Clinical and Experimental Otorhinolaryngology · Aug 2026
Woongsang Sunwoo, Yeeun Kim
Abstract
Objectives. Spatial mapping of sound frequencies along the auditory pathway is refined through sound-evoked activity during early development. However, how neonatal auditory deprivation alters this organization remains unclear. This study examined frequency-specific spatial representations in the inferior colliculus (IC) using targeted low-frequency (apical) and high-frequency (basal) cochlear stimulation, enabling direct evaluation of low-frequency pathway integrity after neonatal deafness.Methods. Sixteen Sprague-Dawley rats (8 normal-hearing [NH] and 8 neonatally deafened [ND]) were studied. Neonatal deafness was induced by daily kanamycin injections from postnatal days 4 to 17. At 8–10 weeks of age, all animals underwent unilateral cochlear implantation with bipolar electrode pairs positioned in apical and basal cochlear regions to activate low- and high-frequency pathways. Multiunit responses were recorded from the contralateral IC using a multichannel linear electrode array. Spatial tuning curves (STCs) based on cumulative discriminability were used to assess thresholds, spread of excitation, and tonotopic precision. Spiral ganglion neuron (SGN) density was quantified histologically.Results. Despite 48%–67% SGN loss across cochlear turns, electrically evoked auditory brainstem response thresholds and IC thresholds were comparable between groups, indicating preserved peripheral excitability. However, ND rats exhibited significantly broader STCs (P=0.002) and reduced dorsoventral separation of apical and basal best sites (1.18± 0.67 mm vs. 1.80±0.40 mm, P=0.039), reflecting degraded central tonotopic precision. The effects were most pronounced for apical (low-frequency) stimulation, consistent with the selective vulnerability of low-frequency pathways to early auditory deprivation.Conclusion. These findings provide direct physiological evidence that early auditory experience is critical for refining frequency-organized connectivity in the auditory midbrain. The preferential degradation of apical (low-frequency) spatial tuning offers translational insights for optimizing stimulation strategies in early-onset deafness.
IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2026
W. Mitchel Thomas, Richard K. Gurgel, Loren Rieth, … David J. Warren
Abstract
Objective: The purpose of this paper is to present a chronic, preclinical, pilot study of a multi-electrode auditory nerve implant. To date, the most successful auditory neuroprosthesis is the cochlear implant, but these devices have known limitations. Intraneural stimulation of the auditory nerve is a promising alternative, but preclinical investigations of multi-electrode devices have been limited to acute or semi-chronic studies. Methods: Six cats were chronically implanted in the right auditory nerve with a 15-channel Utah Slant ArrayTM. The array's position in the internal auditory canal was confirmed using computed tomography. Electrode impedance and evoked responses were recorded regularly during the indwelling period to evaluate performance. Results: Two of the six implants met endpoint criteria at 6 months, with stable electrode impedances and robust evoked responses on at least 50% of their channels. Another two implants exhibited stable electrode impedances, but activation thresholds increased over three months. Two implants failed within the first two weeks due to device migration caused by connector-related issues. Conclusion: This study reports the first successful chronic deployment of an multi-electrode auditory nerve implant in a preclinical model. Two implanted cats exhibited stable chronic performance, marked by a consistent set of electrodes capable of eliciting evoked responses. The failure modes of the remaining four cats are discussed and recommendations are made to stabilize implant placement. The study lays a solid foundation for future chronic safety and efficacy investigations as part of an effort to translate this new neuroprosthetic technology into the clinic.
Communications Biology · Dec 2025
Jazmín S. Sánchez, David Pérez-González, Manuel S. Malmierca
Abstract
The hippocampus is classically linked to memory, yet increasing evidence points to a broader role in perceptual inference and deviance detection. Predictive coding theories propose that perception minimizes mismatches between expected and actual sensory input, expressed in neural signatures such as mismatch negativity (MMN) and P300. Although MMN arises mainly from sensory and prefrontal cortices, the hippocampus is anatomically interconnected with both and may also contribute to prediction error processing. We recorded single- and multi-unit activity and local field potentials (LFPs) from DG and CA1 in urethane-anesthetized rats during an auditory oddball paradigm and a no-repetition control sequence to dissociate prediction error from repetition suppression. Approximately 20% of hippocampal neurons were sound responsive, and a subset showed deviant selectivity. Spiking activity predominantly reflected prediction errors, while LFPs revealed complementary contributions from repetition suppression and prediction error. Early LFP components were enhanced for randomly presented deviants, whereas later components within the P300 latency range were stronger for predictable deviants, indicating temporally distinct phases of error signaling and top-down modulation. These findings identify the hippocampus as an active contributor to auditory deviance detection and support a hierarchical model in which hippocampal circuits participate in predictive sensory processing beyond memory.
Experimental Physiology · Nov 2025
Laura H Bohórquez, Manuel S Malmierca, Adam Hockley
Abstract
Context‐dependent sensory processing within the predictive coding framework relies on detecting mismatches between incoming stimuli and internal predictive models. Sensory deviants elicit prediction errors, seen as enhanced neural responses, that update these models and influence attention and behaviour. Although prediction errors have been widely observed across brain regions, the downstream processes remain poorly understood. In this study, we recorded electrocorticography in five urethane‐anaesthetised rats and identified cortical slow oscillations, characterised by spontaneous transitions between ‘Up’ and ‘Down’ states. Deviant stimuli in an auditory oddball paradigm evoked an initial positive prediction error, followed by a prolonged, all‐or‐nothing response which spread in a travelling wave across the cortex. Identified as putative evoked cortical Up states, these responses were not evoked by standards, omissions or a many‐standards control. Up states following deviants occurred more recently after a previous Up state when compared to spontaneous Up states. In preliminary data from an awake rat, long‐latency Up states were not present spontaneously or evoked. In a different rat, anaesthetic depth was key to spontaneous and evoked Up states, with more robust Up/Down states and more reliable triggering of Up states under deeper anaesthesia. These results suggest that sensory deviants may cause shifts in cortical state under anaesthesia, explaining the long‐latency mismatch response under anaesthesia and sleep.
Journal of Neurodevelopmental Disorders · Nov 2025
Yanya Ding, Jingyu Feng, Viollandi Prifti, … Kuan Hong Wang
Abstract
Background CLN3 disease, also known as juvenile Batten disease, is a recessively inherited neurodevelopmental disorder caused by mutations in the CLN3 gene. It represents the most common form of Neuronal Ceroid Lipofuscinoses (NCLs), a group of lysosomal storage disorders that impair brain function. Clinical features include progressive vision loss, language impairment, and cognitive decline. The early onset of visual deficits complicates the neurological assessment of cognitive dysfunction, while the rarity of CLN3 cases limits the study of sex-specific disease trajectories in humans. Therefore, there is a critical need for objective, translational biomarkers to monitor disease progression and support therapeutic development in preclinical animal models. Methods Building on our recent studies in individuals with CLN3 disease, we developed a parallel experimental paradigm using high-density electroencephalography (EEG) in Cln3 knockout ( Cln3-/-) mice to longitudinally assess auditory neurophysiological changes. We applied a duration-based mismatch negativity (MMN) paradigm, similar to that used in our human studies, to evaluate automatic detection of auditory pattern changes in male and female mice between 3 and 9 months of age. Results Wild-type (WT) mice of both sexes showed robust and stable duration MMN responses across this age range. In contrast, Cln3-/- mice showed marked sex- and age-dependent deficits: female mutants displayed persistent MMN deficits, whereas male mutants exhibited early MMN abnormalities that unexpectedly improved with age. Auditory brainstem responses confirmed intact peripheral hearing in Cln3-/- mice, indicating a central origin for the observed abnormalities. Further analyses revealed that MMN impairments were driven by age- and sex-specific alterations in auditory evoked potentials to both standard and deviant stimuli. Conclusions These findings demonstrate sex- and age-dependent disruptions in central auditory processing in Cln3-/- mice and support auditory duration MMN as a sensitive, translational biomarker of brain dysfunction in CLN3 disease. This approach offers a functional, cross-species measure for tracking disease progression and evaluating therapeutic interventions in Batten disease.
Frontiers in Neuroscience · Apr 2025
Emily M. Fabrizio-Stover, Christopher M. Lee, Douglas L. Oliver, Alice L. Burghard
Abstract
Introduction Tinnitus is the perception of non-meaningful sound in the absence of external stimuli. Although tinnitus behavior in animal models is associated with altered central nervous system activity, it is not currently possible to identify tinnitus using neuronal activity alone. In the mouse inferior colliculus (IC), a subpopulation of neurons demonstrates a sustained increase in spontaneous activity after a long-duration sound (LDS). Methods Here, we use the “ LDS test ” to reveal tinnitus-specific differences in sound-evoked plasticity through IC extracellular recordings and the auditory brainstem response (ABR LDS ) in CBA/CaJ mice after sound exposure and behavioral tinnitus assessment. Results Sound-exposed mice showed stronger and shorter tone-evoked responses in the IC compared to unexposed controls, but these differences were not strong predictors of tinnitus. In contrast, in the LDS test, non-tinnitus mice had a significantly stronger suppression in tone-evoked spike rate compared to tinnitus and unexposed control mice. ABR peak amplitudes also revealed robust differences between tinnitus and non-tinnitus mice, with ABR peaks from non-tinnitus mice exhibiting significantly stronger suppression in the LDS test compared to tinnitus and control mice. No significant differences were seen between cohorts in ABR amplitude, latency, wave V:I ratio, wave V:III ratio, I-V intra-peak latency, and I-VI intra-peak latency. We found high-frequency tone stimuli better suited to reveal tinnitus-specific differences for both extracellular IC and ABR recordings. Discussion We successfully used the LDS test to demonstrate that tinnitus-specific differences in sound-evoked plasticity can be shown using both multi-unit near-field recordings in the IC and non-invasive far-field recordings, providing a foundation for future electrophysiological research into the causes and treatment of tinnitus.
Nature Communications · Aug 2024
Daniela Rodrigues-Amorim, P. Lorenzo Bozzelli, TaeHyun Kim, … Li-Huei Tsai
Abstract
Demyelination is a common pathological feature in a wide range of diseases, characterized by the loss of myelin sheath and myelin-supporting oligodendrocytes. These losses lead to impaired axonal function, increased vulnerability of axons to damage, and result in significant brain atrophy and neuro-axonal degeneration. Multiple pathomolecular processes contribute to neuroinflammation, oligodendrocyte cell death, and progressive neuronal dysfunction. In this study, we use the cuprizone mouse model of demyelination to investigate long-term non-invasive gamma entrainment using sensory stimulation as a potential therapeutic intervention for promoting myelination and reducing neuroinflammation in male mice. Here, we show that multisensory gamma stimulation mitigates demyelination, promotes oligodendrogenesis, preserves functional integrity and synaptic plasticity, attenuates oligodendrocyte ferroptosis-induced cell death, and reduces brain inflammation. Thus, the protective effects of multisensory gamma stimulation on myelin and anti-neuroinflammatory properties support its potential as a therapeutic approach for demyelinating disorders.
Bioelectronic Medicine · Jul 2024
Danny V. Lam, Justin Chin, Meagan K. Brucker-Hahn, … Igor Lavrov
Abstract
Background Spinal cord stimulation (SCS) has demonstrated multiple benefits in treating chronic pain and other clinical disorders related to sensorimotor dysfunctions. However, the underlying mechanisms are still not fully understood, including how electrode placement in relation to the spinal cord neuroanatomy influences epidural spinal recordings (ESRs). To characterize this relationship, this study utilized stimulation applied at various anatomical sections of the spinal column, including at levels of the intervertebral disc and regions correlating to the dorsal root entry zone. Method Two electrode arrays were surgically implanted into the dorsal epidural space of the swine. The stimulation leads were positioned such that the caudal-most electrode contact was at the level of a thoracic intervertebral segment. Intraoperative cone beam computed tomography (CBCT) images were utilized to precisely determine the location of the epidural leads relative to the spinal column. High-resolution microCT imaging and 3D-model reconstructions of the explanted spinal cord illustrated precise positioning and dimensions of the epidural leads in relation to the surrounding neuroanatomy, including the spinal rootlets of the dorsal and ventral columns of the spinal cord. In a separate swine cohort, implanted epidural leads were used for SCS and recording evoked ESRs. Results Reconstructed 3D-models of the swine spinal cord with epidural lead implants demonstrated considerable distinctions in the dimensions of a single electrode contact on a standard industry epidural stimulation lead compared to dorsal rootlets at the dorsal root entry zone (DREZ). At the intervertebral segment, it was observed that a single electrode contact may cover 20-25% of the DREZ if positioned laterally. Electrode contacts were estimated to be ~0.75 mm from the margins of the DREZ when placed at the midline. Furthermore, ventral rootlets were observed to travel in proximity and parallel to dorsal rootlets at this level prior to separation into their respective sides of the spinal cord. Cathodic stimulation at the level of the intervertebral disc, compared to an ‘off-disc’ stimulation (7 mm rostral), demonstrated considerable variations in the features of recorded ESRs, such as amplitude and shape, and evoked unintended motor activation at lower stimulation thresholds. This substantial change may be due to the influence of nearby ventral roots. To further illustrate the influence of rootlet activation vs. dorsal column activation, the stimulation lead was displaced laterally at ~2.88 mm from the midline, resulting in variances in both evoked compound action potential (ECAP) components and electromyography (EMG) components in ESRs at lower stimulation thresholds. Conclusion The results of this study suggest that the ECAP and EMG components of recorded ESRs can vary depending on small differences in the location of the stimulating electrodes within the spinal anatomy, such as at the level of the intervertebral segment. Furthermore, the effects of sub-centimeter lateral displacement of the stimulation lead from the midline, leading to significant changes in electrophysiological metrics. The results of this pilot study reveal the importance of the small displacement of the electrodes that can cause significant changes to evoked responses SCS. These results may provide further valuable insights into the underlying mechanisms and assist in optimizing future SCS-related applications.
Bioelectronic Medicine · Jul 2023
Lauren Savannah Dewberry, Ken Porche, Travis Koenig, … Kevin J. Otto
Abstract
Background The purpose of this study was to evaluate if kilohertz frequency alternating current (KHFAC) stimulation of peripheral nerve could serve as a treatment for lumbar radiculopathy. Prior work shows that KHFAC stimulation can treat sciatica resulting from chronic sciatic nerve constriction. Here, we evaluate if KHFAC stimulation is also beneficial in a more physiologic model of low back pain which mimics nucleus pulposus (NP) impingement of a lumbar dorsal root ganglion (DRG). Methods To mimic a lumbar radiculopathy, autologous tail NP was harvested and placed upon the right L5 nerve root and DRG. During the same surgery, a cuff electrode was implanted around the sciatic nerve with wires routed to a headcap for delivery of KHFAC stimulation. Male Lewis rats (3 mo., n = 18) were separated into 3 groups: NP injury + KHFAC stimulation ( n = 7), NP injury + sham cuff ( n = 6), and sham injury + sham cuff ( n = 5). Prior to surgery and for 2 weeks following surgery, animal tactile sensitivity, gait, and static weight bearing were evaluated. Results KHFAC stimulation of the sciatic nerve decreased behavioral evidence of pain and disability. Without KHFAC stimulation, injured animals had heightened tactile sensitivity compared to baseline ( p < 0.05), with tactile allodynia reversed during KHFAC stimulation ( p < 0.01). Midfoot flexion during locomotion was decreased after injury but improved with KHFAC stimulation ( p < 0.05). Animals also placed more weight on their injured limb when KHFAC stimulation was applied ( p < 0.05). Electrophysiology measurements at end point showed decreased, but not blocked, compound nerve action potentials with KHFAC stimulation ( p < 0.05). Conclusions KHFAC stimulation decreases hypersensitivity but does not cause additional gait compensations. This supports the idea that KHFAC stimulation applied to a peripheral nerve may be able to treat chronic pain resulting from sciatic nerve root inflammation.
Bioelectronic Medicine · Feb 2023
Nishant Verma, Ben Romanauski, Danny Lam, … Mingming Zhang
Abstract
Background Epidural electrical stimulation (EES) of the spinal cord has been FDA approved and used therapeutically for decades. However, there is still not a clear understanding of the local neural substrates and consequently the mechanism of action responsible for the therapeutic effects. Method Epidural spinal recordings (ESR) are collected from the electrodes placed in the epidural space. ESR contains multi-modality signal components such as the evoked neural response (due to tonic or BurstDR™ waveforms), evoked muscle response, stimulation artifact, and cardiac response. The tonic stimulation evoked compound action potential (ECAP) is one of the components in ESR and has been proposed recently to measure the accumulative local potentials from large populations of neuronal fibers during EES. Result Here, we first review and investigate the referencing strategies, as they apply to ECAP component in ESR in the domestic swine animal model. We then examine how ECAP component can be used to sense lead migration, an adverse outcome following lead placement that can reduce therapeutic efficacy. Lastly, we show and isolate concurrent activation of local back and leg muscles during EES, demonstrating that the ESR obtained from the recording contacts contain both ECAP and EMG components. Conclusion These findings may further guide the implementation of recording and reference contacts in an implantable EES system and provide preliminary evidence for the utility of ECAP component in ESR to detect lead migration. We expect these results to facilitate future development of EES methodology and implementation of use of different components in ESR to improve EES therapy.
eneuro · 2023
Woongsang Sunwoo
Abstract
We examined the effect of neonatal deafening on frequency-specific pathways for processing of interaural time differences (ITDs) in cochlear-implant stimuli. Animal studies have demonstrated differences in neural ITD sensitivity in the inferior colliculus (IC) depending on the intracochlear location of intracochlear stimulating electrodes. We used neonatally deafened (ND) rats of both sexes and recorded the responses of single neurons in the IC to electrical stimuli with ITDs delivered to the apical or basal cochlea and compared them with acutely deafened (AD) rats of both sexes with normal hearing (NH) during development. We found that neonatal deafness significantly impacted the ITD sensitivity and the ITD tuning patterns restricted to apically driven IC neurons. In ND rats, the ITD sensitivity of apically driven neurons is reduced to values similar to basally driven neurons. The prevalence of ITD-sensitive apical neurons with a peak-shaped ITD tuning curve, which may reflect predominant input from the medial superior olivary (MSO) complex, in ND rats was diminished compared with that in AD rats (67%, AD vs 40%, ND). Conversely, monotonic-type responses rarely occurred in AD rats (14%) but were approximately equally as prevalent as peak-type tuning curves in ND rats (42%). Nevertheless, in ND rats, the ITD at the maximum slope of the ITD tuning curve was still more concentrated within the physiological ITD range in apically driven than in basally driven neurons. These results indicate that the development of high ITD sensitivity processed by low-frequency pathways depends on normal auditory experience and associated biases in ITD tuning strategies.
Frontiers in Behavioral Neuroscience · Oct 2022
Emily M. Fabrizio-Stover, Grace Nichols, Jamie Corcoran, … Douglas L. Oliver
Abstract
Animal research focused on chronic tinnitus associated with noise-induced hearing loss can be expensive and time-consuming as a result of the behavioral training required. Although there exist a number of behavioral tests for tinnitus; there have been few formal direct comparisons of these tests. Here, we evaluated animals in two different tinnitus assessment methods. CBA/CaJ mice were trained in an operant conditioning, active avoidance (AA) test, and a reflexive, gap-induced pre-pulse inhibition of acoustic startle (GPIAS) test, or both. Tinnitus was induced in awake mice by unilateral continuous sound exposure using a 2-kHz- or 1 2 octave-wide noise centered at 16 kHz and presented at 113- or 116-dB SPL. Tinnitus was assessed 8 weeks after sound overexposure. Most mice had evidence of tinnitus behavior in at least one of the two behaviors. Of the mice evaluated in AA, over half (55%) had tinnitus positive behavior. In GPIAS, fewer animals (13%) were positive than were identified using the AA test. Few mice were positive in both tests (10%), and only one was positive for tinnitus behavior at the same spectral frequency in both tests. When the association between tinnitus behavior and spontaneous activity recorded in the inferior colliculus was compared, animals with tinnitus behavior in AA exhibited increased spontaneous activity, while those positive in GPIAS did not. Thus, it appears that operant conditioning tests, like AA, maybe more reliable and accurate tests for tinnitus than reflexive tests.
Nature Communications · May 2022
Kelsey L. Anbuhl, Justin D. Yao, Robert A. Hotz, … Dan H. Sanes
Abstract
Elevated neural plasticity during development contributes to dramatic improvements in perceptual, motor, and cognitive skills. However, malleable neural circuits are vulnerable to environmental influences that may disrupt behavioral maturation. While these risks are well-established prior to sexual maturity (i.e., critical periods), the degree of neural vulnerability during adolescence remains uncertain. Here, we induce transient hearing loss (HL) spanning adolescence in gerbils, and ask whether behavioral and neural maturation are disrupted. We find that adolescent HL causes a significant perceptual deficit that can be attributed to degraded auditory cortex processing, as assessed with wireless single neuron recordings and within-session population-level analyses. Finally, auditory cortex brain slices from adolescent HL animals reveal synaptic deficits that are distinct from those typically observed after critical period deprivation. Taken together, these results show that diminished adolescent sensory experience can cause long-lasting behavioral deficits that originate, in part, from a dysfunctional cortical circuit.
Frontiers in Systems Neuroscience · Apr 2020
Michael J. Simpson, Skyler G. Jennings, Robert H. Margolis
Abstract
There are several technical challenges to obtaining high-quality recordings of cochlear potentials in human electrocochleography (ECochG). These challenges include electrical artifacts from devices such as acoustic transducers, biological artifacts from excessive myogenic and electroencephalographic potentials, and issues associated with the placement of a tympanic membrane (TM) electrode on the eardrum. This article presents approaches for dealing with these challenges for ECochG measurement using a TM electrode. Emphasis is placed on eliminating stimulus artifact, optimizing the placement of the electrode, and comparing a custom-made electrode with a commercially-available electrode. This comparison revealed that the custom-made electrode results in greater subject comfort, superior ease of placing the electrode on the eardrum, and larger compound action potential (CAP) amplitudes.