TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

Hearing Research · May 1994

Monaural sound localization: acute versus chronic unilateral impairment (opens in a new tab)

Slattery WH 3rd, Middlebrooks JC

Abstract

We tested the ability of human listeners to localize broadband noise bursts in the absence of binaural localization cues. The subject population consisted of five patients, who had normal hearing in one ear and congenital deafness in the other, and seven normal controls, who were tested with both ears open and with one ear plugged. Consistent with previous reports, the introduction of an ear plug unilaterally into control subjects resulted in a prominent lateral displacement in their localization judgements by an average of 30.9 degrees toward the side of the open ear. Vertical localization was less strongly impaired. The five monaural patients showed a considerable range of ability to localize sounds. Two of the patients were essentially indistinguishable from the plugged control subjects in that they showed a prominent displacement of responses toward the side of the hearing ear. The other three subjects localized significantly better than the plugged controls, in that they demonstrated little or no lateral displacement toward the hearing side and that they localized targets on the hearing and on the impaired sides about equally well. The performance of these latter patients demonstrates that monaural cues can provide useful localization information in the horizontal as well as in the vertical dimension.

Otolaryngology · 1994

Covariation of tinnitus pitch and the associated emission: A case study (opens in a new tab)

Penner MJ, Glotzbach L

Abstract

Tinnitus in one female subject was found to be related to numerous (as many as 21) bilateral spontaneous otoacoustic emissions. The association of tinnitus and spontaneous otoacoustic emissions was empirically supported by the masking/suppression demonstration. The subject reported that her tinnitus occurred primarily in her right ear, which had linked, quasi-stable spontaneous otoacoustic emissions not found contralaterally. During one menstrual cycle, a pure tone was adjusted to match the predominant tinnitus pitch. The frequency of the tone generally followed the day-to-day shifts in the frequency of the associated spontaneous otoacoustic emission. The frequencies of these tones were a local minimum near the onset of menstruation, reaching a local maximum after menstruation.

Le Journal de Physique IV · 1994

Système efférent, masquage central et perception dans le bruit (opens in a new tab)

C. MICHEYL, L. COLLET

Abstract

In order to investigate the role of the auditory efferents in perception, the controlateral suppression of evoked otoacoustic emissions (EOAEs) was examined together with 1) central masking and 2) detection in noise in normal hearing subjects. The first study, concerning the relations between the contralateral suppression of EOAEs and central masking at 1 kHz, put into evidence the existence of a significant negative correlation between the amount of central masking obtained with a delay of 20 ms between the test and the mask and the modifications of the amplitude of EOAEs induced around 1 kHz by a contralateral 30 dBSL broadband noise stimulation. In the second study, a correlation was found between the mean equivalent attenuation of EOAEs and the variation of the tone-in-noise detection threshold, both induced by a contralateral 30 dBSL broadband noise stimulation. These results support the hypothesis that the crossed part of the medial olivo-cochlear system is actually involved in auditory perception in humans.

The Journal of the Acoustical Society of America · Nov 1992

Narrow‐band sound localization related to external ear acoustics (opens in a new tab)

Middlebrooks JC

Abstract

Human subjects localized brief 1/6-oct bandpassed noise bursts that were centered at 6, 8, 10, and 12 kHz. All testing was done under binaural conditions. The horizontal component of subjects' responses was accurate, comparable to that for broadband localization, but the vertical and front/back components exhibited systematic errors. Specifically, responses tended to cluster within restricted ranges that were specific for each center frequency. The directional transfer functions of the subjects' external ears were measured for 360 horizontal and vertical locations. The spectra of the sounds that were present in the subjects' ear canals, the "proximal stimulus" spectra, were computed by combining the spectra of the narrow-band sound sources with the directional transfer functions for particular stimulus locations. Subjects consistently localized sounds to regions within which the associated directional transfer function correlated most closely with the proximal stimulus spectrum. A quantitative model was constructed that successfully predicted subjects' responses based on interaural level difference and spectral cues. A test of the model, using techniques adapted from signal detection theory, indicated that subjects tend to use interaural level difference and spectral shape cues independently, limited only by a slight spatial correlation of the two cues. A testing procedure is described that provides a quantitative comparison of various predictive models of sound localization.

Hearing Research · 1992

Methods for detecting auditory steady-state potentials recorded from humans (opens in a new tab)

Craig A Champlin

PA3QDAIABR/DPOAE
Abstract

Auditory steady-state potentials were recorded from the scalp of adult humans. The stimuli were 100-microseconds clicks presented at a rate of 39.1/s. Four stimulus levels were used (-20, 0, 10, and 20 dB SL). The presence or absence of a response was determined by three frequency-domain methods and examiners. The frequency-domain methods were: magnitude-squared coherence (MSC), phase coherence (PC), and magnitude only (MO). The MSC method generally had the highest d' values, indicating that it was the most sensitive method for detecting responses. The hearing threshold predicted by the MSC method was the lowest, and it was within 4 dB of the behaviorally measured threshold for the click stimuli. Further, the amplitude of the response was significantly more variable than its phase, and no relation was found between the variability of the amplitude of the response and the amplitude of the noise. In summary, response detection methods that incorporate phase information (such as MSC and PC) should be chosen over methods which incorporate only amplitude information.