Journal of Signal Processing · 2012
Yano Y, Miyauchi R, Unoki M, et al.
Abstract
Auditory search experiments were conducted to investigate the detectability of target signals with regard to movements in temporal envelopes. The movements in the temporal envelopes of signals were defined as the mean value of slopes, i.e., the first-order approximation of the temporal envelopes. The movements were systematically controlled by band-pass filtering on the modulation spectrum of the signals. The movements of background signals in each target signal were set to be different from the movements between target and background signals. Stimuli were composed of different temporal envelopes with a noise carrier. 1/2-octave band-noise as a carrier was used in which the center frequency of the carrier was 1380 Hz. Participants were required to determine whether they heard the target signal with the background signals. The results obtained from auditory search experiments demonstrated that the detectability of each target signal could be improved when the movements of the target and background signals differed. The results revealed that the difference in the movements of the signals affected the detectability of the signals.
Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 2012
Wayne Giang, Catherine M. Burns
Abstract
Sonifications are auditory displays that can help operators monitor safety critical data. However, there are very few guidelines that describe the design of effective sonifications. Two parameters that may impact the effectiveness of a sonification are discriminability and perceived urgency. We designed and evaluated four sonifications which varied timbre and the presence of a redundant pulse rate mapping using measures based on discriminability and perceived urgency. Our results show that participants were faster in detecting changes in a simple pure-tone timbre when compared to a more complex but natural sounding propeller engine timbre. Perceived urgency was heavily influenced by the presence of a redundant pulse rate mapping that changed the tempo of the sonification. When the redundant mapping was present, participants rated that the sonification sounded more urgent than when the mapping was absent. Further examination of how context influences discriminability and perceived urgency can extend the findings of this study.
Digital Commons@Becker (Washington University School of Medicine) · 2012
Wieczorek SS
2012
J Andrus
Int. J. Asian Lang. Process. · 2012
J Yang, C Liu
2012
GC Gaines
2012
A Fassihizakeri
Exp Brain Res · 2012
JKE Steeves
Journal of Educational · 2012
JR Sullivan, LM Thibodeau
J. Neurosci · 2012
R Moore, AJ King
Proceedings of the · 2012
T Necciari, P Balazs, R Kronland-Martinet
The Journal of · 2012
S Jung, CW Bahk, MW Suh
Proc. LISTA 2012 · 2012
EN MacDonald, KG Munhall
injury · 2012
JY Chen, EJ Fu, PR Patel, … KA Moss
Journal of the Association for Research in Otolaryngology · 2012
Salt AN, Hartsock JJ, Gill RM, et al.
Abstract
Perilymph pharmacokinetics was investigated by a novel approach, in which solutions containing drug or marker were injected from a pipette sealed into the perilymphatic space of the lateral semi-circular canal (LSCC). The cochlear aqueduct provides the outlet for fluid flow so this procedure allows almost the entire perilymph to be exchanged. After wait times of up to 4 h the injection pipette was removed and multiple, sequential samples of perilymph were collected from the LSCC. Fluid efflux at this site results from cerebrospinal fluid (CSF) entry into the basal turn of scala tympani (ST) so the samples allow drug levels from different locations in the ear to be defined. This method allows the rate of elimination of substances from the inner ear to be determined more reliably than with other delivery methods in which drug may only be applied to part of the ear. Results were compared for the markers trimethylphenylammonium (TMPA) and fluorescein and for the drug dexamethasone (Dex). For each substance, the concentration in fluid samples showed a progressive decrease as the delay time between injection and sampling was increased. This is consistent with the elimination of substance from the ear with time. The decline with time was slowest for fluorescein, was fastest for Dex, with TMPA at an intermediate rate. Simulations of the experiments showed that elimination occurred more rapidly from scala tympani (ST) than from scala vestibuli (SV). Calculated elimination half-times from ST averaged 54.1, 24.5 and 22.5 min for fluorescein, TMPA and Dex respectively and from SV 1730, 229 and 111 min respectively. The elimination of Dex from ST occurred considerably faster than previously appreciated. These pharmacokinetic parameters provide an important foundation for understanding of drug treatments of the inner ear.
Baioenjiniaringu Koenkai koen ronbunshu/Baioenjiniaringu Kouenkai kouen rombunshuu/Ippan Shadan Hojin Nihon Kikai Gakkai Baioenjiniaringu Koenkai · 2012
Ikehara Y, Koyama S, MURAKOSHI M, et al.
The Journal of the Acoustical Society of America · 2012
Helms Tillery K, Brown CA, Bacon SP
Abstract
Cochlear implant users report difficulty understanding speech in both noisy and reverberant environments. Electric-acoustic stimulation (EAS) is known to improve speech intelligibility in noise. However, little is known about the potential benefits of EAS in reverberation, or about how such benefits relate to those observed in noise. The present study used EAS simulations to examine these questions. Sentences were convolved with impulse responses from a model of a room whose estimated reverberation times were varied from 0 to 1 sec. These reverberated stimuli were then vocoded to simulate electric stimulation, or presented as a combination of vocoder plus low-pass filtered speech to simulate EAS. Monaural sentence recognition scores were measured in two conditions: reverberated speech and speech in a reverberated noise. The long-term spectrum and amplitude modulations of the noise were equated to the reverberant energy, allowing a comparison of the effects of the interferer (speech vs noise). Results indicate that, at least in simulation, (1) EAS provides significant benefit in reverberation; (2) the benefits of EAS in reverberation may be underestimated by those in a comparable noise; and (3) the EAS benefit in reverberation likely arises from partially preserved cues in this background accessible via the low-frequency acoustic component.
Journal of Experimental Biology · 2012
Higgs DM, Radford CA
Abstract
In the underwater environment, sound propagates both as a pressure wave and as particle displacement, with particle displacement dominating close to the source (the nearfield). At the receptor level, both the fish ear and the neuromast hair cells act as displacement detectors and both are potentially stimulated by the particle motion component of sound sources, especially in the nearfield. A now common way to test 'hearing' in fish involves auditory evoked potentials (AEPs), with recordings made from electrodes implanted near the auditory brainstem. These AEP recordings are typically conducted in enclosed acoustic environments with the fish well within the nearfield, especially for lower frequencies. We tested the contribution of neuromast hair cells to AEP by first testing intact goldfish (Carassius auratus), then ablating their neuromasts with streptomycin sulphate--disabling superficial and canal neuromasts--and retesting the same goldfish. We performed a similar experiment where only the superficial neuromasts were physically ablated. At 100 and 200 Hz, there was a 10-15 dB increase in threshold after streptomycin treatment but no significant difference at higher frequencies. There was no difference in threshold in control fish or in fish that only had superficial neuromasts removed, indicating that the differential responses were driven by canal neuromasts. Taken together, these results indicate that AEP results at lower frequencies should be interpreted as multimodal responses, rather than as 'hearing'. The results also suggest that in natural situations both the ear and lateral line likely play an integrative role in detecting and localising many types of 'acoustic' stimuli.
Journal of Experimental Biology · 2012
Christensen CB, Christensen-Dalsgaard J, Brandt C, Madsen PT
Abstract
Snakes lack both an outer ear and a tympanic middle ear, which in most tetrapods provide impedance matching between the air and inner ear fluids and hence improve pressure hearing in air. Snakes would therefore be expected to have very poor pressure hearing and generally be insensitive to airborne sound, whereas the connection of the middle ear bone to the jaw bones in snakes should confer acute sensitivity to substrate vibrations. Some studies have nevertheless claimed that snakes are quite sensitive to both vibration and sound pressure. Here we test the two hypotheses that: (1) snakes are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons, and possibly all snakes, lost effective pressure hearing with the complete reduction of a functional outer and middle ear, but have an acute vibration sensitivity that may be used for communication and detection of predators and prey.
Journal of Experimental Biology · 2012
Radford CA, Montgomery JC, Caiger PE, et al.
Abstract
The auditory evoked potential technique has been used for the past 30 years to evaluate the hearing ability of fish. The resulting audiograms are typically presented in terms of sound pressure (dB re. 1 μPa) with the particle motion (dB re. 1 m s(-2)) component largely ignored until recently. When audiograms have been presented in terms of particle acceleration, one of two approaches has been used for stimulus characterisation: measuring the pressure gradient between two hydrophones or using accelerometers. With rare exceptions these values are presented from experiments using a speaker as the stimulus, thus making it impossible to truly separate the contribution of direct particle motion and pressure detection in the response. Here, we compared the particle acceleration and pressure auditory thresholds of three species of fish with differing hearing specialisations, goldfish (Carassius auratus, weberian ossicles), bigeye (Pempheris adspersus, ligamentous hearing specialisation) and a third species with no swim bladder, the common triplefin (Forstergyian lappillum), using three different methods of determining particle acceleration. In terms of particle acceleration, all three fish species have similar hearing thresholds, but when expressed as pressure thresholds goldfish are the most sensitive, followed by bigeye, with triplefin the least sensitive. It is suggested here that all fish have a similar ability to detect the particle motion component of the sound field and it is their ability to transduce the pressure component of the sound field to the inner ear via ancillary hearing structures that provides the differences in hearing ability. Therefore, care is needed in stimuli presentation and measurement when determining hearing ability of fish and when interpreting comparative hearing abilities between species.