Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

Trends in Hearing · 2026

When the First Pulse Fades: 75% Reduction in Precedence Effect in Cochlear Implanted Rats (opens in a new tab)

Alexa N Buck, Tim Fleiner, Nicole Rosskothen-Kuhl, Jan WH Schnupp

Abstract

It is widely known that users of cochlear implants (CIs) often show deficits in binaural hearing. In particular, interaural time difference (ITD) discrimination tends to be substantially worse in CI users. However, only very few studies have investigated how CI stimulation affects the “precedence effect” (PE), and how this might be affected by abnormal hearing experience during development. We performed behavioral experiments to measure temporal weighting functions (TWFs) to quantify the PE in three different cohorts of rats: normally hearing (NH) acoustically stimulated, neonatally deafened (ND) CI-stimulated, and adult deafened (AD) CI-stimulated animals. Lateralization responses were recorded to bursts of eight stimulus pulses in which the ITD of each pulse varied independently, and probit analysis revealed the perceptual weight of each pulse. The NH and ND-CI cohorts were tested at 50, 300, and 900 pps; the AD-CI animals were tested only at 300 pps. The NH animals show a pronounced “onset dominance” at higher pulse rates, that is, the weighting of the first pulse was much larger than for subsequent pulses, exactly as one would expect given previous studies on human listeners. In contrast, the TWFs for the ND-CI and AD-CI animals were much flatter, with a reduction of onset dominance by ∼75%, especially for higher pulse rates. Since neither of our CI cohorts had any experience of reverberation in their electric hearing, we interpret these results to indicate that the PE may require domain-specific experience to develop.

Advanced Science · Nov 2025

Interactions of Interaural Time and Level Differences in Spatial Hearing with Cochlear Implants (opens in a new tab)

Sarah Buchholz, Susan Arndt, Jan W. H. Schnupp, Nicole Rosskothen‐Kuhl

Abstract

Normally hearing humans can localize sound sources quite accurately, with minimum audible angles as small as 1°. To achieve this, these auditory pathways combine information from multiple acoustic cues, including interaural time and interaural level differences (ITDs and ILDs). Patients relying on cochlear implants (CIs) to hear the world do not match normal performance. These deficits are most pronounced in patients with little or no hearing experience early in life, and they appear to result from impaired sensitivity to ITDs, but not to ILDs. However, little is known about how ITD and ILD sensitivities develop and interact in an early deafened auditory system shortly after CI implantation. Neonatally deafened rats were fitted with bilateral CIs, and, providing informative ITDs and ILDs from stimulation onset, were trained to lateralize CI stimuli. These animals are exquisitely sensitive to both ILDs and ITDs of CI stimulus pulses, and combined information from both cues in a weighted sum. Importantly, ITDs are weighted heavily in the CI rats, such that only very modest ITDs pointing in one direction can confound quite large ILDs pointing in the opposite direction. This underlines the importance of informative ITDs for maximizing the potential for spatial hearing with CI devices.

Scientific Reports · Dec 2024

Interaural level difference sensitivity in neonatally deafened rats fitted with bilateral cochlear implants (opens in a new tab)

Sarah Buchholz, Jan W. H. Schnupp, Susan Arndt, Nicole Rosskothen-Kuhl

Abstract

Bilateral cochlear implant (CI) patients exhibit significant limitations in spatial hearing. Their ability to process interaural time differences (ITDs) is often impaired, while their ability to process interaural level differences (ILDs) remains comparatively good. Clinical studies aiming to identify the causes of these limitations are often plagued by confounds and ethical limitations. Recent behavioral work suggests that rats may be a good animal model for studying binaural hearing under neuroprosthetic stimulation, as rats develop excellent ITD sensitivity when provided with suitable CI stimulation. However, their ability to use ILDs has not yet been characterized. Objective of this study is to address this knowledge gap. Neontally deafened rats were bilaterally fitted with CIs, and trained to lateralize binaural stimuli according to ILD. Their behavioral ILD thresholds were measured at pulse rates from 50 to 2400 pps. CI rats exhibited high sensitivity to ILDs with thresholds of a few dB at all tested pulse rates. We conclude that early deafened rats develop good sensitivity, not only to ITDs but also to ILDs, if provided with appropriate CI stimulation. Their generally good performance, in line with expectations from other mammalian species, validates rats as an excellent model for research on binaural auditory prostheses.

Frontiers in Neuroscience · Feb 2024

Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant (opens in a new tab)

W. Mitchel Thomas, Steven A. Zuniga, Inderbir Sondh, … Meredith E. Adams

Abstract

Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.

bioRxiv · Feb 2024

Evaluating Cochlear Implant Stimulation Strategies Through Wide-field Calcium Imaging of the Auditory Cortex (opens in a new tab)

Bruno Castellaro, Tony Ka Wing Yip, Fei Peng, … Jan Schnupp

Abstract

Cochlear Implants (CI) are an effective neuroprosthesis for humans with profound hearing loss, enabling deaf adults to have phone calls without lipreading and babies to have successful language development. However, CIs have significant limitations in complex hearing situations, motivating the need for further research, including studies in animal models. Here, we demonstrate the usefulness of wide field Ca++ imaging in assessing different CI stimulation strategies. One major challenge in electrophysiology in CI animals lies in excluding the CI electric artifacts from the recording, since they are orders of magnitude larger than the amplitude of action potentials. Also, electrophysiology can rarely sample large areas of neuropil at high spatial resolution. To circumvent these problems, we have set up an imaging system allowing us to monitor neural activity in the auditory cortex (AC) of CI supplied rats using the Ca++ sensitive dye OGB. Here we describe an initial experiment with this setup, in which we recorded cortical responses to 4 different stimulation patterns which were delivered across 3 CI channels to the contralateral ear. We then investigated two parameters that have been shown to affect intelligibility in CI users: pulse rate and relative pulse timing across CI channels. While pulse rate had only a very modest effect on the discriminability of the neural responses, the stimulation mode had a major effect, with simultaneous pulse timing, perhaps surprisingly, allowing much better pattern discrimination than interleaved sampling. The result suggests that allowing collisions of pulses on neighboring channels may not always be detrimental, at least if partial overlaps of pulses, in which anodic and cathodic pulse phases might cancel, are avoided.

bioRxiv · Aug 2023

Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants? (opens in a new tab)

Jan W. H. Schnupp, Sarah Buchholz, Alexa N. Buck, … Nicole Rosskothen-Kuhl

Abstract

Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the “fine structure” ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance Statement CIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brain’s ability to process temporal sound features with sub-millisecond precision. CIs “sample” sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.

Scientific Reports · Mar 2023

Interaural time difference sensitivity under binaural cochlear implant stimulation persists at high pulse rates up to 900 pps (opens in a new tab)

Alexa N. Buck, Sarah Buchholz, Jan W. Schnupp, Nicole Rosskothen-Kuhl

Abstract

Spatial hearing remains one of the major challenges for bilateral cochlear implant (biCI) users, and early deaf patients in particular are often completely insensitive to interaural time differences (ITDs) delivered through biCIs. One popular hypothesis is that this may be due to a lack of early binaural experience. However, we have recently shown that neonatally deafened rats fitted with biCIs in adulthood quickly learn to discriminate ITDs as well as their normal hearing litter mates, and perform an order of magnitude better than human biCI users. Our unique behaving biCI rat model allows us to investigate other possible limiting factors of prosthetic binaural hearing, such as the effect of stimulus pulse rate and envelope shape. Previous work has indicated that ITD sensitivity may decline substantially at the high pulse rates often used in clinical practice. We therefore measured behavioral ITD thresholds in neonatally deafened, adult implanted biCI rats to pulse trains of 50, 300, 900 and 1800 pulses per second (pps), with either rectangular or Hanning window envelopes. Our rats exhibited very high sensitivity to ITDs at pulse rates up to 900 pps for both envelope shapes, similar to those in common clinical use. However, ITD sensitivity declined to near zero at 1800 pps, for both Hanning and rectangular windowed pulse trains. Current clinical cochlear implant (CI) processors are often set to pulse rates ≥ 900 pps, but ITD sensitivity in human CI listeners has been reported to decline sharply above ~ 300 pps. Our results suggest that the relatively poor ITD sensitivity seen at > 300 pps in human CI users may not reflect the hard upper limit of biCI ITD performance in the mammalian auditory pathway. Perhaps with training or better CI strategies good binaural hearing may be achievable at pulse rates high enough to allow good sampling of speech envelopes while delivering usable ITDs.

Scientific Reports · Feb 2023

Classification of electrically-evoked potentials in the parkinsonian subthalamic nucleus region (opens in a new tab)

Joshua Rosing, Alex Doyle, AnneMarie Brinda, … Matthew D. Johnson

Abstract

Electrically evoked compound action potentials (ECAPs) generated in the subthalamic nucleus (STN) contain features that may be useful for titrating deep brain stimulation (DBS) therapy for Parkinson’s disease. Delivering a strong therapeutic effect with DBS therapies, however, relies on selectively targeting neural pathways to avoid inducing side effects. In this study, we investigated the spatiotemporal features of ECAPs in and around the STN across parameter sweeps of stimulation current amplitude, pulse width, and electrode configuration, and used a linear classifier of ECAP responses to predict electrode location. Four non-human primates were implanted unilaterally with either a directional (n = 3) or non-directional (n = 1) DBS lead targeting the sensorimotor STN. ECAP responses were characterized by primary features (within 1.6 ms after a stimulus pulse) and secondary features (between 1.6 and 7.4 ms after a stimulus pulse). Using these features, a linear classifier was able to accurately differentiate electrodes within the STN versus dorsal to the STN in all four subjects. ECAP responses varied systematically with recording and stimulating electrode locations, which provides a subject-specific neuroanatomical basis for selecting electrode configurations in the treatment of Parkinson’s disease with DBS therapy.

bioRxiv · Apr 2022

Classification of electrically-evoked compound action potentials in the parkinsonian subthalamic nucleus region (opens in a new tab)

Joshua Rosing, Alex Doyle, AnneMarie Brinda, … Matthew D. Johnson

Abstract

Electrically evoked compound action potentials (ECAPs) generated in the subthalamic nucleus (STN) contain features that may be useful for titrating deep brain stimulation (DBS) therapy for Parkinson’s disease. Delivering a strong therapeutic effect with DBS therapies, however, relies on selectively targeting neural pathways to avoid inducing side effects. In this study, we investigated the spatiotemporal features of ECAPs in and around the STN across parameter sweeps of stimulation current amplitude, pulse width, and electrode configuration, and used a linear classifier of ECAP responses to predict electrode location. Four non-human primates were implanted unilaterally with either a directional (n=3) or non-directional (n=1) DBS lead targeting the sensorimotor STN. ECAP responses were characterized by primary features (within 1.6 ms after a stimulus pulse) and secondary features (between 1.6-7.4 ms after a stimulus pulse). Using these ECAP features, a linear classifier was able to accurately differentiate electrodes within the STN versus dorsal to the STN in all four subjects. ECAP responses varied systematically with recording and stimulating electrode locations, which provides a subject-specific neuroanatomical basis for selecting electrode configurations in the treatment of Parkinson’s disease with DBS therapy.

Frontiers in Neuroscience · Oct 2021

Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve (opens in a new tab)

Nikhil S. Chandra, Weston M. McCarron, Ying Yan, … Matthew R. MacEwan

Abstract

Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees’ truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE’s implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE’s suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present in vivo study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Approach: Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. Main Results: For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 μA (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve’s center were, on average, half those of leads located near the periphery (54.92 μA vs. 110.71 μA, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads’ thresholds decreased or remained stable over the 3-week span. The remaining two leads’ thresholds increased by 70–74%, possibly due to scarring or device failure. Significance: This work represents an important first step in establishing the MSE’s viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms.

eLife · Jan 2021

Microsecond interaural time difference discrimination restored by cochlear implants after neonatal deafness (opens in a new tab)

Nicole Rosskothen-Kuhl, Alexa N Buck, Kongyan Li, Jan WH Schnupp

Abstract

Spatial hearing in cochlear implant (CI) patients remains a major challenge, with many early deaf users reported to have no measurable sensitivity to interaural time differences (ITDs). Deprivation of binaural experience during an early critical period is often hypothesized to be the cause of this shortcoming. However, we show that neonatally deafened (ND) rats provided with precisely synchronized CI stimulation in adulthood can be trained to lateralize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, comparable ND rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. Our result that ND-CI rats achieved very good behavioral ITD thresholds, while prelingually deaf human CI patients often fail to develop a useful sensitivity to ITD raises urgent questions concerning the possibility that shortcomings in technology or treatment, rather than missing input during early development, may be behind the usually poor binaural outcomes for current CI patients.

Frontiers in Neuroscience · Jul 2020

Optimal Multichannel Artifact Prediction and Removal for Neural Stimulation and Brain Machine Interfaces (opens in a new tab)

Mina Sadeghi Najafabadi, Longtu Chen, Kelsey Dutta, … Monty A. Escabí

Abstract

Neural implants that deliver multi-site electrical stimulation to the nervous systems are no longer the last resort but routine treatment options for various neurological disorders. Multi-site electrical stimulation is also widely used to study nervous system function and neural circuit transformations. These technologies increasingly demand dynamic electrical stimulation and closed-loop feedback control for real-time assessment of neural function, which is technically challenging since stimulus-evoked artifacts overwhelm the small neural signals of interest. We report a novel and versatile artifact removal method that can be applied in a variety of settings, from single- to multi-site stimulation and recording and for current waveforms of arbitrary shape and size. The method capitalizes on linear electrical coupling between stimulating currents and recording artifacts, which allows us to estimate a multi-channel linear Wiener filter to predict and subsequently remove artifacts via subtraction. We confirm and verify the linearity assumption and demonstrate feasibility in a variety of recording modalities, including in vitro sciatic nerve stimulation, bilateral cochlear implant stimulation, and multi-channel stimulation and recording between the auditory midbrain and cortex. We demonstrate a vast enhancement in the recording quality with a typical artifact reduction of 25-40 dB. The method is efficient and can be scaled to arbitrary number of stimulus and recording sites, making it ideal for applications in large-scale arrays, closed-loop implants, and high-resolution multi-channel brain-machine interfaces.