Nature · Apr 2001
Mason AC, Oshinsky ML, Hoy RR
Abstract
The physics of sound propagation imposes fundamental constraints on sound localization: for a given frequency, the smaller the receiver, the smaller the available cues. Thus, the creation of nanoscale acoustic microphones with directional sensitivity is very difficult. The fly Ormia ochracea possesses an unusual 'ear' that largely overcomes these physical constraints; attempts to exploit principles derived from O. ochracea for improved hearing aids are now in progress. Here we report that O. ochracea can behaviourally localize a salient sound source with a precision equal to that of humans. Despite its small size and minuscule interaural cues, the fly localizes sound sources to within 2 degrees azimuth. As the fly's eardrums are less than 0.5 mm apart, localization cues are around 50 ns. Directional information is represented in the auditory system by the relative timing of receptor responses in the two ears. Low-jitter, phasic receptor responses are pooled to achieve hyperacute timecoding. These results demonstrate that nanoscale/microscale directional microphones patterned after O. ochracea have the potential for highly accurate directional sensitivity, independent of their size. Notably, in the fly itself this performance is dependent on a newly discovered set of specific coding strategies employed by the nervous system.
The Journal of the Acoustical Society of America · Apr 2001
Krumbholz K, Schmidt S
Abstract
For echolocation, the gleaning bat Megaderma lyra relies on short and broadband calls consisting of multiple harmonic components, each of which is downward frequency modulated. The harmonic components in M. lyra's calls have a relatively small frequency excursion and do not overlap spectrally. Broadband calls of other bat species, on the other hand, often consist of only a few harmonics which are modulated over broad and sometimes overlapping frequency ranges. A call consisting of narrow and nonoverlapping harmonic components may provide a less complete representation of target structure than a call which consists of broadly modulated components. However, a multiharmonic call may help the bats to perceive local spectral changes in the echo from shifts in the peak frequencies of single harmonics, and thereby to extract additional information about the target. To assess this hypothesis, the accuracy with which M. lyra can analyze frequency shifts of single partials in multiharmonic complex tones was investigated. A two-alternative, forced-choice behavioral task was used to measure M. lyra's frequency discrimination threshold for the third partial in complex tones whose spectral composition resembled that of the bat's sonar calls. The discrimination threshold for the third partial in a 21.5-kHz harmonic tone amounted to about 2% and was similar to the bat's pure-tone discrimination threshold at 64.5 kHz. Discrimination performance was essentially unaffected by random frequency changes of the other partials and by reducing stimulus duration from 50.5 to 1.5 ms. Both findings are in accordance with predictions made on the basis of the shape of M. Ivra's cochlear filters. The comparison between the observed frequency discrimination performance and a computational estimate of the expected frequency shift in the third harmonic of an echo reflected by a simple, two-front target showed that M. lyra's frequency resolution is sufficient for analyzing the target-specific information conveyed by shifts in the peak frequency of single echo components.
The Journal of the Acoustical Society of America · Apr 2001
Ellermeier W, Eigenstetter M, Zimmer K
Abstract
In environmental noise surveys, self-reported noise sensitivity, a stable personality trait covering attitudes toward a wide range of environmental sounds, is a major predictor of individual noise-annoyance reactions. Its relationship to basic measures of auditory functioning, however, has not been systematically explored. Therefore, in the present investigation, a sample of 61 unselected listeners was subjected to a battery of psychoacoustic procedures ranging from threshold determinations to loudness scaling tasks. No significant differences in absolute thresholds, intensity discrimination, simple auditory reaction time, or power-function exponents for loudness emerged, when the sample was split along the median into two groups of "low" vs "high" noise sensitivity on the basis of scores obtained from a psychometrically evaluated questionnaire [Zimmer and Ellermeier, Diagnostica 44, 11-20 (1998)]. Small, but systematic differences were found in verbal loudness estimates, and in ratings of the unpleasantness of natural sounds, thus suggesting that self-reported noise sensitivity captures evaluative rather than sensory aspects of auditory processing.
European Journal of Neuroscience · Mar 2001
Langemann U, Klump GM
Abstract
Vertebrates have evolved mechanisms to exploit amplitude modulations in background noise for improving signal detection. However, the mechanisms underlying this masking release are not yet well understood. Here we present evidence for masking release observed in European starlings (Sturnus vulgaris, Aves) that were trained in a Go/NoGo paradigm to report the detection of a short tone (20 ms) in 100% sinusoidally amplitude-modulated noise maskers (400 ms duration). Maskers centred at the tone frequency were composed of one, three, or five spectrally adjacent noise bands each of auditory filter bandwidth. Envelopes of the masking noise bands were either in-phase (i.e. coherent) or successively phase shifted by 90 degrees (i.e. incoherent). A release from masking of up to 28 dB was observed for detection of signals presented in dips of the envelope of coherent maskers compared with those presented in peaks of coherent maskers and in incoherent maskers. For maskers limited to one auditory filter (i.e. limited to the analysis channel tuned to the test signal) this masking release was about 10 dB less than that observed for maskers allowing a comparison across three or five auditory filters. This indicates that both within-channel cues and across-channel cues are important for signal detection. These behavioural data provide the reference for the study of responses of auditory forebrain neurons in the same species reported in a companion paper [Nieder & Klump (2001) Eur. J. Neurosci., 13, 1033-1044].
The Journal of the Acoustical Society of America · Mar 2001
Noordhoek IM, Houtgast T, Festen JM
Abstract
Relations between perception of suprathreshold speech and auditory functions were examined in 24 hearing-impaired listeners and 12 normal-hearing listeners. The speech intelligibility index (SII) was used to account for audibility. The auditory functions included detection efficiency, temporal and spectral resolution, temporal and spectral integration, and discrimination of intensity, frequency, rhythm, and spectro-temporal shape. All auditory functions were measured at 1 kHz. Speech intelligibility was assessed with the speech-reception threshold (SRT) in quiet and in noise, and with the speech-reception bandwidth threshold (SRBT), previously developed for investigating speech perception in a limited frequency region around 1 kHz. The results showed that the elevated SRT in quiet could be explained on the basis of audibility. Audibility could only partly account for the elevated SRT values in noise and the deviant SRBT values, suggesting that suprathreshold deficits affected intelligibility in these conditions. SII predictions for the SRBT improved significantly by including the individually measured upward spread of masking in the SII model. Reduced spectral resolution, reduced temporal resolution, and reduced frequency discrimination appeared to be related to speech perception deficits. Loss of peripheral compression appeared to have the smallest effect on the intelligibility of suprathreshold speech.
Psychophysiology · Mar 2001
Bertoli S, Heimberg S, Smurzynski J, Probst R
Abstract
Temporal auditory processing deficits are thought to play an important role in some pathologies of speech understanding difficulties. The purposes of the present study were to determine whether short silent gaps within a pure tone can be used to elicit mismatch negativity (MMN) as an objective measure of temporal resolution, and to investigate the relation between MMN and performance on a behavioral gap-detection task. The stimuli used for both tasks were 1-kHz sinusoids presented in a low-pass masking noise. Behavioral gap-detection thresholds were determined using an adaptive three-alternative forced-choice procedure. To elicit MMN, a series of deviant stimuli with varying gap durations was generated and presented in an oddball paradigm among standard stimuli without a gap. Only the gaps larger than the mean behavioral gap-detection threshold evoked a clear MMN. There was no clear relation between psychoacoustic and MMN thresholds.
Journal of Neurophysiology · Feb 2001
Johnen A, Wagner H, Gaese BH
Abstract
Attentional influence on sound-localization behavior of barn owls was investigated in a cross-modal spatial cuing paradigm. After being cued to the most probable target side with a visual cuing stimulus, owls localized upcoming auditory target stimuli with a head turn toward the position of the sound source. In 80% of the trials, cuing stimuli pointed toward the side of the upcoming target stimulus (valid configuration), and in 20% they pointed toward the opposite side (invalid configuration). We found that owls initiated the head turns by a mean of 37.4 ms earlier in valid trials, i.e., mean response latencies of head turns were reduced by 16% after a valid cuing stimulus. Thus auditory stimuli appearing at the cued side were processed faster than stimuli appearing at the uncued side, indicating the influence of a spatial-selective attention mechanism. Turning angles were not different when owls turned their head toward a cued or an uncued location. Other types of attention influencing sound localization, e.g., a reduction of response latency as a function of the duration of cue-target delay, could not be observed. This study is the first attempt to investigate attentional influences on sound localization in an animal model.
Journal of the Association for Research in Otolaryngology · 2001
Poganiatz I, Nelken I, Wagner H
Abstract
Specific cues in a sound signal are naturally linked to certain parameters in acoustic space. In the barn owl, interaural time difference (ITD) varies mainly with azimuth, while interaural level difference (ILD) varies mainly with elevation. Previous data suggested that ITD is indeed the main cue for azimuthal sound localization in this species, while ILD is an important cue for elevational sound localization. The exact contributions of these parameters could be tested only indirectly because it was not possible to generate a stimulus that contained all relevant spatial information on the one hand, and allowed for a clean separation of these parameters on the other hand. Virtual auditory worlds offer this opportunity. Here we show that barn owls responded to azimuthal variations in virtual space in the same way as to variations in free-field stimuli. We interpret the increase of turning angle with sound-source azimuths (up to +/- 140 degrees) such that the owls did not experience front/back confusions with virtual stimuli. We then separated the influence of ITD from the influence of all other stimulus parameters by fixing the overall ITD in virtual stimuli to a constant value (+100 micros or +100 micros) while leaving all other sound characteristics unchanged. This manipulation influenced both azimuthal and elevational components of head arms. Since the owls' azimuthal head-turn amplitude always resembled the value signified by the ITD, these data demonstrated that azimuthal sound localization is influenced only by ITD both in the frontal hemisphere and in large parts of the rear hemisphere. ILDs did not have an influence on azimuthal components of head turns. While response latency to normal virtual stimuli was found to be largely independent of stimulus position, response delays of the head turns became longer if the ITD information pointed into a different hemisphere as the other cues of the sounds.
Journal of the Association for Research in Otolaryngology · 2001
Su TI, Recanzone GH
Abstract
The ability of humans to localize sounds remains relatively constant across a range of intensities well above detection threshold, and increasing the spectral content of the stimulus results in an improvement in localization ability. For broadband stimuli, intensities near detection threshold result in fewer and weaker binaural cues used in azimuth localization because the stimulus energy at the high- and low-frequency ends of the audible spectrum fall below detection threshold. Thus, the ability to localize broadband sounds in azimuth is predicted to be degraded at audible but near threshold stimulus intensities. The spectral cues for elevation localization (spectral peaks and notches generated by the head-related transfer function) span a narrower frequency range than those for azimuth. As the stimulus intensity decreases, the ability to detect the stimulus frequencies corresponding to the spectral notches will be more strongly affected than the ability to detect frequencies outside the range where these spectral cues are useful. Consequently, decreasing the stimulus intensity should degrade localization in both azimuth and elevation and create a greater deficit in elevation localization due to the narrower band of audible frequencies containing elevation cues compared to azimuth cues. The present study measured the ability of 11 normal human subjects to localize broadband noise stimuli along the midsagittal plane and horizontal meridian at stimulus intensities of 14, 22, and 30 dB above the subject's detection threshold using a go/no-go behavioral paradigm. Localization ability decreased in both azimuth and elevation with decreasing stimulus intensity, and this effect was greater on localization in elevation than on localization in azimuth. The differential effects of stimulus intensity on sound localization in azimuth and elevation found in the present study may provide a valuable tool in investigating the neural correlates of sound location perception.
Interdisciplinary Information Sciences · 2001
Kunihiro KUMAGAI, Kenji OZAWA, Yôiti SUZUKI, Toshio SONE
Abstract
This paper discusses multidimensional perceptual space derived from the results of psychoacoustical experiments on similarities in the quality of sounds amplitude-modulated by nine triangular waves different in rise- and fall-times. For sinusoidal (1 kHz) and random-noise carriers, three experiments were conducted with different modulation frequencies, namely 8, 16 and 32 Hz. In each experiment, similarities in sound quality for stimuli with modulation depths of 0.4, 0.8 and 1.0, as well as the original carrier wave, were rated. The similarities were analyzed by a multidimensional scaling method (ALSCAL), and three-dimensional configurations were derived. A common configuration correlated with the modulation depth was seen irrespective of carrier wave and modulation frequency. There was a perceptual dimension related to shape of amplitude modulation for all conditions except for noise carrier with 32-Hz modulation. The difference in rise time caused larger differences in sound quality than similar differences in fall time up to a modulation frequency of 16 Hz, irrespective of the kind of carrier wave.
Echolocation in Bats · 2001
CE Schlundt, DA Carder, SH Ridgway
2001
SJ Aiken
Human Factors: the Journal of the Human Factors and Ergonomics Society · 2001
Abouchacra KS, Breitenbach J, Mermagen T, Letowski T
Abstract
This study assessed the effects of spatialized sound presentation on a listener's ability to monitor target (T) messages in the presence of competing (C) messages and high-level (110 dB[A]) background noise (BGN). In a simulated military environment, 8 participants wore two-channel, active noise reduction (ANR) equipped helmets and listened to combinations of T and C messages (89 dB[A] at the ear). T messages were presented synchronously with 0, 1, 2, and 3 C messages in four listening modes: (a) BGN + diotic, (b) BGN + dichotic, (c) BGN + spatial audio, and (d) quiet + spatial audio. Best overall performance occurred in the spatialized modes (c and d) and poorest in the diotic mode (a). As expected, speech recognition was better in quiet than in BGN when multiple C messages were present. Findings indicate that message spatialization in acoustic space improves auditory performance during times of heavy message competition, even in high-level noise. The proposed technology has numerous applications, such as multichannel communications in tactical operations centers, monitoring of complex security systems, and air traffic control.
The Journal of the Acoustical Society of America · 2001
Litovsky RY, Shinn-Cunningham BG
Abstract
Listeners have a remarkable ability to localize and identify sound sources in reverberant environments. The term "precedence effect" (PE; also known as the "Haas effect," "law of the first wavefront," and "echo suppression") refers to a group of auditory phenomena that is thought to be related to this ability. Traditionally, three measures have been used to quantify the PE: (1) Fusion: at short delays (1-5 ms for clicks) the lead and lag perceptually fuse into one auditory event; (2) Localization dominance: the perceived location of the leading source dominates that of the lagging source; and (3) Discrimination suppression: at short delays, changes in the location or interaural parameters of the lag are difficult to discriminate compared with changes in characteristics of the lead. Little is known about the relation among these aspects of the PE, since they are rarely studied in the same listeners. In the present study, extensive measurements of these phenomena were made for six normal-hearing listeners using 1-ms noise bursts. The results suggest that, for clicks, fusion lasts 1-5 ms; by 5 ms most listeners hear two sounds on a majority of trials. However, localization dominance and discrimination suppression remain potent for delays of 10 ms or longer. Results are consistent with a simple model in which information from the lead and lag interacts perceptually and in which the strength of this interaction decreases with spatiotemporal separation of the lead and lag. At short delays, lead and lag both contribute to spatial perception, but the lead dominates (to the extent that only one position is ever heard). At the longest delays tested, two distinct sounds are perceived (as measured in a fusion task), but they are not always heard at independent spatial locations (as measured in a localization dominance task). These results suggest that directional cues from the lag are not necessarily salient for all conditions in which the lag is subjectively heard as a separate event.
The Journal of the Acoustical Society of America · Dec 2000
Irvine DR, Martin RL, Klimkeit E, Smith R
Abstract
On a variety of visual tasks, improvement in perceptual discrimination with practice (perceptual learning) has been found to be specific to features of the training stimulus, including retinal location. This specificity has been interpreted as evidence that the learning reflects changes in neuronal tuning at relatively early processing stages. The aim of the present study was to examine the frequency specificity of human auditory perceptual learning in a frequency discrimination task. Difference limens for frequency (DLFs) were determined at 5 and 8 kHz, using a three-alternative forced choice method, for two groups of eight subjects before and after extensive training at one or the other frequency. Both groups showed substantial improvement at the training frequency, and much of this improvement generalized to the nontrained frequency. However, a small but statistically significant component of the improvement was specific to the training frequency. Whether this specificity reflects changes in neural frequency tuning or attentional changes remains unclear.
Hearing Research · Nov 2000
Norena A, Micheyl C, Chery-Croze S
Abstract
The Zwicker tone (ZT) is an auditory after-image, i.e. a tonal sensation that occurs following the presentation of notched noise. In the present study, the hypothesis that neural lateral inhibition is involved in the generation of this auditory illusion was investigated in humans through differences in perceptual detection thresholds measured following broadband noise, notched noise, and low-pass noise stimulation. The detection thresholds were measured using probe tones at several frequencies, within as well as outside the suppressed frequency range of the notched noise, and below as well as above the corner frequency of the low-pass noise. Thresholds measured after broadband noise using a sequence of four 130-ms probe tones (with a 130-ms inter-burst interval) proved to be significantly smaller that those measured using the same probe tones after notched noise at frequencies falling within the notch, but larger for frequencies on the outer edges of the noise. Thresholds measured following low-pass noise using the same sequence of probe tones were found to be smaller at frequencies slightly above the corner, but larger at lower, neighboring frequencies. This pattern of results is consistent with the hypothesis that the changes in auditory sensitivity induced by stimuli containing sharp spectral contrasts reflect lateral inhibition processes in the auditory system. The potential implications of these findings for the understanding of the mechanisms underlying the generation of auditory illusions like the ZT or tinnitus are discussed.
Hearing Research · Nov 2000
Shofner WP
Abstract
Frequency discrimination thresholds were measured from five chinchillas for harmonic tone complexes having a fundamental frequency of 250 Hz. Stimuli consisted of the fundamental frequency and the second through 10th harmonics with individual components added in either cosine phase or random phase. In general, thresholds were independent of overall level for sound levels between 47 and 77 dB SPL, and there was no difference in thresholds observed between cosine-phase tone complexes and random-phase tone complexes. Discrimination thresholds were also obtained for a single 250-Hz tone for comparison with complex tone thresholds. Similar to data reported in human subjects, thresholds in chinchillas for tone complexes were lower than thresholds obtained using a single tone, although chinchillas required a larger frequency difference than human listeners. The results suggest that the mechanisms of frequency discrimination of complex tones are similar between chinchillas and human listeners.
The Journal of the Acoustical Society of America · Nov 2000
Litovsky RY, Hawley ML, Fligor BJ, Zurek PM
Abstract
Studies of the precedence effect using two binaural clicks have shown that listeners' ability to discriminate changes in the interaural time difference (ITD) of the lagging click is much poorer than that for the leading click [e.g., Zurek, J. Acoust. Soc. Am. 67, 952-964 (1980)]. This difference is thought to reflect an auditory process that suppresses directional information from the lagging sound and attributes greater perceptual weight to directional information contained in the leading one. A report by Saberi and Perrott [J. Acoust. Soc. Am. 87, 1732-1737 (1990)] suggested that listeners can "unlearn" this suppression of the lag's directional information after training with an adaptive psychophysical procedure involving 100 reversals and extremely small step sizes. Here, an attempt was made to find a similar effect using psychophysical procedures that are more common to precedence studies. Eight subjects were rigorously trained on the precedence task using either a blocked procedure or an adaptive procedure to vary ITD. Listeners showed no sign of unlearning. After 9-31 h of participating in the task, all subjects maintained high lag just-noticeable differences (jnd's) and low single source jnd's. This failure to train away the precedence effect (as manifested in discrimination suppression) suggests that directional information contained in the lagging source is not easily accessed. Several possible explanations for the discrepancies between the present study and Saberi and Perrott's finding are discussed.
The Journal of the Acoustical Society of America · Nov 2000
Glasberg BR, Moore BC
Abstract
Thresholds for detecting sinusoidal signals were measured as a function of the spectral width of a notch in a noise masker. The notch was positioned both symmetrically and asymmetrically around the signal frequency. The noise was designed to create equal excitation per ERB within its passbands (uniformly exciting noise), after allowing for the transfer function of the headphone and the middle ear. For a signal frequency of 250 Hz, the level per ERB ranged from 35 to 80 dB in 15-dB steps. For signal frequencies of 500, 1,000, 2,000, and 4,000 Hz, the level per ERB ranged from 40 to 70 dB per ERB in 15-dB steps. Auditory filter shapes were derived from the data by modeling the auditory filter as the sum of a sharply tuned tip filter and a broader tail filter. The gain of the tip filter was assumed to be a function of level. The shape of the tip filter and the gain and shape of the tail filter were assumed to be level independent. The data for all levels were fitted simultaneously. The data were fitted best when the gain of the tip filter was assumed to be a function of the signal level (as opposed to the masker level per ERB). The filter shapes showed a level dependence that qualitatively resembled the level dependence of filtering on the basilar membrane. The maximum gain of the tip filter tended to increase with increasing center frequency up to 1 kHz, but to remain roughly constant for higher frequencies.
Hearing Research · Oct 2000
Alcántara JI, Moore BC, Vickers DA
Abstract
Masking patterns for a 2-kHz sinusoidal masker at 45, 65 or 85 dB SPL were measured for three normal-hearing subjects, using a 3-AFC method with feedback (condition 1). The patterns showed distinct irregularities, particularly at the highest masker level. In condition 2, a lowpass noise was added to mask combination tones. The noise increased thresholds mainly for the 85 dB masker, for signal frequencies of 2.3-3.0 kHz. In condition 3, a pair of high-frequency tones ('modulation detection interference (MDI) tones') was used to introduce beats at the same rate as produced by the interaction of the masker and signal. Thresholds were higher than for condition 1, particularly for signal frequencies adjacent to the masker frequency. In condition 4, the lowpass noise was presented simultaneously with the MDI tones. Thresholds were well predicted as a combination of the effects of the lowpass noise and the MDI tones. In condition 5, a pair of low-frequency MDI tones was added to the masker. The thresholds had the same overall pattern as in condition 4. We conclude that the shapes of masking patterns measured using a 2-kHz masker are influenced by the detection of beats for masker-signal frequency separations up to at least 300 Hz and by the detection of combination tones for separations between 300 and 1000 Hz.