TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

The Laryngoscope · 2010

Hearing loss alters quantal release at cochlear nucleus stellate cells (opens in a new tab)

Rich AW, Xie R, Manis PB

Abstract

OBJECTIVES/HYPOTHESIS: Auditory nerve synapses in ventral cochlear nucleus end on two principal cell types, bushy and stellate cells. Although the effects of hearing loss on bushy cells have been well studied, little is known about the effects of hearing loss on synaptic input to the stellate cells. Based on prior observations in bushy cells, we hypothesized that noise-induced hearing loss (NIHL) would decrease quantal release onto stellate cells. STUDY DESIGN: Prospective, randomized animal study. METHODS: CBA/CaJ mice were exposed for 2 hours to 98 dB sound pressure level (SPL) 8- to 16-kHz noise to produce a temporary threshold shift (TTS) or 114 dB SPL to produce a permanent threshold shift (PTS). Spontaneous miniature excitatory postsynaptic currents (mEPSCs) were then measured in stellate cells in brain slices of the cochlear nucleus. RESULTS: Click auditory brainstem evoked response thresholds were elevated by 35 dB in both TTS and PTS mice. Spontaneous mEPSC frequency was found to be five-fold higher than normal in stellate cells of TTS mice and three-fold higher in PTS mice. The mEPSC amplitude was also larger in PTS mice. The mEPSC time course was not different between experimental and control groups. CONCLUSIONS: The dramatic increase in mEPSC frequency after NIHL was not expected. The increase in mEPSC amplitude in PTS mice suggests a postsynaptic remodeling process. Both of these effects could contribute to increased spontaneous firing in the cochlear nucleus in the absence of sound. Our results also suggest that hearing loss may have different effects at auditory nerve synapses on bushy and stellate cells in the VCN.

Otology & Neurotology · 2010

Intracochlear recordings of electrophysiological parameters indicating cochlear damage (opens in a new tab)

Adunka OF, Mlot S, Suberman TA, et al.

Abstract

OBJECTIVE: : The pathophysiologic mechanisms resulting in hearing loss during electrode implantation are largely unknown. To better understand the functional implications of electrode implantation, we recorded the effects of cochlear damage on acoustically evoked intracochlear measurements using normal-hearing gerbils. METHODS: : A metal electrode was placed on the surface of the round window, and recordings of the cochlear microphonic (CM) and compound action potential (CAP) were made in response to stimulation with tone-bursts at various frequencies in 1-octave intervals and at intensities of 15 to 72 dB sound pressure level. The electrode was then advanced incrementally, with CM and CAP measurements obtained at each step. These data were compared with data obtained at the round window, and the electrode was withdrawn when a significant change was observed. After electrophysiological analysis, the cochlea was examined histologically. RESULTS: : Results show that on electrode insertion, loss of amplitude in the CM and CAP occurs after damage to cochlear structures. Loss of activity was typically first apparent in the CAP rather than the CM. CONCLUSION: : These results suggest that a reduction of the CAP can be an early marker of interaction of the electrode with cochlear structures. Such measurements are potentially available with slight modifications to current cochlear implant technology.

Animal Behaviour · 2010

A mechanism for antiphonal echolocation by Free-tailed bats (opens in a new tab)

Jarvis J, Bohn KM, Tressler J, et al.

System 3OpenExAuditory Research
Abstract

Bats are highly social and spend much of their lives echolocating in the presence of other bats. To reduce the effects of acoustic interferences from other bats' echolocation calls, we hypothesized that bats might shift the timing of their pulse emissions to minimize temporal overlap with another bat's echolocation pulses. To test this hypothesis we investigated whether free-tailed bats (Tadarida brasiliensis) echolocating in the lab would shift the timing of their own pulse emissions in response to regularly repeating artificial acoustic stimuli. A robust phase-locked temporal pattern in pulse emissions was displayed by every bat tested which included an initial suppressive phase lasting more than 60 ms after stimulus onset, during which the probability of emitting pulses was reduced by more than fifty percent, followed by a compensatory rebound phase, the timing and amplitude of which were dependent on the temporal pattern of the stimulus. The responses were non-adapting and were largely insensitive to broad changes in the acoustic properties of the stimulus. Randomly occurring noise-bursts also suppressed calling for up to 60 ms, but the time-course of the compensatory rebound phase was more rapid than when the bats were responding to regularly repeating patterns of noise bursts. These findings provide the first quantitative description of how external stimuli may cause echolocating bats to alter the timing of subsequent pulse emissions.

IEEE Transactions on Biomedical Engineering · 2010

Quantifying time-varying multiunit neural activity using entropy based measures (opens in a new tab)

Choi YS, Koenig MA, Jia X, et al.

Abstract

Modern micro-electrode arrays make it possible to simultaneously record population neural activity. However, methods to analyze multiunit activity (MUA), which reflects the aggregate spiking activity of a population of neurons, have remained underdeveloped in comparison to those used for studying single unit activity (SUA). In scenarios where SUA is hard to record and maintain or is not representative of brains response, MUA is informative in deciphering the brains complex time-varying response to stimuli or to clinical insults. Here, we present two quantitative methods of analysis of the time-varying dynamics of MUA without spike detection. These methods are based on the multiresolution discrete wavelet transform (DWT) of an envelope of MUA followed by information theoretic measures: multiresolution entropy (MRE) and the multiresolution Kullback-Leibler distance (MRKLD). We test the proposed quantifiers on both simulated and experimental MUA recorded from rodent cortex in an experimental model of global hypoxic-ischemic brain injury. First, our results validate the use of the envelope of MUA as an alternative to detecting and analyzing transient and complex spike activity. Second, the MRE and MRKLD are shown to respond to dynamic changes due to the brains response to global injury and to identify the transient changes in the MUA.

Proceedings of the IEEE SoutheastCon · 2010

Design and characterization of an integrate-and-fire neural recording system (opens in a new tab)

Yen SF, Harris JG

Abstract

A neuronal recording system for brain-machine interfaces (BMI) based on asynchronous biphasic pulse coding is described. A recording experiment comparing, in parallel, a commercial recording system (Tucker-Davis Technology) and the UF's custom solution (FWIRE) is set up to compare performance. The novel aspect of the UF system is that the analog signal is represented by an asynchronous pulse train, which provides a low-power, low-bandwidth, noise-resistant means for coding and transmission. Based on different front-end hardware settings, recording bandwidth and corresponding reconstruction accuracy can be varied. Taking advantage of neural firing features, the pulse-based approach requires less than 3 K pulses/second to record a 25 KHz bandwidth signal from a hardware neural simulator. Recording performance has been characterized in the back-end signal processing with the spike sorting method. Two different spike sorting methods are proposed depending on different recording bandwidth constraints.

Neuroscience · 2010

Noise trauma impairs neurogenesis in the rat hippocampus (opens in a new tab)

Kraus KS, Mitra S, Jimenez Z, et al.

Abstract

The hippocampus, a major site of neurogenesis in the adult brain, plays an important role in memory. Based on earlier observations where exposure to high-intensity noise not only caused hearing loss but also impaired memory function, it is conceivably that noise exposure may suppress hippocampal neurogenesis. To evaluate this possibility, nine rats were unilaterally exposed for 2 h to a high-intensity, narrow band of noise centered at 12 kHz at 126 dB SPL. The rats were also screened for noise-induced tinnitus, a potential stressor which may suppress neurogenesis. Five rats developed persistent tinnitus-like behavior while the other four rats showed no signs of tinnitus. Age-matched sham controls showed no signs of hearing loss or tinnitus. The inner ear and hippocampus were evaluated for sensory hair cell loss and neurogenesis 10 weeks post-exposure. All noise exposed rats showed severe loss of sensory hair cells in the noise-exposed ear, but essentially no damage in the unexposed ear. Frontal sections from the hippocampus were immunolabeled for doublecortin to identify neuronal precursor cells, or Ki67 to label proliferating cells. Noise-exposed rats showed a significant reduction of neuronal precursors and fewer dividing cells as compared to sham controls. However, we could not detect any difference between rats with behavioral evidence of tinnitus versus rats without tinnitus. These results show for the first time that high intensity noise exposure not only damages the cochlea but also causes a significant and persistent decrease in hippocampal neurogenesis that may contribute to functional deficits in memory.

Hearing Research · 2010

Post exposure administration of A1 adenosine receptor agonists attenuates noise-induced hearing loss (opens in a new tab)

Ann Chi Yan Wong, Cindy X. Guo, Rita Gupta, … Srdjan M. Vlajkovic

Abstract

Adenosine is a constitutive cell metabolite with a putative role in protection and regeneration in many tissues. This study was undertaken to determine if adenosine signalling pathways are involved in protection against noise injury. A(1) adenosine receptor expression levels were altered in the cochlea exposed to loud sound, suggesting their involvement in the development of noise injury. Adenosine and selective adenosine receptor agonists (CCPA, CGS-21680 and Cl-IB-MECA) were applied to the round window membrane of the cochlea 6h after noise exposure. Auditory brainstem responses measured 48h after drug administration demonstrated partial recovery of hearing thresholds (up to 20dB) in the cochleae treated with adenosine (non-selective adenosine receptor agonist) or CCPA (selective A(1) adenosine receptor agonist). In contrast, the selective A(2A) adenosine receptor agonist CGS-21680 and A(3) adenosine receptor agonist Cl-IB-MECA did not protect the cochlea from hearing loss. Sound-evoked cochlear potentials in control rats exposed to ambient noise were minimally altered by local administration of the adenosine receptor agonists used in the noise study. Free radical generation in the cochlea exposed to noise was reduced by administration of adenosine and CCPA. This study pinpoints A(1) adenosine receptors as attractive targets for pharmacological interventions to reduce noise-induced cochlear injury after exposure.

Journal of the Association for Research in Otolaryngology · 2010

The effect of cochlear-implant-mediated electrical stimulation on spiral ganglion cells in congenitally deaf white cats (opens in a new tab)

Chen I, Limb CJ, Ryugo DK

Abstract

It has long been observed that loss of auditory receptor cells is associated with the progressive degeneration of spiral ganglion cells. Chronic electrical stimulation via cochlear implantation has been used in an attempt to slow the rate of degeneration in cats neonatally deafened by ototoxic agents but with mixed results. The present study examined this issue using white cats with a history of hereditary deafness as an alternative animal model. Nineteen cats provided new data for this study: four normal-hearing cats, seven congenitally deaf white cats, and eight congenitally deaf white cats with unilateral cochlear implants. Data from additional cats were collected from the literature. Electrical stimulation began at 3 to 4 or 6 to 7 months after birth, and cats received stimulation for approximately 7 h a day, 5 days a week for 12 weeks. Quantitative analysis of spiral ganglion cell counts, cell density, and cell body size showed no marked improvement between cochlear-implanted and congenitally deaf subjects. Average ganglion cell size from cochlear-implanted and congenitally deaf cats was statistically similar and smaller than that of normal-hearing cats. Cell density from cats with cochlear implants tended to decrease within the upper basal and middle cochlear turns in comparison to congenitally deaf cats but remained at congenitally deaf levels within the lower basal and apical cochlear turns. These results provide no evidence that chronic electrical stimulation enhances spiral ganglion cell survival, cell density, or cell size compared to that of unstimulated congenitally deaf cats. Regardless of ganglion neuron status, there is unambiguous restoration of auditory nerve synapses in the cochlear nucleus of these cats implanted at the earlier age.

IEEE Signal Processing Letters · 2010

Improving speech intelligibility in noise using a binary mask that is based on magnitude spectrum constraints (opens in a new tab)

Gibak Kim, Philipos C. Loizou

Abstract

A new binary mask is introduced for improving speech intelligibility based on magnitude spectrum constraints. The proposed binary mask is designed to retain time-frequency (T-F) units of the mixture signal satisfying a magnitude constraint while discarding T-F units violating the constraint. Motivated by prior intelligibility studies of speech synthesized using the ideal binary mask, an algorithm is proposed that decomposes the input signal into T-F units and makes binary decisions, based on a Bayesian classifier, as to whether each T-F unit satisfies the magnitude constraint or not. Speech corrupted at low signal-to-noise (SNR) levels (-5 and 0 dB) using different types of maskers is synthesized by this algorithm and presented to normal-hearing listeners for identification. Results indicated substantial improvements in intelligibility over that attained by human listeners with unprocessed stimuli.

Otology & Neurotology · 2010

Correlation of early auditory potentials and intracochlear electrode insertion properties: an animal model featuring near real-time monitoring (opens in a new tab)

Campbell AP, Suberman TA, Buchman CA, et al.

Abstract

OBJECTIVE: The goal of this work was to assess electrophysiologic response changes to acoustic stimuli as an intracochlear electrode impacted cochlear structures in an animal model of hearing preservation cochlear implantation. The ultimate goal is to develop efficient procedures for assessing the status of cochlear physiology for intraoperative use. METHODS: Sixteen gerbils and 18 ears were tested. A rigid electrode was inserted through a basal turn cochleostomy and directed toward the basilar membrane/osseous spiral lamina complex. We recorded acoustically evoked early auditory potentials including cochlear microphonics (CMs) and compound action potentials (CAPs) to a short stimulation sequence consisting of one stimulus frequency and intensity as the electrode was advanced. A microendoscope was used to visualize the electrode insertion progress and to identify the site of electrode impact. After each experiment, the site of intracochlear trauma was confirmed using whole mount preparations. RESULTS: Electrophysiologic changes correlated well with the degree and location of trauma. We observed four distinct patterns. In addition, the endoscope in conjunction with the short recording sequence allowed for the detection of response changes that were reversible when the electrode was retracted. These cases were associated with less than full-thickness damage on histology. CONCLUSION: The short recording sequence to obtain acoustically evoked intracochlear potentials and the microendoscope allowed us to detect various levels of cochlear trauma including minor and reversible damage. Recordings of this type are potentially available using current implant technology. Future improvements in the measurements can be expected to improve the efficiency of the recording paradigm to produce a clinically useful tool.