TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

The Journal of the Acoustical Society of America · Mar 2000

Relationships among age-related differences in gap detection and word recognition (opens in a new tab)

Snell KB, Frisina DR

Abstract

The relationships among age-related differences in gap detection and word recognition in subjects with normal hearing or mild sensorineural hearing loss were explored in two studies. In the first study, gap thresholds were obtained for 40 younger and 40 older subjects. The gaps were carried by 150-ms, modulated, low-pass noise bursts with cutoff frequencies of 1 or 6 kHz. The noise bursts were presented at an overall level of 80 dB SPL in three background conditions. Mean gap thresholds ranged between 2.6 and 7.8 ms for the younger age group and between 3.4 and 10.0 ms for the older group. Mean gap thresholds were significantly larger for the older group in all six conditions. Gap thresholds were not significantly correlated with audiometric thresholds in either age group but the 1-kHz gap thresholds increased with age in the younger group. In the second study, the relationships among gap thresholds, spondee-in-babble thresholds, and audiometric thresholds of 66 subjects were examined. Compared with the older subjects, the younger group recognized the spondees at significantly lower (more difficult) spondee-to-babble ratios. In the younger group, spondee-in-babble thresholds were significantly correlated with gap thresholds in conditions of high-frequency masking. In the older group, spondee-in-babble thresholds, gap thresholds, and audiometric thresholds were not significantly correlated, but the spondee-in-babble thresholds and two audiometric thresholds increased significantly with age. These results demonstrate that significant age-related changes in auditory processing occur throughout adulthood. Specifically, age-related changes in temporal acuity may begin decades earlier than age-related changes in word recognition.

The Laryngoscope · Mar 2000

Characterization of an experimentally induced inner ear immune response (opens in a new tab)

Ma C, Billings P, Harris JP, Keithley EM

Abstract

Objective To determine the effects of a sterile immune response on the structure and function of the cochlea. Methods An immune response was created in guinea pigs by systemically sensitizing the animals to keyhole limpet hemocyanin and subsequently challenging the inner ear with the protein. Animals were allowed to survive for 1 to 5 weeks, after which the cochlea was evaluated histologically. Hearing was measured by auditory brainstem response before the inner ear challenge, during the survival period, and prior to sacrifice. Results Inflammatory cells infiltrated the cochlea from the circulation. Surface preparations and plastic sections of the organ of Corti 1 and 2 weeks after the initiation of the inflammation demonstrated degeneration of the sensory and supporting cells in cochlear turns containing inflammatory cells. Good preservation of structures was seen in the more apical cochlear turns with little or no inflammatory cells. In cochleas from animals that survived 5 weeks, most of the infiltrated cells were cleared after undergoing apoptosis and the inflammatory matrix in the scala tympani began to calcify. Hearing loss was moderate to severe depending on the amount of inflammation. Conclusion Although in general the immune response serves to protect an organism from infection, these results demonstrate that bystander injury associated with local immune responses in the cochlea, an organ incapable of regeneration, causes permanent cochlear destruction and hearing loss.

Proceedings of the National Academy of Sciences · Feb 2000

Dynamic sensory sensitivity and children’s word decoding skills (opens in a new tab)

Joel B. Talcott, Caroline Witton, Maggie F. McLean, … John F. Stein

Abstract

The relationship between sensory sensitivity and reading performance was examined to test the hypothesis that the orthographic and phonological skills engaged in visual word recognition are constrained by the ability to detect dynamic visual and auditory events. A test battery using sensory psychophysics, psychometric tests, and measures of component literacy skills was administered to 32 unselected 10-year-old primary school children. The results suggest that children's sensitivity to both dynamic auditory and visual stimuli are related to their literacy skills. Importantly, after controlling for intelligence and overall reading ability, visual motion sensitivity explained independent variance in orthographic skill but not phonological ability, and auditory FM sensitivity covaried with phonological skill but not orthographic skill. These results support the hypothesis that sensitivity at detecting dynamic stimuli influences normal children's reading skills. Vision and audition separately may affect the ability to extract orthographic and phonological information during reading.

The Journal of the Acoustical Society of America · Feb 2000

Psychophysical correlates of contralateral efferent suppression. I. The role of the medial olivocochlear system in “central masking” in nonhuman primates (opens in a new tab)

Smith DW, Turner DA, Henson MM

Abstract

An extensive physiological literature, including experimental and clinical studies in humans, demonstrates that activation of the medial olivocochlear (MOC) efferent system, by either contralateral sound or electrical stimulation, can produce significant alterations in cochlear function and suggests a role for the MOC system in influencing the auditory behavior of binaural hearing. The present data are from psychophysical studies in nonhuman primates which seek to determine if the noted physiological changes in response to contralateral acoustic stimulation have a perceptual counterpart. Four juvenile Japanese macaques were trained to respond to the presence of 1-s sinusoids, presented to the test ear, in an operant reinforcement paradigm. Thresholds were compared for frequencies ranging from 1.0 to 4.0 kHz in quiet, with thresholds measured when continuous, two octave-band noise, centered on the test tone frequency, was presented in the contralateral ear. Contralateral noise was presented at levels of 10-60 dB above detection threshold for the test-tone frequency. While some variability was evident across subjects, both in the frequency distribution and magnitude (as a function of contralateral noise level), all subjects exhibited an increase, or suppression of thresholds in the presence of contralateral noise. On average, thresholds increased systematically with contralateral noise level, to a peak of 7 dB. In one subject, the threshold increase seen with contralateral noise was significantly reduced when the MOC was surgically sectioned on the floor of the IVth ventricle. The characteristics of the measured shifts in behavioral thresholds, in the presence of contralateral noise reported here, are qualitatively and quantitatively similar to both efferent physiological suppression effects and psychophysical central masking threshold shifts which have been reported previously. These data suggest that at least some aspects of "central masking" are efferent-mediated peripheral processes, and that the term "central masking" may be incorrect.

The Journal of Neuroscience · Feb 2000

Coding of sound-source location by ensembles of cortical neurons (opens in a new tab)

Shigeto Furukawa, Li Xu, John C. Middlebrooks

Abstract

We examined the coding of sound-source location by ensembles of neurons in the auditory cortex. Broadband noise bursts were presented from loudspeakers throughout 360° in the horizontal plane. Sound levels varied from 20 to 40 dB above neural thresholds. We recorded temporal spike patterns simultaneously at 16 recording sites in area A2 of α-chloralose-anesthetized cats. Spike patterns of individual units varied in spike counts and in spike timing as a function of sound-source location. Ensembles of up to 19 units recorded simultaneously demonstrated additional location sensitivity in the form of relative spike counts and relative spike timing among neurons. We used an artificial neural network (ANN) algorithm to recognize ensemble spike patterns and, thereby, to infer the locations of sound sources. The ANN could estimate stimulus locations based on ensemble responses to single-stimulus presentations. Median errors (MEs) averaged 49.2 ± 11.9° (mean ± SD; n = 34; chance level, 90°). The ANN maintained better-than-chance performance even when input spike patterns were expressed as relative spike counts across units (i.e., no information available from absolute spike counts of individual units; ME, 63.0 ± 11.8°) or when spike latencies were represented as time relative to the first spike for each trial (i.e., no external time reference available; ME, 54.3 ± 12.4°). The ANN performance improved monotonically as the sizes of ensemble patterns were increased by combining patterns across the entire unit sample. The performance by ensembles of 128 units approached the level of localization performance of behaving cats.

Journal of the Association for Research in Otolaryngology · 2000

Ethyl benzene-induced ototoxicity in rats: a dose-dependent mid-frequency hearing loss (opens in a new tab)

Cappaert NL, Klis SF, Baretta AB, et al.

Abstract

Rats were exposed to ethyl benzene at 0, 300, 400 and 550 ppm for 8 hours/day for 5 consecutive days. Three to six weeks after the exposure, auditory function was tested by measuring compound action potentials (CAP) in the frequency range of 1-24 kHz and 2f1-f2 distortion product otoacoustic emissions (DPOAEs) in the frequency range of 4-22.6 kHz. In addition, outer hair cell (OHC) loss was quantified by histological examination. The lowest concentration ethyl benzene had no effect on any of the above measures. At 400 ppm, auditory thresholds were increased by 15 and 16 dB at 12 and 16 kHz, respectively, and at 550 ppm by 24, 31, and 22 dB at 8, 12, and 16 kHz, respectively. DPOAE amplitude growth with stimulus level was affected only after 550 ppm at 5.6, 8, and 11.3 kHz. OHC loss was found in two of the five examined locations in the cochlea. At 400 ppm, 25% OHC loss was found at the 11- and 21-kHz region. The highest concentration evoked 40% and 75% OHC loss at the 11- and 21-kHz location, respectively. Thus, the mid-frequency region of rats is affected after exposure to relatively low concentrations of ethyl benzene (400-550 ppm). These results indicate that ethyl benzene is one of the most potent ototoxic organic solvents known today.

Kidney International · 2000

Protection from ototoxicity of intraperitoneal gentamicin in guinea pig (opens in a new tab)

Sinswat P, Wu WJ, Sha SH, et al.

SigGenABR/DPOAE
Abstract

Background Aminoglycoside antibiotics are common to treat peritonitis and exit-site infections in patients on peritoneal dialysis. Ototoxicity (loss of hearing or balance) is a well-documented adverse effect of aminoglycosides, and severe ototoxic reactions have been noted in patients receiving these drugs by intraperitoneal lavage. We have proposed a free-radical hypothesis for the mechanism of aminoglycoside ototoxicity and suggested a therapeutic prevention by the concomitant administration of antioxidants or iron chelators. Here we investigate whether 2, 3-dihydroxybenzoate can prevent the ototoxicity of intraperitoneal gentamicin. Methods Two strains of pigmented guinea pigs received daily intraperitoneal injections of gentamicin. Both strains developed ototoxicity, although different dosages were needed to produce similar auditory deficits (120 mg gentamicin base/kg body weight daily for 19 days vs. 135 mg/kg for 14 days). Dihydroxybenzoate was administered intraperitoneally once or twice daily. Auditory thresholds were measured by evoked brain stem response. Pathology was assessed as a loss of sensory cells in surface preparations of the organ of Corti. Results The auditory threshold shifts and hair cell loss were similar to the pathology observed following subcutaneous injections of gentamicin. Animals sustained almost complete loss of outer hair cells in the basal cochlea and a progressive hearing loss with threshold shifts of 60 dB at 18 kHz. The concomitant administration of dihydroxybenzoate significantly attenuated the threshold shift to less than 30 dB and reduced the loss of hair cells. The treatment with dihydroxybenzoate did not affect serum gentamicin levels. Conclusions Antioxidant therapy is a promising approach to prevent aminoglycoside-induced hearing loss following intraperitoneal application.

Perception & Psychophysics · 2000

Differences in American English, Spanish, and monkey perception of thesay-stay trading relation (opens in a new tab)

Sinnott JM, Saporita TA

Abstract

An interesting phenomenon in human speech perception is the trading relation, in which two different acoustic cues both signal the same phonetic percept. The present study compared American English, Spanish, and monkey listeners in their perception of the trading relation between gap duration and F1 transition onset frequency in a synthetic say-stay continuum. For all the subjects, increased gap duration caused perception to change from say to stay; however, subjects differed in the extent to which the F1 cue traded with gap duration. For American English listeners, a change from a low to a high F1 onset caused a phoneme boundary shift of 26 msec toward shorter gap durations, indicating a strong trading relation. For Spanish listeners, the shift was significantly smaller at 13.7 msec, indicating a weaker trading relation. For monkeys, there was no shift at all, indicating no trading relation. These results provide evidence that the say-stay trading relation is dependent on perceptual learning from linguistic exposure.

Perception & Psychophysics · 2000

Empirical evaluation of axioms fundamental to Stevens’s ratio-scaling approach: I. Loudness production (opens in a new tab)

Ellermeier W, Faulhammer G

Abstract

Stevens's direct scaling methods rest on the assumption that subjects are capable of reporting or producing ratios of sensation magnitudes. Only recently, however, did an axiomatization proposed by Narens (1996) specify necessary conditions for this assumption that may be put to an empirical test. In the present investigation, Narens's central axioms of commutativity and multiplicativity were evaluated by having subjects produce loudness ratios. It turned out that the adjustments were consistent with the commutativity condition; multiplicativity (the fact that consecutive doubling and tripling of loudness should be equivalent to making the starting intensity six times as loud), however, was violated in a significant number of cases. According to Narens's (1996) axiomatization, this outcome implies that although in principle a ratio scale of loudness exists, the numbers used by subjects to describe sensation ratios may not be taken at face value.

The Laryngoscope · 2000

Hearing Preservation With Labyrinthine Ablation in Otitis Media (opens in a new tab)

Antonelli PJ, Briggs RD, Gerhardt KJ

Abstract

OBJECTIVES: Iatrogenic fenestration of the inner ear in the presence of otitis media is commonly associated with permanent hearing loss. Hearing can generally be preserved when the vestibular labyrinth is ablated in a controlled manner in noninflamed ears. The purpose of this study was to examine the feasibility of hearing preservation with violation of the inner ear in the presence of middle ear inflammation. STUDY DESIGN: Prospective and controlled animal model. METHODS: Otitis media was induced bilaterally in pigmented guinea pigs with transtympanic injection of Streptococcus pneumoniae, nontypeable Haemophilus influenzae, or formalin-killed nontypeable H influenzae. Two to 4 days after injection, the horizontal canal of one ear was transected and sealed. Hearing was tested before and after labyrinthine ablation. RESULTS: Otitis media was induced in all ears. Bacterial cultures were positive in 19 of 20 S pneumoniae-injected ears, and in 10 of 16 nontypeable H influenzae-injected ears. One week after surgery, elevation of click thresholds (> 15 dB) was encountered in none of the fenestrated or unfenestrated S pneumoniae-infected ears, in two of six unfenestrated and three of six fenestrated nontypeable H influenzae-infected ears, and in one of five killed-nontypeable H influenzae-injected ears both with and without fenestration. CONCLUSIONS: These data suggest that ablation of a semicircular canal in the presence of middle ear inflammation or infection does not necessarily lead to profound sensorineural hearing loss. Hearing loss associated with iatrogenic violation of the semicircular canals may be more dependent on factors other than the presence of nonspecific middle ear inflammation.

Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 2000

Velocity judgments of moving sounds in virtual acoustic displays (opens in a new tab)

Mark A. Ericson

Abstract

A pure tone sound source, moving along a linear left-to-right trajectory, was simulated over headphones. Six attributes of the object motion were varied independently in a randomized block, factorial design experiment. The independent variables included: 1) sound source velocity, 2) distance from the observer, 3) interaural time delays, 4) Doppler frequency shifts, 5) overall intensity and 6) signal duration. Eight listeners estimated the magnitude of the velocity of the simulated moving sound source in miles per hour. Five of the six independent variables were found to make statistically significant (p<.05) contributions to estimates of velocity magnitude. Correct velocity estimates were found to be moderately correlated with the minimal distance between the trajectory path and the observer, Doppler frequency shifts, and intensity changes. The simulated velocity of the sound source and interaural time delay variables, although statistically significant, explained less than ten percent of the variance in the data. Implications of these research findings for virtual acoustic display design are discussed.

Journal of the Association for Research in Otolaryngology · 2000

Auditory cortical images of tones and noise bands (opens in a new tab)

Arenberg JG, Furukawa S, Middlebrooks JC

Abstract

We examined the representation of stimulus center frequencies by the distribution of cortical activity. Recordings were made from the primary auditory cortex (area A1) of ketamine-anesthetized guinea pigs. Cortical images of tones and noise bands were visualized as the simultaneously recorded spike activity of neurons at 16 sites along the tonotopic gradient of cortical frequency representation. The cortical image of a pure tone showed a restricted focus of activity along the tonotopic gradient. As the stimulus frequency was increased, the location of the activation focus shifted from rostral to caudal. When cochlear activation was broadened by increasing the stimulus level or bandwidth, the cortical image broadened. An artificial neural network algorithm was used to quantify the accuracy of center-frequency representation by small populations of cortical neurons. The artificial neural network identified stimulus center frequency based on single-trial spike counts at as few as ten sites. The performance of the artificial neural network under various conditions of stimulus level and bandwidth suggests that the accuracy of representation of center frequency is largely insensitive to changes in the width of cortical images.

Journal of the Association for Research in Otolaryngology · 2000

Development of primary axosomatic endings in the anteroventral cochlear nucleus of mice (opens in a new tab)

Limb CJ, Ryugo DK

Abstract

The endbulb of Held is a large synaptic ending that arises from the myelinated auditory nerve fibers. Endbulbs exhibit an elaborate pattern of terminal branching and produce extensive contact with the postsynaptic cell body. These structural features appear to underlie the tight coupling between presynaptic activity and postsynaptic spike discharges. As a first step toward understanding the relationship between environmental sounds and the development of these neural elements, we examined the age-related changes in the morphology of endbulbs of Held in CBA/J mice, a strain known to retain good hearing throughout life. Neurobiotin was injected into the modiolus of the cochlea in CBA/J mice ranging in age from postnatal day 1 to 7 months. Light microscopic analyses suggest that endbulbs of the CBA/J mice develop from small bouton endings at birth into large, highly branched structures in adults. This increase in structural complexity occurs mostly during the second through eighth postnatal weeks, and general stages of development can be defined. In addition, we compared endbulb structure between adult CBA/J mice and adult shaker-2 mice (Myo15sh2/sh2) and heterozygous littermates (Myo15+/sh2). The shaker-2 mouse carries a mutated myosin 15 gene that results in congenital deafness, presumably due to abnormally short stereocilia in hair cell receptors. Neurobiotin was injected into the modiolus of adult CBA/J, Myo15sh2/sh2, and Myo15+/sh2 mice. Endbulbs of deaf adult Myo15sh2/sh2 mice exhibited a striking reduction in terminal branching compared with those of CBA/J and Myo15+/sh2 mice. Notably, the abnormal endbulbs of Myo15sh2/sh2 mice do not resemble immature endbulbs of normal-hearing mice, suggesting that deafness does not simply arrest development.

International Journal of Occupational Safety and Ergonomics : JOSE · 2000

Preferred levels of auditory danger signals (opens in a new tab)

Zera J, Nagórski A

Abstract

An important issue at the design stage of the auditory danger signal for a safety system is the signal audibility under various conditions of background noise. The auditory danger signal should be clearly audible but it should not be too loud to avoid fright, startling effects, and nuisance complaints. Criteria for designing auditory danger signals are the subject of the ISO 7731 (International Organization for Standardization [ISO], 1986) international standard and the EN 457 European standard (European Committee for Standardization [CEN], 1992). It is required that the A-weighted sound pressure level of the auditory danger signal is higher in level than the background noise by 15 dB. In this paper, the results of an experiment are reported, in which listeners adjusted most preferred levels of 3 danger signals (tone, sweep, complex sound) in the presence of a noise background (pink noise and industrial noise). The measurements were done for 60-, 70-, 80-, and 90-dB A-weighted levels of noise. Results show that for 60-dB level of noise the most preferred level of the danger signal is 10 to 20 dB above the noise level. However, for 90-dB level of noise, listeners selected a level of the danger signal that was equal to the noise level. Results imply that the criterion in the existing standards is conservative as it requires the level of the danger signal to be higher than the level of noise regardless of the noise level.

The Journal of the Acoustical Society of America · 2000

Fidelity of three-dimensional-sound reproduction using a virtual auditory display (opens in a new tab)

Langendijk EH, Bronkhorst AW

Abstract

The fidelity of reproducing free-field sounds using a virtual auditory display was investigated in two experiments. In the first experiment, listeners directly compared stimuli from an actual loudspeaker in the free field with those from small headphones placed in front of the ears. Headphone stimuli were filtered using head-related transfer functions (HRTFs), recorded while listeners were wearing the headphones, in order to reproduce the pressure signatures of the free-field sounds at the eardrum. Discriminability was investigated for six sound-source positions using broadband noise as a stimulus. The results show that the acoustic percepts of real and virtual sounds were identical. In the second experiment, discrimination between virtual sounds generated with measured and interpolated HRTFs was investigated. Interpolation was performed using HRTFs measured for loudspeaker positions with different spatial resolutions. Broadband noise bursts with flat and scrambled spectra were used as stimuli. The results indicate that, for a spatial resolution of about 6 degrees, the interpolation does not introduce audible cues. For resolutions of 20 degrees or more, the interpolation introduces audible cues related to timbre and position. For intermediate resolutions (10 degrees - 15 degrees) the data suggest that only timbre cues were used.

AUDIOLOGY JAPAN · 2000

Auditory Responses Measured by Topographic Near-infrared Spectroscopy (opens in a new tab)

Izumi Furuya, Koichi Mori

Abstract

無侵襲の脳機能測定法である近赤外分光法を用いて, 閾値付近 (0dBSL) と閾値上 (30dBSL) の0.5, 1, 4kHzの帯域雑音と1kHz純音聴取時における聴覚付近の脳反応を測定した。 帯域雑音を注意聴取時には, 聴覚野付近のヘモグロビン量の有意な変化が0dBSLにおいても全ての被検者で観察された。 また1kHz帯域雑音を無視させた条件においても, 80%の被検者で有意な反応が観察された。 純音1kHz注意聴取においても, 30dBSL時に全ての被検者で同様の有意な反応が観察されたが, 0dBSL時には2/5の被検者でのみ有意な反応が観察された。 帯域雑音において閾値付近の反応が得られることは, 本法の他覚的聴力検査への応用の可能性を示唆する。

The Journal of the Acoustical Society of America · Dec 1999

Frequency acuity and binaural masking release in dyslexic listeners (opens in a new tab)

Hill NI, Bailey PJ, Griffiths YM, Snowling MJ

Abstract

Two experiments compared auditory sensitivity in a group of 12 adult dyslexics and matched control listeners. The first experiment measured frequency discrimination and frequency modulation detection thresholds at both 1 and 6 kHz. Although thresholds were larger for the dyslexic group, the differences were not statistically reliable. The second experiment measured the binaural masking level difference for a 200 Hz pure tone in noise. Thresholds did not differ significantly between the two groups. The data provide little support for the hypothesis that dyslexic listeners are impaired in their ability to process information in the temporal fine structure of auditory stimuli.

The Journal of the Acoustical Society of America · Dec 1999

Consonant recordings for speech testing (opens in a new tab)

Shannon RV, Jensvold A, Padilla M, … Wang X

Abstract

Initial and medial consonants were recorded in three vowel contexts for use in speech recognition experiments. Five male and five female talkers were recorded producing the twenty-five consonants /b,d,g,p,t,k,m,n,ŋ,l,r,f,v,θ,ð,s,z,∫,t∫,dȝ,ȝ,j,w,ʍ,h/ in medial (v/C/v) and initial (C/v) positions using vowels /a/ (“hod”), /i/ (“heed”), and /u/ (“who’d”). The sampling rate for these recordings was 44.1 kHz. Representative tokens of each consonant were amplitude normalized to the steady-state portion of the vowel. Listening tests were conducted with normal-hearing listeners on a subset of twenty consonants in all three vowel contexts and in initial and medial positions. The results showed that the consonants were clearly recognized with only a few minor confusions, primarily between /v/ and /ð/. The full set of recordings is available for research use.