Hearing Research · Apr 2026
Akkol S, Herrero JL, Espinal E, … Bickel S
Abstract
Electrical brain stimulation (EBS) has been studied as a tool to improve speech perception. Available EBS methods compromise between precision and power and rarely consider temporal dynamics. Noninvasive EBS delivers currents to wide areas but may lack regional specificity and is susceptible to current shunting through the skin. We introduce a novel minimally-invasive electrical brain stimulation approach using clinically implanted epicranial electrodes and cranial bolts, circumventing the current shunting limitations of traditional transcranial stimulation. Two types of contacts were used in five epilepsy patients (one female) over six experimental sessions undergoing intracranial monitoring: epicranial electrodes (served as reference electrodes for clinical recordings) and cranial bolts (holding fixtures for depth electrodes). Participants monaurally listened to pseudo-randomly presented sentences from matrix sentence speech-in-noise task in 3 conditions: no-stimulation, 50 ms, or 200 ms stimulation lag relative to sentence onset. EBS parameters were 100 Hz, biphasic, amplitude-balanced, square-wave pulses where the amplitude (1-6 mA) was modulated by the ongoing speech envelope. Accuracy in the task improved in 5 of 6 sessions while not reaching significance across sessions possibly limited due to the limited number of sessions and trials (p = 0.087 and 0.068 for 50 ms and 200 ms delay, linear mixed-effects model). In 5/6 sessions, there was increased accuracy with 50 ms delay, and in 3 of those, there was further improvement with 200 ms delay. We successfully demonstrated the dynamic EBS patterns delivered through minimally-invasive electrodes during speech perception with 83% responder rate for improvement in speech perception with short latency (50 ms) and 50% with longer latency (200 ms) stimulation.
May 2023
Stephan L Blanz
Abstract
This protocol was used to collect data now published in the Journal of Neural Engineering, Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect using the multi-contact ImThera stimulating device. https://doi.org/10.1088/1741-2552/acb3fd Dataset has been published to pennsieve.io and can be found at: https://doi.org/10.26275/efbj-8evl
Scientific Reports · Feb 2023
Joshua Rosing, Alex Doyle, AnneMarie Brinda, … Matthew D. Johnson
Abstract
Electrically evoked compound action potentials (ECAPs) generated in the subthalamic nucleus (STN) contain features that may be useful for titrating deep brain stimulation (DBS) therapy for Parkinson’s disease. Delivering a strong therapeutic effect with DBS therapies, however, relies on selectively targeting neural pathways to avoid inducing side effects. In this study, we investigated the spatiotemporal features of ECAPs in and around the STN across parameter sweeps of stimulation current amplitude, pulse width, and electrode configuration, and used a linear classifier of ECAP responses to predict electrode location. Four non-human primates were implanted unilaterally with either a directional (n = 3) or non-directional (n = 1) DBS lead targeting the sensorimotor STN. ECAP responses were characterized by primary features (within 1.6 ms after a stimulus pulse) and secondary features (between 1.6 and 7.4 ms after a stimulus pulse). Using these features, a linear classifier was able to accurately differentiate electrodes within the STN versus dorsal to the STN in all four subjects. ECAP responses varied systematically with recording and stimulating electrode locations, which provides a subject-specific neuroanatomical basis for selecting electrode configurations in the treatment of Parkinson’s disease with DBS therapy.
Journal of Neural Engineering · Feb 2023
Stephan L Blanz, Eric D Musselman, Megan L Settell, … Kip A Ludwig
Abstract
Electrical stimulation of the cervical vagus nerve using implanted electrodes (VNS) is FDA-approved for the treatment of drug-resistant epilepsy, treatment-resistant depression, and most recently, chronic ischemic stroke rehabilitation. However, VNS is critically limited by the unwanted stimulation of nearby neck muscles—a result of non-specific stimulation activating motor nerve fibers within the vagus. Prior studies suggested that precise placement of small epineural electrodes can modify VNS therapeutic effects, such as cardiac responses. However, it remains unclear if placement can alter the balance between intended effect and limiting side effect. We used an FDA investigational device exemption approved six-contact epineural cuff to deliver VNS in pigs and quantified how epineural electrode location impacts on- and off-target VNS activation. Detailed post-mortem histology was conducted to understand how the underlying neuroanatomy impacts observed functional responses. Here we report the discovery and characterization of clear neuroanatomy-dependent differences in threshold and saturation for responses related to both effect (change in heart rate) and side effect (neck muscle contractions). The histological and electrophysiological data were used to develop and validate subject-specific computation models of VNS, creating a well-grounded quantitative framework to optimize electrode location-specific activation of nerve fibers governing intended effect versus unwanted side effect.
Jan 2023
Stephan L Blanz
Abstract
This protocol was used to collect data now published in the Journal of Neural Engineering, Spatially selective stimulation of the pig vagus nerve to modulate target effect versus side effect using the multi-contact ImThera stimulating device. https://doi.org/10.1088/1741-2552/acb3fd Dataset has been published to pennsieve.io and can be found at: https://doi.org/10.26275/efbj-8evl
Journal of Neural Engineering · May 2022
Borda E, Gaillet V, Airaghi Leccardi MJI, … Ghezzi D
Abstract
Objective. Intraneural nerve interfaces often operate in a monopolar configuration with a common and distant ground electrode. This configuration leads to a wide spreading of the electric field. Therefore, this approach is suboptimal for intraneural nerve interfaces when selective stimulation is required. Approach. We designed a multilayer electrode array embedding three-dimensional concentric bipolar (CB) electrodes. First, we validated the higher stimulation selectivity of this new electrode array compared to classical monopolar stimulation using simulations. Next, we compared them in-vivo by intraneural stimulation of the rabbit optic nerve and recording evoked potentials in the primary visual cortex. Main results. Simulations showed that three-dimensional CB electrodes provide a high localisation of the electric field in the tissue so that electrodes are electrically independent even for high electrode density. Experiments in-vivo highlighted that this configuration restricts spatial activation in the visual cortex due to the fewer fibres activated by the electric stimulus in the nerve. Significance. Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation. The multilayer array embedding three-dimensional CB electrodes improves selectivity in optic nerve stimulation. This approach is suitable for other neural applications, including bioelectronic medicine.
bioRxiv* · Mar 2022
Eleonora Borda, Vivien Gaillet, Marta JI Airaghi Leccardi, … Diego Ghezzi
Abstract
Objective: Intraneural nerve interfaces often operate in a monopolar configuration with a common and distant ground electrode. This configuration leads to a wide spreading of the electric field. Therefore, this approach is suboptimal for intraneural nerve interfaces when selective stimulation is required. Approach: We designed a multilayer electrode array embedding three-dimensional concentric bipolar electrodes. First, we validated the higher stimulation selectivity of this new electrode array compared to classical monopolar stimulation using simulations. Next, we compared them in-vivo by intraneural stimulation of the rabbit optic nerve and recording evoked potentials in the primary visual cortex. Main results: Simulations showed that three-dimensional concentric bipolar electrodes provide a high localisation of the electric field in the tissue so that electrodes are electrically independent even for high electrode density. Experiments in-vivo highlighted that this configuration leads to evoked responses with lower amplitude and more localised cortical patterns due to the fewer fibres activated by the electric stimulus in the nerve. Significance: Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation. The multilayer array embedding three-dimensional concentric bipolar electrodes improves selectivity in optic nerve stimulation. This approach is suitable for other neural applications, including bioelectronic medicine.
Journal of Neurophysiology · Nov 2021
Herrero JL, Smith A, Mishra A, et al.
Abstract
θ-Burst stimulation (TBS) protocols in transcranial magnetic stimulation studies have shown improved treatment efficacy in a variety of neuropsychiatric disorders. The optimal protocol to induce neuroplasticity in invasive direct electrical stimulation approaches is not known. We report that intracranial TBS applied in human sensorimotor cortex increases local coherence of preexistent β rhythms. The effect is specific to the stimulation frequency and the stimulated network and outlasts the stimulation period by ∼3 min.
Journal of Neural Engineering · Aug 2021
Gaillet V, Borda E, Zollinger EG, et al.
Abstract
Abstract Objective . Optic nerve’s intraneural stimulation is an emerging neuroprosthetic approach to provide artificial vision to totally blind patients. An open question is the possibility to evoke individual non-overlapping phosphenes via selective intraneural optic nerve stimulation. To begin answering this question, first, we aim at showing in preclinical experiments with animals that each intraneural electrode could evoke a distinguishable activity pattern in the primary visual cortex. Approach . We performed both patterned visual stimulation and patterned electrical stimulation in healthy rabbits while recording evoked cortical activity with an electrocorticogram array in the primary visual cortex. Electrical stimulation was delivered to the optic nerve with the intraneural array OpticSELINE. We used a support vector machine algorithm paired to a linear regression model to classify cortical responses originating from visual stimuli located in different portions of the visual field and electrical stimuli from the different electrodes of the OpticSELINE. Main results . Cortical activity induced by visual and electrical stimulation could be classified with nearly 100% accuracy relative to the specific location in the visual field or electrode in the array from which it originated. For visual stimulation, the accuracy increased with the separation of the stimuli and reached 100% for separation higher than 7°. For electrical stimulation, at low current amplitudes, the accuracy increased with the distance between electrodes, while at higher current amplitudes, the accuracy was nearly 100% already for the shortest separation. Significance . Optic nerve’s intraneural stimulation with the OpticSELINE induced discernible cortical activity patterns. These results represent a necessary condition for an optic nerve prosthesis to deliver vision with non-overlapping phosphene. However, clinical investigations will be required to assess the translation of these results into perceptual phenomena.
bioRxiv* · Mar 2021
Jose L. Herrero, Alexander Smith, Akash Mishra, … Stephan Bickel
Abstract
The progress of therapeutic neuromodulation greatly depends on improving stimulation parameters to most efficiently induce neuroplasticity effects. Intermittent Theta Burst stimulation (iTBS), a form of electrical stimulation that mimics the natural brain activity patterns, has shown efficacy in inducing such effects in animal studies and rhythmic Transcranial Magnetic Stimulation (rTMS) studies in humans. However, little is known about the potential neuroplasticity effects of iTBS applied through intracranial electrodes in humans which could have implications for deep brain stimulation therapies. This study characterizes the physiological effects of cortical iTBS in the human cortex and compare them with single pulse alpha stimulation, another frequently used paradigm in rTMS research. We applied these stimulation paradigms to well-defined regions in the sensorimotor cortex which elicited contralateral hand or arm muscle contractions during electrical stimulation mapping in epilepsy patients implanted with intracranial electrodes. Treatment effects were evaluated using effective connectivity and beta oscillations coherence measures in areas connected to the treatment site as defined with cortico-cortical evoked potentials. Our results show that iTBS increases beta band synchronization within the sensorimotor network indicating a potential neuroplasticity effect. The effect is specific to the sensorimotor system, the beta frequency band and the stimulation pattern (no effect was found with single-pulse alpha stimulation). The effects outlasted the stimulation by three minutes. By characterizing the neurophysiological effects of iTBS within well-defined cortical networks, we hope to provide an electrophysiological framework that allows clinicians and researchers to optimize brain stimulation protocols which may have translational value.
Aug 2020
Evan N Nicolai, Kip Ludwig
Abstract
This protocol was used to collect data now published in the Journal of Neural Engineering, Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs, see Metadata for citation. Additionally, the dataset is publicly available on Pennsieve 10.26275/qcuk-a8ty.
Journal of Neural Engineering · Jul 2020
Evan N Nicolai, Megan L Settell, Bruce E Knudsen, … Kip A Ludwig
Abstract
Objective Clinical data suggest that efficacious vagus nerve stimulation (VNS) is limited by side effects such as cough and dyspnea that have stimulation thresholds lower than those for therapeutic outcomes. VNS side effects are putatively caused by activation of nearby muscles within the neck, via direct muscle activation or activation of nerve fibers innervating those muscles. Our goal was to determine the thresholds at which various VNS-evoked effects occur in the domestic pig—an animal model with vagus anatomy similar to human—using the bipolar helical lead deployed clinically. Approach Intrafascicular electrodes were placed within the vagus nerve to record electroneurographic (ENG) responses, and needle electrodes were placed in the vagal-innervated neck muscles to record electromyographic (EMG) responses. Main results Contraction of the cricoarytenoid muscle occurred at low amplitudes (∼0.3 mA) and resulted from activation of motor nerve fibers in the cervical vagus trunk within the electrode cuff which bifurcate into the recurrent laryngeal branch of the vagus. At higher amplitudes (∼1.4 mA), contraction of the cricoarytenoid and cricothyroid muscles was generated by current leakage outside the cuff to activate motor nerve fibers running within the nearby superior laryngeal branch of the vagus. Activation of these muscles generated artifacts in the ENG recordings that may be mistaken for compound action potentials representing slowly conducting Aδ-, B-, and C-fibers. Significance Our data resolve conflicting reports of the stimulation amplitudes required for C-fiber activation in large animal studies (>10 mA) and human studies (<250 μ A). After removing muscle-generated artifacts, ENG signals with post-stimulus latencies consistent with Aδ- and B-fibers occurred in only a small subset of animals, and these signals had similar thresholds to those that caused bradycardia. By identifying specific neuroanatomical pathways that cause off-target effects and characterizing the stimulation dose-response curves for on- and off-target effects, we hope to guide interpretation and optimization of clinical VNS.
Nature Biomedical Engineering · Aug 2019
Gaillet V, Cutrone A, Artoni F, … Ghezzi D
Abstract
Retinal prostheses can restore a functional form of vision in patients affected by dystrophies of the outer retinal layer. Beyond clinical utility, prostheses for the stimulation of the optic nerve, the visual thalamus or the visual cortex could also serve as tools for studying the visual system. Optic-nerve stimulation is particularly promising because it directly activates nerve fibres, takes advantage of the high-level information processing occurring downstream in the visual pathway, does not require optical transparency and could be effective in cases of eye trauma. Here we show, in anaesthetized rabbits and with support from numerical modelling, that an intraneural electrode array with high mechanical stability placed in the intracranial segment of the optic nerve induces, on electrical stimulation, selective activation patterns in the visual cortex. These patterns are measured as electrically evoked cortical potentials via an ECoG array placed in the contralateral cortex. The intraneural electrode array should enable further investigations of the effects of electrical stimulation in the visual system and could be further developed as a visual prosthesis for blind patients.
* Preprint: not yet peer reviewed.