Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

Clinical and Experimental Otorhinolaryngology · Aug 2026

Effects of Neonatal Deafness on Central Tonotopic Organization in Rats: an Electrophysiological Study (opens in a new tab)

Woongsang Sunwoo, Yeeun Kim

Abstract

Objectives. Spatial mapping of sound frequencies along the auditory pathway is refined through sound-evoked activity during early development. However, how neonatal auditory deprivation alters this organization remains unclear. This study examined frequency-specific spatial representations in the inferior colliculus (IC) using targeted low-frequency (apical) and high-frequency (basal) cochlear stimulation, enabling direct evaluation of low-frequency pathway integrity after neonatal deafness.Methods. Sixteen Sprague-Dawley rats (8 normal-hearing [NH] and 8 neonatally deafened [ND]) were studied. Neonatal deafness was induced by daily kanamycin injections from postnatal days 4 to 17. At 8–10 weeks of age, all animals underwent unilateral cochlear implantation with bipolar electrode pairs positioned in apical and basal cochlear regions to activate low- and high-frequency pathways. Multiunit responses were recorded from the contralateral IC using a multichannel linear electrode array. Spatial tuning curves (STCs) based on cumulative discriminability were used to assess thresholds, spread of excitation, and tonotopic precision. Spiral ganglion neuron (SGN) density was quantified histologically.Results. Despite 48%–67% SGN loss across cochlear turns, electrically evoked auditory brainstem response thresholds and IC thresholds were comparable between groups, indicating preserved peripheral excitability. However, ND rats exhibited significantly broader STCs (P=0.002) and reduced dorsoventral separation of apical and basal best sites (1.18± 0.67 mm vs. 1.80±0.40 mm, P=0.039), reflecting degraded central tonotopic precision. The effects were most pronounced for apical (low-frequency) stimulation, consistent with the selective vulnerability of low-frequency pathways to early auditory deprivation.Conclusion. These findings provide direct physiological evidence that early auditory experience is critical for refining frequency-organized connectivity in the auditory midbrain. The preferential degradation of apical (low-frequency) spatial tuning offers translational insights for optimizing stimulation strategies in early-onset deafness.

Nature Electronics · Apr 2026

An implantable epiretinal device for near-infrared light perception (opens in a new tab)

Won Gi Chung, Inhea Jeong, Eun-Joo Lee, … Jang-Ung Park

Abstract

Human vision relies on photoreceptor cells in the outer retina that are sensitive to visible light. However, many people suffer from blindness due to retinal diseases that cause photoreceptor degeneration. Electrical stimulation of retinal neurons can recreate the action potentials associated with seeing that are generated by these cells. Here we report a thin artificial retina that can be adhered to the epiretinal surface and can convert near-infrared (NIR) light into electrical stimuli that selectively stimulate ganglion cells. The artificial retina consists of a NIR-sensitive phototransistor array and three-dimensional liquid metal micropillar electrodes. The liquid metal electrodes enhance proximity to retinal ganglion cells, providing effective charge injection while minimizing tissue damage, owing to their low Young’s modulus. Ex vivo studies demonstrate its biocompatibility, and in vivo studies using healthy and blind mice demonstrate perception of both visible and NIR light, as indicated by cortical recordings and behavioural tests. The retina could, in the future, be used to create a NIR visual channel in patients with photoreceptor degenerative blindness without interfering with their remaining natural vision.

IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2026

Pilot Chronic Evaluation of a Slanted Electrode Array as an Auditory Nerve Implant (opens in a new tab)

W. Mitchel Thomas, Richard K. Gurgel, Loren Rieth, … David J. Warren

Abstract

Objective: The purpose of this paper is to present a chronic, preclinical, pilot study of a multi-electrode auditory nerve implant. To date, the most successful auditory neuroprosthesis is the cochlear implant, but these devices have known limitations. Intraneural stimulation of the auditory nerve is a promising alternative, but preclinical investigations of multi-electrode devices have been limited to acute or semi-chronic studies. Methods: Six cats were chronically implanted in the right auditory nerve with a 15-channel Utah Slant ArrayTM. The array's position in the internal auditory canal was confirmed using computed tomography. Electrode impedance and evoked responses were recorded regularly during the indwelling period to evaluate performance. Results: Two of the six implants met endpoint criteria at 6 months, with stable electrode impedances and robust evoked responses on at least 50% of their channels. Another two implants exhibited stable electrode impedances, but activation thresholds increased over three months. Two implants failed within the first two weeks due to device migration caused by connector-related issues. Conclusion: This study reports the first successful chronic deployment of an multi-electrode auditory nerve implant in a preclinical model. Two implanted cats exhibited stable chronic performance, marked by a consistent set of electrodes capable of eliciting evoked responses. The failure modes of the remaining four cats are discussed and recommendations are made to stabilize implant placement. The study lays a solid foundation for future chronic safety and efficacy investigations as part of an effort to translate this new neuroprosthetic technology into the clinic.

Nature Communications · Dec 2025

Application of kilohertz-frequency block to mitigate off-target motor effects of vagus nerve stimulation in swine (opens in a new tab)

Kevin P. Cheng, Ashlesha Deshmukh, Aaron K. Gholston, … Kip A. Ludwig

Abstract

Selective activation of small versus large diameter nerve fibers represents a broad challenge in the electrical modulation of neural activity for clinical applications. For example, off-target activation of motor nerve fibers was implicated in several failed vagus nerve stimulation (VNS) clinical trials by effectively limiting maximum applicable current amplitudes, thereby preventing robust activation of smaller diameter fibers responsible for therapeutic effects. Kilohertz high-frequency (HF) block is one of several strategies proposed to overcome this gap, but has yet to be thoroughly investigated in large, multifascicular, mixed nerves comparable in scale to humans. Here, we evaluated effects of HF block on the neural, muscular, and cardiac responses evoked by traditional low-frequency (LF) VNS in a large animal (swine) model. We found that HF selectively blocks neural fibers, and their associated physiological responses, in a size dependent manner with a high degree of specificity and establish initial thresholds for achieving block in large multifascicular nerves. Critically, we demonstrate that appropriately titrating HF amplitude can eliminate off-target LF-evoked motor responses while preserving activation of smaller diameter fibers targeted by clinical VNS. Beyond VNS, these data establish HF as a potentially viable strategy in any neuromodulation therapies where off-target activation of large diameter fibers limits therapeutic efficacy.

bioRxiv · Sep 2025

Electrode position, distance, size, and orientation determine efficacy of cervical epidural stimulation to recruit forelimb muscles in rats (opens in a new tab)

Andrés Pascual-Leone, Vishweshwar Tyagi, Ahmet S. Asan, … Jason B. Carmel

Abstract

Target engagement determines therapeutic efficacy. In spinal cord stimulation (SCS), efficacy depends on the attributes of the electrodes used to deliver stimulation, particularly their position, interelectrode distance, size, and current orientation. We tested the effects of these electrode parameters using cervical stimulation to elicit forelimb muscle responses in the rat. We implanted devices over the C6 dorsal root entry zone (DREZ) in eight rats and measured responses in six forelimb muscles. We used custom designed electrode arrays to systematically vary position, distance, and size with linear arrays, and current orientation with circular arrays. Stimulation consisted of biphasic and pseudomonophasic pulse shapes with bipolar or distant return, and a high-definition montage with four returns surrounding a central contact to increase local current density. Efficacy was calculated from the motor thresholds of recruitment curves, and parameters were compared using linear mixed models. For position, stimulation over the DREZ was most effective, reducing thresholds by 25.9% ( p = 0.0002) relative to the midline; efficacy decreased as the electrode was positioned medial or lateral to the DREZ. For distance, placing the electrodes farther apart significantly improved efficacy ( p = 0.0022). For size, large electrodes increased SCS efficacy, reducing thresholds by 21.5% ( p = 0.0026) relative to small electrodes. After accounting for position and distance, current orientation did not affect SCS efficacy. Lastly, the high-definition montage decreased efficacy, increasing thresholds by 16.7% ( p = 0.003) relative to monopolar stimulation with a distant return. In conclusion, electrode position, distance, and size had the greatest effect on SCS efficacy, with the optimal parameters combining large electrodes at the DREZ position with a distant return. These results have the potential to lower the current needed to engage cervical spinal circuitry and to inform the design of SCS systems to improve dexterity in people with neurological injury or disease.

Frontiers in Neurology · Mar 2025

Epineural stimulation on distal brachial plexus for functional restoration of the upper limb in a primate study (opens in a new tab)

Tianfang Yan, Benjamin C. Fortune, Lingjun Liu, … Masayuki Hirata

Abstract

Restoring upper limb function is critical in individuals with central paralysis, and hand control is a priority in patients with neurological impairments. Functional electrical stimulation with implantable electrodes targeting the peripheral nervous system has the potential to selectively recruit hand muscles and generate multiple functional hand movements. However, the implantation of electrodes in the forearm or elbow areas requires multiple incisions for surgery, and elbow joint movements cannot be performed. In this study, we designed and implanted two epineural cuffs on the median and radial nerves in the distal brachial plexus of a single Japanese macaque ( Macaca fuscata ) monkey. The cuffs were successfully placed via an axillary approach using a single incision. Electrical stimuli were applied to innervate the contraction patterns of the hand, forearm, and triceps muscles relevant to the median and radial nerves. The evoked potentials of the target muscles electrically stimulated the distal brachial plexus to reliably and selectively innervate the upper limb muscles at the functional group level. Our results demonstrated that the distal brachial plexus can be a useful stimulation site for upper limb muscle contraction and that the axillary approach enables electrode placement to peripheral nerves required for upper limb control.

Bioelectronic Medicine · Jul 2024

The role of spinal cord neuroanatomy and the variances of epidurally evoked spinal responses (opens in a new tab)

Danny V. Lam, Justin Chin, Meagan K. Brucker-Hahn, … Igor Lavrov

Abstract

Background Spinal cord stimulation (SCS) has demonstrated multiple benefits in treating chronic pain and other clinical disorders related to sensorimotor dysfunctions. However, the underlying mechanisms are still not fully understood, including how electrode placement in relation to the spinal cord neuroanatomy influences epidural spinal recordings (ESRs). To characterize this relationship, this study utilized stimulation applied at various anatomical sections of the spinal column, including at levels of the intervertebral disc and regions correlating to the dorsal root entry zone. Method Two electrode arrays were surgically implanted into the dorsal epidural space of the swine. The stimulation leads were positioned such that the caudal-most electrode contact was at the level of a thoracic intervertebral segment. Intraoperative cone beam computed tomography (CBCT) images were utilized to precisely determine the location of the epidural leads relative to the spinal column. High-resolution microCT imaging and 3D-model reconstructions of the explanted spinal cord illustrated precise positioning and dimensions of the epidural leads in relation to the surrounding neuroanatomy, including the spinal rootlets of the dorsal and ventral columns of the spinal cord. In a separate swine cohort, implanted epidural leads were used for SCS and recording evoked ESRs. Results Reconstructed 3D-models of the swine spinal cord with epidural lead implants demonstrated considerable distinctions in the dimensions of a single electrode contact on a standard industry epidural stimulation lead compared to dorsal rootlets at the dorsal root entry zone (DREZ). At the intervertebral segment, it was observed that a single electrode contact may cover 20-25% of the DREZ if positioned laterally. Electrode contacts were estimated to be ~0.75 mm from the margins of the DREZ when placed at the midline. Furthermore, ventral rootlets were observed to travel in proximity and parallel to dorsal rootlets at this level prior to separation into their respective sides of the spinal cord. Cathodic stimulation at the level of the intervertebral disc, compared to an ‘off-disc’ stimulation (7 mm rostral), demonstrated considerable variations in the features of recorded ESRs, such as amplitude and shape, and evoked unintended motor activation at lower stimulation thresholds. This substantial change may be due to the influence of nearby ventral roots. To further illustrate the influence of rootlet activation vs. dorsal column activation, the stimulation lead was displaced laterally at ~2.88 mm from the midline, resulting in variances in both evoked compound action potential (ECAP) components and electromyography (EMG) components in ESRs at lower stimulation thresholds. Conclusion The results of this study suggest that the ECAP and EMG components of recorded ESRs can vary depending on small differences in the location of the stimulating electrodes within the spinal anatomy, such as at the level of the intervertebral segment. Furthermore, the effects of sub-centimeter lateral displacement of the stimulation lead from the midline, leading to significant changes in electrophysiological metrics. The results of this pilot study reveal the importance of the small displacement of the electrodes that can cause significant changes to evoked responses SCS. These results may provide further valuable insights into the underlying mechanisms and assist in optimizing future SCS-related applications.

Frontiers in Neuroscience · Feb 2024

Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant (opens in a new tab)

W. Mitchel Thomas, Steven A. Zuniga, Inderbir Sondh, … Meredith E. Adams

Abstract

Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.

Nature Nanotechnology · Jan 2024

Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration (opens in a new tab)

Won Gi Chung, Jiuk Jang, Gang Cui, … Jang-Ung Park

Abstract

Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm −2 ) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.

Frontiers in Neurology · Aug 2023

Myogenic and cortical evoked potentials vary as a function of stimulus pulse geometry delivered in the subthalamic nucleus of Parkinson’s disease patients (opens in a new tab)

Brett A. Campbell, Leonardo Favi Bocca, Jakov Tiefenbach, … Kenneth B. Baker

Abstract

Introduction The therapeutic efficacy of deep brain stimulation (DBS) of the subthalamic nucleus (STN) for Parkinson’s disease (PD) may be limited for some patients by the presence of stimulation-related side effects. Such effects are most often attributed to electrical current spread beyond the target region. Prior computational modeling studies have suggested that changing the degree of asymmetry of the individual phases of the biphasic, stimulus pulse may allow for more selective activation of neural elements in the target region. To the extent that different neural elements contribute to the therapeutic vs. side-effect inducing effects of DBS, such improved selectivity may provide a new parameter for optimizing DBS to increase the therapeutic window. Methods We investigated the effect of six different pulse geometries on cortical and myogenic evoked potentials in eight patients with PD whose leads were temporarily externalized following STN DBS implant surgery. DBS-cortical evoked potentials were quantified using peak to peak measurements and wavelets and myogenic potentials were quantified using RMS. Results We found that the slope of the recruitment curves differed significantly as a function of pulse geometry for both the cortical- and myogenic responses. Notably, this effect was observed most frequently when stimulation was delivered using a monopolar, as opposed to a bipolar, configuration. Discussion Manipulating pulse geometry results in differential physiological effects at both the cortical and neuromuscular level. Exploiting these differences may help to expand DBS’ therapeutic window and support the potential for incorporating pulse geometry as an additional parameter for optimizing therapeutic benefit.

Journal of Neural Engineering · Apr 2023

Microneurography as a minimally invasive method to assess target engagement during neuromodulation (opens in a new tab)

Nishant Verma, Bruce Knudsen, Aaron Gholston, … Kip Ludwig

Abstract

Objective. Peripheral neural signals recorded during neuromodulation therapies provide insights into local neural target engagement and serve as a sensitive biomarker of physiological effect. Although these applications make peripheral recordings important for furthering neuromodulation therapies, the invasive nature of conventional nerve cuffs and longitudinal intrafascicular electrodes (LIFEs) limit their clinical utility. Furthermore, cuff electrodes typically record clear asynchronous neural activity in small animal models but not in large animal models. Microneurography, a minimally invasive technique, is already used routinely in humans to record asynchronous neural activity in the periphery. However, the relative performance of microneurography microelectrodes compared to cuff and LIFE electrodes in measuring neural signals relevant to neuromodulation therapies is not well understood. Approach. To address this gap, we recorded cervical vagus nerve electrically evoked compound action potentials (ECAPs) and spontaneous activity in a human-scaled large animal model—the pig. Additionally, we recorded sensory evoked activity and both invasively and non-invasively evoked CAPs from the great auricular nerve. In aggregate, this study assesses the potential of microneurography electrodes to measure neural activity during neuromodulation therapies with statistically powered and pre-registered outcomes ( https://osf.io/y9k6j ). Main results. The cuff recorded the largest ECAP signal ( p < 0.01) and had the lowest noise floor amongst the evaluated electrodes. Despite the lower signal to noise ratio, microneurography electrodes were able to detect the threshold for neural activation with similar sensitivity to cuff and LIFE electrodes once a dose-response curve was constructed. Furthermore, the microneurography electrodes recorded distinct sensory evoked neural activity. Significance. The results show that microneurography electrodes can measure neural signals relevant to neuromodulation therapies. Microneurography could further neuromodulation therapies by providing a real-time biomarker to guide electrode placement and stimulation parameter selection to optimize local neural fiber engagement and study mechanisms of action.

Bioelectronic Medicine · Feb 2023

Characterization and applications of evoked responses during epidural electrical stimulation (opens in a new tab)

Nishant Verma, Ben Romanauski, Danny Lam, … Mingming Zhang

Abstract

Background Epidural electrical stimulation (EES) of the spinal cord has been FDA approved and used therapeutically for decades. However, there is still not a clear understanding of the local neural substrates and consequently the mechanism of action responsible for the therapeutic effects. Method Epidural spinal recordings (ESR) are collected from the electrodes placed in the epidural space. ESR contains multi-modality signal components such as the evoked neural response (due to tonic or BurstDR™ waveforms), evoked muscle response, stimulation artifact, and cardiac response. The tonic stimulation evoked compound action potential (ECAP) is one of the components in ESR and has been proposed recently to measure the accumulative local potentials from large populations of neuronal fibers during EES. Result Here, we first review and investigate the referencing strategies, as they apply to ECAP component in ESR in the domestic swine animal model. We then examine how ECAP component can be used to sense lead migration, an adverse outcome following lead placement that can reduce therapeutic efficacy. Lastly, we show and isolate concurrent activation of local back and leg muscles during EES, demonstrating that the ESR obtained from the recording contacts contain both ECAP and EMG components. Conclusion These findings may further guide the implementation of recording and reference contacts in an implantable EES system and provide preliminary evidence for the utility of ECAP component in ESR to detect lead migration. We expect these results to facilitate future development of EES methodology and implementation of use of different components in ESR to improve EES therapy.

Frontiers in Human Neuroscience · Sep 2022

The impact of pulse timing on cortical and subthalamic nucleus deep brain stimulation evoked potentials (opens in a new tab)

Brett A. Campbell, Leonardo Favi Bocca, David Escobar Sanabria, … Kenneth B. Baker

Abstract

The impact of pulse timing is an important factor in our understanding of how to effectively modulate the basal ganglia thalamocortical (BGTC) circuit. Single pulse low-frequency DBS-evoked potentials generated through electrical stimulation of the subthalamic nucleus (STN) provide insight into circuit activation, but how the long-latency components change as a function of pulse timing is not well-understood. We investigated how timing between stimulation pulses delivered in the STN region influence the neural activity in the STN and cortex. DBS leads implanted in the STN of five patients with Parkinson's disease were temporarily externalized, allowing for the delivery of paired pulses with inter-pulse intervals (IPIs) ranging from 0.2 to 10 ms. Neural activation was measured through local field potential (LFP) recordings from the DBS lead and scalp EEG. DBS-evoked potentials were computed using contacts positioned in dorsolateral STN as determined through co-registered post-operative imaging. We quantified the degree to which distinct IPIs influenced the amplitude of evoked responses across frequencies and time using the wavelet transform and power spectral density curves. The beta frequency content of the DBS evoked responses in the STN and scalp EEG increased as a function of pulse-interval timing. Pulse intervals <1.0 ms apart were associated with minimal to no change in the evoked response. IPIs from 1.5 to 3.0 ms yielded a significant increase in the evoked response, while those >4 ms produced modest, but non-significant growth. Beta frequency activity in the scalp EEG and STN LFP response was maximal when IPIs were between 1.5 and 4.0 ms. These results demonstrate that long-latency components of DBS-evoked responses are pre-dominantly in the beta frequency range and that pulse interval timing impacts the level of BGTC circuit activation.