Menu

Single Unit publications

Single-unit and multi-unit spike recordings made with TDT systems.

Clinical and Experimental Otorhinolaryngology · Aug 2026

Effects of Neonatal Deafness on Central Tonotopic Organization in Rats: an Electrophysiological Study (opens in a new tab)

Woongsang Sunwoo, Yeeun Kim

Abstract

Objectives. Spatial mapping of sound frequencies along the auditory pathway is refined through sound-evoked activity during early development. However, how neonatal auditory deprivation alters this organization remains unclear. This study examined frequency-specific spatial representations in the inferior colliculus (IC) using targeted low-frequency (apical) and high-frequency (basal) cochlear stimulation, enabling direct evaluation of low-frequency pathway integrity after neonatal deafness.Methods. Sixteen Sprague-Dawley rats (8 normal-hearing [NH] and 8 neonatally deafened [ND]) were studied. Neonatal deafness was induced by daily kanamycin injections from postnatal days 4 to 17. At 8–10 weeks of age, all animals underwent unilateral cochlear implantation with bipolar electrode pairs positioned in apical and basal cochlear regions to activate low- and high-frequency pathways. Multiunit responses were recorded from the contralateral IC using a multichannel linear electrode array. Spatial tuning curves (STCs) based on cumulative discriminability were used to assess thresholds, spread of excitation, and tonotopic precision. Spiral ganglion neuron (SGN) density was quantified histologically.Results. Despite 48%–67% SGN loss across cochlear turns, electrically evoked auditory brainstem response thresholds and IC thresholds were comparable between groups, indicating preserved peripheral excitability. However, ND rats exhibited significantly broader STCs (P=0.002) and reduced dorsoventral separation of apical and basal best sites (1.18± 0.67 mm vs. 1.80±0.40 mm, P=0.039), reflecting degraded central tonotopic precision. The effects were most pronounced for apical (low-frequency) stimulation, consistent with the selective vulnerability of low-frequency pathways to early auditory deprivation.Conclusion. These findings provide direct physiological evidence that early auditory experience is critical for refining frequency-organized connectivity in the auditory midbrain. The preferential degradation of apical (low-frequency) spatial tuning offers translational insights for optimizing stimulation strategies in early-onset deafness.

Journal of Neural Engineering · Apr 2023

Microneurography as a minimally invasive method to assess target engagement during neuromodulation (opens in a new tab)

Nishant Verma, Bruce Knudsen, Aaron Gholston, … Kip Ludwig

Abstract

Objective. Peripheral neural signals recorded during neuromodulation therapies provide insights into local neural target engagement and serve as a sensitive biomarker of physiological effect. Although these applications make peripheral recordings important for furthering neuromodulation therapies, the invasive nature of conventional nerve cuffs and longitudinal intrafascicular electrodes (LIFEs) limit their clinical utility. Furthermore, cuff electrodes typically record clear asynchronous neural activity in small animal models but not in large animal models. Microneurography, a minimally invasive technique, is already used routinely in humans to record asynchronous neural activity in the periphery. However, the relative performance of microneurography microelectrodes compared to cuff and LIFE electrodes in measuring neural signals relevant to neuromodulation therapies is not well understood. Approach. To address this gap, we recorded cervical vagus nerve electrically evoked compound action potentials (ECAPs) and spontaneous activity in a human-scaled large animal model—the pig. Additionally, we recorded sensory evoked activity and both invasively and non-invasively evoked CAPs from the great auricular nerve. In aggregate, this study assesses the potential of microneurography electrodes to measure neural activity during neuromodulation therapies with statistically powered and pre-registered outcomes ( https://osf.io/y9k6j ). Main results. The cuff recorded the largest ECAP signal ( p < 0.01) and had the lowest noise floor amongst the evaluated electrodes. Despite the lower signal to noise ratio, microneurography electrodes were able to detect the threshold for neural activation with similar sensitivity to cuff and LIFE electrodes once a dose-response curve was constructed. Furthermore, the microneurography electrodes recorded distinct sensory evoked neural activity. Significance. The results show that microneurography electrodes can measure neural signals relevant to neuromodulation therapies. Microneurography could further neuromodulation therapies by providing a real-time biomarker to guide electrode placement and stimulation parameter selection to optimize local neural fiber engagement and study mechanisms of action.