TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

Journal of Speech and Hearing Research · Oct 1995

Reliability and sensitivity of paired comparisons and category rating in children (opens in a new tab)

Eisenberg LS, Dirks DD

Abstract

Children's subjective judgments of speech clarity using the methods of paired comparisons and category rating were evaluated in this investigation. Eighty children with normal hearing between the ages of 4 and 8 years judged the clarity of sentences that were systematically bandpass-filtered using conditions that increased intelligibility as estimated by the Articulation Index. Subjects were classified into four age groups (4-, 5-, 6-, and 7-8-year age groups) with 20 subjects per group. With use of materials and training methods suitable for children, judgments were obtained via the two psychophysical procedures (10 subjects per age group for each procedure). Results indicated that children 5 years of age and older were able to make reliable clarity judgments using either procedure; however, the method of paired comparisons was more sensitive than category rating in detecting differences between the bandpass-filtered conditions.

Hearing Research · Oct 1995

Combination-sensitive neurons in the inferior colliculus (opens in a new tab)

Mittmann DH, Wenstrup JJ

Abstract

We examined whether neurons in the inferior colliculus of the mustached bat (Pteronotus parnellii) are combination sensitive, responding to both low- and high-frequency components of the bat's sonar signal. These neurons, previously reported in the thalamus and cortex, analyze sonar target features including distance. Of 82 single units and 36 multiple units from the 58-112 kHz representations of the inferior colliculus, most (86%) displayed sensitivity to low-frequency sounds that was tuned in the range of the fundamental biosonar component (24-31 kHz). All histologically localized units were in the central nucleus of the inferior colliculus (ICC). There were two major types of combination-sensitive influences. Many neurons were facilitated by low-frequency sounds and selective for particular delays between the low- and high-frequency components. In other neurons, the low-frequency signal was inhibitory if presented simultaneously or a few milliseconds prior to the high-frequency signal. The results indicate that mechanisms creating specialized frequency comparisons and delay sensitivity in combination-sensitive neurons operate at the ICC or below. Since combination sensitivity or multipeaked tuning curves occur in the auditory systems of many species, ICC neurons in these animals may also respond to species-specific frequency combinations.

The Journal of the Acoustical Society of America · Sep 1995

The effects of sinusoidal amplitude modulation on gap detection in noise (opens in a new tab)

Snell KB

Abstract

The purpose of this study was to investigate the effects of envelope fluctuation on temporal gap detection. Temporal gap detection thresholds were measured in wideband noisebursts that had been amplitude modulated by a very low-frequency sinusoid. Detection was studied at six modulation depths and in four phase conditions which placed the onset of the silent gap at different amplitudes on the temporal envelope of the waveform. Gap thresholds were obtained in a 3IFC paradigm in four young, normal-hearing subjects. The smallest mean gap threshold, 3.5 ms, was obtained for unmodulated noisebursts. The largest mean gap threshold, 25.7 ms, was obtained at a modulation depth of 100%. Phase did not significantly affect gap detection until modulation depth was increased to 40%. At deeper depths of modulation, gap thresholds were smallest, but also most variable, when the gap onset was placed at a peak in the waveform envelope and largest when the gaps were centered on an envelope minimum or randomly placed. Results of this study are consistent with previous findings and the hypothesis that gap detection is dependent on the similarity of the gap itself to inherent fluctuations in the stimulus envelope, reflecting coherence in terms of phase and depth of envelope fluctuation.

Audiology · Jul 1995

Reliability of auditory brainstem responses from sequenced high-frequency (≥ 8 kHz) tonebursts (opens in a new tab)

Fausti SA, Mitchell CR, Frey RH, … Phillips DS

Abstract

An auditory brainstem response method is described for evoking responses to 4 high-frequency (8, 10, 12 and 14 kHz) tonebursts in the same amount of time normally required to obtain responses to single tonebursts. Reliability of responses to high-frequency toneburst stimuli presented in the conventional manner (one at a time) has been previously documented. In the present study, high-frequency tonebursts were presented to 20 normal-hearing subjects singly and in a 4-stimulus sequence. The reliability of resulting responses did not differ significantly between single- and multiple-stimulus test conditions. It is concluded that this sequenced-stimulus concept could be developed for use in serial monitoring of individuals receiving ototoxic agents as well as being broadly applicable to clinical situations in which patients cannot or will not respond voluntarily.

The Journal of the Acoustical Society of America · Jul 1995

Behavioral auditory thresholds for sinusoidal electrical stimuli in the cat (opens in a new tab)

Smith DW, Watt S, Konrad KE, Olszyk VB

Abstract

Behavioral thresholds were measured in four cats by training them to respond behaviorally to acoustic auditory stimuli using food as a reward in an operant reinforcement paradigm. Following training, the subjects were implanted unilaterally with either a scaled-UCSF electrode containing four contacts or an electrode array containing eight intracochlear contacts and one extracochlear contact under temporalis muscle. Behavioral thresholds for electrical stimuli were obtained as a function of sinusoidal frequency, duration, and electrode configuration. Threshold functions for both electrode types and all animals had minima between 48 and 125 Hz and, in general, were relatively flat below this minima; functions increased at 3-6 dB/octave from 96 Hz to 1 kHz. Threshold varied predictably as a function of electrode configuration, with thresholds decreasing as much as 20 dB as electrode spacing was widened from a radial bipolar (200-microns separation) to a monopolar configuration (apical stimulating and temporalis return). With long-duration stimuli, increasing the electrode separation systematically increased the slope of the threshold-versus-frequency contours in all animals. Irrespective of electrode type or configuration, charge/phase thresholds for single-cycle sinusoids were relatively flat for stimulus periods up to 1-5 ms, approximating a constant charge/phase determination of threshold. At phase durations greater than 5 ms, charge thresholds increased at a rate slightly above 6 dB/octave (constant peak current), which was suggestive of neural accommodation. Thresholds for the cat share many features with those reported for implanted humans and monkeys.

The Journal of the Acoustical Society of America · May 1995

Within‐and across‐channel processes in modulation detection interference (opens in a new tab)

Mendoza L, Hall JW 3rd, Grose JH

Abstract

Modulation detection interference (MDI) describes the effect of an amplitude-modulated sound on detection of amplitude modulation (AM) on a spectrally distant target sound. In MDI, AM detection is worsened by an AM interfering sound. Previous research has implicated both within-channel and across-channel processes as the basis for MDI. This study examined the detection of 10-Hz sinusoidal AM as a function of the spectral relationship, gating synchrony, and ear of presentation of the target and interfering sounds. Using a 993-Hz target sound, AM detection improved as the frequency of the interferer increased from 1250 to 2188 Hz, and as it decreased from 788 to 450 Hz. MDI was less for continuous interferers than for interferers gated synchronously with the target. In the continuous interferer conditions, however, MDI was still greatest for interferers most proximal to the target. The effects of frequency proximity and gating asynchrony were also evident using interferers presented to the ear contralateral to the target ear. While a 1250-Hz interferer led to more MDI than a 788-Hz interferer when the interferers were presented to the same ear as a 993-Hz target, no significant asymmetry was noted with dichotic stimulation. Taken together, the results of these experiments indicated that MDI is the result of across-channel, and to a limited extent, within-channel processes.

The Journal of the Acoustical Society of America · Apr 1995

Masked thresholds and consonant recognition in low‐pass maskers for hearing‐impaired and normal‐hearing listeners (opens in a new tab)

Dubno JR, Ahlstrom JB

Abstract

Thresholds and consonant recognition were measured in six low-pass maskers as a function of masker bandwidth for hearing-impaired subjects and for normal-hearing subjects listening in spectrally shaped broadband noise (SSBB). SSBB was adjusted such that thresholds in that masker for a normal-hearing listener were equal to a hearing-impaired listener's absolute thresholds. Thresholds measured in low-pass maskers were higher for hearing-impaired than for normal-hearing subjects for signal frequencies both within and outside masker passbands, although threshold differences were larger for signal frequencies outside masker passbands. Slopes of functions relating consonant recognition to speech level were not significantly different between groups, due to the presence of SSBB for the normal-hearing listeners. However, 25% of observed scores for hearing-impaired listeners, compared to only 5% of observed scores for normal-hearing listeners, were significantly poorer than predicted by the articulation index (AI), when AIs were computed using subjects' absolute thresholds. Better correspondence between observed and predicted scores in low-pass maskers was achieved when AIs were derived empirically from thresholds measured in each low-pass masker. Hence poorer-than-predicted consonant recognition scores in low-pass maskers were accounted for by higher-than-normal thresholds in those maskers.

Acta Oto-Laryngologica · Mar 1995

Contralateral suppression of evoked otoacoustic emissions and detection of a multi-tone complex in noise (opens in a new tab)

Micheyl C, Morlet T, Giraud AL, … Morgon A

Abstract

Although some findings suggest that auditory efferent fibers are involved in perception in noise, their function remains controversial. The contralateral suppression of evoked otoacoustic emissions (EOAEs) has recently provided a means of exploring the medial olivocochlear system (MOCS) in humans. In an experiment based on this paradigm, the present study examined the relationships between variations of both EOAEs and detection-in-noise thresholds, induced in the same subjects by a contralateral 50-dB-SPL broad-band noise masker. EOAEs were recorded in response to a burst of a multitone complex composed of 1, 1.5 and 2-kHz components. The detection thresholds of this 3-component complex were measured at 2 ipsilateral noise levels: 50 and 70 dB SPL. The main finding was a significant correlation between EOAE suppression and threshold variations under contralateral masking. A relationship was also found between the contralateral suppression of EOAEs and threshold variation induced by the increase in ipsilateral noise level. These findings support the notion that the MOCS is involved in the detection of multicomponent stimuli in noise.

Hearing Research · Feb 1995

Nonlinear mechanics at the apex of the guinea-pig cochlea (opens in a new tab)

Cooper NP, Rhode WS

Abstract

A heterodyne laser interferometer was used to observe the sound-evoked displacement patterns of Reissner's membrane and various other structures in the apical turn of the guinea-pig cochlea. Most structures (including the basilar membrane) were similarly tuned, and had best frequencies in the 200-350Hz range. A distinct notch was usually observed approximately 0.7 octaves above the best frequency, and amplitude- and phase-plateaus were observed at higher frequencies. In most other respects, however, the mechanical tuning resembled the frequency-threshold curves of low frequency cochlear nerve fibers. In five reasonably intact, in vivo preparations, the frequency of the mechanical sensitivity notch was intensity-dependent: Compressive nonlinearities were observed above approximately 80 dB SPL on the low-frequency side of the notch, with antagonistically expansive nonlinearities on the high-frequency side. Two-tone suppression was observed in one of these preparations. Stimulus-related baseline position shifts were observed in another in vivo preparation. No such nonlinearities were observed in structurally damaged and/or > 1 hour post-mortem preparations. However, more robust nonlinearities were observed in all preparations at higher levels of stimulation (e.g. > 100-110 dB SPL). These high-level nonlinearities diminished only slowly after death, and gave rise to various effects, including time-dependent (i.e. adapting) and severely distorted (e.g. peak-split and/or dc-shifted) responses.

Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 1995

Auditory icons as warning and advisory signals in the US Army Battlefield Combat Identification System (BCIS) (opens in a new tab)

Ellen Haas, Jeffrey Schmidt

Abstract

The U.S. Army proposed the Battlefield Combat Identification System (BCIS) to diminish fratricide by providing five critical auditory and visual warning signals. The purpose of this experiment was to determine whether the auditory warning signals designed by the U.S. Army Human Research and Engineering Directorate (HRED) provided greater user association with the BCIS signal functions than did signals designed by a contractor. The contractor signals consisted of pure tones, while the HRED signals were auditory icons designed with intent to provide a high level of user association. The dependent variable was the subject's free-modulus magnitude estimation rating of the degree of association of the signal with the signal function. Subjects were 20 male U.S. Army Infantrymen. Data were analyzed using t-tests for paired samples. Results indicated that the mean perceived association was significantly greater for the HRED auditory icons in one of five cases, and greater (but not significantly so) in two additional cases. There were no other significant differences. Implications for auditory display design are discussed.

Hearing Research · Dec 1994

Behavioral and electrophysiological responses to electrical stimulation in the cat: I. Absolute thresholds (opens in a new tab)

Smith DW, Finley CC, van den Honert C, … Konrad KE

Abstract

Estimates of electrical auditory brainstem response (EABR) thresholds are compared with behavioral thresholds for electrical stimulation in the same subject using identical stimuli and electrode configurations. Four cats were behaviorally trained to measure acoustic auditory thresholds using food as a reward in an operant reinforcement paradigm. One of the animals was then implanted, in an otherwise normal ear, with a scaled-UCSF multi-contact electrode array containing four intracochlear electrodes. Three animals were implanted with an electrode array containing eight intracochlear contacts and one extracochlear contact under the temporalis muscle following unilateral cochlear perfusion with 10% neomycin solution. Stimuli for the behavioral studies were single presentations of 200 us/phase biphasic current pulses. For the EABR studies, the same stimulus was presented at a rate of 32/s. In general, for the animal with the four-contact array and two of the three subjects with the eight-contact implant, changes in electrode configuration produced well-differentiated changes in threshold. For these three subjects, comparisons of behavioral and EABR thresholds for the majority of monopolar and bipolar electrode configurations tested showed excellent agreement (r2 = 0.88). Correlations between behavioral and EABR measures in these animals were comparable for bipolar and monopolar arrangements (r2 = 0.88 for bipolar and 0.87 for monopolar). For one subject with the eight-contact electrode, who showed similar monopolar and bipolar electrode behavioral thresholds for all tested electrode spacings or configurations, most EABR thresholds were substantially higher than, and poorly correlated with, behavioral thresholds (r2 = 0.15; r2 = 0.28 for monopolar arrangements, and r2 = 0.12 for bipolar arrangements).

Ear & Hearing · Dec 1994

Simultaneous measurement of tinnitus pitch and loudness (opens in a new tab)

Penner MJ, Saran A

Abstract

Objective Simultaneous measures of the frequency and level of a pure tone matching the predominant pitch and loudness of tinnitus were obtained using four interleaved staircases. Design Two staircases in a forced-choice procedure tracked two frequencies, one higher and one lower than the predominant pitch of the tinnitus, while two staircases tracked two levels, one louder and one softer than the tinnitus. Results The standard deviation of the pitch matches to tinnitus using the forced-choice procedure with four staircases (4SFC) exceeded that from a double staircase (2SFC) task in which the level of the matching tone was fixed, whereas the 2SFC and 4SFC tasks had similar SDs for loudness matches to tinnitus when the frequency of the matching tone was fixed and for matches to the pitch or loudness of external tones. As the level of the tone matching the tinnitus pitch in the 4SFC task increased relative to that of the 2SFC task, so did its frequency. Conclusion These data may be interpreted as indicating that tinnitus is a fluctuant signal, and that matches of pure tones to tinnitus are not single-valued.

The Journal of the Acoustical Society of America · Oct 1994

Amplitude modulation rate discrimination with sinusoidal carriers (opens in a new tab)

Lee J

Abstract

Discrimination of the change in rate of sinusoidal amplitude modulation was investigated for sinusoidal carriers. The just-noticeable change in the modulation rate was measured as a function of (1) carrier frequency (fc = 500, 1000, 2000, or 4000 Hz), (2) initial modulation rate (fm = 10, 20, 40, 80, 160, or 320 Hz), and (3) stimulus duration (T = 62, 125, 250, 500, 1000, or 2000 ms). For modulation rates less than 320 Hz, the thresholds for a change in modulation rate were not affected by changing the carrier frequency. When fm = 320 Hz, the threshold for changes in the modulation rate ordered in the same way as the threshold for changes in the frequency of a pure tone, suggesting that the primary cue for discriminating a change in modulation rate was the frequency of either sideband. As stimulus duration increased to a certain T (critical duration), the thresholds decreased by more than a factor of 2. Above that duration, the thresholds for changes in modulation rate decreased only slightly or remained constant. The critical duration corresponded to about five cycles of modulation, at least for the slower modulation rates.

The Journal of the Acoustical Society of America · Oct 1994

Loudness growth in forward masking: Relation to intensity discrimination (opens in a new tab)

Zeng FG

Abstract

The growth of loudness of a tone burst following an intense forward masker was measured as a function of the tone level. The level of the forward-masked tone was adjusted to balance the loudness of a standard tone presented without a forward masker, using a 2AFC, double-staircase, tracking procedure. The forward masker was a 90-dB SPL, 100-ms, 1000-Hz pure tone. The standard tone and the masked tone were both 25-ms, 1000-Hz pure tones. The forward masker and the masked tone were always presented in the first interval. With a 100-ms delay between them, there was little or no threshold elevation for the masked tone. However, the masker caused the masked tone to sound louder than it would if it had not been masked, a phenomenon termed "loudness enhancement" [Irwin and Zwislocki, Percept. Psychophys. 10, 189-192 (1971); Galambos et al., J. Acoust. Soc. Am. 52, 1127-1130 (1972)]. In addition, the present results show a nonmonotonic enhancement function that the forward masker introduced a 10-16-dB enhancement effect for tones of 40-65 dB SPL and no significant effect for the 30 and 90 dB SPL tones. The loudness variability in forward masking was estimated from the upper and lower sequences tracking the 21% and the 79% louder response levels on the psychometric function, respectively. The variability demonstrated a similar nonmonotonic function. In forward masking loudness grows more steeply at low-medium sensation levels, and merges with normal growth at high levels.(ABSTRACT TRUNCATED AT 250 WORDS)

The Journal of the Acoustical Society of America · Sep 1994

The effects of signal frequency and absolute bandwidth on gap detection in noise (opens in a new tab)

Snell KB, Ison JR, Frisina DR

Abstract

Whether temporal resolution in noisebursts is primarily determined by the highest frequency component in the signal or its absolute bandwidth remains unclear. In this study, the absolute bandwidths and upper cutoff frequencies of signal noisebursts were varied across broad frequency ranges, several times greater than previously jointly studied. The purpose was to determine how each independently affects detection, taking into consideration that bandwidth effects at one signal frequency might be very different from bandwidth effects at another. Gap detection thresholds were obtained for five subjects with normal hearing in a 2 IFC paradigm. Signals were noisebursts whose bandwidths and upper cutoff frequencies varied among 1, 2, 4, 8, and 12 kHz. Their duration was 150 ms and they were presented at an overall level of 75 dB SPL above a 45 dB SPL white noise floor. The largest mean gap detection threshold, 6.98 ms, was obtained for a noiseburst with a bandwidth of 1 kHz and upper cutoff frequency of 12 kHz. The smallest mean gap detection threshold, 2.22 ms, was found with a bandwidth and upper cutoff frequency of 12 kHz. Significant interactions were found to exist between absolute bandwidth and upper cutoff frequency. Although gap detection thresholds generally decreased with increasing signal frequency and bandwidth, the pattern was complex. When the absolute bandwidth was at least one-half the upper cutoff frequency then upper cutoff frequency and not bandwidth determined gap sensitivity; but when the absolute bandwidth was less than one-half of the upper frequency, then both determined gap thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Hearing Research · Jun 1994

Perception of temporal acoustic patterns by the goldfish (Carassius auratus) (opens in a new tab)

Fay RR

Abstract

The perception of temporal acoustic patterns was studied in the goldfish using classical respiratory conditioning in combination with a stimulus generalization paradigm. Stimuli consisted of a bandpass filtered pulse repeated in various periodic and aperiodic temporal patterns. In each of 14 experiments, animals received 40 conditioning trials to a given stimulus pattern and were then tested for generalization to eight novel stimuli differing only in temporal pattern. In experiments 1-5, animals were conditioned to a periodic pulse train with a particular interpulse interval (IPI) and then tested to novel periodic pulse trains with various IPIs. Generalization gradients were substantially symmetric and monotonic with repetition rate, suggesting a perceptual continuum in goldfish that is similar to periodicity pitch or roughness in human listeners. Several additional experiments indicated that the perceptual qualities of simple and complex temporal patterns are not primarily determined by spectral structure or pulse rate, but rather are determined by the distribution of IPIs. A model for the central analysis of IPIs was successful in accounting for the results of experiments in which animals were conditioned to simple, periodic stimuli. However, the model failed when animals were conditioned to more complex stimuli having aperiodic temporal patterns. These experiments demonstrate the potential usefulness of the stimulus generalization paradigm for investigating aspects of complex sound source perception in non-human animals.

The Journal of the Acoustical Society of America · Jun 1994

The location‐dependent nature of perceptually salient features of the human head‐related transfer functions (opens in a new tab)

Carlille S, Pralong D

Abstract

The human head-related transfer function (HRTF) has been recorded binaurally from eight subjects using an "in-ear" recording system, for 343 stimulus locations around the head. There are a number of systematic changes in the HRTF as a function of horizontal location and elevation, on and off the median plane, that could be used as cues to sound location. To identify which components of the HRTF might provide perceptually salient cues to sound location, the HRTFs were transformed using an auditory filter model which accounts for the frequency dependence of auditory sensitivity and the frequency and level-dependent characteristics of the auditory filters. These transformations indicated a systematic variation in the frequency of the peak excitation as a function of the horizontal location of a broad band stimulus. Furthermore, there were differences in the frequency range over which elevation-dependent changes in the excitation patterns varied as a function of the vertical meridian. Interaural level differences were also estimated using the excitation patterns. The across frequency pattern of ILDs were roughly symmetrical about the interaural axis, although there were substantial differences between each ear in the magnitude of the ILDs generated for ipsilateral sounds locations.

The Journal of the Acoustical Society of America · Jun 1994

Measuring the human head‐related transfer functions: A novel method for the construction and calibration of a miniature ”in‐ear”recording system (opens in a new tab)

Pralong D, Carlile S

Abstract

A method for the construction of a small "in-ear" system for recording the human-free field-to-eardrum and headphone-to-eardrum transfer functions is described. Customized in-ear inserts were obtained by a simple ear printing and electroplating method, resulting in a thin (< 0.25 mm) outer shell that minimized obstruction of the entrance at the ear canal. The insert can be used to position a microphone probe tube deep within the auditory canal. The effects of this recording system on the sound field in the ear canal were calibrated using a model head equipped with a second internal microphone close to the eardrum. Transfer functions were recorded for 343 different stimulus locations in free space and for a headphone sound source. For the free-field stimuli the presence of the recording system resulted in a small attenuation with maximum effects around 3.5 and 12.5 kHz (-1.5 and -2.0 dB, respectively). Passing the data through an auditory filter model reduced the averaged attenuation to less than -1.4 dB. Phase was undistorted up to 2.5 kHz. These results suggests that the perturbations produced by the insert are unlikely to be perceptually relevant.