The Journal of Physiology · Apr 2026
S. Fang, T. Fleiner, F. Peng, … J. W. Schnupp
Abstract
Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. Although CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioural study on early deafened, bilaterally CI‐implanted rats that pulse timing ITDs completely dominate ITD perception, whereas sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcomes in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. image Key points Current bilateral cochlear implants mostly provide time cues of arriving sound in the envelope of stimulation rather than in the timing of pulses. A behavioural study on cochlear implanted rats has shown that pulse timing dominates binaural hearing. Here we examined the neural sensitivity to independent changes in time cues presented on the envelope or pulse timing, respectively, in rats with bilateral cochlear implants and different hearing experiences. Auditory midbrain neurons were consistently more sensitive to changes in pulse timing rather than envelope, irrespective of stimulus pulse rate, modulation rate or an animal's hearing experience.
Scientific Reports · Dec 2024
Anders J. Asp, Suelen Lucio Boschen, Su-Youne Chang, … J. Luis Lujan
Abstract
Alcohol use disorder (AUD) is a chronic relapsing brain disorder characterized by an impaired ability to stop or control alcohol consumption despite adverse social, occupational, or health consequences. AUD affects nearly one-third of adults at some point during their lives, with an associated cost of approximately $249 billion annually in the U.S. alone. The effects of alcohol consumption are expected to increase significantly during the COVID-19 pandemic, with alcohol sales increasing by approximately 54%, potentially exacerbating health concerns and risk-taking behaviors. Unfortunately, existing pharmacological and behavioral therapies for AUD are associated with poor success rates, with approximately 40% of individuals relapsing within three years of treatment.Pre-clinical studies have shown that chronic alcohol consumption leads to significant changes in synaptic function within the dorsal medial striatum (DMS), one of the brain regions associated with AUD and responsible for mediating goal-directed behavior. Specifically, chronic alcohol consumption has been associated with hyperactivity of dopamine receptor 1 (D1) medium spiny neurons (MSN) and hypoactivity of dopamine receptor 2 (D1) MSNs within the DMS. Optogenetic, chemogenetic, and transgenic approaches have demonstrated that reducing the D1/D2 MSN signaling imbalance decreases alcohol self-administration in rodent models of AUD.Here, we present an electrical stimulation approach that uses ultra-low (≤ 1 Hz) frequency (ULF) spike-timing-dependent plasticity (STDP) in mouse models of AUD to reduce DMS D1/D2 MSN signaling imbalances by stimulating D1-MSN afferents into the GPi and ACC glutamatergic projections to the DMS in a time-locked stimulation sequence. Our data suggest that GPi/ACC ULF-STDP selectively decreases DMS D1-MSN hyperactivity leading to reduced alcohol consumption without evoking undesired affective behaviors using electrical stimulation rather than approaches requiring genetic modification. This work represents a step towards fulfilling the unmet need for a reliable method of treating severe AUD through cell-type-specific control with clinically available neuromodulation tools.
eLife · Jan 2021
Nicole Rosskothen-Kuhl, Alexa N Buck, Kongyan Li, Jan WH Schnupp
Abstract
Spatial hearing in cochlear implant (CI) patients remains a major challenge, with many early deaf users reported to have no measurable sensitivity to interaural time differences (ITDs). Deprivation of binaural experience during an early critical period is often hypothesized to be the cause of this shortcoming. However, we show that neonatally deafened (ND) rats provided with precisely synchronized CI stimulation in adulthood can be trained to lateralize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, comparable ND rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. Our result that ND-CI rats achieved very good behavioral ITD thresholds, while prelingually deaf human CI patients often fail to develop a useful sensitivity to ITD raises urgent questions concerning the possibility that shortcomings in technology or treatment, rather than missing input during early development, may be behind the usually poor binaural outcomes for current CI patients.
Journal of Neural Engineering · Jul 2020
Evan N Nicolai, Megan L Settell, Bruce E Knudsen, … Kip A Ludwig
Abstract
Objective Clinical data suggest that efficacious vagus nerve stimulation (VNS) is limited by side effects such as cough and dyspnea that have stimulation thresholds lower than those for therapeutic outcomes. VNS side effects are putatively caused by activation of nearby muscles within the neck, via direct muscle activation or activation of nerve fibers innervating those muscles. Our goal was to determine the thresholds at which various VNS-evoked effects occur in the domestic pig—an animal model with vagus anatomy similar to human—using the bipolar helical lead deployed clinically. Approach Intrafascicular electrodes were placed within the vagus nerve to record electroneurographic (ENG) responses, and needle electrodes were placed in the vagal-innervated neck muscles to record electromyographic (EMG) responses. Main results Contraction of the cricoarytenoid muscle occurred at low amplitudes (∼0.3 mA) and resulted from activation of motor nerve fibers in the cervical vagus trunk within the electrode cuff which bifurcate into the recurrent laryngeal branch of the vagus. At higher amplitudes (∼1.4 mA), contraction of the cricoarytenoid and cricothyroid muscles was generated by current leakage outside the cuff to activate motor nerve fibers running within the nearby superior laryngeal branch of the vagus. Activation of these muscles generated artifacts in the ENG recordings that may be mistaken for compound action potentials representing slowly conducting Aδ-, B-, and C-fibers. Significance Our data resolve conflicting reports of the stimulation amplitudes required for C-fiber activation in large animal studies (>10 mA) and human studies (<250 μ A). After removing muscle-generated artifacts, ENG signals with post-stimulus latencies consistent with Aδ- and B-fibers occurred in only a small subset of animals, and these signals had similar thresholds to those that caused bradycardia. By identifying specific neuroanatomical pathways that cause off-target effects and characterizing the stimulation dose-response curves for on- and off-target effects, we hope to guide interpretation and optimization of clinical VNS.
Frontiers in Neuroscience · Jul 2020
Mina Sadeghi Najafabadi, Longtu Chen, Kelsey Dutta, … Monty A. Escabí
Abstract
Neural implants that deliver multi-site electrical stimulation to the nervous systems are no longer the last resort but routine treatment options for various neurological disorders. Multi-site electrical stimulation is also widely used to study nervous system function and neural circuit transformations. These technologies increasingly demand dynamic electrical stimulation and closed-loop feedback control for real-time assessment of neural function, which is technically challenging since stimulus-evoked artifacts overwhelm the small neural signals of interest. We report a novel and versatile artifact removal method that can be applied in a variety of settings, from single- to multi-site stimulation and recording and for current waveforms of arbitrary shape and size. The method capitalizes on linear electrical coupling between stimulating currents and recording artifacts, which allows us to estimate a multi-channel linear Wiener filter to predict and subsequently remove artifacts via subtraction. We confirm and verify the linearity assumption and demonstrate feasibility in a variety of recording modalities, including in vitro sciatic nerve stimulation, bilateral cochlear implant stimulation, and multi-channel stimulation and recording between the auditory midbrain and cortex. We demonstrate a vast enhancement in the recording quality with a typical artifact reduction of 25-40 dB. The method is efficient and can be scaled to arbitrary number of stimulus and recording sites, making it ideal for applications in large-scale arrays, closed-loop implants, and high-resolution multi-channel brain-machine interfaces.