Menu

Publications using the HB7

133 published studies used the HB7.

Scientific Data · Apr 2024

Single-unit data for sensory neuroscience: Responses from the auditory nerve of young-adult and aging gerbils (opens in a new tab)

Amarins N. Heeringa

Abstract

This dataset was collected to study the functional consequences of age-related hearing loss for the auditory nerve, which carries acoustic information from the periphery to the central auditory system. Using high-impedance glass electrodes, raw voltage traces and spike times were recorded from more than one thousand single fibres of the auditory nerve of young-adult, middle-aged, and old Mongolian gerbils raised in a quiet environment. The dataset contains not only responses to simple acoustic stimuli to characterize the fibres, but also to more complex stimuli, such as speech logatomes in background noise and Schroeder-phase stimuli. A software toolbox is provided to search through the dataset, to plot various analysed outcomes, and to give insight into the analyses. This dataset may serve as a valuable resource to test further hypotheses about age-related hearing loss. Additionally, it can aid in optimizing available computational models of the auditory system, which can contribute to, or eventually even fully replace, animal experiments.

Frontiers in Neuroscience · Apr 2024

Neuromagnetic representation of musical roundness in chord progressions (opens in a new tab)

Sophie D. Wöhrle, Christoph Reuter, André Rupp, Martin Andermann

Abstract

Introduction Musical roundness perception relies on consonance/dissonance within a rule-based harmonic context, but also on individual characteristics of the listener. The present work tackles these aspects in a combined psychoacoustic and neurophysiological study, taking into account participant’s musical aptitude. Methods Our paradigm employed cadence-like four-chord progressions, based on Western music theory. Chord progressions comprised naturalistic and artificial sounds; moreover, their single chords varied regarding consonance/dissonance and harmonic function. Thirty participants listened to the chord progressions while their cortical activity was measured with magnetoencephalography; afterwards, they rated the individual chord progressions with respect to their perceived roundness. Results Roundness ratings differed according to the degree of dissonance in the dominant chord at the progression’s third position; this effect was pronounced in listeners with high musical aptitude. Interestingly, a corresponding pattern occurred in the neuromagnetic N1m response to the fourth chord (i.e., at the progression’s resolution), again with somewhat stronger differentiation among musical listeners. The N1m magnitude seemed to increase during chord progressions that were considered particularly round, with the maximum difference after the final chord; here, however, the musical aptitude effect just missed significance. Discussion The roundness of chord progressions is reflected in participant’s psychoacoustic ratings and in their transient cortical activity, with stronger differentiation among listeners with high musical aptitude. The concept of roundness might help to reframe consonance/dissonance to a more holistic, gestalt-like understanding that covers chord relations in Western music.

Trends in Hearing · 2024

Development of a Phrase-Based Speech-Recognition Test Using Synthetic Speech (opens in a new tab)

Saskia Ibelings, Thomas Brand, Esther Ruigendijk, Inga Holube

Abstract

Speech-recognition tests are widely used in both clinical and research audiology. The purpose of this study was the development of a novel speech-recognition test that combines concepts of different speech-recognition tests to reduce training effects and allows for a large set of speech material. The new test consists of four different words per trial in a meaningful construct with a fixed structure, the so-called phrases. Various free databases were used to select the words and to determine their frequency. Highly frequent nouns were grouped into thematic categories and combined with related adjectives and infinitives. After discarding inappropriate and unnatural combinations, and eliminating duplications of (sub-)phrases, a total number of 772 phrases remained. Subsequently, the phrases were synthesized using a text-to-speech system. The synthesis significantly reduces the effort compared to recordings with a real speaker. After excluding outliers, measured speech-recognition scores for the phrases with 31 normal-hearing participants at fixed signal-to-noise ratios (SNR) revealed speech-recognition thresholds (SRT) for each phrase varying up to 4 dB. The median SRT was −9.1 dB SNR and thus comparable to existing sentence tests. The psychometric function's slope of 15 percentage points per dB is also comparable and enables efficient use in audiology. Summarizing, the principle of creating speech material in a modular system has many potential applications.

Trends in Hearing · 2024

Automated Measurement of Speech Recognition, Reaction Time, and Speech Rate and Their Relation to Self-Reported Listening Effort for Normal-Hearing and Hearing-Impaired Listeners Using various Maskers (opens in a new tab)

Inga Holube, Stefan Taesler, Saskia Ibelings, … Jasper Ooster

Abstract

In speech audiometry, the speech-recognition threshold (SRT) is usually established by adjusting the signal-to-noise ratio (SNR) until 50% of the words or sentences are repeated correctly. However, these conditions are rarely encountered in everyday situations. Therefore, for a group of 15 young participants with normal hearing and a group of 12 older participants with hearing impairment, speech-recognition scores were determined at SRT and at four higher SNRs using several stationary and fluctuating maskers. Participants’ verbal responses were recorded, and participants were asked to self-report their listening effort on a categorical scale (self-reported listening effort, SR-LE). The responses were analyzed using an Automatic Speech Recognizer (ASR) and compared to the results of a human examiner. An intraclass correlation coefficient of r = .993 for the agreement between their corresponding speech-recognition scores was observed. As expected, speech-recognition scores increased with increasing SNR and decreased with increasing SR-LE. However, differences between speech-recognition scores for fluctuating and stationary maskers were observed as a function of SNR, but not as a function of SR-LE. The verbal response time (VRT) and the response speech rate (RSR) of the listeners’ responses were measured using an ASR. The participants with hearing impairment showed significantly lower RSRs and higher VRTs compared to the participants with normal hearing. These differences may be attributed to differences in age, hearing, or both. With increasing SR-LE, VRT increased and RSR decreased. The results show the possibility of deriving a behavioral measure, VRT, measured directly from participants’ verbal responses during speech audiometry, as a proxy for SR-LE.

Scientific Reports · Aug 2023

Effect of diotic versus dichotic presentation on the pitch perception of tone complexes at medium and very high frequencies (opens in a new tab)

Hedwig E. Gockel, Robert P. Carlyon

Abstract

Difference limens for fundamental frequency (F0), F0DLs, are usually small for complex tones containing low harmonics that are resolved in the auditory periphery, but worsen when the rank of the lowest harmonic increases above about 6–8 and harmonics become less resolved. The traditional explanation for this, in terms of resolvability, has been challenged and an alternative explanation in terms of harmonic rank was suggested. Here, to disentangle the effects of resolvability and harmonic rank the complex tones were presented either diotically (all harmonics to both ears) or dichotically (even and odd harmonics to opposite ears); the latter increases resolvability but does not affect harmonic rank. F0DLs were measured for 14 listeners for complex tones containing harmonics 6–10 with F0s of 280 and 1400 Hz, presented diotically or dichotically. For the low F0, F0DLs were significantly lower for the dichotic than for the diotic condition. This is consistent with a benefit of increased resolvability of harmonics for F0 discrimination and extends previous results to harmonics as low as the sixth. In contrast, for the high F0, F0DLs were similar for the two presentation modes, adding to evidence for differences in pitch perception between tones with low-to-medium and very-high frequency content.

bioRxiv · Jun 2023

The auditory P2 evoked by speech sounds consists of two separate subcomponents (opens in a new tab)

Kurt Steinmetzger, André Rupp

Abstract

The P2 component of the auditory evoked potential is commonly thought to reflect acoustic stimulus properties as well as prior exposure to the materials, rather than change-related cortical activity. Here, we challenge this view by showing that the P2 is strongly increased in response to voice pitch changes with a stepwise pattern compared to changes in dynamic pitch contours typical for natural speech, and also reflects the magnitude of these pitch changes. Furthermore, it is demonstrated that neither the P2 nor any other component are affected by the harmonicity of the materials. Despite no prior exposure, artificially created inharmonic versions of the speech materials elicited similar activity throughout auditory cortex. This suggests that so-called harmonic template neurons observed in animal studies are either absent or do not exist in sufficient number in human auditory cortex to detect their activity extracranially. Crucially, both morphology and source reconstructions of the EEG data showed that the P2 appears to consist of two separate subcomponents. Whereas source activity for the “P2a” was strongest in right auditory cortex, the subsequent “P2b” included generators spread across auditory cortex and association areas, bilaterally. The two subcomponents thus likely reflect processing at different stages of the auditory pathway.

The Cerebellum · Jan 2023

Altered binaural hearing in pre-ataxic and ataxic mutation carriers of spinocerebellar ataxia type 3 (opens in a new tab)

Heike Jacobi, Martin Andermann, Jennifer Faber, … André Rupp

Abstract

Brainstem degeneration is a prominent feature of spinocerebellar ataxia type 3 (SCA3), involving structures that execute binaural synchronization with microsecond precision. As a consequence, auditory processing may deteriorate during the course of disease. We tested whether the binaural “Huggins pitch” effect is suitable to study the temporal precision of brainstem functioning in SCA3 mutation carriers. We expected that they would have difficulties perceiving Huggins pitch at high frequencies, and that they would show attenuated neuromagnetic responses to Huggins pitch. The upper limit of Huggins pitch perception was psychoacoustically determined in 18 pre-ataxic and ataxic SCA3 mutation carriers and in 18 age-matched healthy controls. Moreover, the cortical N100 response following Huggins pitch onset was acquired by means of magnetoencephalography (MEG). MEG recordings were analyzed using dipole source modeling and comprised a monaural pitch condition and a no-pitch condition with simple binaural correlation changes. Compared with age-matched controls, ataxic but not pre-ataxic SCA3 mutation carriers had significantly lower frequency limits up to which Huggins pitch could be heard. Listeners with lower frequency limits also showed diminished MEG responses to Huggins pitch, but not in the two control conditions. Huggins pitch is a promising tool to assess brainstem functioning in ataxic SCA3 patients. Future studies should refine the psychophysiological setup to capture possible performance decrements also in pre-ataxic mutation carriers. Longitudinal observations will be needed to prove the potential of the assessment of Huggins pitch as a biomarker to track brainstem functioning during the disease course in SCA3.

Frontiers in Neuroscience · Jan 2023

Aging alters across-hemisphere cortical dynamics during binaural temporal processing (opens in a new tab)

Ann Clock Eddins, Erol J. Ozmeral, David A. Eddins

Abstract

Differences in the timing and intensity of sounds arriving at the two ears provide fundamental binaural cues that help us localize and segregate sounds in the environment. Neural encoding of these cues is commonly represented asymmetrically in the cortex with stronger activation in the hemisphere contralateral to the perceived spatial location. Although advancing age is known to degrade the perception of binaural cues, less is known about how the neural representation of such cues is impacted by age. Here, we use electroencephalography (EEG) to investigate age-related changes in the hemispheric distribution of interaural time difference (ITD) encoding based on cortical auditory evoked potentials (CAEPs) and derived binaural interaction component (BIC) measures in ten younger and ten older normal-hearing adults. Sensor-level analyses of the CAEP and BIC showed age-related differences in global field power, where older listeners had significantly larger responses than younger for both binaural metrics. Source-level analyses showed hemispheric differences in auditory cortex activity for left and right lateralized stimuli in younger adults, consistent with a contralateral activation model for processing ITDs. Older adults, however, showed reduced hemispheric asymmetry across ITDs, despite having overall larger responses than younger adults. Further, when averaged across ITD condition to evaluate changes in cortical asymmetry over time, there was a significant shift in laterality corresponding to the peak components (P1, N1, P2) in the source waveform that also was affected by age. These novel results demonstrate across-hemisphere cortical dynamics during binaural temporal processing that are altered with advancing age.

American journal of translational research · 2023

Metformin induces M2 polarization via AMPK/PGC-1/PPAR- pathway to improve peripheral nerve regeneration (opens in a new tab)

Zhou Z, Luo G, Li C

Abstract

Objectives: Investigating the effect of metformin on peripheral nerve regeneration and the molecular mechanism. Methods: In this study, a rat model of sciatic nerve injury and an inflammatory bone marrow-derived macrophage (BMDM) cell model were established. We assessed the sensory and motor function of the hind limbs four weeks after sciatic nerve injury, immunofluorescence was used to detect axonal regeneration and myelin formation, as well as local macrophage subtypes. We investigated the polarizing effect of metformin on inflammatory macrophages, and western blotting was applied to detect the molecular mechanisms behind it. Results: Metformin treatment accelerated functional recovery, axon regeneration and remyelination, and promoted M2 macrophage polarization. In vivo, metformin transformed pro-inflammatory macrophages into pro-regeneration M2 macrophages. Protein expression levels of phosphorylated AMP-activated protein kinase (p-AMPK), proliferator-activated receptor-γ co-activator 1α (PGC-1α), and peroxisome proliferator-activated receptor-γ (PPAR-γ) increased upon metformin treatment. Moreover, inhibition of AMPK abolished the effects of metformin treatment on M2 polarization. Conclusion: Metformin promoted M2 macrophage polarization by activating the AMPK/PGC-1α/PPAR-γ signaling axis, thereby promoting peripheral nerve regeneration.

Journal of the Association for Research in Otolaryngology · Dec 2022

Electrophysiological and Psychophysical Measures of Temporal Pitch Sensitivity in Normal-hearing Listeners (opens in a new tab)

François Guérit, Andrew J. Harland, Matthew L. Richardson, … Robert P. Carlyon

Abstract

To obtain combined behavioural and electrophysiological measures of pitch perception, we presented harmonic complexes, bandpass filtered to contain only high-numbered harmonics, to normal-hearing listeners. These stimuli resemble bandlimited pulse trains and convey pitch using a purely temporal code. A core set of conditions consisted of six stimuli with baseline pulse rates of 94, 188 and 280 pps, filtered into a HIGH (3365–4755 Hz) or VHIGH (7800–10,800 Hz) region, alternating with a 36% higher pulse rate. Brainstem and cortical processing were measured using the frequency following response (FFR) and auditory change complex (ACC), respectively. Behavioural rate change difference limens (DLs) were measured by requiring participants to discriminate between a stimulus that changed rate twice (up-down or down-up) during its 750-ms presentation from a constant-rate pulse train. FFRs revealed robust brainstem phase locking whose amplitude decreased with increasing rate. Moderate-sized but reliable ACCs were obtained in response to changes in purely temporal pitch and, like the psychophysical DLs, did not depend consistently on the direction of rate change or on the pulse rate for baseline rates between 94 and 280 pps. ACCs were larger and DLs lower for stimuli in the HIGH than in the VHGH region. We argue that the ACC may be a useful surrogate for behavioural measures of rate discrimination, both for normal-hearing listeners and for cochlear-implant users. We also showed that rate DLs increased markedly when the baseline rate was reduced to 48 pps, and compared the behavioural and electrophysiological findings to recent cat data obtained with similar stimuli and methods.

PLOS ONE · Dec 2022

Cocktail party training induces increased speech intelligibility and decreased cortical activity in bilateral inferior frontal gyri. A functional near-infrared study (opens in a new tab)

Cosima Lanzilotti, Guillaume Andéol, Christophe Micheyl, Sébastien Scannella

Abstract

The human brain networks responsible for selectively listening to a voice amid other talkers remain to be clarified. The present study aimed to investigate relationships between cortical activity and performance in a speech-in-speech task, before (Experiment I) and after training-induced improvements (Experiment II). In Experiment I, 74 participants performed a speech-in-speech task while their cortical activity was measured using a functional near infrared spectroscopy (fNIRS) device. One target talker and one masker talker were simultaneously presented at three different target-to-masker ratios (TMRs): adverse, intermediate and favorable. Behavioral results show that performance may increase monotonically with TMR in some participants and failed to decrease, or even improved, in the adverse-TMR condition for others. On the neural level, an extensive brain network including the frontal (left prefrontal cortex, right dorsolateral prefrontal cortex and bilateral inferior frontal gyri) and temporal (bilateral auditory cortex) regions was more solicited by the intermediate condition than the two others. Additionally, bilateral frontal gyri and left auditory cortex activities were found to be positively correlated with behavioral performance in the adverse-TMR condition. In Experiment II, 27 participants, whose performance was the poorest in the adverse-TMR condition of Experiment I, were trained to improve performance in that condition. Results show significant performance improvements along with decreased activity in bilateral inferior frontal gyri, the right dorsolateral prefrontal cortex, the left inferior parietal cortex and the right auditory cortex in the adverse-TMR condition after training. Arguably, lower neural activity reflects higher efficiency in processing masker inhibition after speech-in-speech training. As speech-in-noise tasks also imply frontal and temporal regions, we suggest that regardless of the type of masking (speech or noise) the complexity of the task will prompt the implication of a similar brain network. Furthermore, the initial significant cognitive recruitment will be reduced following a training leading to an economy of cognitive resources.

Frontiers in Human Neuroscience · Oct 2022

Neuromagnetic representation of melodic contour processing in human auditory cortex (opens in a new tab)

Sabrina Taddeo, Martin Schulz, Martin Andermann, André Rupp

Abstract

The pattern of ups and downs in a sequence with varying pitch can be heard as a melodic contour. Contrary to single pitch, the neural representation of melodic contour information in the auditory cortex is rarely investigated, and it is not clear whether the processing entails a hemispheric asymmetry. The present magnetoencephalography study assessed the neuromagnetic responses of N = 18 normal-hearing adults to four-note sequences with fixed vs. varying pitch that were presented either monaurally or diotically; data were analyzed using minimum-norm reconstructions. The first note of the sequences elicited prominent transient activity in posterior auditory regions (Planum temporale), especially contralateral to the ear of entry. In contrast, the response to the subsequent notes originated from more anterior areas (Planum polare) and was larger for melodic contours than for fixed pitch sequences, independent from the ear of entry and without hemispheric asymmetry. Together, the results point to a gradient in the early cortical processing of melodic contours, both in spatial and functional terms, where posterior auditory activity reflects the onset of a pitch sequence and anterior activity reflects its subsequent notes, including the difference between sequences with fixed pitch and melodic contours.

Frontiers in Neuroscience · Oct 2022

A biologically oriented algorithm for spatial sound segregation (opens in a new tab)

Kenny F. Chou, Alexander D. Boyd, Virginia Best, … Kamal Sen

Abstract

Listening in an acoustically cluttered scene remains a difficult task for both machines and hearing-impaired listeners. Normal-hearing listeners accomplish this task with relative ease by segregating the scene into its constituent sound sources, then selecting and attending to a target source. An assistive listening device that mimics the biological mechanisms underlying this behavior may provide an effective solution for those with difficulty listening in acoustically cluttered environments (e.g., a cocktail party). Here, we present a binaural sound segregation algorithm based on a hierarchical network model of the auditory system. In the algorithm, binaural sound inputs first drive populations of neurons tuned to specific spatial locations and frequencies. The spiking response of neurons in the output layer are then reconstructed into audible waveforms via a novel reconstruction method. We evaluate the performance of the algorithm with a speech-on-speech intelligibility task in normal-hearing listeners. This two-microphone-input algorithm is shown to provide listeners with perceptual benefit similar to that of a 16-microphone acoustic beamformer. These results demonstrate the promise of this biologically inspired algorithm for enhancing selective listening in challenging multi-talker scenes.

Audiology Research · Oct 2022

Congenital Nonprofound Bilateral Sensorineural Hearing Loss in Children: Comprehensive Characterization of Auditory Function and Hearing Aid Benefit (opens in a new tab)

Erik Berninger, Maria Drott, Mircea Romanitan, … Sten Hellström

Abstract

A prospective cross-sectional design was used to characterize congenital bilateral sensorineural hearing loss (SNHL). The underlying material of >30,000 consecutively screened newborns comprised 11 subjects with nonprofound, alleged nonsyndromic, SNHL. Comprehensive audiological testing was performed at ≈11 years of age. Results showed symmetrical sigmoid-like median pure-tone thresholds (PTTs) reaching 50–60 dB HL. The congenital SNHL revealed recruitment, increased upward spread of masking, distortion product otoacoustic emission (DPOAE) dependent on PTT (≤60 dB HL), reduced auditory brainstem response (ABR) amplitude, and normal magnetic resonance imaging. Unaided recognition of speech in spatially separate competing speech (SCS) deteriorated with increasing uncomfortable loudness level (UCL), plausibly linked to reduced afferent signals. Most subjects demonstrated hearing aid (HA) benefit in a demanding laboratory listening situation. Questionnaires revealed HA benefit in real-world listening situations. This functional characterization should be important for the outline of clinical guidelines. The distinct relationship between DPOAE and PTT, up to the theoretical limit of cochlear amplification, and the low ABR amplitude remain to be elucidated. The significant relation between UCL and SCS has implications for HA-fitting. The fitting of HAs based on causes, mechanisms, and functional characterization of the SNHL may be an individualized intervention approach and deserves future research.

Frontiers in Neuroscience · Aug 2022

Spectral and binaural loudness summation of equally loud narrowband signals in single-sided-deafness and bilateral cochlear implant users (opens in a new tab)

Hongmei Hu, Laura Hartog, Birger Kollmeier, Stephan D. Ewert

Abstract

Recent studies on loudness perception of binaural broadband signals in hearing impaired listeners found large individual differences, suggesting the use of such signals in hearing aid fitting. Likewise, clinical cochlear implant (CI) fitting with narrowband/single-electrode signals might cause suboptimal loudness perception in bilateral and bimodal CI listeners. Here spectral and binaural loudness summation in normal hearing (NH) listeners, bilateral CI (biCI) users, and unilateral CI (uCI) users with normal hearing in the unaided ear was investigated to assess the relevance of binaural/bilateral fitting in CI users. To compare the three groups, categorical loudness scaling was performed for an equal categorical loudness noise (ECLN) consisting of the sum of six spectrally separated third-octave noises at equal loudness. The acoustical ECLN procedure was adapted to an equivalent procedure in the electrical domain using direct stimulation. To ensure the same broadband loudness in binaural measurements with simultaneous electrical and acoustical stimulation, a modified binaural ECLN was introduced and cross validated with self-adjusted loudness in a loudness balancing experiment. Results showed a higher (spectral) loudness summation of the six equally loud narrowband signals in the ECLN in CI compared to NH. Binaural loudness summation was found for all three listener groups (NH, uCI, and biCI). No increased binaural loudness summation could be found for the current uCI and biCI listeners compared to the NH group. In uCI loudness balancing between narrowband signals and single electrodes did not automatically result in a balanced loudness perception across ears, emphasizing the importance of binaural/bilateral fitting.

Journal of the Association for Research in Otolaryngology · Aug 2022

Could Tailored Chirp Stimuli Benefit Measurement of the Supra-threshold Auditory Brainstem Wave-I Response? (opens in a new tab)

Jessica de Boer, Alexander Hardy, Katrin Krumbholz

Abstract

Auditory brainstem responses (ABRs) to broadband clicks are strongly affected by dyssynchrony, or “latency dispersion”, of their frequency-specific cochlear contributions. Optimized chirp stimuli, designed to compensate for cochlear dispersion, can afford substantial increase in broadband ABR amplitudes, particularly for the prominent wave-V deflection. Reports on the smaller wave I, however, which may be useful for measuring cochlear synaptopathy, have been mixed. This study aimed to test previous claims that ABR latency dispersion differs between waves I and V, and between males and females, and thus that using wave- and/or sex-tailored chirps may provide more reliable wave-I benefit. Using the derived-band technique, we measured responses from frequency-restricted (one-octave-wide) cochlear regions to energy-matched click and chirp stimuli. The derived-band responses’ latencies were used to assess any wave- and/or sex-related dispersion differences across bands, and their amplitudes, to evaluate any within-band dispersion differences. Our results suggest that sex-related dispersion difference within the lowest-frequency cochlear regions (< 1 kHz), where dispersion is generally greatest, may be a predominant driver of the often-reported sex difference in broadband ABR amplitude. At the same time, they showed no systematic dispersion difference between waves I and V. Instead, they suggest that reduced chirp benefit on wave I may arise as a result of chirp-induced desynchronization of on- and off-frequency responses generated at the same cochlear places, and resultant reduction in response contributions from higher-frequency cochlear regions, to which wave I is thought to be particularly sensitive.

Frontiers in Aging Neuroscience · Jul 2022

Age-Related Changes in Interaural-Level-Difference-Based Across-Frequency Binaural Interference (opens in a new tab)

Matthew J. Goupell

PA5RP2.1HB7System 3Psychoacoustics
Abstract

Low-frequency interaural time differences and high-frequency interaural level differences (ILDs) are used to localize sounds in the horizontal plane. Older listeners appear to be worse at horizontal-plane sound localization to compared younger listeners, but little is understood about age-related changes to across-frequency binaural processing. This study investigated if the frequency dependence of across-frequency ILD processing is altered for older compared to younger listeners, which was done by using an across-frequency binaural interference task (when the interaural difference sensitivity for a target sound is decreased by a spectrally remote interfering sound with zero interaural differences). It was hypothesized that as listeners experience advancing age and age-related high-frequency hearing loss (i.e., presbycusis), they will demonstrate worse binaural performance and experience more across-channel binaural interference (because of age-related temporal processing deficits), and will increasingly be affected by interferers at lower frequencies (because of age-related hearing loss) when compared to younger listeners. There were 11 older (>65 yrs) and 20 younger (<30 yrs) listeners with normal to near-normal audiometric thresholds up to 2 kHz. They were tested using a left-right ILD lateralization discrimination task. Single-tone ILD discrimination thresholds and across-frequency binaural interference were measured at 0.5, 1, 2, 4, and 8 kHz. ILD thresholds and interference were about twice as large for older compared to younger listeners. Interferers ≤1 kHz produced 2–3 times as much across-frequency binaural interference for older compared to younger listeners. Hearing thresholds were significant predictors of single-tone ILD thresholds; in addition, both target and interferer hearing thresholds were significant predictors of binaural interference. The results suggest a reweighting of binaural information that occurs with advancing age and age-related high-frequency hearing loss. This evidence of plasticity may help explain some of the age-related changes in spatial-hearing abilities.

Journal of the Association for Research in Otolaryngology · Jun 2022

Tonotopic Selectivity in Cats and Humans: Electrophysiology and Psychophysics (opens in a new tab)

Francois Guérit, John C. Middlebrooks, Matthew L. Richardson, … Robert P. Carlyon

Abstract

We describe a scalp-recorded measure of tonotopic selectivity, the “cortical onset response” (COR) and compare the results between humans and cats. The COR results, in turn, were compared with psychophysical masked-detection thresholds obtained using similar stimuli and obtained from both species. The COR consisted of averaged responses elicited by 50-ms tone-burst probes presented at 1-s intervals against a continuous noise masker. The noise masker had a bandwidth of 1 or 1/8th octave, geometrically centred on 4000 Hz for humans and on 8000 Hz for cats. The probe frequency was either − 0.5, − 0.25, 0, 0.25 or 0.5 octaves re the masker centre frequency. The COR was larger for probe frequencies more distant from the centre frequency of the masker, and this effect was greater for the 1/8th-octave than for the 1-octave masker. This pattern broadly reflected the masked excitation patterns obtained psychophysically with similar stimuli in both species. However, the positive signal-to-noise ratio used to obtain reliable COR measures meant that some aspects of the data differed from those obtained psychophysically, in a way that could be partly explained by the upward spread of the probe’s excitation pattern. Our psychophysical measurements also showed that the auditory filter width obtained at 8000 Hz using notched-noise maskers was slightly wider in cat than previous measures from humans. We argue that although conclusions from COR measures differ in some ways from conclusions based on psychophysics, the COR measures provide an objective, noninvasive, valid measure of tonotopic selectivity that does not require training and that may be applied to acoustic and cochlear-implant experiments in humans and laboratory animals.

The Journal of the Acoustical Society of America · May 2022

Effects of stimulus naturalness and contralateral interferers on lexical bias in consonant identification (opens in a new tab)

Brian Roberts, Robert J. Summers, Peter J. Bailey

Abstract

Lexical bias is the tendency to perceive an ambiguous speech sound as a phoneme completing a word; more ambiguity typically causes greater reliance on lexical knowledge. A speech sound ambiguous between /g/ and /k/ is more likely to be perceived as /g/ before /ɪft/ and as /k/ before /ɪs/. The magnitude of this difference—the Ganong shift—increases when high cognitive load limits available processing resources. The effects of stimulus naturalness and informational masking on Ganong shifts and reaction times were explored. Tokens between /gɪ/ and /kɪ/ were generated using morphing software, from which two continua were created (“giss”–“kiss” and “gift”–“kift”). In experiment 1, Ganong shifts were considerably larger for sine- than noise-vocoded versions of these continua, presumably because the spectral sparsity and unnatural timbre of the former increased cognitive load. In experiment 2, noise-vocoded stimuli were presented alone or accompanied by contralateral interferers with constant within-band amplitude envelope, or within-band envelope variation that was the same or different across bands. The latter, with its implied spectro-temporal variation, was predicted to cause the greatest cognitive load. Reaction-time measures matched this prediction; Ganong shifts showed some evidence of greater lexical bias for frequency-varying interferers, but were influenced by context effects and diminished over time.

PLOS ONE · Feb 2022

Sound source localization patterns and bilateral cochlear implants: Age at onset of deafness effects (opens in a new tab)

Sean R. Anderson, Rachael Jocewicz, Alan Kan, … Ruth Y. Litovsky

Abstract

The ability to determine a sound’s location is critical in everyday life. However, sound source localization is severely compromised for patients with hearing loss who receive bilateral cochlear implants (BiCIs). Several patient factors relate to poorer performance in listeners with BiCIs, associated with auditory deprivation, experience, and age. Critically, characteristic errors are made by patients with BiCIs (e.g., medial responses at lateral target locations), and the relationship between patient factors and the type of errors made by patients has seldom been investigated across individuals. In the present study, several different types of analysis were used to understand localization errors and their relationship with patient-dependent factors (selected based on their robustness of prediction). Binaural hearing experience is required for developing accurate localization skills, auditory deprivation is associated with degradation of the auditory periphery, and aging leads to poorer temporal resolution. Therefore, it was hypothesized that earlier onsets of deafness would be associated with poorer localization acuity and longer periods without BiCI stimulation or older age would lead to greater amounts of variability in localization responses. A novel machine learning approach was introduced to characterize the types of errors made by listeners with BiCIs, making them simple to interpret and generalizable to everyday experience. Sound localization performance was measured in 48 listeners with BiCIs using pink noise trains presented in free-field. Our results suggest that older age at testing and earlier onset of deafness are associated with greater average error, particularly for sound sources near the center of the head, consistent with previous research. The machine learning analysis revealed that variability of localization responses tended to be greater for individuals with earlier compared to later onsets of deafness. These results suggest that early bilateral hearing is essential for best sound source localization outcomes in listeners with BiCIs.