British Journal of Audiology · Dec 2001
Moore BC, Glasberg BR, Alcántara JI, … Kuehnel V
Abstract
The inherent amplitude fluctuations in narrow bands of noise may limit the ability to detect gaps in the noise; 'dips' in the noise may be confused with the gap to be detected. For people with cochlear hearing loss, loudness recruitment may effectively magnify the fluctuations and this could partly account for the reduced ability to detect gaps in noise bands that is usually found for such people. Previously, we tested these ideas by processing the envelopes of noise bands to alter the amount of envelope fluctuation. We showed that instantaneous compression, implemented via processing of the Hilbert envelope, led to smaller (that is, better) gap detection thresholds for subjects with cochlear hearing loss. In the present experiment, we determined whether fast-acting compression of the type sometimes used in hearing aids could also lead to improved gap detection. A behind-the-ear (BTE) digital hearing aid was programmed to implement multi-band compression, either fast-acting or slow-acting (control condition). A reference condition using unaided listening was also used. Stimuli were delivered via an earphone placed over the hearing aid. Overall stimulus levels at the output of the hearing aid were similar across conditions. Thresholds for detecting gaps in noise bands centred at 4 kHz were measured as a function of noise bandwidth (10-500 Hz). To prevent the detection of spectral changes introduced by the gap, stimuli were presented in a broad-band background noise. Three normally hearing subjects and three subjects with bilateral cochlear hearing loss were tested. Gap thresholds varied non-monotonically with noise bandwidth, being maximal around 50 Hz. Gap thresholds were generally higher for the hearing-impaired than for the normally hearing subjects. For the latter, gap thresholds were similar for the three conditions. For the hearing-impaired subjects, gap thresholds were similar for the unaided condition and the condition using slow compression. However, fast compression led to smaller gap thresholds, especially for noise bandwidths up to 50 Hz. The results show that fast compression can improve the ability of hearing-impaired subjects to detect gaps in sounds with slowly fluctuating envelopes.
Journal of Experimental Biology · Nov 2001
Ridgway SH, Carder DA, Kamolnick T, … Elsberry WR
Abstract
Hearing is attenuated in the aerial ear of humans and other land mammals tested in pressure chambers as a result of middle ear impedance changes that result from increased air density. We tested the hypothesis, based on recent middle ear models, that increasing the density of middle ear air at depth might attenuate whale hearing. Two white whales Delphinapterus leucas made dives to a platform at a depth of 5, 100, 200 or 300 m in the Pacific Ocean. During dives to station on the platform for up to 12 min, the whales whistled in response to 500 ms tones projected at random intervals to assess their hearing threshold at each depth. Analysis of response whistle spectra, whistle latency in response to tones and hearing thresholds showed that the increased hydrostatic pressure at depth changed each whale's whistle response at depth, but did not attenuate hearing overall. The finding that whale hearing is not attenuated at depth suggests that sound is conducted through the head tissues of the whale to the ear without requiring the usual ear drum/ossicular chain amplification of the aerial middle ear. These first ever hearing tests in the open ocean demonstrate that zones of audibility for human-made sounds are just as great throughout the depths to which these whales dive, or at least down to 300 m.
The Journal of the Acoustical Society of America · Nov 2001
Drennan WR, Watson CS
Abstract
This study investigated two sources of variance in the ability to discriminate auditory profiles: individual differences and extended training. The goals of the study were (1) to determine the range and origins of individual differences in profile analysis and (2) to determine whether those who initially had poor sensitivity to changes in spectral shape could eventually acquire finer sensitivity. Profile stimuli had 11 components with equal-log spacing from 200-2200 Hz. Thresholds ranged from - 1 to -25 dB (signal level relative to the context level) across 46 listeners. The correlation between spectral-shape discrimination thresholds after 2000 trials and pure-tone intensity-discrimination thresholds was 0.36. The range of individual differences for pure-tone intensity discrimination and spectral-shape discrimination was about the same. Two groups of listeners were given extended practice on the profile task, one group that showed low thresholds after an initial 2000 trials of practice and another that showed much higher initial thresholds. All listeners improved during the course of the first 2000 trials of training. Most of the poor listeners continued to improve during 9000 trials of training. Individual differences in the listeners' sensitivity to changes in spectral shape still existed after the extended practice.
Proceedings of the National Academy of Sciences of the United States of America · Oct 2001
Alain C, Arnott SR, Hevenor S, et al.
Abstract
The extent to which sound identification and sound localization depend on specialized auditory pathways was examined by using functional magnetic resonance imaging and event-related brain potentials. Participants performed an S1-S2 match-to-sample task in which S1 differed from S2 in its pitch and/or location. In the pitch task, participants indicated whether S2 was lower, identical, or higher in pitch than S1. In the location task, participants were asked to localize S2 relative to S1 (i.e., leftward, same, or rightward). Relative to location, pitch processing generated greater activation in auditory cortex and the inferior frontal gyrus. Conversely, identifying the location of S2 relative to S1 generated greater activation in posterior temporal cortex, parietal cortex, and the superior frontal sulcus. Differential task-related effects on event-related brain potentials (ERPs) were seen in anterior and posterior brain regions beginning at 300 ms poststimulus and lasting for several hundred milliseconds. The converging evidence from two independent measurements of dissociable brain activity during identification and localization of identical stimuli provides strong support for specialized auditory streams in the human brain. These findings are analogous to the "what" and "where" segregation of visual information processing, and suggest that a similar functional organization exists for processing information from the auditory modality.
The Journal of the Acoustical Society of America · Oct 2001
Sinnott JM, Mosteller KW
Abstract
The Mongolian gerbil is a small rodent with human-like absolute auditory sensitivity in the speech range below 4 kHz. Here, gerbil “speech DLs” (difference limens) are measured along several synthetic speech continua and compared with human data. Results show that gerbils are similar to humans in that they discriminate “within-category” information more easily for vowels than for consonants. However, gerbils are less sensitive to all the speech stimuli, with DLs about 2–3 times higher. Interestingly, gerbil speech DLs are not accurately predicted by their pure-tone frequency DL, which is 36 times that of the human at 1 kHz. Thus, gerbils are actually much more similar to humans in speech sound discrimination than in pure-tone discrimination. It is concluded that the gerbil offers a promising “small-mammal” model for the processing of spectral cues in human speech sounds.
The Journal of the Acoustical Society of America · Oct 2001
Moss CF, Surlykke A
Abstract
Echolocating bats transmit ultrasonic vocalizations and use information contained in the reflected sounds to analyze the auditory scene. Auditory scene analysis, a phenomenon that applies broadly to all hearing vertebrates, involves the grouping and segregation of sounds to perceptually organize information about auditory objects. The perceptual organization of sound is influenced by the spectral and temporal characteristics of acoustic signals. In the case of the echolocating bat, its active control over the timing, duration, intensity, and bandwidth of sonar transmissions directly impacts its perception of the auditory objects that comprise the scene. Here, data are presented from perceptual experiments, laboratory insect capture studies, and field recordings of sonar behavior of different bat species, to illustrate principles of importance to auditory scene analysis by echolocation in bats. In the perceptual experiments, FM bats (Eptesicus fuscus) learned to discriminate between systematic and random delay sequences in echo playback sets. The results of these experiments demonstrate that the FM bat can assemble information about echo delay changes over time, a requirement for the analysis of a dynamic auditory scene. Laboratory insect capture experiments examined the vocal production patterns of flying E. fuscus taking tethered insects in a large room. In each trial, the bats consistently produced echolocation signal groups with a relatively stable repetition rate (within 5%). Similar temporal patterning of sonar vocalizations was also observed in the field recordings from E. fuscus, thus suggesting the importance of temporal control of vocal production for perceptually guided behavior. It is hypothesized that a stable sonar signal production rate facilitates the perceptual organization of echoes arriving from objects at different directions and distances as the bat flies through a dynamic auditory scene. Field recordings of E. fuscus, Noctilio albiventris, N. leporinus, Pippistrellus pippistrellus, and Cormura brevirostris revealed that spectral adjustments in sonar signals may also be important to permit tracking of echoes in a complex auditory scene.
The Journal of the Acoustical Society of America · Oct 2001
Nelson DA, Schroder AC, Wojtczak M
Abstract
Forward-masking growth functions for on-frequency (6-kHz) and off-frequency (3-kHz) sinusoidal maskers were measured in quiet and in a high-pass noise just above the 6-kHz probe frequency. The data show that estimates of response-growth rates obtained from those functions in quiet, which have been used to infer cochlear compression, are strongly dependent on the spread of probe excitation toward higher frequency regions. Therefore, an alternative procedure for measuring response-growth rates was proposed, one that employs a fixed low-level probe and avoids level-dependent spread of probe excitation. Fixed-probe-level temporal masking curves (TMCs) were obtained from normal-hearing listeners at a test frequency of 1 kHz, where the short 1-kHz probe was fixed in level at about 10 dB SL. The level of the preceding forward masker was adjusted to obtain masked threshold as a function of the time delay between masker and probe. The TMCs were obtained for an on-frequency masker (1 kHz) and for other maskers with frequencies both below and above the probe frequency. From these measurements, input/output response-growth curves were derived for individual ears. Response-growth slopes varied from >1.0 at low masker levels to 80 dB SPL). For the fixed-level probe, the TMC slopes changed very little in the presence of a high-pass noise masking upward spread of probe excitation. A greater effect on the TMCs was observed when a high-frequency cueing tone was used with the masking tone. In both cases, however, the net effects on the estimated rate of response growth were minimal.
Hearing Research · Sep 2001
Baer T, Moore BC, Marriage J
Abstract
For normal listeners, difference limens for intensity (DLs) for Gaussian-shaped tone pulses are largest at medium pulse durations (corresponding to about five cycles of the tonal carrier) when the pedestals are 10 dB above threshold, either in quiet or in a pink noise background. One explanation for this is that worst performance occurs when the internal representation of the tone pulses is most compact in time and frequency, affording minimal opportunity for 'multiple looks' (Van Schijndel et al., J. Acoust. Soc. Am. 105 (1999) 3425-3435). However, the mid-duration worsening is largest for medium overall levels, suggesting an involvement of compression on the basilar membrane (BM), which is also greatest at medium levels (Baer et al., J. Acoust. Soc. Am. 106 (1999) 1907-1916). If this is so, the mid-duration worsening should be reduced when BM compression is reduced by outer hair cell damage. To test this, subjects with sensorineural hearing losses were tested using 1-kHz or 4-kHz Gaussian-shaped tone pulses, in quiet or in pink noise that raised thresholds by 10-20 dB. For subjects with mild losses, poorest performance was sometimes found for medium durations. For more severe losses, intensity DLs tended to improve monotonically or remain roughly constant with increasing duration. Performance overall tended to be better for subjects with greater hearing losses. The results are more consistent with an explanation based on BM compression than with an explanation based on multiple looks.
Trends in Amplification · Sep 2001
Gregory A. Flamme
Abstract
In an unaided context, and in spite of obvious conceptual differences, direction and distance hearing, soft sounds hearing, and speech understanding in noise hearing are so strongly interrelated that accurate measures of a listener's particular abilities on one of these traits would be difficult to obtain, given prior knowledge of performance on at least one of the others. The tests that are commonly used to estimate a listener's hearing performance do not provide sufficiently accurate and unbiased information. Most auditory tests are heavily influenced by method-related factors that are not impacted by the trait expected to be measured by the test. Method-related variance in test scores is not related to the trait of interest, but might still provide useful information about the person being tested. If a tester must use a set of tests with small amounts of trait variance, he/she can obtain better estimates of a person's performance on the trait by: including tests that use very different measurement methods (e.g., psychophysical, self-report, and significant-other report) converting the scores from these tests into the same metric (e.g., standardized scores) and combining the scores into an overall score. Although this is informally done in most clinical situations, formal procedures and norms should be developed. In clinical trials, outcome measures with large amounts of method variance are less likely to identify treatment options that are indeed beneficial. Method variance is systematic (i.e., an individual's bias associated with a measurement method can be expected to be stable over time and consistently different from people with other method biases. Because of this, the method variance component of a person's test score cannot be expected to average out over repeated samples, nor can it be expected to be changed by a treatment designed to change performance on a trait. Observable differences between treatments are reduced by method variance in outcome measures. Acknowledgments The author thanks Robyn Cox and Will Shadish for their consultation and assistance with this project, and Ruth Bentler, Martyn Hyde, and an anonymous reviewer for their helpful comments on an earlier version of this manuscript. Chris Bentler and Jason Ruyle also deserve recognition for their help entering the simulation study data.
The Journal of the Acoustical Society of America · Aug 2001
Shinn-Cunningham BG, Schickler J, Kopco N, et al.
Abstract
Spatial unmasking of speech has traditionally been studied with target and masker at the same, relatively large distance. The present study investigated spatial unmasking for configurations in which the simulated sources varied in azimuth and could be either near or far from the head. Target sentences and speech-shaped noise maskers were simulated over headphones using head-related transfer functions derived from a spherical-head model. Speech reception thresholds were measured adaptively, varying target level while keeping the masker level constant at the "better" ear. Results demonstrate that small positional changes can result in very large changes in speech intelligibility when sources are near the listener as a result of large changes in the overall level of the stimuli reaching the ears. In addition, the difference in the target-to-masker ratios at the two ears can be substantially larger for nearby sources than for relatively distant sources. Predictions from an existing model of binaural speech intelligibility are in good agreement with results from all conditions comparable to those that have been tested previously. However, small but important deviations between the measured and predicted results are observed for other spatial configurations, suggesting that current theories do not accurately account for speech intelligibility for some of the novel spatial configurations tested.
Ear & Hearing · Aug 2001
Moore BC, Alcántara JI
Abstract
Objective "Dead regions" are regions in the cochlea with no functioning inner hair cells (IHCs) and/or neurons. Amplification (using a hearing aid) over a frequency range corresponding to a dead region may not be beneficial and may even impair speech intelligibility. The objective of this article is to illustrate the use of psychophysical tuning curves (PTCs) as a tool for investigating dead regions and to illustrate the variety of audiogram configurations that can be associated with dead regions. We explore the influence of signal level and signal frequency to test the hypothesis that the frequency at the tip of the tuning curve defines the boundary of the dead region. Design PTCs were measured for five subjects with sensorineural hearing loss who were suspected of having dead regions. One had a relatively "flat" loss, one had a mild mid-frequency loss and three had high-frequency losses, varying in severity from 70 dB to more than 120 dB. For each PTC, the level and frequency of the sinusoidal signal were fixed, and the level of a narrowband noise masker needed just to mask the signal was determined as a function of the masker frequency. When the signal falls in a frequency region that is not "dead," the signal is detected via IHCs with characteristic frequencies (CFs) at or close to the signal frequency. In such a case, the tip of the PTC (the masker frequency at which the masker level is lowest) lies at or close to the signal frequency. When a dead region is present, the signal is detected via IHCs with CFs different from that of the signal frequency. In such a case, the tip of the PTC is shifted away from the signal frequency. Results PTCs with frequency-shifted tips (indicative of dead regions) were found for all subjects. The frequencies at the tips sometimes decreased slightly with increasing signal level. For the subject with a relatively flat loss, PTCs with tips close to 3000 Hz were obtained for signal frequencies of 400, 1000 and 1500 Hz. A PTC with a tip at 5000 Hz was found for a signal frequency of 6000 Hz. These results suggest that this subject had an "island" of surviving IHCs and neurons with CFs ranging from 3000 to 5000 Hz, with extensive dead regions on either side. For the subject with a mid-frequency loss, the pattern of results suggested a mid-frequency dead region. For the subjects with high-frequency loss, the results suggested the presence of high-frequency dead regions, in one case starting at a frequency where absolute thresholds were only slightly higher than normal. Conclusions PTCs can be used to detect and delimit dead regions. Often, the frequency at the tip of the PTC can be used to define approximately one boundary of the dead region. However, the detection of beats can affect the shape of the PTC around the tip when the signal frequency lies just inside the dead region. The level of the signal can also have some effect on the frequency at the tip of the PTC. Very low signal levels can lead to variable results. Dead regions can start at frequencies where absolute thresholds are near normal.
The Journal of the Acoustical Society of America · Aug 2001
Moore BC, Glasberg BR
Abstract
Temporal modulation transfer functions were obtained using sinusoidal carriers for four normally hearing subjects and three subjects with mild to moderate cochlear hearing loss. Carrier frequencies were 1000, 2000 and 5000 Hz, and modulation frequencies ranged from 10 to 640 Hz in one-octave steps. The normally hearing subjects were tested using levels of 30 and 80 dB SPL. For the higher level, modulation detection thresholds varied only slightly with modulation frequency for frequencies up to 80 Hz, but decreased for high modulation frequencies. The decrease can be attributed to the detection of spectral sidebands. For the lower level, thresholds varied little with modulation frequency for all three carrier frequencies. The absence of a decrease in the threshold for large modulation frequencies can be explained by the low sensation level of the spectral sidebands. The hearing-impaired subjects were tested at 80 dB SPL, except for two cases where the absolute threshold at the carrier frequency was greater than 70 dB SPL; in these cases a level of 90 dB was used. The results were consistent with the idea that spectral sidebands were less detectable for the hearing-impaired than for the normally hearing subjects. For the two lower carrier frequencies, there were no large decreases in threshold with increasing modulation frequency, and where decreases did occur, this happened only between 320 and 640 Hz. For the 5000-Hz carrier, thresholds were roughly constant for modulation frequencies from 10 to 80 or 160 Hz, and then increased monotonically, becoming unmeasurable at 640 Hz. The results for this carrier may reflect "pure" effects of temporal resolution, without any influence from the detection of spectral sidebands. The results suggest that temporal resolution for deterministic stimuli is similar for normally hearing and hearing-impaired listeners.
The Journal of the Acoustical Society of America · Aug 2001
Vickers DA, Moore BC, Baer T
Abstract
A dead region is a region of the cochlea where there are no functioning inner hair cells (IHCs) and/or neurons; it can be characterized in terms of the characteristic frequencies of the IHCs bordering that region. We examined the effect of high-frequency amplification on speech perception for subjects with high-frequency hearing loss with and without dead regions. The limits of any dead regions were defined by measuring psychophysical tuning curves and were confirmed using the TEN test described in Moore et al. [Br. J. Audiol. 34, 205-224 (2000)]. The speech stimuli were vowel-consonant-vowel (VCV) nonsense syllables, using one of three vowels (/i/, /a/, and /u/) and 21 different consonants. In a baseline condition, subjects were tested using broadband stimuli with a nominal input level of 65 dB SPL. Prior to presentation via Sennheiser HD580 earphones, the stimuli were subjected to the frequency-gain characteristic prescribed by the "Cambridge" formula, which is intended to give speech at 65 dB SPL the same overall loudness as for a normal listener, and to make the average loudness of the speech the same for each critical band over the frequency range important for speech intelligibility (in a listener without a dead region). The stimuli for all other conditions were initially subjected to this same frequency-gain characteristic. Then, the speech was low-pass filtered with various cutoff frequencies. For subjects without dead regions, performance generally improved progressively with increasing cutoff frequency. This indicates that they benefited from high-frequency information. For subjects with dead regions, two patterns of performance were observed. For most subjects, performance improved with increasing cutoff frequency until the cutoff frequency was somewhat above the estimated edge frequency of the dead region, but hardly changed with further increases. For a few subjects, performance initially improved with increasing cutoff frequency and then worsened with further increases, although the worsening was significant only for one subject. The results have important implications for the fitting of hearing aids.
Aviation, Space, and Environmental Medicine · Jul 2001
Arrabito GR, McFadden SM, Crabtree RB
Abstract
Background Auditory speech thresholds were measured in this study. Methods Subjects were required to discriminate a female voice recording of three-digit numbers in the presence of diotic speech babble. The voice stimulus was spatialized at 11 static azimuth positions on the horizontal plane using three different head-related transfer functions (HRTFs) measured on individuals who did not participate in this study. The diotic presentation of the voice stimulus served as the control condition. Results The results showed that two of the HRTFS performed similarly and had significantly lower auditory speech thresholds than the third HRTF. All three HRTFs yielded significantly lower auditory speech thresholds compared with the diotic presentation of the voice stimulus, with the largest difference at 60 degrees azimuth. Conclusion The practical implications of these results suggest that lower headphone levels of the communication system in military aircraft can be achieved without sacrificing intelligibility, thereby lessening the risk of hearing loss.
Behavioral Neuroscience · Jun 2001
Early SJ, Mason CR, Zheng L, … Carney LH
Abstract
A Pavlovian conditioned eyeblink response in rabbits (Oryctolagus cuniculus) was used to study psychoacoustical phenomena previously demonstrated in human listeners and other animals. This article contains the results of a tone-in-noise detection study to examine 2 psychoacoustical phenomena in rabbit and in human listeners: (a) the binaural masking level difference (BMLD) and (b) differential performance across reproducible noise masker waveforms. The rabbits demonstrated a BMLD comparable in size to other species. Significant differences in performance across reproducible noise masker waveforms were seen in the rabbits. This performance was compared with the performance of human listeners using the same set of waveforms.
The Journal of the Acoustical Society of America · Jun 2001
Eunmi L. Oh, Frederic Wightman, Robert A. Lutfi
Abstract
Preschoolers and adults were asked to detect a 1000-Hz signal, which was masked by a multitone complex. The frequencies and amplitudes of the components in the complex varied randomly and independently on each presentation. A staircase, cued two-interval, forced-choice procedure disguised as a “listening game” was used to obtain signal thresholds in quiet and in the presence of the multitone maskers. The number of components in the masker was fixed within an experimental condition and varied from 2 to 906 across experimental conditions. Thresholds were also measured with a broadband noise masker. Eight preschool children and eight adults were tested. Although individual differences were large, among both adults and children, there was little difference between the groups in the mean amount of masking produced by the maskers with large numbers of components (400 and 906). There was also a small but significant difference between adults and children in the mean amount of masking produced by the broadband noise. The difference between the groups was much larger with smaller numbers of components. Data obtained from the adults were basically similar to that previously reported [cf. Neff and Green, Percept. Psychophys. 41, 409–415 (1987); Oh and Lutfi, J. Acoust. Soc. Am. 104, 3489–3499 (1998)]: maskers comprised of 10–40 components produced as much as 30 to 60 dB of masking in some, but not all listeners. Those same maskers produced larger amounts of masking (70–83 dB) in many of the preschool children, although, as in the adult group, individual differences were large. The component-relative-entropy (CoRE) model [Lutfi, J. Acoust. Soc. Am. 94, 748–758 (1993)] was used to describe the differences in performance between the children and adults. According to this model the average child appears to integrate information over a larger number of auditory filters than the average adult.
The Journal of the Acoustical Society of America · May 2001
Micheal L. Dent, Robert J. Dooling
Abstract
When localizing sounds in a reverberant environment, the precedence effect allows us to localize direct sounds accurately while disregarding the many echoes in that environment. The precedence effect has been well studied behaviorally in humans and behaviorally and physiologically in other animals. Until now, however, precedence effect experiments in birds have been limited to barn owls. These birds have highly specialized auditory systems; nothing is really known about how unspecialized birds deal with competing sound sources. Budgerigars (Melopsittacus undulatus) are excellent subjects for this type of investigation since so much is known about their hearing. These birds have unremarkable sound localization abilities, but exhibit free-field binaural unmasking at amounts similar to those found in humans with much larger heads. We examined whether budgerigars exhibit the precedence effect, and if the phases of the precedence effect were similar to those found in humans and other animals. Psychoacoustic methods were used to measure the discrimination performance of click pairs from different locations separated by a short delay. The results suggest that budgerigars exhibit the precedence effect and that the time-courses are similar to those found in humans and other animals. [Work supported by NIH MH12698 to MLD and DC00198 to RJD.]
Hearing Research · May 2001
Glasberg BR, Moore BC, Peters RW
Abstract
This paper examines the influence of external and internal noise on the detection of increments and decrements in the level of sinusoidal pedestals. In experiment 1, the pedestals were presented either 18 dB above the masked threshold in broadband noise (condition 18-Masked) or 18 dB above the absolute threshold (condition 18-Abs). Pedestal frequencies were 250, 1000 or 4000 Hz, and increment/decrement durations ranged from 5 to 200 ms. For condition 18-Masked, thresholds decreased with increasing pedestal frequency, while for condition 18-Abs, thresholds did not change significantly with pedestal frequency. These results are consistent with the idea that, in condition 18-Masked, thresholds were influenced by the inherent fluctuations produced by the background noise at the output of the auditory filter centred at the pedestal frequency. These fluctuations would decrease in rate with decreasing centre frequency, and this might have a greater deleterious effect on performance. In contrast, the characteristics of the internal noise that presumably limited performance in condition 18-Abs do not appear to vary with pedestal frequency. In experiment 2, a 4000 Hz pedestal was used. It was presented either in quiet or in the presence of narrowband noise centred at 4000, or 7000 Hz, or both. The noise bandwidth ranged from 50 to 400 Hz. The increment/decrement duration ranged from 5 to 100 ms. The noise centred at 7000 Hz produced only a small deterioration in performance relative to that measured in quiet. The noise centred at 4000 Hz had a larger effect, and the effect increased with decreasing noise bandwidth. This is consistent with the idea that slow fluctuations at the output of the auditory filter impair increment and decrement detection more than rapid fluctuations. A model is proposed to account for the results, based on a simulated auditory filter, a compressive non-linearity, a sliding temporal integrator, a logarithmic transform and a template mechanism. Analysis using the model suggests that the effect of centre frequency observed in experiment 1, when background noise was present, cannot be explained entirely in terms of the fluctuations produced by the background noise at the output of the auditory filter centred at the pedestal frequency.
The Journal of the Acoustical Society of America · May 2001
Langendijk EH, Kistler DJ, Wightman FL
Abstract
Localizing a target sound can be a challenge when one or more distracter sounds are present at the same time. This study measured the effect of distracter position on target localization for one distracter (17 positions) and two distracters (21 combinations of 17 positions). Listeners were instructed to point to the apparent position of a train of 30-ms noise bursts, presented at 1 of 85 positions in virtual free field. A harmonic complex and a frequency-swept complex tone served as distracters. The two distracters were turned on 40 and 80 ms after the target onset, had temporal envelopes similar to that of the target, and did not overlap temporally with the target. Virtual sounds were synthesized with individual HRTFs. Localization performance degraded as the number of distracters increased from 0 to 2. When the horizontal distance between target and a single distracter was small (i.e., the interaural differences were almost the same), the influence on the apparent position was greater than when they were far apart. In the vertical dimension, there was not a systematic effect of distracter position on target localizability. However, there was a substantial increase in localization error for targets at high elevations (above 30 degrees) when distracters were present.
The Journal of the Acoustical Society of America · Apr 2001
Wojtczak M, Schroder AC, Kong YY, Nelson DA
Abstract
Masking period patterns (MPPs) were measured in listeners with normal and impaired hearing using amplitude-modulated tonal maskers and short tonal probes. The frequency of the masker was either the same as the frequency of the probe (on-frequency masking) or was one octave below the frequency of the probe (off-frequency masking). In experiment 1, MPPs were measured for listeners with normal hearing using different masker levels. Carrier frequencies of 3 and 6 kHz were used for the masker. The probe had a frequency of 6 kHz. For all masker levels, the off-frequency MPPs exhibited deeper and longer valleys compared with the on-frequency MPPs. Hearing-impaired listeners were tested in experiment 2. For some hearing-impaired subjects, masker frequencies of 1.5 kHz and 3 kHz were paired with a probe frequency of 3 kHz. MPPs measured for listeners with hearing loss had similar shapes for on- and off-frequency maskers. It was hypothesized that the shapes of MPPs reflect nonlinear processing at the level of the basilar membrane in normal hearing and more linear processing in impaired hearing. A model assuming different cochlear gains for normal versus impaired hearing and similar parameters of the temporal integrator for both groups of listeners successfully predicted the MPPs.