TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

Journal of Experimental Biology · 2012

The sender-receiver matching hypothesis: support from the peripheral coding of acoustic features in songbirds (opens in a new tab)

Gall MD, Brierley LE, Lucas JR

SigGenAP2ABR/DPOAE
Abstract

The sender-receiver matching hypothesis predicts that species-specific features of vocalizations will be reflected in species-specific auditory processing. This hypothesis has most often been invoked to explain correlations between vocal frequency ranges and the frequency range of auditory sensitivity; however, it could apply to other structural features, such as the rise time of stimuli. We explored this hypothesis in five songbird species that vary in the rise times and frequency range of their vocalizations. We recorded auditory evoked potentials (AEPs) to onset and sustained portions of stimuli that varied in both frequency and rise time. AEPs are gross potentials generated in the auditory nerve and brainstem and measured from the scalp. We found that species with shorter rise times in their vocalizations had greater amplitude and shorter latency onset AEPs than species with longer rise times. We also found that species with lower frequency and/or more tonal vocalizations had stronger sustained AEPs that follow the sound pressure changes in the stimulus (i.e. frequency following responses) than species with higher frequency and/or less tonal vocalizations. This is the first study in songbirds to show that acoustic features such as rise time and tonality are reflected in peripheral auditory processing.

Seeing and Perceiving · 2012

Evidence for auditory-visual processing specific to biological motion (opens in a new tab)

Wuerger SM, Crocker-Buque A, Meyer GF

Abstract

Biological motion is usually associated with highly correlated sensory signals from more than one modality: an approaching human walker will not only have a visual representation, namely an increase in the retinal size of the walker's image, but also a synchronous auditory signal since the walker's footsteps will grow louder. We investigated whether the multisensorial processing of biological motion is subject to different constraints than ecologically invalid motion. Observers were presented with a visual point-light walker and/or synchronised auditory footsteps; the walker was either approaching the observer (looming motion) or walking away (receding motion). A scrambled point-light walker served as a control. Observers were asked to detect the walker's motion as quickly and as accurately as possible. In Experiment 1 we tested whether the reaction time advantage due to redundant information in the auditory and visual modality is specific for biological motion. We found no evidence for such an effect: the reaction time reduction was accounted for by statistical facilitation for both biological and scrambled motion. In Experiment 2, we dissociated the auditory and visual information and tested whether inconsistent motion directions across the auditory and visual modality yield longer reaction times in comparison to consistent motion directions. Here we find an effect specific to biological motion: motion incongruency leads to longer reaction times only when the visual walker is intact and recognisable as a human figure. If the figure of the walker is abolished by scrambling, motion incongruency has no effect on the speed of the observers' judgments. In conjunction with Experiment 1 this suggests that conflicting auditory-visual motion information of an intact human walker leads to interference and thereby delaying the response.

The Journal of the Acoustical Society of America · 2012

Effects of mid-frequency active sonar on hearing in fish (opens in a new tab)

Halvorsen MB, Zeddies DG, Ellison WT, … Popper AN

SigGenABR/DPOAE
Abstract

Caged fish were exposed to sound from mid-frequency active (MFA) transducers in a 5 × 5 planar array which simulated MFA sounds at received sound pressure levels of 210 dB SPL(re 1 μPa). The exposure sound consisted of a 2 s frequency sweep from 2.8 to 3.8 kHz followed by a 1 s tone at 3.3 kHz. The sound sequence was repeated every 25 s for five repetitions resulting in a cumulative sound exposure level (SEL(cum)) of 220 dB re 1 μPa(2) s. The cumulative exposure level did not affect the hearing sensitivity of rainbow trout, a species whose hearing range is lower than the frequencies in the presented MFA sound. In contrast, one cohort of channel catfish showed a statistically significant temporary threshold shift of 4-6 dB at 2300 Hz, but not at lower tested frequencies, whereas a second cohort showed no change. It is likely that this threshold shift resulted from the frequency spectrum of the MFA sound overlapping with the upper end of the hearing frequency range of the channel catfish. The observed threshold shifts in channel catfish recovered within 24 h. There was no mortality associated with the MFA sound exposure used in this test.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

Information transfer along the ventral auditory processing stream in the awake macaque (opens in a new tab)

Smith EH, Kellis SS, House PA, Greger B

Abstract

Few studies have examined the physiology of the auditory cortical processing streams in the context of information transfer among cortical areas. This study examines information transfer in two cortical areas in the ventral auditory processing stream in an awake macaque. We show conditional information examined over different durations of neural responses provides insight into the time scale and direction of cortical hierarchical processing.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

EEG-based detection of awakening from isoflurane anesthesia in rats (opens in a new tab)

Kortelainen J, Väyrynen E, Jia X, … Thakor N

System 3EEG/ECoG/EMG
Abstract

In animal studies, reliable measures for depth of anesthesia are frequently required. Previous findings suggest that the continuous depth of anesthesia indices developed for humans might not be adequate for rats whose EEG changes during anesthesia represent more of quick transitions between discrete states. In this paper, the automatic EEG-based detection of awakening from anesthesia was studied in rats. An algorithm based on Bayesian Information Criterion (BIC) is proposed for the assessment of the switch-like change in the signal characteristics occurring just before the awakening. The method was tested with EEGs recorded from ten rats recovering from isoflurane anesthesia. The algorithm was shown to be able to detect the sudden change in the EEG related to the moment of awakening with a precision comparable to careful visual inspection. Our findings suggest that monitoring such signal changes may offer an interesting alternative to the application of continuous depth of anesthesia indices when avoiding the awakening of the animal during e.g. a clinical experiment.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

Effect of hypothermia on the thalamocortical function in the rat model (opens in a new tab)

Maybhate A, Chen C, Thakor NV, Jia X

Abstract

Neuroprotective effects of hypothermia are well documented in many injuries of the central nervous system in animal models as well as clinical studies. However, the underlying mechanisms are not fully understood. An important yet unexplored background issue is the effect of hypothermic cooling on the regional functionality of the healthy CNS. In a pilot study with the rat model, we seek to characterize the effect of moderate bodily cooling on the thalamo-cortical (T-C) function. Multiunit activity (MUA) and local field potentials (LFPs) were recorded from the thalamus (VPL nucleus) and the somatosensory cortex (S1) for normothermic, mild hypothermic and mild hyperthermic conditions in healthy rats and the thalamo-cortical dynamics was characterized with Granger Causal Interaction (GCI). The GCI indicated that the thalamic driving of the cortical activity significantly increases in strength with bodily cooling and weakens with mild heating. These results could have important implications towards understanding of hypothermia.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

The use of a novel carbon nanotube coated microelectrode array for chronic intracortical recording and microstimulation (opens in a new tab)

Parker RA, Negi S, Davis T, … Greger B

Abstract

Micro-electrode arrays (MEAs) have been used in a variety of intracortical neural prostheses. While intracortical MEAs have demonstrated their utility in neural prostheses, in many cases MEA performance declines after several months to years of in vivo implantation. The application of carbon nanotubes (CNTs) may increase the functional longevity of intracortical MEAs through enhanced biocompatibility and charge injection properties. An MEA metalized with platinum (Pt) on all electrodes had a CNT coating applied to the electrodes on half of the array. This Pt/Pt-CNT MEA was implanted into feline motor cortex for >1 year. Recordings of action potentials and 1 kHz impedance measurements were made on all electrodes to evaluate device functionality. Additionally, electromyogram (EMG) responses were evoked using micro-stimulation via the MEA to measure device performance. These metrics were compared between Pt and Pt-CNT electrodes. There was no significant difference in the data acquisition or micro-stimulation performance of Pt and the Pt-CNT electrodes. However, impedances were lower on the Pt-CNT electrodes. These results demonstrate the functionality of CNT coatings during chronic in vivo implantation. The lower impedances suggest that for microstimulation applications CNT coatings may impart enhanced interface properties.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

A parametric study of intracortical microstimulation in behaving rats for the development of artificial sensory channels (opens in a new tab)

Semprini M, Bennicelli L, Vato A

Abstract

In the framework of developing new brain-machine interfaces, many valuable results have been obtained in understanding which features of neural activity can be used in controlling an external device. Somatosensory real-time feedback is crucial for motor planning and for executing "online" errors correction during the movement. In people with sensory motor disabilities cortical microstimulation can be used as sensory feedback to elicit an artificial sensation providing the brain with information about the external environment. Even if intracortical microstimulation (ICMS) is broadly used in several experiments, understanding the psychophysics of such artificial sensory channel is still an open issue. Here we present the results of a parametric study that aims to define which stimulation parameters are needed to create an artificial sensation. Behaving rats were trained to report by pressing a lever the presence of ICMS delivered through microwire electrodes chronically implanted in the barrel cortex. Psychometric curves obtained by varying pulse amplitude, pulse frequency and train duration, demonstrate that in freely moving animals the perception threshold of microstimulation increased with respect to previous studies with head-restrained rats.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

Comprehensive characterization of tungsten microwires in chronic neurocortical implants (opens in a new tab)

Prasad A, Xue QS, Sankar V, … Sanchez JC

Abstract

The long-term performance of chronic microelectrode array implants for neural ensemble recording is affected by temporal degradation in signal quality due to several factors including structural changes in the recording surface, electrical responses, and tissue immune reactivity. This study combines the information available from the temporal aggregation of both biotic and abiotic metrics to analyze and quantify the combined effects on long-term performance. Study of a 42-day implant showed there was a functional relationship between the measured impedance and the array neuronal yield. This was correlated with structural changes in the recording sites, microglial activation/degeneration, and elevation of a blood biochemical marker for axonal injury. We seek to elucidate the mechanisms of chronic microelectrode array failure through the study of the combined effects of these biotic and abiotic factors.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

Threshold analysis of a quasimonopolar stimulation paradigm in visual prosthesis (opens in a new tab)

Matteucci PB, Chen SC, Dodds C, … Suaning GJ

Abstract

The complexity of surgical implantation has always been a significant obstacle in the development of visual prosthetics. Implanting in the epi and sub-retinal spaces allows the prosthesis direct access to the retina, resulting in lower stimulation thresholds, potentially at the expense of robust mechanical stability and interface longevity. Implanting the stimulating electrode in the supra-choroidal space greatly simplifies surgery and improves mechanical stability. This is achieved at the cost of a higher activation threshold and reduced focus of the electric field at the target site of stimulation, given the increased distance between the stimulating electrodes and the target tissue. In order to contain the spread of the stimulating field, the authors proposed a hexagonal arrangement of return electrodes, at a further cost to the stimulation threshold over that of a monopolar stimulation paradigm. This study analyses the effect on activation thresholds of activating simultaneously the hexpolar guard electrodes and the distant monopolar return in what we have termed a quasimonopolar configuration. Results show that introducing a small element of monopolar stimulation significantly lowers the activation threshold otherwise required by a pure hexpolar return.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012

Brain-machine interface control of a robot arm using actor-critic rainforcement learning (opens in a new tab)

Pohlmeyer EA, Mahmoudi B, Geng S, … Sanchez JC

Abstract

Here we demonstrate how a marmoset monkey can use a reinforcement learning (RL) Brain-Machine Interface (BMI) to effectively control the movements of a robot arm for a reaching task. In this work, an actor-critic RL algorithm used neural ensemble activity in the monkey's motor cortext to control the robot movements during a two-target decision task. This novel approach to decoding offers unique advantages for BMI control applications. Compared to supervised learning decoding methods, the actor-critic RL algorithm does not require an explicit set of training data to create a static control model, but rather it incrementally adapts the model parameters according to its current performance, in this case requiring only a very basic feedback signal. We show how this algorithm achieved high performance when mapping the monkey's neural states (94%) to robot actions, and only needed to experience a few trials before obtaining accurate real-time control of the robot arm. Since RL methods responsively adapt and adjust their parameters, they can provide a method to create BMIs that are robust against perturbations caused by changes in either the neural input space or the output actions they generate under different task requirements or goals.

The Journal of Toxicological Sciences · 2012

Ototoxicity of cisplatin administered to guinea pigs via the round window membrane (opens in a new tab)

Li Xia, Zhengnong Chen, Shankai Yin

ES1 & EC1SigGenRA16BABioSigABR/DPOAE
Abstract

Animal models of ototoxicity represent an elementary tool in otolaryngologic research. Such models are usually created via the consecutive injection of ototoxic drugs or the co-administration of ethacrynic acid and low-dose ototoxic drugs. Injection via the round window membrane (RWM) is one approach that allows for local drug delivery into the inner ear. In this study, 47 guinea pigs received an injection of varying doses of cisplatin via the RWM, and data concerning the animals' auditory brainstem responses, hair cells, and spiral ganglion neurons were analyzed. Our results indicate the high efficiency and generally small reaction of the subjects, suggesting that the application of cisplatin via the RWM is an effective animal model for ototoxicity research.

Journal of Pharmacological Sciences · 2012

A Novel Animal Model of Hearing Loss Caused by Acute Endoplasmic Reticulum Stress in the Cochlea (opens in a new tab)

Yoshiaki Fujinami, Hideki Mutai, Kunio Mizutari, … Tatsuo Matsunaga

Abstract

Many stimuli such as ischemia, hypoxia, heat shock, amino acid starvation, and gene mutation, exhibit a cellular response called endoplasmic reticulum (ER) stress. ER stress induces expression of a series of genes, leading to cell survival or apoptosis. Previously, we found that in an animal model of hearing loss caused by acute mitochondrial dysfunction, several ER stress markers including C/EBP homologous protein were induced in the cochlear lateral wall. To elucidate the mechanism of hearing loss caused by ER stress, we established a novel animal model of hearing loss by perilymphatic perfusion of tunicamycin, an ER stress activator that inhibits N-acetylglucosamine transferases. Subacute and progressive hearing loss was observed at all sound frequencies studied, and stimulation of ER stress marker genes was noted in the cochlea. The outer hair cells were the most sensitive to ER stress in the cochlea. Electron microscopic analysis demonstrated degeneration of the subcellular organelles of the inner hair cells and nerve endings of the spiral ganglion cells. This newly established animal model of hearing loss from ER stress will provide additional insight into the mechanism of sensorineural hearing loss.

Acta Otorhinolaryngologica Italica : Organo Ufficiale della Societa Italiana di Otorinolaringologia e Chirurgia Cervico-facciale · 2012

Antioxidant treatment with coenzyme Q-ter in prevention of gentamycin ototoxicity in an animal model (opens in a new tab)

Fetoni AR, Eramo SL, Rolesi R

System 3ABR/DPOAE
Abstract

Aminoglycosides, such as gentamycin, are well known ototoxic agents. Toxicity occurs via an activation process involving the formation of an iron-gentamycin complex with free radical production. Antioxidants like Q-ter (a soluble formulation of coenzyme Q(10), CoQ(10)), can limit or prevent cellular ototoxic damage. The present study was designed to investigate the possible protective effects of Q-ter on gentamycin ototoxicity in albino guinea pigs (250-300 g). Animals were divided into five experimental groups: I, a sham control group given an intra-peritoneal (I.P.) injection of 0.5 ml saline (SHAM); II, gentamycin group (GM), treated with an injection of gentamycin (100 mg/ kg); III, gentamycin + Q-ter group (GM+Q-ter), treated with gentamycin (same dose as group II) and an I.P. injection of coenzyme Q(10) terclatrate (Q-ter) at 100 mg/kg body weight; IV, injected with gentamycin (100 mg/kg) plus saline; V, treated with Q-ter alone (100 mg/ kg). All animals were treated for 14 consecutive days. Auditory function was evaluated by recording auditory brainstem responses (ABR) at 15 and 30 days from the beginning of treatment. Morphological changes were analyzed by rhodamine-phalloidine staining. Gentamycin-induced progressive high-frequency hearing loss of 45-55 dB SPL. Q-ter therapy slowed and attenuated the progression of hearing loss, yielding a threshold shift of 20 dB. The significant loss of outer hair cells (OHCs) in the cochlear medio-basal turn in gentamycin-treated animals was not observed in the cochleae of animals protected with Q-ter. This study supports the hypothesis that Q-ter interferes with gentamycin-induced free radical formation, and suggests that it may be useful in protecting OHC function from aminoglycoside ototoxicity, thus reducing hearing loss.

Frontiers in Behavioral Neuroscience · 2012

Increased Entorhinal-Prefrontal Theta Synchronization Parallels Decreased Entorhinal-Hippocampal Theta Synchronization during Learning and Consolidation of Associative Memory (opens in a new tab)

Kaori Takehara-Nishiuchi, Geith Maal-Bared, Mark D. Morrissey

Abstract

Memories are thought to be encoded as a distributed representation in the neocortex. The medial prefrontal cortex (mPFC) has been shown to support the expression of memories that initially depend on the hippocampus (HPC), yet the mechanisms by which the HPC and mPFC access the distributed representations in the neocortex are unknown. By measuring phase synchronization of local field potential (LFP) oscillations, we found that learning initiated changes in neuronal communication of the HPC and mPFC with the lateral entorhinal cortex (LEC), an area that is connected with many other neocortical regions. LFPs were recorded simultaneously from the three brain regions while rats formed an association between an auditory stimulus (CS) and eyelid stimulation (US) in a trace eyeblink conditioning paradigm, as well as during retention 1 month following learning. Over the course of learning, theta oscillations in the LEC and mPFC became strongly synchronized following presentation of the CS on trials in which rats exhibited a conditioned response (CR), and this strengthened synchronization was also observed during remote retention. In contrast, CS-evoked theta synchronization between the LEC and HPC decreased with learning. Our results suggest that communication between the LEC and mPFC are strengthened with learning whereas the communication between the LEC and HPC are concomitantly weakened, suggesting that enhanced LEC-mPFC communication may be a neuronal correlate for theoretically proposed neocortical reorganization accompanying encoding and consolidation of a memory.

Behavioural Brain Research · 2012

Positive and negative ultrasonic social signals elicit opposing firing patterns in rat amygdala (opens in a new tab)

Ashwini J. Parsana, Nanxin Li, Thomas H. Brown

Abstract

Rat ultrasonic vocalizations (USVs) are ethologically-essential social signals. Under natural conditions, 22kHz USVs and 50kHz USVs are emitted in association with negative and positive emotional states, respectively. Our first experiment examined freezing behavior elicited in naïve Sprague-Dawley rats by a 22kHz USV, a 50kHz USV, and frequency-matched tones. None of the stimuli elicited freezing, which is the most commonly-used index of fear. The second experiment examined single-unit responses to these stimuli in the amygdala (AM), which is well-known for its role in innate and acquired fear responses. Among 127 well-discriminated single units, 82% were auditory-responsive. Elicited firing patterns were classified using a multi-dimensional scheme that included transient (phasic) responses to the stimulus onsets and/or offsets as well as sustained (tonic) responses during the stimulus. Tonic responses, which are not ordinarily evaluated in AM, were 4.4-times more common than phasic responses. The 22kHz stimuli tended to elicit tonic increases in the firing rates, whereas the 50kHz stimuli more often elicited tonic decreases in firing rates. These opposing tonic responses correspond with the ethological valence of USVs in the two frequency bands. Thus, a relatively-small sample of single-unit responses in AM furnished a more sensitive index of emotional valence than freezing behavior. Latency analysis suggested that stimuli in the two frequency bands are processed through different pathways to AM. One possible interpretation is that phasic responses in AM reflect the detection of a stimulus change, whereas tonic responses indicate the valence of the detected stimulus.

NeuroImage · 2012

Dynamic causal modeling with neural fields (opens in a new tab)

D.A. Pinotsis, R.J. Moran, K.J. Friston

Abstract

The aim of this paper is twofold: first, to introduce a neural field model motivated by a well-known neural mass model; second, to show how one can estimate model parameters pertaining to spatial (anatomical) properties of neuronal sources based on EEG or LFP spectra using Bayesian inference. Specifically, we consider neural field models of cortical activity as generative models in the context of dynamic causal modeling (DCM). This paper considers the simplest case of a single cortical source modeled by the spatiotemporal dynamics of hidden neuronal states on a bounded cortical surface or manifold. We build this model using multiple layers, corresponding to cortical lamina in the real cortical manifold. These layers correspond to the populations considered in classical (Jansen and Rit) neural mass models. This allows us to formulate a neural field model that can be reduced to a neural mass model using appropriate constraints on its spatial parameters. In turn, this enables one to compare and contrast the predicted responses from equivalent neural field and mass models respectively. We pursue this using empirical LFP data from a single electrode to show that the parameters controlling the spatial dynamics of cortical activity can be recovered, using DCM, even in the absence of explicit spatial information in observed data.