TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

Journal of the American Academy of Audiology · 1999

Lexical neighborhood test: Test-retest reliability and interlist equivalency (opens in a new tab)

Karen Iler Kirk, Laurie S. Eisenberg, Amy S. Martinez, Marcia Hay-McCutcheon

System IIDD1Auditory Research
Abstract

Abstract This study examined the reliability and interlist equivalency of two new recorded spoken word recognition measures, the Lexical Neighborhood Test (LNT) and the Multisyllabic Lexical Neighborhood Test (MLNT), and evaluated the effects of lexical difficulty on spoken word recognition by children with hearing loss. Participants were 16 children with prelingual, profound deafness who used a cochlear implant. Test-retest reliability was high and no significant interlist differences were observed for both measures. In addition, we found that lexically "easy" words (i.e., those that occur often and have few phonemically words with which they are similar) were recognized correctly more often than lexically "hard" words (i.e., those with opposite characteristics). The results demonstrate that the LNT and MLNT provide reliable information about the spoken word recognition abilities of children with profound hearing loss who use cochlear implants. In addition, these new measures also provide more detailed information about the way in which these children organize and access spoken words from long-term lexical memory. Abbreviations: CHILDES = Child Language Data Exchange System; LNT = Lexical Neighborhood Test; MLNT = Multisyllabic Lexical Neighborhood Test; NAM = Neighborhood Activation Model; OC = oral communication; PB-K = Phonetically Balanced Kindergarten Word Lists; PTA = average of the pure-tone threshold hearing levels at 500, 1000, and 2000 Hz; SPL = speech presentation level; TC = total communication

Hearing Research · 1999

Attenuation of aminoglycoside-induced cochlear damage with the metabolic antioxidant α-lipoic acid (opens in a new tab)

Brendan J Conlon, Jean-Marie Aran, Jean-Paul Erre, David W Smith

(empty)ABR/DPOAE
Abstract

Free radical generation is increasingly implicated in a variety of pathological processes, including drug toxicity. Recently, a number of studies have demonstrated the ability of gentamicin to facilitate the generation of radical species both in vivo and in vitro, which suggests that this process plays an important role in aminoglycoside-induced ototoxicity. Free radical scavengers are compounds capable of inactivating free radicals, thereby attenuating their tissue damaging capacity. In this study we have determined the ability of the powerful free radical scavenger alpha-lipoic acid (100 mg/kg/day) to attenuate the cochlear damage induced by a highly ototoxic regimen of the aminoglycoside amikacin (450 mg/kg/day, i.m.). Experiments were carried out on pigmented guinea pigs initially weighing 200-250 g. Changes in cochlear function were characterized as shifts in compound action potential (CAP) thresholds, estimated every 5 days, by use of chronic indwelling electrodes implanted at the round window, vertex, and contralateral mastoid. Results showed that animals receiving alpha-lipoic acid in combination with amikacin demonstrated a significantly less severe elevation in CAP thresholds compared with animals receiving amikacin alone (P < 0.001; t-test). These results provide further evidence of the recently reported intrinsic role of free radical generation in aminoglycoside ototoxicity, and highlight a potential clinical therapeutic use of alpha-lipoic acid in the management of patients undergoing aminoglycoside treatment.

Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 1999

Operational constraints on the utility of virtual audio cueing (opens in a new tab)

Mark A. Ericson, Robert S. Bolia, W. Todd Nelson, Richard L. McKinley

Abstract

The potential of virtual audio display technology to provide operators with veridical spatial cues may be substantially constrained by factors that are common in many operational settings – i.e., high noise level, limitations in the bandwidth of the audio source and/or display. The purpose of this study was to examine the effects of varying the bandwidth of a virtual sound source in the presence of broadband noise in a reverberant environment. Specifically, the signal-to-noise ratio (SNR) was varied from +50 dB to −10 dB, and the signal was low pass filtered at 1.6 kHz, 4 kHz, 8 kHz, and 15 kHz. Correlational analyses comparing actual and perceived sound source location revealed that both signal bandwidth and signal-to-noise ratio influenced auditory localization acuity, and that even under optimal bandwidth and noise conditions (15 kHz and +50 dB) localization in elevation was extremely poor. These findings have numerous implications for the design of spatial audio displays, especially those meant to be used in noisy environments.

Hearing Research · 1999

Auditory brainstem response forward-masking recovery functions in older humans with normal hearing (opens in a new tab)

Walton J, Orlando M, Burkard R

Abstract

We investigated the auditory brainstem response (ABR) recovery from forward masking using toneburst maskers and probes. Two subject groups matched for hearing thresholds were evaluated: normal-hearing young adults (21-40 years) and older subjects (63-77 years) with normal audiometric thresholds. Stimuli consisted of 1, 4 and 8 kHz tonebursts, with 2-4 cycle rise/fall time and no plateau. Forward maskers were tonebursts of the same frequency, with a 5 ms rise/fall time and a 20 ms plateau time. Probes were presented at 40 dB above threshold, and the forward masker was adjusted to a level that just eliminated the ABR to the 40 dB sensation level toneburst when the probe onset occurred at masker offset. Forward-masker intervals varied from 2 to 64 ms. ABR wave V latencies were similar for the young and old age groups regardless of toneburst frequency. Under forward-masking conditions, wave V latency was prolonged for the shorter intervals, and recovered to baseline latency by 64 ms. The forward-masker recovery functions were nearly identical for the two age groups for the 1 kHz toneburst. In contrast, there were clear differences in the recovery functions for the two age groups for the 4 and 8 kHz tonebursts. Specifically, the mean latency shift was greater for the aged group for forward-masker intervals of 16 ms or less. The two age groups showed identical latency shifts for longer forward-masker intervals. These data demonstrate prolonged recovery from forward masking in older human subjects. As these subjects had audiometric thresholds within normal limits, one plausible interpretation of this finding is that the prolonged recovery time is a manifestation of an aging effect on the central auditory nervous system rather than the periphery.

Brain Research · 1999

Sleep and wakefulness modulation of the neuronal firing in the auditory cortex of the guinea pig (opens in a new tab)

Peña JL, Pérez-Perera L, Bouvier M, Velluti RA

Abstract

Sleep-related changes-including modification in sensory processing-that influence brain and body functions, occur during both slow wave and paradoxical sleep. Our aim was to investigate how cortical auditory neurons behave during the sleep/waking cycle, and to study cell firing patterns in relation to the processing of auditory information without the interference of anesthetic drugs. We recorded single cells in the A region of the auditory cortex in restrained, chronically-implanted guinea pigs, and compared their evoked and spontaneous activity during sleep stages and quiet wakefulness. A new classification of the unit's responses to simple sound during wakefulness is presented. Moreover, a number of the neurons in the primary auditory cortex exhibited significant quantitative changes in their evoked or spontaneous firing rates. These changes could be correlated to sleep stages or wakefulness in 42.2% to 58.3% of the sampled neurons. A similar population did not show behavioral related changes in firing rates. Our results indicate that the responsiveness of the auditory system during sleep may be considered partially preserved. An important result was that spontaneous and evoked activity may vary in opposite directions, i.e. , the evoked activity could increase while the spontaneous activity decrease or vice versa. Then, a general question was proposed: is the increased spontaneous activity in the auditory cortex, particularly during PS, related to auditory hypnic 'images'? The studied cortical auditory neurons exhibit changes in their firing rates in correlation to stages of sleep and wakefulness. This is consistent with the hypothesis that a general shift in the neuronal networks involved in sensory processing occurs during sleep.

Audiology · 1999

A comparison of efferent suppression of compound action potentials by simultaneous and non-simultaneous contralateral noise paradigms (opens in a new tab)

Perry BP, McSwain SD, Conlon BJ, Smith DW

Abstract

The intent of this study was to compare the effectiveness of continuous versus gated contralateral noise in producing efferent suppression of CAPs in guinea pigs. The average contralateral suppression was 2.0 dB when using gated noise, with ipsilateral tone-pip rates of 2 s(-1), and 1.4 dB when using continuous noise at an ipsilateral tone-pip rate of 31 s(-1). When the ipsilateral tone-pip rate employed in the simultaneous paradigm with continuous noise was reduced to 2 s(-1), a rate equivalent to that employed in the non-simultaneous paradigm, the average attenuation was 2.1 dB, a magnitude comparable to the suppression achieved using gated noise. The present data suggest that, when equated for ipsilateral tone-pip pulse rate, simultaneous and non-simultaneous contralateral masking paradigms produce comparable levels of efferent suppression.

The Journal of the Acoustical Society of America · 1999

Effect of temporal position, proportional variance, and proportional duration on decision weights in temporal pattern discrimination (opens in a new tab)

Sadralodabai T, Sorkin RD

Abstract

Two experiments investigated how listeners allocate their attention to different segments of a temporal pattern. The experiments allowed a direct test of the predictions of the Proportion of Total Duration (PTD) rule and the Component Relative Entropy (CoRE) model. Listeners had to decide whether two sequences of nine tones had the same or different temporal patterns (tone duration = 25 ms, tone frequency = 1000 Hz). A sequence's temporal pattern was determined by the time intervals between each tone's offset and the next tone's onset. On same trials, the time intervals at corresponding temporal positions in the two sequences were identical. On different trials, the corresponding time intervals were randomly varied. Listener attention to different temporal positions within a sequence was assessed by calculating the decision weights at each position. The results supported the CoRE model and were inconsistent with the PTD rule. Manipulating the mean of the time intervals within the sequence had no consistent effect on the pattern of weights (or on overall performance), indicating that listener attention was not affected by either the proportion of total duration or the perceptual salience of a longer or shorter time interval. However, manipulating the variance of the time intervals had a significant effect: the highest weight was given to the highest variance segment. This weighting strategy leads to better performance because higher variance segments are more diagnostic of whether the sequences are the same or different.

The Journal of the Acoustical Society of America · 1999

Masking with interaurally delayed stimuli: the use of “internal” delays in binaural detection (opens in a new tab)

van der Heijden M, Trahiotis C

Abstract

Detectability of 500-Hz tones was measured in the presence of broadband masking noise using three types of binaural conditions. In the first, the masker was presented diotically and the tone was interaurally delayed. In the second, the masker was interaurally delayed and the 500-Hz tone was presented either in phase (S0) or out of phase (S pi). In the third, the masker consisted of the sum of two independent noises having interaural delays of equal magnitude and opposite sign. The signal was, once more, presented either in phase (S0) or out of phase (S pi). Comparisons among the data and quantitative analyses assuming the use of compensatory "internal delays" suggested that internal delays are operative and compensate accurately for external delays of up to approximately 750 microseconds. The analyses also indicated that larger internal delays (i.e., up to 2 to 3 ms) are probably also operative. However, performance using such large internal delays appears to be degraded in accord with the hypothesis that their application introduces "noise" in the internal representation of the stimuli.

Neuroscience · 1999

Detection of glutamate decarboxylase isoforms in rat inferior colliculus following acoustic exposure (opens in a new tab)

Abbott SD, Hughes LF, Bauer CA, … Caspary DM

Abstract

The inferior colliculus is a central auditory structure which serves as a site for the integration of ascending and descending auditory information. Changes in central auditory structures may occur with acoustic exposure, which cannot be explained by alterations in cochlear function alone. Rats were exposed to a 10-kHz tone at 100 dB SPL for 9 h. Auditory brainstem response measures showed an initial 25-30-dB threshold shift across all tested frequencies. By 30 days post-exposure, thresholds for clicks and most frequencies returned to near control levels; however, thresholds remained elevated at 10 and 20 kHz. Inner hair cell loss was confined to apical and basal ends of the cochlea, and did not exceed 20%. Inferior colliculus levels of the two isoforms of the GABA synthetic enzyme glutamate decarboxylase (65,000 and 67,000 mol. wt forms) were measured immediately post-exposure (0 h) and at two and 30 days post-exposure using quantitative immunocytochemical and western blotting techniques. Zero-hour measures revealed a significant increase in the level of glutamate decarboxylase (mol. wt 67,000) protein (118%), as well as in the optical density (35%) of immunolabeled cells. By 30 days post-exposure, inferior colliculus protein levels of both glutamate decarboxylase isoforms were significantly below unexposed controls (39% and 21% for the 65,000 and 67,000 mol. wt forms, respectively). These studies describe increased markers for GABA immediately following acoustic exposure, followed by a decline to below control levels from two to 30 days post-exposure. It remains to be determined whether noise trauma-induced changes in glutamate decarboxylase levels in the inferior colliculus reflect protective up-regulation in response to intense stimulation, followed by the establishment of new neurotransmitter equilibrium levels.

Hearing Research · Dec 1998

Processing of sinusoidally frequency modulated signals in the nuclei of the lateral lemniscus of the big brown bat, Eptesicus fuscus (opens in a new tab)

Huffman RF, Argeles PC, Covey E

Abstract

Neurons in the nuclei of the lateral lemniscus (NLL) of the big brown bat, Eptesicus fuscus, show several distinctive patterns of response to unmodulated tones. Previous work suggests that sustained responders are specialized to transmit information about sound level and duration while onset responders transmit precise timing information. The biosonar signals of E. fuscus consist of multiple, downward frequency modulated sweeps that change in slope and repetition rate as the bat approaches a target. An obvious hypothesis would be that NLL neurons with sustained responses should discharge during the time when the frequency of a signal is within their response area, but that onset responders should discharge each time the frequency enters the excitatory portion of their response area. In this study we examined the responses of NLL neurons to sinusoidally frequency modulated (SFM) signals presented monaurally to awake, restrained bats. Extracellular recordings were obtained from single neurons in the multipolar and columnar divisions of the ventral nucleus (VNLLm and VNLLc), the intermediate nucleus (INLL) and the dorsal nucleus of the lateral lemniscus (DNLL). All NLL neurons responded synchronously to SFM signals under some conditions. The temporal precision of synchronization was quantified using a coefficient of synchronization (CS), where a value of I equals perfect synchrony. Maximum CS values ranged from 0.70 to >0.99, were generally highest at low modulation rates ( <200 Hz), and showed lowpass characteristics for modulation rate. The maximal modulation rates that elicited synchronous discharge ranged from 50 to 500 Hz. The highest maximal rates were found in the VNLLm and VNLLc, the lowest in DNLL. The ability of NLL neurons to synchronize their discharge to the pattern of an SFM signal is intermediate between that of neurons in the cochlear nucleus and in the inferior colliculus. For the majority of neurons in VNLLm, INLL and DNLL, the precision of synchronization was approximately equal for the downward and upward components of the SFM signal; in contrast, 69% of VNLLc neurons responded selectively to the downward component of the SFM signal. All VNLLc neurons and a subset of those in VNLLm, INLL, and DNLL responded synchronously to SFM signals only if the frequency excursions included a border of the excitatory frequency bandwidth, suggesting that the synchronous discharge was due primarily to the repeated passage of the stimulus frequency into and out of the excitatory portion of the response area. In the case of VNLLc neurons, only the high frequency border was effective; Other neurons, especially those in DNLL, responded synchronously to SFM signals with frequency excursions that were confined entirely within the excitatory response area.

Journal of Speech, Language, and Hearing Research · Dec 1998

Transient-evoked otoacoustic emissions as a measure of noise-induced threshold shift (opens in a new tab)

Marshall L, Heller LM

Abstract

Otoacoustic emissions and behavioral hearing thresholds were measured before and after exposure to a 10-min, 105-dB SPL, half-octave band of noise centered at 1.414 kHz. Along a single recovery function, transient-evoked otoacoustic-emission (TEOAE) measurements made with 74-dB pSPL nonlinear click ensembles were alternated with a Bekesy threshold-tracking procedure. Each of the 14 participants with normal hearing underwent 2 hour-long temporary-threshold shift (TTS) sessions as well as 2 pretest sessions and a posttest session. The Bekesy test frequency was fixed at 2.0 kHz, whereas emissions were analyzed in half-octave bandwidths with center frequencies ranging from 0.707 to 5.656 kHz. Results showed that (a) the maximum temporary emission shifts (TES) were half to 1 octave above the exposure frequency; (b) the 4.7-dB average temporary emission shift magnitude at approximately 2 min postexposure was less than half of the 11.7-dB average TTS; (c) the average recovery times for emissions and hearing thresholds were similar (188 vs. 186 min); and (d) the average TTS magnitude along the recovery function was predictable from TES magnitude. It is concluded that both TEOAEs and Bekesy thresholds reveal the same aspects of postexposure inner-ear changes.

Physiological Entomology · Dec 1998

The effect of ultrasound on the attractiveness of acoustic mating signals (opens in a new tab)

Farris HE, Forrest TG, Hoy RR

Abstract

Previous laboratory studies (Nolen & Hoy, 1986b) have shown that the phonotactic responses of flying crickets are influenced by the relative intensities of attractive (mating signal) and repulsive (predator) stimuli. At the functional level, these results suggest that predator cues (ultrasound) can change the attractiveness of a calling song. Using extracellular recordings from cervical connectives it was shown that, like other field crickets, Gryllus rubens (south-eastern field cricket) is sensitive to ultrasound. This ultrasonic sensitivity has probably evolved in response to predation pressure from echolocating bats. Using acoustic playback under field conditions, it was tested whether the relative attractiveness of two male calling songs was influenced by the simultaneous broadcast of ultrasound, A simulated male calling song of G. rubens was broadcast at two different intensities (109 and 103 dB) from two sound traps that caught flying crickets attracted to the songs. Simulated bat ultrasound was broadcast simultaneously with the high-intensity calling song (109 dB) and the relative catch in each of the two traps was measured. The intensity of the ultrasound was varied on different nights. The relative attractiveness of the high-intensity sound trap decreased significantly as the intensity of the ultrasound broadcast with it was increased. For the lowest of the ultrasound broadcast levels, the relative attractiveness did not differ from that expected for two calling songs broadcast without ultrasound. Thus, increased levels of simulated predation risk decreased the attractiveness of the calling song associated with it. These are the first field experiments to show that predation risk in the form of simulated bat ultrasound influences the phonotactic behaviour of flying crickets.

The Journal of the Acoustical Society of America · Dec 1998

Effects of noise and spectral resolution on vowel and consonant recognition: Acoustic and electric hearing (opens in a new tab)

Fu QJ, Shannon RV, Wang X

Abstract

Current multichannel cochlear implant devices provide high levels of speech performance in quiet. However, performance deteriorates rapidly with increasing levels of background noise. The goal of this study was to investigate whether the noise susceptibility of cochlear implant users is primarily due to the loss of fine spectral information. Recognition of vowels and consonants was measured as a function of signal-to-noise ratio in four normal-hearing listeners in conditions simulating cochlear implants with both CIS and SPEAK-like strategies. Six conditions were evaluated: 3-, 4-, 8-, and 16-band processors (CIS-like), a 6/20 band processor (SPEAK-like), and unprocessed speech. Recognition scores for vowels and consonants decreased as the S/N level worsened in all conditions, as expected. Phoneme recognition threshold (PRT) was defined as the S/N at which the recognition score fell to 50% of its level in quiet. The unprocessed speech had the best PRT, which worsened as the number of bands decreased. Recognition of vowels and consonants was further measured in three Nucleus-22 cochlear implant users using either their normal SPEAK speech processor or a custom processor with a four-channel CIS strategy. The best cochlear implant user showed similar performance with the CIS strategy in quiet and in noise to that of normal-hearing listeners when listening to correspondingly spectrally degraded speech. These findings suggest that the noise susceptibility of cochlear implant users is at least partly due to the loss of spectral resolution. Efforts to improve the effective number of spectral information channels should improve implant performance in noise.

The Journal of the Acoustical Society of America · Dec 1998

Nonmonotonicity of informational masking (opens in a new tab)

Oh EL, Lutfi RA

Abstract

Neff and Green [Percept. Psychophys. 41, 409-415 (1987)] report that the masking of single tones by random-frequency multitone maskers varies nonmonotonically with number of masker components (peaking at 10-50 components). In this paper it is shown that such results are well predicted by a model (the component-relative-entropy model, CoRE) wherein thresholds increase linearly with the ensemble variance of masker spectra smoothed by peripheral auditory filters [R. A. Lutfi, J. Acoust. Soc. Am. 94, 748-758 (1993)]. Three experiments were conducted. In the first, the nonmonotonic relation was replicated for 9 of 11 listeners in conditions similar to those of Neff and Green. In the second, the frequencies of masker components were fixed and the levels of components were varied randomly across presentations to simulate Gaussian noise. In this case, the nonmonotonicity and the total amount of masking for these listeners were shown to be significantly reduced. In the third experiment, masked thresholds for the signal were found to vary monotonically with the frequency spacing of masker components for a fixed number of masker components. Large individual differences among listeners were obtained in some experimental conditions. Individual as well as mean thresholds were well predicted by the CoRE model with an appropriate selection of the values of the two free parameters of the model for each listener.