Menu

Publications using the MS16

3 published studies used the MS16.

bioRxiv · Nov 2017

Global State Changes Induce Non-reciprocal Reduction of Mutual Information in the Thalamocortical Network (opens in a new tab)

Ryan Verner, Matthew Banks, Edward Bartlett

Abstract

Understanding the neural mechanisms of loss and recovery of consciousness remains an active area of scientific and clinical interest. Recent models and theories of consciousness implicate thalamus or neocortex as the dominant regions that control global state change, but experimentally testing these theories requires parsing the response properties of the complex thalamocortical network. In this work, we explore information processing using chronic recordings of multiunit activity between thalamus and cortex by targeting either the corticothalamic or thalamocortical pathway with direct electrical stimulation under subhypnotic and just-hypnotic states of isoflurane or dexmedetomidine induced unconsciousness. We found that mutual information between the stimulus and response in the corticothalamic circuit decreases with loss of consciousness, and that the change is not reciprocated in the thalamocortical direction. These changes in mutual information were moderately correlated with changes in evoked rate, and a strong effect of isoflurane on spontaneous and evoked rate accounts for a large portion of the change in mutual information. Further, we found cortical synchrony to increase under sub-and just-hypnotic doses of dexmedetomidine and isoflurane, suggesting cortical responses become more causally dependent on thalamocortical input at reduced levels of consciousness, or unconsciousness. We believe these changes suggest loss of consciousness is associated with a decrease in the number of available cortical network states, and may suggest cognitive unbinding from ascending sensory input.

Nature Medicine · Jan 2016

Spatiotemporal neuromodulation therapies engaging muscle synergies improve motor control after spinal cord injury (opens in a new tab)

Nikolaus Wenger, Eduardo Martin Moraud, Jerome Gandar, … Grégoire Courtine

Abstract

Electrical neuromodulation of lumbar segments improves motor control after spinal cord injury in animal models and humans. However, the physiological principles underlying the effect of this intervention remain poorly understood, which has limited the therapeutic approach to continuous stimulation applied to restricted spinal cord locations. Here we developed stimulation protocols that reproduce the natural dynamics of motoneuron activation during locomotion. For this, we computed the spatiotemporal activation pattern of muscle synergies during locomotion in healthy rats. Computer simulations identified optimal electrode locations to target each synergy through the recruitment of proprioceptive feedback circuits. This framework steered the design of spatially selective spinal implants and real-time control software that modulate extensor and flexor synergies with precise temporal resolution. Spatiotemporal neuromodulation therapies improved gait quality, weight-bearing capacity, endurance and skilled locomotion in several rodent models of spinal cord injury. These new concepts are directly translatable to strategies to improve motor control in humans.

Journal of NeuroEngineering and Rehabilitation · May 2013

In vitro and in vivo evaluation of a photosensitive polyimide thin-film microelectrode array suitable for epiretinal stimulation (opens in a new tab)

Xia Jiang, Xiaohong Sui, Yiliang Lu, … Xinyu Chai

Abstract

Background Epiretinal implants based on microelectro-mechanical system (MEMS) technology with a polyimide (PI) material are being proposed for application. Many kinds of non-photosensitive PIs have good biocompatibility and stability as typical MEMS materials for implantable electrodes. However, the effects of MEMS microfabrication, sterilization and implantation using a photosensitive polyimide (PSPI) microelectrode array for epiretinal electrical stimulation has not been extensively examined. Methods A novel PSPI (Durimide 7510) microelectrode array for epiretinal electrical stimulation was designed, fabricated based on MEMS processing and microfabrication techniques. The biocompatibility of our new microelectrode was tested in vitro using an MTT assay and direct contact tests between the microelectrode surface and cells. Electrochemical impedance characteristics were tested based on a three-electrode testing method. The reliability and stability was evaluated by a chronic implantation of a non-functional array within the rabbit eye. Histological examination and SEM were performed to monitor possible damage of the retina and microelectrodes. Electrically evoked potentials (EEPs) were recorded during the acute stimulation of the retina. Results The substrate was made of PSPI and the electrode material was platinum (Pt). The PSPI microelectrode array showed good biocompatibility and appropriate impedance characteristics for epiretinal stimulation. After a 6-month epiretinal implantation in the eyes of rabbits, we found no local retinal toxicity and no mechanical compression caused by the array. The Pt electrodes adhesion to the PSPI remained stable. A response to electrical stimuli was with recording electrodes lying on the visual cortex. Conclusion We provide a relevant design and fundamental characteristics of a PSPI microelectrode array. Strong evidences on testing indicate that implantation is safe in terms of mechanical pressure and biocompatibility of PSPI microelectrode arrays on the retina. The dual-layer process we used proffers considerable advantages over the more traditional single-layer approach and can accommodate much many electrode sites. This lays the groundwork for a future, high-resolution retinal prosthesis with many more electrode sites based on the flexible PSPI thin film substrate.