Experimental Physiology · Nov 2025
Laura H Bohórquez, Manuel S Malmierca, Adam Hockley
Abstract
Context‐dependent sensory processing within the predictive coding framework relies on detecting mismatches between incoming stimuli and internal predictive models. Sensory deviants elicit prediction errors, seen as enhanced neural responses, that update these models and influence attention and behaviour. Although prediction errors have been widely observed across brain regions, the downstream processes remain poorly understood. In this study, we recorded electrocorticography in five urethane‐anaesthetised rats and identified cortical slow oscillations, characterised by spontaneous transitions between ‘Up’ and ‘Down’ states. Deviant stimuli in an auditory oddball paradigm evoked an initial positive prediction error, followed by a prolonged, all‐or‐nothing response which spread in a travelling wave across the cortex. Identified as putative evoked cortical Up states, these responses were not evoked by standards, omissions or a many‐standards control. Up states following deviants occurred more recently after a previous Up state when compared to spontaneous Up states. In preliminary data from an awake rat, long‐latency Up states were not present spontaneously or evoked. In a different rat, anaesthetic depth was key to spontaneous and evoked Up states, with more robust Up/Down states and more reliable triggering of Up states under deeper anaesthesia. These results suggest that sensory deviants may cause shifts in cortical state under anaesthesia, explaining the long‐latency mismatch response under anaesthesia and sleep.
Journal of the Association for Research in Otolaryngology · Aug 2025
John C. Middlebrooks, Matthew L. Richardson, Robert P. Carlyon, Harrison W. Lin
Abstract
Purpose Present-day cochlear implants (CIs) can deliver usable speech reception in quiet surroundings. Most CI users, however, show impaired sensitivity to temporal fine structure, which hampers their use of pitch contours and spatial cues to segregate competing talkers. In previous short-term animal studies, we used intraneural (IN) electrodes to stimulate pathways originating from various cochlear turns. Neurons in the inferior colliculus synchronized to apical stimulation at higher rates than to stimulation of the middle-to-basal pathways that are stimulated primarily by today’s CIs. Here, we use non-invasive recordings to test the safety and efficacy of up to 6 months of IN implantation and stimulation in cats. Methods Deafened cats (ten female, two male) were implanted with IN and/or conventional CI electrodes. The IN electrodes were single activated-iridium shanks that targeted apical-turn fibers. Scalp recordings were made from sedated animals at 2–3-week intervals. Auditory brainstem responses to single electrical pulses (eABR) tracked sensitivity and growth of responses. Frequency following responses to electrical pulse trains (eFFR) assessed brainstem temporal transmission at varying pulse rates. Results Thresholds for eABR were lower for IN than for CI stimulation, dynamic ranges were wider, and (by inference) spread of activation was more restricted. The eFFR evaluated at latencies comparable to those of inferior-colliculus spikes synchronized at maximum pulse rates averaging > 360 pulses/s for IN compared to ~ 240 pulses/s for CI stimulation. The eABR thresholds and eFFR cutoff rates were stable out to 6 months after implantation. Conclusions The results demonstrate the safety and efficacy of chronic IN stimulation in an animal model. In a future clinical device, an IN electrode could augment cochlear-implant performance by enhancing temporal acuity, thereby improving speech reception amid competing sounds.
Journal of the Association for Research in Otolaryngology · May 2025
Matthew L. Richardson, Robert P. Carlyon, Harrison W. Lin, John C. Middlebrooks
Abstract
Purpose Present-day cochlear-implant (CI) users can achieve high levels of speech reception in quiet surroundings. Nevertheless, sensitivity to the temporal pitch of sounds is limited, which contributes to deficits in speech reception amid multiple talkers and in appreciation of musical melodies. Short-term, invasive neurophysiological studies in animals have demonstrated limitations in neural phase locking in the tonotopic range of the auditory pathway that is activated by CIs. It remains an open question, however, whether those neural limitations can account for perceptual deficits in those animal species, let alone in human CI users. For that reason, we have evaluated non-invasive recordings of phase locking from cats chronically implanted with a CI. Methods Ten deafened cats (eight female) were implanted with an animal version of a clinical CI array. The electrically evoked frequency following response (eFFRs) was recorded from the scalps of sedated animals at ≥ 10 weeks post-implantation. Stimuli consisted of constant-amplitude electrical pulse trains at rates from ~ 40 to 640 pulses per second. Results Recordings of the eFFR demonstrated robust responses synchronized to electrical pulse trains across all stimulus rates. Analyses of eFFR amplitude and phase transfer functions confirmed that the eFFR, as with its normal-hearing counterpart, originates from multiple subcortical and cortical generators. The slopes of segments of eFFR phase transfer functions revealed stimulus-to-response latencies of generators that dominated the eFFR across restricted ranges of pulse rates. Those rate ranges must coincide with the limits of phase locking by putative generators at successive levels of the auditory neuroaxis and could inform our understanding of the limits to perceptual temporal acuity. Conclusion The eFFR demonstrated here in an animal model provides a valuable non-invasive measure of temporal processing in electric cochlear stimulation that can be related to ongoing perceptual measures in the same animals and is well-suited to evaluate novel modes of auditory prosthesis for enhancing temporal acuity.