Menu

Auditory Neurophysiology publications

Recordings from the auditory pathway, from the cochlear nucleus to auditory cortex, with sound presented by TDT systems.

Clinical and Experimental Otorhinolaryngology · Aug 2026

Effects of Neonatal Deafness on Central Tonotopic Organization in Rats: an Electrophysiological Study (opens in a new tab)

Woongsang Sunwoo, Yeeun Kim

Abstract

Objectives. Spatial mapping of sound frequencies along the auditory pathway is refined through sound-evoked activity during early development. However, how neonatal auditory deprivation alters this organization remains unclear. This study examined frequency-specific spatial representations in the inferior colliculus (IC) using targeted low-frequency (apical) and high-frequency (basal) cochlear stimulation, enabling direct evaluation of low-frequency pathway integrity after neonatal deafness.Methods. Sixteen Sprague-Dawley rats (8 normal-hearing [NH] and 8 neonatally deafened [ND]) were studied. Neonatal deafness was induced by daily kanamycin injections from postnatal days 4 to 17. At 8–10 weeks of age, all animals underwent unilateral cochlear implantation with bipolar electrode pairs positioned in apical and basal cochlear regions to activate low- and high-frequency pathways. Multiunit responses were recorded from the contralateral IC using a multichannel linear electrode array. Spatial tuning curves (STCs) based on cumulative discriminability were used to assess thresholds, spread of excitation, and tonotopic precision. Spiral ganglion neuron (SGN) density was quantified histologically.Results. Despite 48%–67% SGN loss across cochlear turns, electrically evoked auditory brainstem response thresholds and IC thresholds were comparable between groups, indicating preserved peripheral excitability. However, ND rats exhibited significantly broader STCs (P=0.002) and reduced dorsoventral separation of apical and basal best sites (1.18± 0.67 mm vs. 1.80±0.40 mm, P=0.039), reflecting degraded central tonotopic precision. The effects were most pronounced for apical (low-frequency) stimulation, consistent with the selective vulnerability of low-frequency pathways to early auditory deprivation.Conclusion. These findings provide direct physiological evidence that early auditory experience is critical for refining frequency-organized connectivity in the auditory midbrain. The preferential degradation of apical (low-frequency) spatial tuning offers translational insights for optimizing stimulation strategies in early-onset deafness.

Frontiers in Neuroscience · Feb 2024

Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant (opens in a new tab)

W. Mitchel Thomas, Steven A. Zuniga, Inderbir Sondh, … Meredith E. Adams

Abstract

Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.