Menu

Electrophysiology publications

Neural recordings made with TDT systems: single units, local field potentials, EEG, ECoG and EMG.

Frontiers in Neuroscience · Apr 2021

Similar EEG Activity Patterns During Experimentally-Induced Auditory Illusions and Veridical Perceptions (opens in a new tab)

Maryam Faramarzi, Florian H. Kasten, Gamze Altaş, … Christoph S. Herrmann

Abstract

Hallucinations and illusions are two instances of perceptual experiences illustrating how perception might diverge from external sensory stimulations and be generated or altered based on internal brain states. The occurrence of these phenomena is not constrained to patient populations. Similar experiences can be elicited in healthy subjects by means of suitable experimental procedures. Studying the neural mechanisms underlying these experiences not only has the potential to expand our understanding of the brain’s perceptual machinery but also of how it might get impaired. In the current study, we employed an auditory signal detection task to induce auditory illusions by presenting speech snippets at near detection threshold intensity embedded in noise. We investigated the neural correlates of auditory false perceptions by examining the EEG activity preceding the responses in speech absent (false alarm, FA) trials and comparing them to speech present (hit) trials. The results of the comparison of event-related potentials (ERPs) in the activation period vs. baseline revealed the presence of an early negativity (EN) and a late positivity (LP) similar in both hits and FAs, which were absent in misses, correct rejections (CR) and control button presses (BPs). We postulate that the EN and the LP might represent the auditory awareness negativity (AAN) and centro-parietal positivity (CPP) or P300, respectively. The event-related spectral perturbations (ERSPs) exhibited a common power enhancement in low frequencies (<4 Hz) in hits and FAs. The low-frequency power enhancement has been frequently shown to be accompanied with P300 as well as separately being a marker of perceptual awareness, referred to as slow cortical potentials (SCP). Furthermore, the comparison of hits vs. FAs showed a significantly higher LP amplitude and low frequency power in hits compared to FAs. Generally, the observed patterns in the present results resembled some of the major neural correlates associated with perceptual awareness in previous studies. Our findings provide evidence that the neural correlates associated with conscious perception, can be elicited in similar ways in both presence and absence of externally presented sensory stimuli. The present findings did not reveal any pre-stimulus alpha and beta modulations distinguishing conscious vs. unconscious perceptions.

Scientific Reports · Mar 2021

On the use of envelope following responses to estimate peripheral level compression in the auditory system (opens in a new tab)

Gerard Encina-Llamas, Torsten Dau, Bastian Epp

Abstract

Individual estimates of cochlear compression may provide complementary information to traditional audiometric hearing thresholds in disentangling different types of peripheral cochlear damage. Here we investigated the use of the slope of envelope following response (EFR) magnitude-level functions obtained from four simultaneously presented amplitude modulated tones with modulation frequencies of 80–100 Hz as a proxy of peripheral level compression. Compression estimates in individual normal hearing (NH) listeners were consistent with previously reported group-averaged compression estimates based on psychoacoustical and distortion-product oto-acoustic emission (DPOAE) measures in human listeners. They were also similar to basilar membrane (BM) compression values measured invasively in non-human mammals. EFR-based compression estimates in hearing-impaired listeners were less compressive than those for the NH listeners, consistent with a reduction of BM compression. Cochlear compression was also estimated using DPOAEs in the same NH listeners. DPOAE estimates were larger (less compressive) than EFRs estimates, showing no correlation. Despite the numerical concordance between EFR-based compression estimates and group-averaged estimates from other methods, simulations using an auditory nerve (AN) model revealed that compression estimates based on EFRs might be highly influenced by contributions from off-characteristic frequency (CF) neural populations. This compromises the possibility to estimate on-CF (i.e., frequency-specific or “local”) peripheral level compression with EFRs.

eLife · Feb 2021

Exposing distinct subcortical components of the auditory brainstem response evoked by continuous naturalistic speech (opens in a new tab)

Melissa J Polonenko, Ross K Maddox

Abstract

Speech processing is built upon encoding by the auditory nerve and brainstem, yet we know very little about how these processes unfold in specific subcortical structures. These structures are deep and respond quickly, making them difficult to study during ongoing speech. Recent techniques have begun to address this problem, but yield temporally broad responses with consequently ambiguous neural origins. Here, we describe a method that pairs re-synthesized ‘peaky’ speech with deconvolution analysis of electroencephalography recordings. We show that in adults with normal hearing the method quickly yields robust responses whose component waves reflect activity from distinct subcortical structures spanning auditory nerve to rostral brainstem. We further demonstrate the versatility of peaky speech by simultaneously measuring bilateral and ear-specific responses across different frequency bands and discuss the important practical considerations such as talker choice. The peaky speech method holds promise as a tool for investigating speech encoding and processing, and for clinical applications.

Frontiers in Psychology · Jan 2021

Considerations in Audio-Visual Interaction Models: An ERP Study of Music Perception by Musicians and Non-musicians (opens in a new tab)

Marzieh Sorati, Dawn M. Behne

Abstract

Previous research with speech and non-speech stimuli suggested that in audiovisual perception, visual information starting prior to the onset of corresponding sound can provide visual cues, and form a prediction about the upcoming auditory sound. This prediction leads to audiovisual (AV) interaction. Auditory and visual perception interact and induce suppression and speeding up of the early auditory event-related potentials (ERPs) such as N1 and P2. To investigate AV interaction, previous research examined N1 and P2 amplitudes and latencies in response to audio only (AO), video only (VO), audiovisual, and control (CO) stimuli, and compared AV with auditory perception based on four AV interaction models (AV vs. AO+VO, AV-VO vs. AO, AV-VO vs. AO-CO, AV vs. AO). The current study addresses how different models of AV interaction express N1 and P2 suppression in music perception. Furthermore, the current study took one step further and examined whether previous musical experience, which can potentially lead to higher N1 and P2 amplitudes in auditory perception, influenced AV interaction in different models. Musicians and non-musicians were presented the recordings (AO, AV, VO) of a keyboard /C4/ key being played, as well as CO stimuli. Results showed that AV interaction models differ in their expression of N1 and P2 amplitude and latency suppression. The calculation of model (AV-VO vs. AO) and (AV-VO vs. AO-CO) has consequences for the resulting N1 and P2 difference waves. Furthermore, while musicians, compared to non-musicians, showed higher N1 amplitude in auditory perception, suppression of amplitudes and latencies for N1 and P2 was similar for the two groups across the AV models. Collectively, these results suggest that when visual cues from finger and hand movements predict the upcoming sound in AV music perception, suppression of early ERPs is similar for musicians and non-musicians. Notably, the calculation differences across models do not lead to the same pattern of results for N1 and P2, demonstrating that the four models are not interchangeable and are not directly comparable.

Trends in Hearing · 2021

Do Room Acoustics Affect the Amplitude of Sound-Field Auditory Steady-State Responses? (opens in a new tab)

Valentina Zapata-Rodriguez, Søren Laugesen, Cheol-Ho Jeong, … James Harte

Abstract

The sound-field auditory steady-state response (ASSR) is a promising measure for the objective validation of hearing-aid fitting in patients who are unable to respond to behavioral testing reliably. To record the sound-field ASSR, the stimulus is reproduced through a loudspeaker placed in front of the patient. However, the reverberation and background noise of the measurement room could reduce the stimulus modulation used for eliciting the ASSR. As the ASSR level is heavily dependent on the stimulus modulation, any reduction due to room acoustics could affect the clinical viability of sound-field ASSR testing. This study investigated the effect of room acoustics on the level and detection rate of sound-field ASSR. The study also analyzed whether early decay time and an auditory-inspired relative modulation power model could be used to predict the changes in the recorded ASSR in rooms. A monaural auralization approach was used to measure sound-field ASSR via insert earphones. ASSR was measured for 15 normal-hearing adult subjects using narrow-band CE-Chirps® centered at the octave bands of 500, 1000, 2000, and 4000 Hz. These stimuli were convolved with simulated impulse responses of three rooms inspired by audiological testing rooms. The results showed a significant reduction of the ASSR level for the room conditions compared with the reference anechoic condition. Despite this reduction, the detection rates for the first harmonics of the ASSR were unaffected when sufficiently long recordings (up to 6 min) were made. Furthermore, the early decay time and relative modulation power appear to be useful predictors of the ASSR level in the measurement rooms.

bioRxiv · Aug 2020

Cortical activity evoked by voice pitch changes: a combined fNIRS and EEG study (opens in a new tab)

Kurt Steinmetzger, Esther Megbel, Zhengzheng Shen, … André Rupp

Abstract

Numerous studies have investigated the cortical representation and time course of responses to auditory signals with and without pitch. However, little is known regarding the responses evoked by pitch changes. To study the spatial as well as temporal characteristics of cortical activity elicited by voice pitch changes, combined functional near-infrared spectroscopy (fNIRS) and electroencephalography (EEG) data were obtained from normal-hearing listeners presented with continuous vowel sequences in which the prosodic contours either varied between the individual vowels or were the same throughout. The fNIRS topographies and the EEG source reconstructions indicated additional right-hemispheric activity anterior to the primary auditory cortex and in the superior temporal sulcus for sequences with variable prosody. Additionally, the time courses of the fNIRS signals showed that activity was more sustained in response to sequences with changing prosodic contours. The EEG data revealed a similar pattern for the P2 amplitude, which was smaller during the second half for blocks with fixed prosody, whereas the P1 was consistently larger for sequences with variable prosody. Moreover, the sources of the P2, but not the P1, were lateralised to the right, suggesting that the hemispheric asymmetry in the processing of voice pitch changes develops over time.

Frontiers in Psychology · May 2020

Audiovisual Modulation in Music Perception for Musicians and Non-musicians (opens in a new tab)

Marzieh Sorati, Dawn Marie Behne

Abstract

In audiovisual music perception, visual information from a musical instrument being played is available prior to the onset of the corresponding musical sound and consequently allows a perceiver to form a prediction about the upcoming audio music. This prediction in audiovisual music perception, compared to auditory music perception, leads to lower N1 and P2 amplitudes and latencies. Although previous research suggests that audiovisual experience, such as previous musical experience may enhance this prediction, a remaining question is to what extent musical experience modifies N1 and P2 amplitudes and latencies. Furthermore, corresponding event-related phase modulations quantified as inter-trial phase coherence (ITPC) have not previously been reported for audiovisual music perception. In the current study, audio video recordings of a keyboard key being played were presented to musicians and non-musicians in audio only (AO), video only (VO), and audiovisual (AV) conditions. With predictive movements from playing the keyboard isolated from AV music perception (AV-VO), the current findings demonstrated that, compared to the AO condition, both groups had a similar decrease in N1 amplitude and latency, and P2 amplitude, along with correspondingly lower ITPC values in the delta, theta, and alpha frequency bands. However, while musicians showed lower ITPC values in the beta-band in AV-VO compared to the AO, non-musicians did not show this pattern. Findings indicate that AV perception may be broadly correlated with auditory perception, and differences between musicians and non-musicians further indicate musical experience to be a specific factor influencing AV perception. Predicting an upcoming sound in AV music perception may involve visual predictory processes, as well as beta-band oscillations, which may be influenced by years of musical training. This study highlights possible interconnectivity in AV perception as well as potential modulation with experience.

Journal of the Association for Research in Otolaryngology · Apr 2020

Noise-Induced Changes of the Auditory Brainstem Response to Speech-a Measure of Neural Desynchronisation? (opens in a new tab)

Jessica de Boer, Helen E. Nuttall, Katrin Krumbholz

Abstract

It is commonly assumed that difficulty in listening to speech in noise is at least partly due to deficits in neural temporal processing. Given that noise reduces the temporal fidelity of the auditory brainstem response (ABR) to speech, it has been suggested that the speech ABR may serve as an index of such neural deficits. However, the temporal fidelity of ABRs, to both speech and non-speech sounds, is also known to be influenced by the cochlear origin of the response, as responses from higher-frequency cochlear regions are faster and more synchronous than responses from lower-frequency regions. Thus, if noise caused a reweighting of response contributions from higher- to lower-frequency cochlear regions, the temporal fidelity of the aggregate response should be reduced even in the absence of any changes in neural processing. This ‘place mechanism’ has been demonstrated for non-speech ABRs. The aim of this study was to test whether it also applies to speech ABRs. We used the so-called ‘derived-band’ method to isolate response contributions from frequency-limited cochlear regions. Broadband and derived-band speech ABRs were measured both in quiet and in noise. Whilst the noise caused significant changes to the temporal properties of the broadband response, its effects on the derived-band responses were mostly restricted to the response amplitudes. Importantly, the amplitudes of the higher-frequency derived-band responses were much more strongly affected than those of the lower-frequency responses, suggesting that the noise indeed caused a reweighting effect. Our results indicate that, as for non-speech ABRs, the cochlear place mechanism can represent a potentially substantial confound to speech-ABR-in-noise measurements.

Frontiers in Psychology · Nov 2019

Musical Expertise Affects Audiovisual Speech Perception: Findings From Event-Related Potentials and Inter-trial Phase Coherence (opens in a new tab)

Marzieh Sorati, Dawn Marie Behne

Abstract

In audiovisual speech perception, visual information from a talker's face during mouth articulation is available before the onset of the corresponding audio speech, and thereby allows the perceiver to use visual information to predict the upcoming audio. This prediction from phonetically congruent visual information modulates audiovisual speech perception and leads to a decrease in N1 and P2 amplitudes and latencies compared to the perception of audio speech alone. Whether audiovisual experience, such as with musical training, influences this prediction is unclear, but if so, may explain some of the variations observed in previous research. The current study addresses whether audiovisual speech perception is affected by musical training, first assessing N1 and P2 event-related potentials (ERPs) and in addition, inter-trial phase coherence (ITPC). Musicians and non-musicians are presented the syllable, /ba/ in audio only (AO), video only (VO), and audiovisual (AV) conditions. With the predictory effect of mouth movement isolated from the AV speech (AV-VO), results showed that, compared to audio speech, both groups have a lower N1 latency and P2 amplitude and latency. Moreover, they also showed lower ITPCs in the delta, theta, and beta bands in audiovisual speech perception. However, musicians showed significant suppression of N1 amplitude and desynchronization in the alpha band in audiovisual speech, not present for non-musicians. Collectively, the current findings indicate that early sensory processing can be modified by musical experience, which in turn can explain some of the variations in previous AV speech perception research.

Frontiers in Neuroscience · Jul 2019

Acquisition of Subcortical Auditory Potentials With Around-the-Ear cEEGrid Technology in Normal and Hearing Impaired Listeners (opens in a new tab)

Markus Garrett, Stefan Debener, Sarah Verhulst

Abstract

Even though the principles of recording brain electrical activity remain unchanged since their discovery, their acquisition has seen major improvements. The cEEGrid, a recently developed flex-printed multi-channel sensory array, can be placed around the ear and successfully record well-known cortical electrophysiological potentials such as late auditory evoked potentials (AEPs) or the P300. Due to its fast and easy application as well as its long-lasting signal recording window, the cEEGrid technology offers great potential as a flexible and 'wearable' solution for the acquisition of neural correlates of hearing. Early potentials of auditory processing such as the auditory brainstem response (ABR) are already used in clinical assessment of sensorineural hearing disorders and envelope following responses (EFR) have shown promising results in the diagnosis of suprathreshold hearing deficits. This study evaluates the suitability of the cEEGrid electrode configuration to capture these AEPs. cEEGrid potentials were recorded and compared to cap-EEG potentials for young normal-hearing listeners and older listeners with high-frequency sloping audiograms to assess whether the recordings are adequately sensitive for hearing diagnostics. ABRs were elicited by presenting clicks (70 and 100-dB peSPL) and stimulation for the EFRs consisted of 120 Hz amplitude-modulated white noise carriers presented at 70-dB SPL. Data from nine bipolar cEEGrid channels and one classical cap-EEG montage (earlobes to vertex) were analysed and outcome measures were compared. Results show that the cEEGrid is able to record ABRs and EFRs with comparable shape to those recorded using a conventional cap-EEG recording montage and the same amplifier. Signal strength is lower but can still produce responses above the individual neural electrophysiological noise floor. This study shows that the application of the cEEGrid can be extended to the acquisition of early auditory evoked potentials.

Ear & Hearing · May 2019

Speech Auditory Brainstem Responses: Effects of Background, Stimulus Duration, Consonant-Vowel, and Number of Epochs (opens in a new tab)

Ghada BinKhamis, Agnès Léger, Steven L. Bell, … Karolina Kluk

Abstract

Objectives: The aims of this study were to systematically explore the effects of stimulus duration, background (quiet versus noise), and three consonant–vowels on speech-auditory brainstem responses (ABRs). Additionally, the minimum number of epochs required to record speech-ABRs with clearly identifiable waveform components was assessed. The purpose was to evaluate whether shorter duration stimuli could be reliably used to record speech-ABRs both in quiet and in background noise to the three consonant–vowels, as opposed to longer duration stimuli that are commonly used in the literature. Shorter duration stimuli and a smaller number of epochs would require shorter test sessions and thus encourage the transition of the speech-ABR from research to clinical practice. Design: Speech-ABRs in response to 40 msec [da], 50 msec [ba] [da] [ga], and 170 msec [ba] [da] [ga] stimuli were collected from 12 normal-hearing adults with confirmed normal click-ABRs. Monaural (right-ear) speech-ABRs were recorded to all stimuli in quiet and to 40 msec [da], 50 msec [ba] [da] [ga], and 170 msec [da] in a background of two-talker babble at +10 dB signal to noise ratio using a 2-channel electrode montage (Cz-Active, A1 and A2-reference, Fz-ground). Twelve thousand epochs (6000 per polarity) were collected for each stimulus and background from all participants. Latencies and amplitudes of speech-ABR peaks (V, A, D, E, F, O) were compared across backgrounds (quiet and noise) for all stimulus durations, across stimulus durations (50 and 170 msec) and across consonant–vowels ([ba], [da], and [ga]). Additionally, degree of phase locking to the stimulus fundamental frequency (in quiet versus noise) was evaluated for the frequency following response in speech-ABRs to the 170 msec [da]. Finally, the number of epochs required for a robust response was evaluated using F sp statistic and bootstrap analysis at different epoch iterations. Results: Background effect: the addition of background noise resulted in speech-ABRs with longer peak latencies and smaller peak amplitudes compared with speech-ABRs in quiet, irrespective of stimulus duration. However, there was no effect of background noise on the degree of phase locking of the frequency following response to the stimulus fundamental frequency in speech-ABRs to the 170 msec [da]. Duration effect: speech-ABR peak latencies and amplitudes did not differ in response to the 50 and 170 msec stimuli. Consonant–vowel effect: different consonant–vowels did not have an effect on speech-ABR peak latencies regardless of stimulus duration. Number of epochs: a larger number of epochs was required to record speech-ABRs in noise compared with in quiet, and a smaller number of epochs was required to record speech-ABRs to the 40 msec [da] compared with the 170 msec [da]. Conclusions: This is the first study that systematically investigated the clinical feasibility of speech-ABRs in terms of stimulus duration, background noise, and number of epochs. Speech-ABRs can be reliably recorded to the 40 msec [da] without compromising response quality even when presented in background noise. Because fewer epochs were needed for the 40 msec [da], this would be the optimal stimulus for clinical use. Finally, given that there was no effect of consonant–vowel on speech-ABR peak latencies, there is no evidence that speech-ABRs are suitable for assessing auditory discrimination of the stimuli used.

Hearing Research · Mar 2019

Gap-induced inhibition of the post-auricular muscle response in humans and guinea pigs (opens in a new tab)

Caroline A. Wilson, Joel I. Berger, Jessica de Boer, … Mark N. Wallace

Abstract

A common method for measuring changes in temporal processing sensitivity in both humans and animals makes use of GaP-induced Inhibition of the Acoustic Startle (GPIAS). It is also the basis of a common method for detecting tinnitus in rodents. However, the link to tinnitus has not been properly established because GPIAS has not yet been used to objectively demonstrate tinnitus in humans. In guinea pigs, the Preyer (ear flick) myogenic reflex is an established method for measuring the acoustic startle for the GPIAS test, while in humans, it is the eye-blink reflex. Yet, humans have a vestigial remnant of the Preyer reflex, which can be detected by measuring skin surface potentials associated with the Post-Auricular Muscle Response (PAMR). A similar electrical potential can be measured in guinea pigs and we aimed to show that the PAMR could be used to demonstrate GPIAS in both species. In guinea pigs, we compare the GPIAS measured using the pinna movement of the Preyer reflex and the electrical potential of the PAMR to demonstrate that the two are at least equivalent. In humans, we establish for the first time that the PAMR provides a reliable way of measuring GPIAS that is a pure acoustic alternative to the multimodal eye-blink reflex. Further exploratory tests showed that while eye gaze position influenced the size of the PAMR response, it did not change the degree of GPIAS. Our findings confirm that the PAMR is a sensitive method for measuring GPIAS and suggest that it may allow direct comparison of temporal processing between humans and animals and may provide a basis for an objective test of tinnitus.

Frontiers in Systems Neuroscience · Feb 2019

Sensitivity to Vocalization Pitch in the Caudal Auditory Cortex of the Marmoset: Comparison of Core and Belt Areas (opens in a new tab)

Shuyu Zhu, Benjamin Allitt, Anil Samuel, … Ramesh Rajan

Abstract

Based on anatomical connectivity and basic response characteristics, primate auditory cortex is divided into a central core surrounded by belt and parabelt regions. The encoding of pitch, a prototypical element of sound identity, has been studied in primary auditory cortex (A1) but little is known about how it is encoded and represented beyond A1. The caudal auditory belt and parabelt cortical fields process spatial information but also contain information on non-spatial aspects of sounds. In this study, we examined neuronal responses in these areas to pitch-varied marmoset vocalizations, to derive the consequent representation of pitch in these regions and the potential underlying mechanisms, to compare to the encoding and representation of pitch of the same sounds in A1. With respect to response patterns to the vocalizations, neurons in caudal medial belt (CM) showed similar short-latency and short-duration response patterns to A1, but caudal lateral belt (CL) neurons at the same hierarchical level and caudal parabelt (CPB) neurons at a higher hierarchical level showed delayed or much delayed response onset and prolonged response durations. With respect to encoding of pitch, neurons in all cortical fields showed sensitivity to variations in the vocalization pitch either through modulation of spike-count or of first spike-latency. The utility of the encoding mechanism differed between fields: pitch sensitivity was reliably represented by spike-count variations in A1 and CM, while first spike-latency variation was better for encoding pitch in CL and CPB. In summary, our data show that (a) the traditionally-defined belt area CM is functionally very similar to A1 with respect to the representation and encoding of complex naturalistic sounds, (b) the CL belt area, at the same hierarchical level as CM, and the CPB area, at a higher hierarchical level, have very different response patterns and appear to use different pitch-encoding mechanisms, and (c) caudal auditory fields, proposed to be specialized for encoding spatial location, can also contain robust representations of sound identity.

Trends in Hearing · 2019

The Parallel Auditory Brainstem Response (opens in a new tab)

Melissa J. Polonenko, Ross K. Maddox

Abstract

The frequency-specific tone-evoked auditory brainstem response (ABR) is an indispensable tool in both the audiology clinic and research laboratory. Most frequently, the toneburst ABR is used to estimate hearing thresholds in infants, toddlers, and other patients for whom behavioral testing is not feasible. Therefore, results of the ABR exam form the basis for decisions regarding interventions and hearing habilitation with implications extending far into the child’s future. Currently, responses are elicited by periodic sequences of toneburst stimuli presented serially to one ear at a time, which take a long time to measure multiple frequencies and intensities, and provide incomplete information if the infant wakes up early. Here, we describe a new method, the parallel ABR (pABR), which uses randomly timed toneburst stimuli to simultaneously acquire ABR waveforms to five frequencies in both ears. Here, we describe the pABR and quantify its effectiveness in addressing the greatest drawback of current methods: test duration. We show that in adults with normal hearing the pABR yields high-quality waveforms over a range of intensities, with similar morphology to the standard ABR in a fraction of the recording time. Furthermore, longer latencies and smaller amplitudes for low frequencies at a high intensity evoked by the pABR versus serial ABR suggest that responses may have better place specificity due to the masking provided by the other simultaneous toneburst sequences. Thus, the pABR has substantial potential for facilitating faster accumulation of more diagnostic information that is important for timely identification and treatment of hearing loss.

Trends in Hearing · 2019

Speech Auditory Brainstem Responses in Adult Hearing Aid Users: Effects of Aiding and Background Noise, and Prediction of Behavioral Measures (opens in a new tab)

Ghada BinKhamis, Antonio Elia Forte, Tobias Reichenbach, … Karolina Kluk

Abstract

Evaluation of patients who are unable to provide behavioral responses on standard clinical measures is challenging due to the lack of standard objective (non-behavioral) clinical audiological measures that assess the outcome of an intervention (e.g., hearing aids). Brainstem responses to short consonant-vowel stimuli (speech-auditory brainstem responses [speech-ABRs]) have been proposed as a measure of subcortical encoding of speech, speech detection, and speech-in-noise performance in individuals with normal hearing. Here, we investigated the potential application of speech-ABRs as an objective clinical outcome measure of speech detection, speech-in-noise detection and recognition, and self-reported speech understanding in 98 adults with sensorineural hearing loss. We compared aided and unaided speech-ABRs, and speech-ABRs in quiet and in noise. In addition, we evaluated whether speech-ABR F0 encoding (obtained from the complex cross-correlation with the 40 ms [da] fundamental waveform) predicted aided behavioral speech recognition in noise or aided self-reported speech understanding. Results showed that (a) aided speech-ABRs had earlier peak latencies, larger peak amplitudes, and larger F0 encoding amplitudes compared to unaided speech-ABRs; (b) the addition of background noise resulted in later F0 encoding latencies but did not have an effect on peak latencies and amplitudes or on F0 encoding amplitudes; and (c) speech-ABRs were not a significant predictor of any of the behavioral or self-report measures. These results show that speech-ABR F0 encoding is not a good predictor of speech-in-noise recognition or self-reported speech understanding with hearing aids. However, our results suggest that speech-ABRs may have potential for clinical application as an objective measure of speech detection with hearing aids.

American journal of translational research · 2019

Cisplatin induces calcium ion accumulation and hearing loss by causing functional alterations in calcium channels and exocytosis (opens in a new tab)

Lu J, Wang W, Liu H

Abstract

In recent years, molecular biology and biochemistry have been a focus of studies on the ototoxic side effects of cisplatin. In this paper, the application of cisplatin for 4 h and 72 h was studied from the perspective of electrophysiological function. Patch clamp experiments and immunofluorescence staining were performed on inner hair cells of the cochlea. The patch-clamp results showed that the calcium current amplitude decreased significantly at 4 h and 72 h after cisplatin treatment, the reversal potential was negatively polarized, and the activation time decreased. We suspected that intracellular calcium accumulation was responsible for this result and confirmed this hypothesis by using calpain to measure intracellular calcium concentrations. We tested membrane capacitive function, whose levels after cisplatin application were significantly lower than those in the control group, thus indicating dysfunctional cytoplasmic effervescent function. CtBP2 staining was used to verify this result and indicated a decrease in ribbon synapses. Simultaneously, we observed dysfunction of vesicle circulation after cisplatin application. We found that cisplatin induces the accumulation of calcium ions in inner hair cells by calpain staining and fluoresce intensity calculation, thus decreasing calcium current and synaptic vesicle release, and impairing vesicles cycling, all of which are important mechanisms of cisplatin-induced hearing loss.

PLOS Biology · Oct 2018

High-resolution frequency tuning but not temporal coding in the human cochlea (opens in a new tab)

Eric Verschooten, Christian Desloovere, Philip X. Joris

Abstract

Frequency tuning and phase-locking are two fundamental properties generated in the cochlea, enabling but also limiting the coding of sounds by the auditory nerve (AN). In humans, these limits are unknown, but high resolution has been postulated for both properties. Electrophysiological recordings from the AN of normal-hearing volunteers indicate that human frequency tuning, but not phase-locking, exceeds the resolution observed in animal models.

eneuro · Sep 2018

Gas Anesthesia Impairs Peripheral Auditory Sensitivity in Barn Owls ( Tyto alba ) (opens in a new tab)

Nadine Thiele, Christine Köppl

Abstract

Auditory nerve single-unit recordings were obtained from two groups of young barn owls (age, between posthatching days 11 and 86) in terminal experiments under two different anesthetic regimes: ketamine (6-11 mg/kg) plus xylazine (∼2 mg/kg); or isoflurane (1-1.5%) in oxygen, delivered via artificial respiration. In a second series of minimally invasive experiments, auditory brainstem responses (ABRs) were recorded in the same four adult barn owls (Tyto alba; age, between 5 and 32 months) under three different anesthetic protocols: ketamine (10 mg/kg) plus xylazine (3 mg/kg), isoflurane (1-1.5%), and sevoflurane (2-3%) in carbogen. Finally, the ABR measurements on adult owls were repeated in terminal experiments including more invasive procedures such as artificial respiration and higher isoflurane dosage. The main finding was a significant deterioration of auditory sensitivity in barn owls under gas anesthesia, at the level of the auditory nerve (i.e., a very peripheral level of the auditory system). The effect was drastic in the young animals that experienced threshold elevations in auditory nerve single-unit responses of ≥20 dB. ABR thresholds assessed repeatedly in experiments on adult owls were also significantly higher under isoflurane and sevoflurane, on average by 7 and 15 dB, compared with ketamine/xylazine. This difference already occurred with minimal dosages and was reversibly enlarged with increased isoflurane concentration. Finally, there was evidence for confounding detrimental effects associated with artificial respiration over many hours, which suggested oxygen toxicity.

eneuro · 2018

Auditory Brainstem Responses to Continuous Natural Speech in Human Listeners (opens in a new tab)

Ross K. Maddox, Adrian K. C. Lee

Abstract

Speech is an ecologically essential signal, whose processing crucially involves the subcortical nuclei of the auditory brainstem, but there are few experimental options for studying these early responses in human listeners under natural conditions. While encoding of continuous natural speech has been successfully probed in the cortex with neurophysiological tools such as electroencephalography (EEG) and magnetoencephalography, the rapidity of subcortical response components combined with unfavorable signal-to-noise ratios signal-to-noise ratio has prevented application of those methods to the brainstem. Instead, experiments have used thousands of repetitions of simple stimuli such as clicks, tone-bursts, or brief spoken syllables, with deviations from those paradigms leading to ambiguity in the neural origins of measured responses. In this study we developed and tested a new way to measure the auditory brainstem response (ABR) to ongoing, naturally uttered speech, using EEG to record from human listeners. We found a high degree of morphological similarity between the speech-derived ABRs and the standard click-evoked ABR, in particular, a preserved Wave V, the most prominent voltage peak in the standard click-evoked ABR. Because this method yields distinct peaks that recapitulate the canonical ABR, at latencies too short to originate from the cortex, the responses measured can be unambiguously determined to be subcortical in origin. The use of naturally uttered speech to measure the ABR allows the design of engaging behavioral tasks, facilitating new investigations of the potential effects of cognitive processes like language and attention on brainstem processing.

bioRxiv · Dec 2017

Transcranial alternating current stimulation modulates auditory temporal resolution in elderly people (opens in a new tab)

Alina Baltus, Christoph Siegfried Herrmann

Abstract

Recent research provides evidence for a functional role of brain oscillations for perception. For example, auditory temporal resolution seems to be linked to individual gamma frequency of auditory cortex. Individual gamma frequency not only correlates with performance in between-channel gap detection tasks but can be modulated via auditory transcranial alternating current stimulation. Modulation of individual gamma frequency is accompanied by an improvement in gap detection performance. Aging changes electrophysiological frequency components and sensory processing mechanisms. Therefore, we conducted a study to investigate the link between individual gamma frequency and gap detection performance in elderly people using auditory transcranial alternating current stimulation. In a within-subject design, nine participants were electrically stimulated with two individualized transcranial alternating current stimulation frequencies: 3 Hz above their individual gamma frequency (experimental condition) and 4 Hz below their individual gamma frequency (control condition) while they were performing a between-channel gap detection task. As expected, individual gamma frequencies correlated significantly with gap detection performance at baseline and in the experimental condition, transcranial alternating current stimulation modulated gap detection performance. In the control condition, stimulation did not modulate gap detection performance. In addition, in elderly, the effect of transcranial alternating current stimulation on auditory temporal resolution seems to be dependent on endogenous frequencies in auditory cortex: elderlies with slower individual gamma frequencies and lower auditory temporal resolution profit from auditory transcranial alternating current stimulation and show increased gap detection performance during stimulation. Our results strongly suggest individualized transcranial alternating current stimulation protocols for successful modulation of performance.