TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

Hearing Research · 1998

The influence of disappearing and reappearing spontaneous otoacoustic emissions on one subject’s threshold microstructure (opens in a new tab)

Smurzynski J, Probst R

System IIABR/DPOAE
Abstract

The effects of a consistently disappearing and reappearing spontaneous otoacoustic emission (SOAE) at around 2280 Hz on microstructure for pure tones of varying durations in a 33 year-old woman with normal hearing was studied. The SOAE began to appear after 10-15 min in a quiet test room and increased in level by up to 22 dB over a 30-40-min period. The SOAE was measured every 12 to 15 min. Between measurements, the subject performed a signal detection task for pure tones with total durations varying from 20 to 320 ms. The signal frequencies were within a +/- 30-Hz range relative to the SOAE frequency. For signal durations of 40-320 ms, there was a local dip at the target SOAE frequency when it was either not detectable or its level was lower than -14 dB SPL. Subjective threshold levels were as much as 12 dB better than those obtained when the SOAE was -6 dB SPL or greater. The results suggest that a region of the cochlea with high sensitivity and instability can be put into self-oscillation producing an SOAE, possibly by a change of efferent activity. Hearing threshold is affected possibly due to adaptation or masking.

Journal of Experimental Biology · 1998

Representation of Behaviorally Relevant Sound Frequencies by Auditory Receptors in the Cricket Teleogryllus Oceanicus (opens in a new tab)

Pollack G, z

Abstract

Teleogryllus oceanicus is particularly sensitive to two ranges of sound frequency, one corresponding to intraspecific acoustical signals (4-5 kHz) and the other to the echolocation cries of bats (25-50 kHz). We recorded summed responses of the auditory nerve to stimuli in these two ranges. Nerve responses consist of trains of compound action potentials (CAPs), each produced by the summed activity of a number of receptor neurons. The amplitude of the CAP is up to four times larger for stimuli at 4.5 kHz than for stimuli at 30 kHz, suggesting either that the extracellular spikes produced by receptors that respond to 4.5 kHz are larger than those that respond to 30 kHz, or that receptors fire more synchronously in response to stimulation at 4.5 kHz, or that more receptors respond to stimulation at 4.5 kHz. Neither unit spike amplitude nor conduction velocity (which is expected to vary with spike amplitude) differs for the two frequencies, and the responses to 4.5 kHz are not produced by more tightly synchronized receptor populations, as judged by CAP breadth. We conclude that more receptors respond to 4. 5 kHz than to 30 kHz.

Hearing Research · 1998

Supplemental iron exacerbates aminoglycoside ototoxicity in vivo (opens in a new tab)

Conlon BJ, Smith DW

Abstract

There is increasing evidence to suggest that free radical generation is central to a variety of pathological processes, including drug toxicity. Studies demonstrating the ability of gentamicin to facilitate the generation of radical species suggest that this process plays an important role in aminoglycoside-induced ototoxicity. Because transition metals, particularly iron, play an important role in the production of free radicals and the generation of reactive oxygen species, we sought to determine whether gentamicin-induced ototoxicity is exacerbated by increases in serum iron levels. To this end, we assessed the effects of supplemental iron administration (2 mg/kg/day and 6 mg/kg/day) on changes in auditory function induced by co-administration of gentamicin (100 mg/kg/day for 30 days). Experiments were carried out on pigmented guinea pigs initially weighing 250-300 g. Changes in cochlear function were characterized as shifts in compound action potential (CAP) thresholds, estimated every third day throughout the treatment period by use of chronic indwelling electrodes implanted at the round window, vertex, and contralateral mastoid. Results showed that animals receiving iron in combination with gentamicin demonstrated a more rapid and profound elevation in CAP thresholds compared with animals receiving gentamicin alone. This effect occurred in a dose-dependent manner. Animals receiving supplemental iron alone maintained normal CAP thresholds throughout the treatment period. There was no statistically significant difference in serum gentamicin levels between groups receiving gentamicin alone or gentamicin plus iron. These results provide further evidence of the recently reported intrinsic role of iron in aminoglycoside ototoxicity, and highlight a potential risk of aminoglycoside administration in patients with elevated serum iron.

Journal of the Acoustical Society of Japan (E) · 1998

Random changes in envelope of AM tones and their detection (opens in a new tab)

Edward Ozimek, Jacek Konieczny, Yoiti Suzuki, Toshio Sone

Abstract

The aim of this investigation was to determine the detection thresholds of sinusoidal and random changes in envelope of amplitude modulated (AM) signals. The envelope changes were obtained as a result of modulation of a pure-tone carrier by chosen types of modulators, which gave either sinusoidal, pseudorandom, or random (Gaussian) amplitude modulation. For pseudorandom and random modulation, the detection thresholds were determined when only modulation depth (m) of AM signals was changed randomly (fm const) or when both modulation depth and modulation frequency (fm) were changed randomly (fm random). The data showed that for low modulation frequency (fm≤64Hz) the detection thresholds for sinusoidal amplitude modulation (SAM), pseudorandom amplitude modulation (PAM) and random amplitude modulation (RAM) overlapped one another in the limit of the standard deviation (SD). However, for higher modulation frequencies, the average threshold for the RAM (fm, const) was about 3dB lower (around fm=128Hz) than that for sinusoidal amplitude modulation. In this case the PAM threshold was similar, within the limit of SD, to the SAM threshold. However, when random changes in amplitude were combined with random changes in frequency, the PAM (fm, random), and RAM (fm random) thresholds decreased about 5 dB relative to the SAM threshold.

The Journal of the Acoustical Society of America · Dec 1997

Estimating articulation scores (opens in a new tab)

Rankovic CM, Levy RM

Abstract

The ability of listeners to estimate articulation scores for lists of nonsense syllables was evaluated. Normal-hearing subjects were presented with lists of from 50 to 60 nonsense syllables that were degraded with various amounts of noise or filtering and were instructed to estimate consonant-correct scores for each condition. To provide a reference for estimating, subjects were shown the accurate orthographic representation of the syllable on a computer monitor to compare with the auditory presentation. The printed version was displayed either simultaneously with the auditory presentation or 500 ms after the offset of the syllable. Estimates were collected on two occasions to examine test-retest reliability, and actual percent-correct scores were obtained to check the accuracy of the estimates. Most subjects overestimated actual scores when the printed representation was provided simultaneously, but estimates were strikingly similar to actual scores when the printed representation was delayed. The delay appeared to prevent the printed representation from favorably biasing the reception of the syllable. The average of two or three estimates gave highly repeatable results for both visual displays. Crossover frequencies derived from the filtered-speech conditions were within the range reported in the literature. This supports the conclusion that subjects based their estimates on the recognition of speech sounds rather than other percepts associated with the speech-in-noise conditions such as loudness of the noise. The estimation procedure permits the collection of articulation scores in much less time than required by traditional test procedures.

The Journal of the Acoustical Society of America · Nov 1997

Loudness of dynamic stimuli in acoustic and electric hearinga (opens in a new tab)

Chaoying Zhang, Fan-Gang Zeng

Abstract

Traditional loudness models have been based on the average energy and the critical band analysis of steady-state sounds. However, most environmental sounds, including speech, are dynamic stimuli, in which the average level [e.g., the root-mean-square (rms) level] does not account for the large temporal fluctuations. The question addressed here was whether two stimuli of the same rms level but different peak levels would produce an equal loudness sensation. A modern adaptive procedure was used to replicate two classic experiments demonstrating that the sensation of "beats" in a two- or three-tone complex resulted in a louder sensation [E. Zwicker and H. Fastl, Psychoacoustics-Facts and Models (Springer-Verlag, Berlin, 1990)]. Two additional experiments were conducted to study exclusively the effects of the temporal envelope on the loudness sensation of dynamic stimuli. Loudness balance was performed by normal-hearing listeners between a white noise and a sinusoidally amplitude-modulated noise in one experiment, and by cochlear implant listeners between two harmonic stimuli of the same magnitude spectra, but different phase spectra, in the other experiment. The results from both experiments showed that, for two stimuli of the same rms level, the stimulus with greater temporal fluctuations sometimes produced a significantly louder sensation, depending on the temporal frequency and overall stimulus level. In normal-hearing listeners, the louder sensation was produced for the amplitude-modulated stimuli with modulation frequencies lower than 400 Hz, and gradually disappeared above 400 Hz, resulting in a low-pass filtering characteristic which bore some similarity to the temporal modulation transfer function. The extent to which loudness was greater was a nonmonotonic function of level in acoustic hearing and a monotonically increasingly function in electric hearing. These results suggest that the loudness sensation of a dynamic stimulus is not limited to a 100-ms temporal integration process, and may be determined jointly by a compression process in the cochlea and an expansion process in the brain. A level-dependent compression scheme that may better restore normal loudness of dynamic stimuli in hearing aids and cochlear implants is proposed.

Hearing Research · Nov 1997

Changes in lateralization and loudness judgements during one week of unilateral ear plugging (opens in a new tab)

McPartland JL, Culling JF, Moore DR

Abstract

The aim of this study was to determine whether lateralization judgements show adaptation during a period of unilateral ear plugging. Six normally hearing young adults were tested repeatedly using pure tone stimuli of 500 and 4000 Hz to determine (i) the threshold in each ear, (ii) the interaural sensation level difference (ISLD) at which sounds presented alternately to the two ears were of equal loudness, and (iii) the ISLD at which sounds presented simultaneously to the two ears produced a centered internal sound image. Subjects were tested 9-14 times over one week before an ear plug, producing a nominal attenuation of 21 dB (at both frequencies), was placed in one ear. Subjects wore the plug continuously for a further week, and were tested daily during this period, with the plug in place. After unplugging, subjects were tested less frequently for one final week. Net changes in binaural hearing were measured by subtracting the equal loudness ISLD from the centering ISLD. Four subjects showed no net change, either during or after plugging, but a small (< 3 dB) adaptation occurred during plugging in two subjects.

Hearing Research · Nov 1997

Diversity in frequency response properties of saccular afferents of the toadfish, Opsanus tau (opens in a new tab)

Fay RR, Edds-Walton PL

Abstract

The frequency response of primary saccular afferents of toadfish (Opsanus tau) was studied in the time and frequency domains using the reverse correlation (revcor) method. Stimuli were noise bands with flat acceleration spectra delivered as whole-body motion. The recorded acceleration waveform was averaged over epochs preceding and following each spike. This average, termed the revcor, is an estimate of the response of an equivalent linear filter intervening between body motion and spike initiation. The spectrum of the revcor estimates the shape of the equivalent linear filter. Revcor responses were brief, damped oscillations indicative of relatively broadly tuned filters. Filter shapes were generally band-pass and differed in bandwidth, band edge slope, and characteristic frequency (74 Hz to 140 Hz). Filter shapes tend to be independent of stimulus level. Afferents can be placed into two groups with respect to characteristic frequency (74-88 Hz and 140 Hz). Some high-frequency afferents share a secondary peak at the characteristic frequency of low-frequency afferents, suggesting that an afferent may receive differently tuned peripheral inputs. For some afferents having similar filter shapes, revcor responses often differ only in polarity, probably reflecting inputs from hair cells oriented in opposite directions. The origin of frequency selectivity and its diversity among saccular afferents may arise from a combination of hair cell resonance and micromechanical processes. The resulting frequency analysis is the simplest yet observed among vertebrate animals. During courtship, male toadfish produce the 'boatwhistle' call, a periodic vocalization having several harmonics of a 130 Hz fundamental frequency. The saccule encodes the waveform of acoustic particle acceleration between < 50 and about 250 Hz. Thus, the fundamental frequency component of the boatwhistle is well encoded, but the successive higher harmonics are filtered out. The boatwhistle is thus encoded as a time-domain representation of its fundamental frequency or pulse repetition rate.

The Journal of the Acoustical Society of America · Oct 1997

Identification of multidimensional stimuli containing speech cues and the effects of training (opens in a new tab)

Christensen LA, Humes LE

Abstract

The purpose of this study was to determine how listeners with normal hearing make use of cues from multiple, independent stimulus dimensions when classifying synthesized stimuli containing acoustic cues found in speech. Listeners classified synthesized stimuli that differed on three independent and discriminable dimensions. The three dimensions of the stimuli included: (1) the fricative spectrum center frequency; (2) the slope of the frequency transition; and (3) the duration of the temporal gap. Each of the three dimensions could take on one of three possible values. Twenty-seven stimuli were synthesized using all possible combinations of the values on the three dimensions. Multidimensional scaling of paired-comparison similarity judgments confirmed the existence of three perceptual dimensions. Listeners were then trained to classify three exemplar stimuli as "circle," "triangle," and "square," respectively. Following this training, subjects classified all 27 stimuli as "circle," "triangle," and "square." From this it was determined how each listener's attention was distributed among the dimensions. Results indicated the listeners did not pay equal attention to the three stimulus dimensions. In addition, it was demonstrated that it was possible to train a listener to attend to a dimension that was not previously used to classify the stimuli.

The Journal of the Acoustical Society of America · Oct 1997

Effects of electrode configuration on psychophysical strength-duration functions for single biphasic electrical stimuli in cats (opens in a new tab)

Smith DW, Finley CC

Abstract

The interface between electrode and neural target tissue is thought to influence certain characteristics of neural and behavioral responses to electrical stimulation of the auditory system. At present, the biophysical properties of this interface are not well understood. Here the effects of biphasic phase duration and electrode configuration on psychophysical threshold in response to electrical stimulation in cats are described. Five cats were trained to respond to acoustic stimuli using food as a reward in an operant reinforcement paradigm. After training, the animals were unilaterally deafened and implanted with a multicontact intracochlear electrode array. Thresholds for single presentations of biphasic current pulses were measured as a function of phase duration and electrode arrangement. Statistical analyses of the data indicated that strength-duration function slopes between 200 and 1600 microseconds/phase were significantly different for the different electrode configurations and, overall, were unrelated to the absolute level of the strength-duration function (i.e., were independent of absolute threshold). For all subjects, the slope of this function for intermediate pulse durations was dependent on electrode configuration and most shallow for radial-bipolar configurations (-3.4 dB/doubling), was steepest for monopolar arrangements (-5.9 dB/doubling), and was intermediate for longitudinal-bipolar pairings. (-4.4 dB/doubling). Slopes for both shorter and longer phase duration stimuli were not significantly different. The underlying mechanisms for these effects may include, or be a combination of altered electrical field patterns, integrated activity across multiple fibers, and stochastic behavior of individual auditory neurons to electrical stimulation.

Journal of the American Academy of Audiology · Oct 1997

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions. (opens in a new tab)

Chertoff ME, Guruprasad SN

AP2DA2PA4ABR/DPOAE
Abstract

This study examined the influence of a calibrated transient stimulus on click evoked otoacoustic emissions (CEOAEs). The calibration procedure produced a spectrally uniform stimulus (1-8 kHz) at the plane of the ear probe that was very similar among individuals. However, the calibrated signal reduced the overall level and repeatability of the CEOAE, probably due to the minimization of the energy peak at 2 kHz, which is enhanced in the uncalibrated signal. The amplitude of CEOAEs obtained with the calibrated signal was less variable among individuals compared to CEOAEs obtained with the uncalibrated signal.

Hearing Research · Sep 1997

Directional response properties of saccular afferents of the toadfish, Opsanus tau (opens in a new tab)

Fay RR, Edds-Walton PL

Abstract

The displacement sensitivity, frequency response, and directional response properties of primary saccular afferents of toadfish (Opsanus tau) were studied in response to a simulation of acoustic particle motion for which displacement magnitudes and directions were manipulated in azimuth and elevation. Stimuli were 50, 100, and 200 Hz sinusoidal, translatory oscillations of the animal at various axes in the horizontal and midsagittal planes. Thresholds in these planes defined a cell's characteristic axis (the axis having the lowest threshold) in spherical coordinates. Recordings were made from afferents in rostral, middle, and caudal bundles of the saccular nerve. The most sensitive saccular afferents responded with a phase-locked response to displacements as small as 0.1 nm. This sensitivity rivals that of the mammalian cochlea and is probably common to the sacculi and other otolith organs of most fishes. Most afferents showed lower thresholds at 100 Hz than at 50 or 200 Hz. Eighty percent of afferents have three-dimensional directional properties that would be expected if they innervated a group of hair cells having the same directional orientation on the saccular epithelium. Of the afferents that are not perfectly directional, most appear to innervate just two groups of hair cells having different orientations. The directional characteristics of afferents are qualitatively correlated with anatomically defined patterns of hair cell orientation on the saccule. In general, azimuths of best sensitivity tend to lie parallel to the plane of the otolith and sensory epithelium. Elevations of best sensitivity correspond well with hair cell orientation patterns in different regions of the saccular epithelium. Directional hearing in the horizontal plane probably depends upon the processing of interaural differences in overall response magnitude. These response differences arise from the gross orientations of the sacculi and are represented, in part, as time differences among nonspontaneous afferents that show level-dependent phase angles of synchronization. Directional hearing in the vertical plane may be derived from the processing of across-afferent profiles of activity within each saccule. Fishes were probably the first vertebrates to solve problems in sound source localization, and we suggest that their solutions formed a model for those of their terrestrial inheritors.

Ear & Hearing · Aug 1997

Subjective judgments of speech clarity measured by paired comparisons and category rating (opens in a new tab)

Eisenberg LS, Dirks DD, Gornbein JA

Abstract

Objective The purpose of this study was to compare listeners' subjective judgments of speech clarity via paired comparisons and category rating using stimulus conditions that varied in the relative spacing between stimulus items, producing either a wide or narrow range of performance. Design Subjective judgments of speech clarity were measured via paired comparisons and category rating in 12 normal-hearing (Experiment 1) and eight hearing-impaired adults (Experiment 2). Sentences processed by six band-pass filters that increased monotonically in Articulation Index (AI) estimates constituted the stimuli to be judged. Using subsets of three filters from the group of six, subjective judgments were additionally obtained for stimulus conditions in which the performance ranges were wide (large differences in AI) and narrow (small differences in AI). Results Speech clarity judgments obtained by paired comparisons and category rating were highly related to the AI estimates both for normal-hearing and hearing-impaired subjects. When the performance range was wide, both methods provided similar judgments for the normal-hearing subjects. For the hearing-impaired subjects, paired comparisons were more sensitive than category rating. When the performance range was narrow, paired comparisons were more sensitive than category rating in differentiating between filters for both groups of subjects. This difference was less obvious for the normal-hearing subjects when paired comparison data were converted to a scale comparable to the category ratings. Large between-subject variability was evident for the hearing-impaired subjects on the psychophysical scaling procedures, most notably for category rating. Conclusions When judging the clarity among stimulus items where performance varied over a wide range, both category rating and paired comparisons provided comparable judgments for normal-hearing listeners. For conditions in which perceptual differences between stimulus items were restricted either by the choice of conditions or by the effects of sensorineural hearing loss, the method of paired comparisons was the more sensitive procedure.