Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2026

Pilot Chronic Evaluation of a Slanted Electrode Array as an Auditory Nerve Implant (opens in a new tab)

W. Mitchel Thomas, Richard K. Gurgel, Loren Rieth, … David J. Warren

Abstract

Objective: The purpose of this paper is to present a chronic, preclinical, pilot study of a multi-electrode auditory nerve implant. To date, the most successful auditory neuroprosthesis is the cochlear implant, but these devices have known limitations. Intraneural stimulation of the auditory nerve is a promising alternative, but preclinical investigations of multi-electrode devices have been limited to acute or semi-chronic studies. Methods: Six cats were chronically implanted in the right auditory nerve with a 15-channel Utah Slant ArrayTM. The array's position in the internal auditory canal was confirmed using computed tomography. Electrode impedance and evoked responses were recorded regularly during the indwelling period to evaluate performance. Results: Two of the six implants met endpoint criteria at 6 months, with stable electrode impedances and robust evoked responses on at least 50% of their channels. Another two implants exhibited stable electrode impedances, but activation thresholds increased over three months. Two implants failed within the first two weeks due to device migration caused by connector-related issues. Conclusion: This study reports the first successful chronic deployment of an multi-electrode auditory nerve implant in a preclinical model. Two implanted cats exhibited stable chronic performance, marked by a consistent set of electrodes capable of eliciting evoked responses. The failure modes of the remaining four cats are discussed and recommendations are made to stabilize implant placement. The study lays a solid foundation for future chronic safety and efficacy investigations as part of an effort to translate this new neuroprosthetic technology into the clinic.

Journal of the Association for Research in Otolaryngology · Aug 2025

Chronic Auditory-Nerve Implant Enhances Brainstem Phase Locking to Electric Pulse Trains (opens in a new tab)

John C. Middlebrooks, Matthew L. Richardson, Robert P. Carlyon, Harrison W. Lin

Abstract

Purpose Present-day cochlear implants (CIs) can deliver usable speech reception in quiet surroundings. Most CI users, however, show impaired sensitivity to temporal fine structure, which hampers their use of pitch contours and spatial cues to segregate competing talkers. In previous short-term animal studies, we used intraneural (IN) electrodes to stimulate pathways originating from various cochlear turns. Neurons in the inferior colliculus synchronized to apical stimulation at higher rates than to stimulation of the middle-to-basal pathways that are stimulated primarily by today’s CIs. Here, we use non-invasive recordings to test the safety and efficacy of up to 6 months of IN implantation and stimulation in cats. Methods Deafened cats (ten female, two male) were implanted with IN and/or conventional CI electrodes. The IN electrodes were single activated-iridium shanks that targeted apical-turn fibers. Scalp recordings were made from sedated animals at 2–3-week intervals. Auditory brainstem responses to single electrical pulses (eABR) tracked sensitivity and growth of responses. Frequency following responses to electrical pulse trains (eFFR) assessed brainstem temporal transmission at varying pulse rates. Results Thresholds for eABR were lower for IN than for CI stimulation, dynamic ranges were wider, and (by inference) spread of activation was more restricted. The eFFR evaluated at latencies comparable to those of inferior-colliculus spikes synchronized at maximum pulse rates averaging > 360 pulses/s for IN compared to ~ 240 pulses/s for CI stimulation. The eABR thresholds and eFFR cutoff rates were stable out to 6 months after implantation. Conclusions The results demonstrate the safety and efficacy of chronic IN stimulation in an animal model. In a future clinical device, an IN electrode could augment cochlear-implant performance by enhancing temporal acuity, thereby improving speech reception amid competing sounds.

Journal of the Association for Research in Otolaryngology · May 2025

Frequency Following Responses to Electric Cochlear Stimulation in an Animal Model (opens in a new tab)

Matthew L. Richardson, Robert P. Carlyon, Harrison W. Lin, John C. Middlebrooks

Abstract

Purpose Present-day cochlear-implant (CI) users can achieve high levels of speech reception in quiet surroundings. Nevertheless, sensitivity to the temporal pitch of sounds is limited, which contributes to deficits in speech reception amid multiple talkers and in appreciation of musical melodies. Short-term, invasive neurophysiological studies in animals have demonstrated limitations in neural phase locking in the tonotopic range of the auditory pathway that is activated by CIs. It remains an open question, however, whether those neural limitations can account for perceptual deficits in those animal species, let alone in human CI users. For that reason, we have evaluated non-invasive recordings of phase locking from cats chronically implanted with a CI. Methods Ten deafened cats (eight female) were implanted with an animal version of a clinical CI array. The electrically evoked frequency following response (eFFRs) was recorded from the scalps of sedated animals at ≥ 10 weeks post-implantation. Stimuli consisted of constant-amplitude electrical pulse trains at rates from ~ 40 to 640 pulses per second. Results Recordings of the eFFR demonstrated robust responses synchronized to electrical pulse trains across all stimulus rates. Analyses of eFFR amplitude and phase transfer functions confirmed that the eFFR, as with its normal-hearing counterpart, originates from multiple subcortical and cortical generators. The slopes of segments of eFFR phase transfer functions revealed stimulus-to-response latencies of generators that dominated the eFFR across restricted ranges of pulse rates. Those rate ranges must coincide with the limits of phase locking by putative generators at successive levels of the auditory neuroaxis and could inform our understanding of the limits to perceptual temporal acuity. Conclusion The eFFR demonstrated here in an animal model provides a valuable non-invasive measure of temporal processing in electric cochlear stimulation that can be related to ongoing perceptual measures in the same animals and is well-suited to evaluate novel modes of auditory prosthesis for enhancing temporal acuity.

Frontiers in Neuroscience · Feb 2024

Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant (opens in a new tab)

W. Mitchel Thomas, Steven A. Zuniga, Inderbir Sondh, … Meredith E. Adams

Abstract

Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.

eneuro · 2023

Neonatal Deafening Selectively Degrades the Sensitivity to Interaural Time Differences of Electrical Stimuli in Low-Frequency Pathways in Rats (opens in a new tab)

Woongsang Sunwoo

Abstract

We examined the effect of neonatal deafening on frequency-specific pathways for processing of interaural time differences (ITDs) in cochlear-implant stimuli. Animal studies have demonstrated differences in neural ITD sensitivity in the inferior colliculus (IC) depending on the intracochlear location of intracochlear stimulating electrodes. We used neonatally deafened (ND) rats of both sexes and recorded the responses of single neurons in the IC to electrical stimuli with ITDs delivered to the apical or basal cochlea and compared them with acutely deafened (AD) rats of both sexes with normal hearing (NH) during development. We found that neonatal deafness significantly impacted the ITD sensitivity and the ITD tuning patterns restricted to apically driven IC neurons. In ND rats, the ITD sensitivity of apically driven neurons is reduced to values similar to basally driven neurons. The prevalence of ITD-sensitive apical neurons with a peak-shaped ITD tuning curve, which may reflect predominant input from the medial superior olivary (MSO) complex, in ND rats was diminished compared with that in AD rats (67%, AD vs 40%, ND). Conversely, monotonic-type responses rarely occurred in AD rats (14%) but were approximately equally as prevalent as peak-type tuning curves in ND rats (42%). Nevertheless, in ND rats, the ITD at the maximum slope of the ITD tuning curve was still more concentrated within the physiological ITD range in apically driven than in basally driven neurons. These results indicate that the development of high ITD sensitivity processed by low-frequency pathways depends on normal auditory experience and associated biases in ITD tuning strategies.