bioRxiv · Jul 2026
Michael Brosch, Hiroyuki Oya, Katherine N. Gibson-Corley, … Kirill V. Nourski
Abstract
Background Direct current (DC) stimulation can modulate neuronal activity in ways that differ from pulsatile stimulation, but its intracranial use has been limited by concerns about tissue injury at the electrode/tissue interface. Quantitative safety limits for DC delivered through metal electrodes directly to the brain remain poorly defined. Objective To estimate histological safety boundaries for DC stimulation delivered through metal electrodes in a large-brain gyrencephalic animal model. Methods Cathodal DC stimulation was applied to the exposed cortical surface of ten anesthetized sheep using platinum–iridium disc electrodes typically used in clinical applications (surface area ≤ 4.15 mm 2 ). Currents of 5 to 1000 µA were delivered for 10 to 15 minutes at 36 cortical sites. Stimulation dose was quantified as charge density. Brains were removed shortly after stimulation and examined histologically for tissue damage, including necrosis, inflammation, gliosis, and demyelination. Lesion volumes were quantified and related to charge density. Results No lesions were observed at sites where no current or a low charge density (0.7 mC/mm 2 ) was delivered. With stimulation, lesion probability and volume increased with charge density, although variability was substantial. Lesions occurred in 3 of 18 sites at lower charge densities (1.4 to 10 mC/mm 2 ) and in 5 of 9 sites at higher charge densities (14.4 to 144.4 mC/mm 2 ). Linear regression of lesion volume against charge density yielded an estimated zero-lesion intercept of 2.3 mC/mm 2 , whereas alternative nonlinear models predicted thresholds up to 8.7 mC/mm 2 . Conclusion These findings suggest that it may be possible to apply cathodal DC stimulation directly to the cortical surface through metal electrodes without detectable histological damage when current intensity, duration, and electrode size are appropriately constrained. These findings provide quantitative guidance for the safe application of DC directly to neural tissue in experimental and translational neuromodulation studies.
Brain Stimulation · 2026
Kyungsoo Kim, Giri P. Krishnan, JaeYeon Kim, … Karunesh Ganguly
Abstract
Background: Electrical stimulation targeting the motor thalamus (Mthal) represents an emerging strategy for regulating motor cortical activity patterns, however the fundamental mechanisms and optimal stimulation configurations are not well established. Objective: To characterize how burst Mthal stimulation modulates cortical activity and to identify stimulation parameters that maximize cortical co-firing via thalamocortical rebound mechanisms. Methods: We conducted acute electrophysiological experiments in anesthetized rats using Mthal stimulation with systematically manipulated burst stimulation parameters (i.e., number of pulses and pulse width) in the low-frequency band (1-8 Hz) modulation cycle. Cortical responses across large areas covering primary and secondary motor cortex were recorded. Additionally, intracortical recordings were performed for detailed spike activity monitoring during stimulation. Cortical activity patterns in local field potentials and spike activity were analyzed to quantify the effects of Mthal stimulation on motor cortex. Computational thalamocortical circuit models were employed to explore the mechanistic basis of frequency-selective modulation effects. Results: Burst Mthal stimulation elicited tunable cortical excitation, with optimal modulation achieved at 3-4 Hz. This preferred frequency corresponded to the natural rebound timing of thalamocortical (TC) cells and generated maximal cortical co-firing and synchronization. Higher stimulation frequencies (e.g., 8 Hz) resulted in suppressed and diminished responses. Computational modeling further validated that the cellular mechanism of the TC cell rebound excitation leads to frequency-dependent cortical modulation. Conclusion: Burst Mthal stimulation demonstrates frequency-selective modulation of cortical network excitability, with 3-4 Hz protocols providing optimal enhancement of synchronized activity through exploitation of thalamocortical rebound dynamics. These results establish motor thalamic stimulation as a promising and efficient methodology for precise cortical network control and offer mechanistic foundations for developing therapeutic neuromodulation interventions aimed at motor system rehabilitation.
bioRxiv · Sep 2025
Andrés Pascual-Leone, Vishweshwar Tyagi, Ahmet S. Asan, … Jason B. Carmel
Abstract
Target engagement determines therapeutic efficacy. In spinal cord stimulation (SCS), efficacy depends on the attributes of the electrodes used to deliver stimulation, particularly their position, interelectrode distance, size, and current orientation. We tested the effects of these electrode parameters using cervical stimulation to elicit forelimb muscle responses in the rat. We implanted devices over the C6 dorsal root entry zone (DREZ) in eight rats and measured responses in six forelimb muscles. We used custom designed electrode arrays to systematically vary position, distance, and size with linear arrays, and current orientation with circular arrays. Stimulation consisted of biphasic and pseudomonophasic pulse shapes with bipolar or distant return, and a high-definition montage with four returns surrounding a central contact to increase local current density. Efficacy was calculated from the motor thresholds of recruitment curves, and parameters were compared using linear mixed models. For position, stimulation over the DREZ was most effective, reducing thresholds by 25.9% ( p = 0.0002) relative to the midline; efficacy decreased as the electrode was positioned medial or lateral to the DREZ. For distance, placing the electrodes farther apart significantly improved efficacy ( p = 0.0022). For size, large electrodes increased SCS efficacy, reducing thresholds by 21.5% ( p = 0.0026) relative to small electrodes. After accounting for position and distance, current orientation did not affect SCS efficacy. Lastly, the high-definition montage decreased efficacy, increasing thresholds by 16.7% ( p = 0.003) relative to monopolar stimulation with a distant return. In conclusion, electrode position, distance, and size had the greatest effect on SCS efficacy, with the optimal parameters combining large electrodes at the DREZ position with a distant return. These results have the potential to lower the current needed to engage cervical spinal circuitry and to inform the design of SCS systems to improve dexterity in people with neurological injury or disease.
Nature Communications · Aug 2025
Shriya Srinivasan, Marc-Joseph Antonini, Amro Alshareef, … Giovanni Traverso
Abstract
Gastrointestinal (GI) dysmotility and associated conditions affect over 20% of population, yet pharmacological, behavioural, and surgical interventions offer limited therapeutic efficacy. Targeted electrical stimulation addressing underlying neuromuscular pathology stands to transform our ability to treat dysmotility. Here, we developed a closed-loop GI neuroprosthesis which activates or relaxes GI tract musculature through electrochemical stimulation in response to sensed food stimuli. We additionally describe a tool supporting minimally invasive endoscopically guided implantation that can penetrate the mucosa, accurately localize the submucosa, and safely deploy this device to directly interface with the enteric nervous system. The neuroprosthesis enables generation of coordinated peristaltic waves, significantly increasing the motility rate in a swine model of oesophageal and stomach dysmotility (p < 0.05, student's t-test). Further, by directly modulating the myenteric plexus and thus mimicking meal ingestion, we induce peristalsis in a fasted state and achieve a metabolic response commensurate with a fed or satiated state. This neuroprosthesis and implantation platform expand opportunities in fundamental studies and treatments of metabolic and neuromuscular pathologies affecting the GI tract.
Cell Reports · May 2025
Brandon M. Ruszala, Marc H. Schieber
Abstract
Although control of movement involves many cortical association areas, bidirectional brain-machine interfaces (BMIs) typically decode movement intent from the motor cortex and deliver feedback information to the primary somatosensory cortex (S1). Compared to the S1, the parietal and premotor areas encode more complex information about object properties, hand pre-shaping, and reach trajectories. BMIs therefore might deliver richer information to those cortical association areas than to primary areas. Here, we investigated whether instructions for a center-out task could be delivered via intracortical microstimulation (ICMS) in the anterior intraparietal area (AIP), dorsal posterior parietal cortex (dPPC), or dorsal premotor cortex (PMd) as well as the ventral premotor cortex (PMv) and S1. Two monkeys successfully learned to use AIP, PMv, or S1-ICMS instructions, but neither learned to use dPPC- or PMd-ICMS instructions. The AIP, PMv, and S1 may thus be effective cortical territory for delivering information to the brain, whereas the dPPC or PMd may be comparatively ineffective.
STAR Protocols · Mar 2024
Léo Choinière, Rose Guay-Hottin, Rémi Picard, … Numa Dancause
Abstract
Effective neural stimulation requires adequate parametrization. Gaussian-process (GP)-based Bayesian optimization (BO) offers a framework to discover optimal stimulation parameters in real time. Here, we first provide a general protocol to deploy this framework in neurostimulation interventions and follow by exemplifying its use in detail. Specifically, we describe the steps to implant rats with multi-channel electrode arrays in the hindlimb motor cortex. We then detail how to utilize the GP-BO algorithm to maximize evoked target movements, measured as electromyographic responses. For complete details on the use and execution of this protocol, please refer to Bonizzato and colleagues (2023).1.
Micromachines · Feb 2024
Aritra Kundu, Erin Patrick, Seth Currlin, … Rizwan Bashirullah
Abstract
Compound nerve action potentials (CNAPs) were used as a metric to assess the stimulation performance of a novel high-density, transverse, intrafascicular electrode in rat models. We show characteristic CNAPs recorded from distally implanted cuff electrodes. Evaluation of the CNAPs as a function of stimulus current and calculation of recruitment plots were used to obtain a qualitative approximation of the neural interface’s placement and orientation inside the nerve. This method avoids elaborate surgeries required for the implantation of EMG electrodes and thus minimizes surgical complications and may accelerate the healing process of the implanted subject.
Bioelectronic Medicine · Feb 2024
Valentina Paggi, Florian Fallegger, Ludovic Serex, … Stéphanie P. Lacour
Abstract
Background Cuff electrodes target various nerves throughout the body, providing neuromodulation therapies for motor, sensory, or autonomic disorders. However, when using standard, thick silicone cuffs, fabricated in discrete circular sizes, complications may arise, namely cuff displacement or nerve compression, due to a poor adaptability to variable nerve shapes and sizes encountered in vivo. Improvements in cuff design, materials, closing mechanism and surgical approach are necessary to overcome these issues. Methods In this work, we propose a microfabricated multi-channel silicone-based soft cuff electrode with a novel easy-to-implant and size-adaptable design and evaluate a number of essential features such as nerve-cuff contact, nerve compression, cuff locking stability, long-term integration and stimulation selectivity. We also compared performance to that of standard fixed-size cuffs. Results The belt-like cuff made of 150 μm thick silicone membranes provides a stable and pressure-free conformal contact, independently of nerve size variability, combined with a straightforward implantation procedure. The adaptable design and use of soft materials lead to limited scarring and demyelination after 6-week implantation. In addition, multi-contact designs, ranging from 6 to 16 electrodes, allow for selective stimulation in models of rat and pig sciatic nerve, achieving targeted activation of up to 5 hindlimb muscles. Conclusion These results suggest a promising alternative to classic fixed-diameter cuffs and may facilitate the adoption of soft, adaptable cuffs in clinical settings.
iScience · Mar 2023
Matias Lorenzo Cavelli, Rong Mao, Graham Findlay, … Chiara Cirelli
Abstract
In humans, the level of consciousness is assessed by quantifying the spatiotemporal complexity of cortical responses using Perturbational Complexity Index (PCI) and related PCIst (st, state transitions). Here we validate PCIst in freely moving rats and mice by showing that it is lower in NREM sleep and slow wave anesthesia than in wake or REM sleep, as in humans. We then show that (1) low PCIst is associated with the occurrence of an OFF period of neuronal silence; (2) stimulation of deep, but not superficial, cortical layers leads to reliable PCIst changes across sleep/wake and anesthesia; (3) consistent PCIst changes are independent of which single area is being stimulated or recorded, except for recordings in mouse prefrontal cortex. These experiments show that PCIst can reliably measure vigilance states in unresponsive animals and support the hypothesis that it is low when an OFF period disrupts causal interactions in cortical networks.
bioRxiv · Mar 2021
Vivien Gaillet, Elodie Geneviève Zollinger, Diego Ghezzi
Abstract
Objective Optic nerve’s intraneural stimulation is an emerging neuroprosthetic approach to provide artificial vision to totally blind patients. An open question is the possibility to evoke individual non-overlapping phosphenes via selective intraneural optic nerve stimulation. To begin answering this question, first, we aim at showing in preclinical experiments with animals that each intraneural electrode could evoke a distinguishable activity pattern in the primary visual cortex. Approach We performed both patterned visual stimulation and patterned electrical stimulation in healthy rabbits while recording evoked cortical activity with an electrocorticogram array in the primary visual cortex. Electrical stimulation was delivered to the optic nerve with the intraneural array OpticSELINE. We used a support vector machine algorithm paired to a linear regression model to classify cortical responses originating from visual stimuli located in different portions of the visual field and electrical stimuli from the different electrodes of the OpticSELINE. Main results Cortical activity induced by visual and electrical stimulation could be classified with nearly 100% accuracy relative to the specific location in the visual field or electrode in the array from which it originated. For visual stimulation, the accuracy increased with the separation of the stimuli and reached 100% for separation higher than 7 degrees. For electrical stimulation, at low current amplitudes, the accuracy increased with the distance between electrodes, while at higher current amplitudes, the accuracy was nearly 100% already for the shortest separation. Significance Optic nerve’s intraneural stimulation with the OpticSELINE induced discernible cortical activity patterns. These results represent a leap forward for intraneural optic nerve stimulation towards artificial vision.
Frontiers in Neuroscience · Feb 2021
Matthew T. Flavin, Marek A. Paul, Alexander S. Lim, … Jongyoon Han
Abstract
For many peripheral neuro-modulation applications, the cuff electrode has become a preferred technology for delivering electrical current into targeted volumes of tissue. While basic cuffs with low spatial selectivity, having longitudinally arranged contacts, can be produced from relatively straightforward processes, the fabrication of more complex electrode configurations typically requires iterative design and clean-room fabrication with skilled technicians. Although facile methods for fabricating cuff electrodes exist, their inconsistent products have limited their adoption for rapid manufacturing. In this article, we report a fast, low-cost fabrication process for patterning of electrode contacts in an implantable peripheral nerve cuff. Using a laser cutter as we have prescribed, the designer can render precise contact geometries that are consistent between batches. This method is enabled by the use of silicone/carbon black (CB) composite electrodes, which integrate with the patterned surface of its substrate—tubular silicone insulation. The size and features of its products can be adapted to fit a wide range of nerve diameters and applications. In this study, we specifically documented the manufacturing and evaluation of circumpolar cuffs with radial arrays of three contacts for acute implantation on the rat sciatic nerve. As part of this method, we also detail protocols for verification—electrochemical characterization—and validation—electrophysiological evaluation—of implantable cuff electrodes. Applied to our circumpolar cuff electrode, we report favorable electrical characteristics. In addition, we report that it reproduces expected electrophysiological behaviors described in prior literature. No specialized equipment or fabrication experience was required in our production, and we encountered negligible costs relative to commercially available solutions. Since, as we demonstrate, this process generates consistent and precise electrode geometries, we propose that it has strong merits for use in rapid manufacturing.
Journal of NeuroEngineering and Rehabilitation · Jan 2021
David M. Page, Jacob A. George, Suzanne M. Wendelken, … Gregory A. Clark
Abstract
Background Electrical stimulation of residual afferent nerve fibers can evoke sensations from a missing limb after amputation, and bionic arms endowed with artificial sensory feedback have been shown to confer functional and psychological benefits. Here we explore the extent to which artificial sensations can be discriminated based on location, quality, and intensity. Methods We implanted Utah Slanted Electrode Arrays (USEAs) in the arm nerves of three transradial amputees and delivered electrical stimulation via different electrodes and frequencies to produce sensations on the missing hand with various locations, qualities, and intensities. Participants performed blind discrimination trials to discriminate among these artificial sensations. Results Participants successfully discriminated cutaneous and proprioceptive sensations ranging in location, quality and intensity. Performance was significantly greater than chance for all discrimination tasks, including discrimination among up to ten different cutaneous location-intensity combinations (15/30 successes, p < 0.0001) and seven different proprioceptive location-intensity combinations (21/40 successes, p < 0.0001). Variations in the site of stimulation within the nerve, via electrode selection, enabled discrimination among up to five locations and qualities (35/35 successes, p < 0.0001). Variations in the stimulation frequency enabled discrimination among four different intensities at the same location (13/20 successes, p < 0.0005). One participant also discriminated among individual stimulation of two different USEA electrodes, simultaneous stimulation on both electrodes, and interleaved stimulation on both electrodes (20/24 successes, p < 0.0001). Conclusion Electrode location, stimulation frequency, and stimulation pattern can be modulated to evoke functionally discriminable sensations with a range of locations, qualities, and intensities. This rich source of artificial sensory feedback may enhance functional performance and embodiment of bionic arms endowed with a sense of touch.
Aug 2020
Evan N Nicolai, Kip Ludwig
Abstract
This protocol was used to collect data now published in the Journal of Neural Engineering, Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs, see Metadata for citation. Additionally, the dataset is publicly available on Pennsieve 10.26275/qcuk-a8ty.
Cerebral Cortex · Jul 2016
Stephan Quessy, Sandrine L. Côté, Adjia Hamadjida, … Numa Dancause
Abstract
The ventral premotor cortex (PMv) is a key node in the neural network involved in grasping. One way PMv can carry out this function is by modulating the outputs of the primary motor cortex (M1) to intrinsic hand and forearm muscles. As many PMv neurons discharge when grasping with either arm, both PMv within the same hemisphere (ipsilateral; iPMv) and in the opposite hemisphere (contralateral; cPMv) could modulate M1 outputs. Our objective was to compare modulatory effects of iPMv and cPMv on M1 outputs to intrinsic hand and forearm muscles. We used paired-pulse protocols with intracortical microstimulations in capuchin monkeys. A conditioning stimulus was applied in either iPMv or cPMv simultaneously or prior to a test stimulus in M1 and the effects quantified in electromyographic signals. Modulatory effects from iPMv were predominantly facilitatory, and facilitation was much more common and powerful on intrinsic hand than forearm muscles. In contrast, while the conditioning of cPMv could elicit facilitatory effects, in particular to intrinsic hand muscles, it was much more likely to inhibit M1 outputs. These data show that iPMv and cPMv have very different modulatory effects on the outputs of M1 to intrinsic hand and forearm muscles.
PLoS ONE · Feb 2013
Oliver E. Flouty, Hiroyuki Oya, Hiroto Kawasaki, … Matthew A. Howard
Abstract
The efficacy of spinal cord stimulators is dependent on the ability of the device to functionally activate targeted structures within the spinal cord, while avoiding activation of near-by non-targeted structures. In theory, these objectives can best be achieved by delivering electrical stimuli directly to the surface of the spinal cord. The current experiments were performed to study the influence of different stimulating electrode positions on patterns of spinal cord electrophysiological activation. A custom-designed spinal cord neurostimulator was used to investigate the effects of lead position and stimulus amplitude on cortical electrophysiological responses to spinal cord stimulation. Brain recordings were obtained from subdural grids placed in four adult sheep. We systematically varied the position of the stimulating lead relative to the spinal cord and the voltage delivered by the device at each position, and then examined how these variables influenced cortical responses. A clear relationship was observed between voltage and electrode position, and the magnitude of high gamma-band oscillations. Direct stimulation of the dorsal column contralateral to the grid required the lowest voltage to evoke brain responses to spinal cord stimulation. Given the lower voltage thresholds associated with direct stimulation of the dorsal column, and its possible impact on the therapeutic window, this intradural modality may have particular clinical advantages over standard epidural techniques now in routine use.