference in serum gentamicin levels between groups receiving gentamicin alone or gentamicin plus iron. These results provide further evidence of the recently reported intrinsic role of iron in aminoglycoside ototoxicity, and highlight a potential risk of aminoglycoside administration in patients with elevated serum iron.
Journal of the Acoustical Society of Japan (E) · 1998
Edward Ozimek, Jacek Konieczny, Yoiti Suzuki, Toshio Sone
Abstract
The aim of this investigation was to determine the detection thresholds of sinusoidal and random changes in envelope of amplitude modulated (AM) signals. The envelope changes were obtained as a result of modulation of a pure-tone carrier by chosen types of modulators, which gave either sinusoidal, pseudorandom, or random (Gaussian) amplitude modulation. For pseudorandom and random modulation, the detection thresholds were determined when only modulation depth (m) of AM signals was changed randomly (fm const) or when both modulation depth and modulation frequency (fm) were changed randomly (fm random). The data showed that for low modulation frequency (fm≤64Hz) the detection thresholds for sinusoidal amplitude modulation (SAM), pseudorandom amplitude modulation (PAM) and random amplitude modulation (RAM) overlapped one another in the limit of the standard deviation (SD). However, for higher modulation frequencies, the average threshold for the RAM (fm, const) was about 3dB lower (around fm=128Hz) than that for sinusoidal amplitude modulation. In this case the PAM threshold was similar, within the limit of SD, to the SAM threshold. However, when random changes in amplitude were combined with random changes in frequency, the PAM (fm, random), and RAM (fm random) thresholds decreased about 5 dB relative to the SAM threshold.
The Journal of the Acoustical Society of America · Dec 1997
Rankovic CM, Levy RM
Abstract
The ability of listeners to estimate articulation scores for lists of nonsense syllables was evaluated. Normal-hearing subjects were presented with lists of from 50 to 60 nonsense syllables that were degraded with various amounts of noise or filtering and were instructed to estimate consonant-correct scores for each condition. To provide a reference for estimating, subjects were shown the accurate orthographic representation of the syllable on a computer monitor to compare with the auditory presentation. The printed version was displayed either simultaneously with the auditory presentation or 500 ms after the offset of the syllable. Estimates were collected on two occasions to examine test-retest reliability, and actual percent-correct scores were obtained to check the accuracy of the estimates. Most subjects overestimated actual scores when the printed representation was provided simultaneously, but estimates were strikingly similar to actual scores when the printed representation was delayed. The delay appeared to prevent the printed representation from favorably biasing the reception of the syllable. The average of two or three estimates gave highly repeatable results for both visual displays. Crossover frequencies derived from the filtered-speech conditions were within the range reported in the literature. This supports the conclusion that subjects based their estimates on the recognition of speech sounds rather than other percepts associated with the speech-in-noise conditions such as loudness of the noise. The estimation procedure permits the collection of articulation scores in much less time than required by traditional test procedures.
The Journal of the Acoustical Society of America · Nov 1997
Chaoying Zhang, Fan-Gang Zeng
Abstract
Traditional loudness models have been based on the average energy and the critical band analysis of steady-state sounds. However, most environmental sounds, including speech, are dynamic stimuli, in which the average level [e.g., the root-mean-square (rms) level] does not account for the large temporal fluctuations. The question addressed here was whether two stimuli of the same rms level but different peak levels would produce an equal loudness sensation. A modern adaptive procedure was used to replicate two classic experiments demonstrating that the sensation of "beats" in a two- or three-tone complex resulted in a louder sensation [E. Zwicker and H. Fastl, Psychoacoustics-Facts and Models (Springer-Verlag, Berlin, 1990)]. Two additional experiments were conducted to study exclusively the effects of the temporal envelope on the loudness sensation of dynamic stimuli. Loudness balance was performed by normal-hearing listeners between a white noise and a sinusoidally amplitude-modulated noise in one experiment, and by cochlear implant listeners between two harmonic stimuli of the same magnitude spectra, but different phase spectra, in the other experiment. The results from both experiments showed that, for two stimuli of the same rms level, the stimulus with greater temporal fluctuations sometimes produced a significantly louder sensation, depending on the temporal frequency and overall stimulus level. In normal-hearing listeners, the louder sensation was produced for the amplitude-modulated stimuli with modulation frequencies lower than 400 Hz, and gradually disappeared above 400 Hz, resulting in a low-pass filtering characteristic which bore some similarity to the temporal modulation transfer function. The extent to which loudness was greater was a nonmonotonic function of level in acoustic hearing and a monotonically increasingly function in electric hearing. These results suggest that the loudness sensation of a dynamic stimulus is not limited to a 100-ms temporal integration process, and may be determined jointly by a compression process in the cochlea and an expansion process in the brain. A level-dependent compression scheme that may better restore normal loudness of dynamic stimuli in hearing aids and cochlear implants is proposed.
Hearing Research · Nov 1997
McPartland JL, Culling JF, Moore DR
Abstract
The aim of this study was to determine whether lateralization judgements show adaptation during a period of unilateral ear plugging. Six normally hearing young adults were tested repeatedly using pure tone stimuli of 500 and 4000 Hz to determine (i) the threshold in each ear, (ii) the interaural sensation level difference (ISLD) at which sounds presented alternately to the two ears were of equal loudness, and (iii) the ISLD at which sounds presented simultaneously to the two ears produced a centered internal sound image. Subjects were tested 9-14 times over one week before an ear plug, producing a nominal attenuation of 21 dB (at both frequencies), was placed in one ear. Subjects wore the plug continuously for a further week, and were tested daily during this period, with the plug in place. After unplugging, subjects were tested less frequently for one final week. Net changes in binaural hearing were measured by subtracting the equal loudness ISLD from the centering ISLD. Four subjects showed no net change, either during or after plugging, but a small (< 3 dB) adaptation occurred during plugging in two subjects.