Experimental Brain Research · Jun 2011
Denise C. P. B. M. Van Barneveld, Tom J. Van Grootel, Bart Alberts, A. John Van Opstal
Abstract
We studied the influence of static head roll on the perceived auditory zenith in head-centred and world-centred coordinates. Subjects sat either upright, or with their head left/right rolled sideways by about 35° relative to gravity, whilst judging whether a broadband sound was heard left or right from the head-centred or world-centred zenith. When upright, these reference frames coincide. Results show that subjects judged the zenith accurately within different planes, although response variability increased for the midsagittal plane. With the head rolled, head-centred auditory zenith shifted by the same amount and was located as accurately as for upright, indicating unaltered localisation cues by head-on-body roll. Interestingly, when judging world-centred zenith subjects made large systematic errors (10-15°) in the direction of head roll, and response variability increased, which resembles the visual Aubert effect. These results demonstrate a significant influence of the vestibular-collic system on auditory spatial awareness, which sheds new light on the mechanisms underlying multisensory integration and spatial updating in sound localisation behaviour.
Hearing Research · Jun 2011
Westen AA, Dekker DM, Briaire JJ, Frijns JH
Abstract
The common assumption that the electrically evoked compound action potential (eCAP) has a linear relationship with the number of excited nerve fibres is derived from the acoustical unitary response concept. This study tests the validity of this hypothesis for electrical stimulation. Five guinea pigs were implanted with the tip of a human HiFocus electrode. eCAPs were measured with the forward masking paradigm, using anodic- and cathodic-leading biphasic current pulses and the inter-pulse interval was varied. Masker and probe amplitudes were varied either individually or simultaneously. Surprisingly, at high levels decreasing eCAP amplitudes were measured with increasing stimulus current. In search for an explanation, the experimental conditions were implemented in our 3D computational model of the implanted guinea pig cochlea to perform a functional comparison. In the final experiment, with fixed inter-pulse interval (IPI) and anodic-leading pulses, increasing stimulus currents showed growing numbers of excited nerve fibres and decreasing eCAP amplitudes at high levels, again. While simulating the relative contribution of single fibres to the overall eCAP, an explanation for this could be found in a waveform change in the modelled single fibre action potentials at high levels. We conclude that highly stimulated nerve fibres have another contribution to the eCAP response than lower stimulated fibres, which leads to a reduction of the eCAP amplitude at high levels.
The Journal of the Acoustical Society of America · Jun 2011
Desloge JG, Reed CM, Braida LD, et al.
Abstract
A functional simulation of hearing loss was evaluated in its ability to reproduce the temporal modulation transfer functions (TMTFs) for nine listeners with mild to profound sensorineural hearing loss. Each hearing loss was simulated in a group of three age-matched normal-hearing listeners through spectrally shaped masking noise or a combination of masking noise and multiband expansion. TMTFs were measured for both groups of listeners using a broadband noise carrier as a function of modulation rate in the range 2 to 1024 Hz. The TMTFs were fit with a lowpass filter function that provided estimates of overall modulation-depth sensitivity and modulation cutoff frequency. Although the simulations were capable of accurately reproducing the threshold elevations of the hearing-impaired listeners, they were not successful in reproducing the TMTFs. On average, the simulations resulted in lower sensitivity and higher cutoff frequency than were observed in the TMTFs of the hearing-impaired listeners. Discrepancies in performance between listeners with real and simulated hearing loss are possibly related to inaccuracies in the simulation of recruitment.
Journal of Neural Engineering · Jun 2011
Rouse AG, Stanslaski SR, Cong P, et al.
Abstract
A bi-directional neural interface (NI) system was designed and prototyped by incorporating a novel neural recording and processing subsystem into a commercial neural stimulator architecture. The NI system prototype leverages the system infrastructure from an existing neurostimulator to ensure reliable operation in a chronic implantation environment. In addition to providing predicate therapy capabilities, the device adds key elements to facilitate chronic research, such as four channels of electrocortigram/local field potential amplification and spectral analysis, a three-axis accelerometer, algorithm processing, event-based data logging, and wireless telemetry for data uploads and algorithm/configuration updates. The custom-integrated micropower sensor and interface circuits facilitate extended operation in a power-limited device. The prototype underwent significant verification testing to ensure reliability, and meets the requirements for a class CF instrument per IEC-60601 protocols. The ability of the device system to process and aid in classifying brain states was preclinically validated using an in vivo non-human primate model for brain control of a computer cursor (i.e. brain-machine interface or BMI). The primate BMI model was chosen for its ability to quantitatively measure signal decoding performance from brain activity that is similar in both amplitude and spectral content to other biomarkers used to detect disease states (e.g. Parkinson's disease). A key goal of this research prototype is to help broaden the clinical scope and acceptance of NI techniques, particularly real-time brain state detection. These techniques have the potential to be generalized beyond motor prosthesis, and are being explored for unmet needs in other neurological conditions such as movement disorders, stroke and epilepsy.
Hearing Research · Jun 2011
Crawley BK, Keithley EM
Abstract
Age-related hearing loss is a multi-factorial process involving genetic and environmental factors, including exposure to noise and ototoxic agents, as well as pathological processes. Among these is the accumulation of mitochondrial DNA mutations and deletions. The creation of a transgenic mouse with a loss-of-function deletion of the nuclear gene that encodes the polymerase required to repair damaged mitochondrial DNA (PolgA) enabled evaluation of age-related cochlear pathology associated with random mitochondrial DNA deletions that accrue over the lifespan of the mouse. In comparison with their wild-type or heterozygous counterparts, animals with mutated DNA polymerase gamma developed hearing loss most rapidly. Any loss of mitochondrial DNA polymerase function however, resulted in detrimental effects, as evidenced by hearing tests and histological investigation of transgenic heterozygotes. Cochlear pathology in transgenic animals at 10 months of age included loss of neurons and clumping of surviving neurons in the apical turn of the spiral ganglion. Mitochondrial mutations in young animals, on the other hand, were protective against the development of temporary threshold shift in response to relatively low level noise exposure. This supports the idea that temporary threshold shifts are the result of an active process involving mitochondria and respiratory chain activity. Our results indicate that mitochondrial mutation and deletion can certainly contribute to the development of an aging phenotype, specifically age-related hearing loss.
The Journal of the Acoustical Society of America · Jun 2011
Martin RL, Flanagan P, McAnally KI, Eberle G
Abstract
The accuracy with which a single source of sound can be localized has been examined in many studies, but very few studies have examined the ability of participants to determine the absolute locations of multiple sources of sound. The current study assessed participants' abilities to determine and remember the locations of up to six sources of environmental sound that were positioned at a range of azimuths and elevations in virtual auditory space. In experiment 1, a sequence of one to six sounds was presented one, three, or five times in each trial and the target sound was nominated following presentation of the last sequence. In experiment 2, memory load was held constant by nominating the target sound prior to a single sequence presentation. Localization accuracy was observed to decrease as the number of sounds was increased to three or more under the conditions of experiment 1, but not those of experiment 2. In experiment 1, localization was more accurate when sequences were presented more than once. Pronounced primacy and recency effects were observed for the six sound conditions in experiment 1. An analysis of errors for those conditions indicated that immediate temporal errors, but not immediate spatial errors, were over-represented.
Acta Physica Polonica A · Jun 2011
J. Kociński, A. Sęk, P. Libiszewski
Abstract
Blind signal separation is one of the latest methods to improve the signal to noise ratio.The main objective of blind source separation is the transformation of mixtures of recorded signals to obtain each source signal at the output of the procedure, assuming that they are statistically independent.For acoustic signals it can be concluded that the correct separation is possible only if the source signals are spatially separated.That finding suggests analogies with the classical spatial filtering (beamforming).In this study we analyzed an effect of the angular separation of two source signals (i.e.speech and babble noise) to improve speech intelligibility.For this purpose, we chose the blind source separation algorithm based on the convolutive separation, based on second order statistics only.As a system of sensors a dummy head was used (one microphone inside each ear canal), which simulated two hearing aids of a hearing impaired person.The speech reception threshold, before and after the blind source separation was determined.The results have shown significant improvement in speech intelligibility after applying blind source separation (speach reception threshold fell even more than a dozen dB) in cases where the source signals were angularly separated.However, in cases where the source signals were coming from the same directions, the improvement was not observed.Moreover, the effectiveness of the blind source separation, to a large extent, depended on the relative positions of signal sources in space.
Brain and Language · Jun 2011
A. Flinker, E.F. Chang, N.M. Barbaro, … R.T. Knight
Abstract
The human temporal lobe is well known to be critical for language comprehension. Previous physiological research has focused mainly on non-invasive neuroimaging and electrophysiological techniques with each approach requiring averaging across many trials and subjects. The results of these studies have implicated extended anatomical regions in peri-sylvian cortex in speech perception. These non-invasive studies typically report a spatially homogenous functional pattern of activity across several centimeters of cortex. We examined the spatiotemporal dynamics of word processing using electrophysiological signals acquired from high-density electrode arrays (4mm spacing) placed directly on the human temporal lobe. Electrocorticographic (ECoG) activity revealed a rich mosaic of language activity, which was functionally distinct at four mm separation. Cortical sites responding specifically to word and not phoneme stimuli were surrounded by sites that responded to both words and phonemes. Other sub-regions of the temporal lobe responded robustly to self-produced speech and minimally to external stimuli while surrounding sites at 4mm distance exhibited an inverse pattern of activation. These data provide evidence for temporal lobe specificity to words as well as self-produced speech. Furthermore, the results provide evidence that cortical processing in the temporal lobe is not spatially homogenous over centimeters of cortex. Rather, language processing is supported by independent and spatially distinct functional sub-regions of cortex at a resolution of at least 4mm.
Journal of Neurophysiology · Jun 2011
Joji Tsunada, Jung Hoon Lee, Yale E. Cohen
Abstract
A “ventral” auditory pathway in nonhuman primates that originates in the core auditory cortex and ends in the prefrontal cortex is thought to be involved in components of nonspatial auditory processing. Previous work from our laboratory has indicated that neurons in the prefrontal cortex reflect monkeys' decisions during categorical judgments. Here, we tested the role of the superior temporal gyrus (STG), a region of the secondary auditory cortex that is part of this ventral pathway, during similar categorical judgments. While monkeys participated in a match-to-category task and reported whether two consecutive auditory stimuli belonged to the same category or to different categories, we recorded spiking activity from STG neurons. The auditory stimuli were morphs of two human-speech sounds ( bad and dad). We found that STG neurons represented auditory categories. However, unlike activity in the prefrontal cortex, STG activity was not modulated by the monkeys' behavioral reports (choices). This finding is consistent with the anterolateral STG's role as a part of functional circuit involved in the coding, representation, and perception of the nonspatial features of an auditory stimulus.
NeuroImage · Jun 2011
Xin Yu, Brian J. Nieman, Anamaria Sudarov, … Daniel H. Turnbull
Abstract
With increasing efforts to develop and utilize mouse models of a variety of neuro-developmental diseases, there is an urgent need for sensitive neuroimaging methods that enable in vivo analysis of subtle alterations in brain anatomy and function in mice. Previous studies have shown that the brains of Fibroblast Growth Factor 17 null mutants (Fgf17(-/-)) have anatomical abnormalities in the inferior colliculus (IC)-the auditory midbrain-and minor foliation defects in the cerebellum. In addition, changes in the expression domains of several cortical patterning genes were detected, without overt changes in forebrain morphology. Recently, it has also been reported that Fgf17(-/-) mutants have abnormal vocalization and social behaviors, phenotypes that could reflect molecular changes in the cortex and/or altered auditory processing / perception in these mice. We used manganese (Mn)-enhanced magnetic resonance imaging (MEMRI) to analyze the anatomical phenotype of Fgf17(-/-) mutants in more detail than achieved previously, detecting changes in IC, cerebellum, olfactory bulb, hypothalamus and frontal cortex. We also used MEMRI to characterize sound-evoked activity patterns, demonstrating a significant reduction of the active IC volume in Fgf17(-/-) mice. Furthermore, tone-specific (16- and 40-kHz) activity patterns in the IC of Fgf17(-/-) mice were observed to be largely overlapping, in contrast to the normal pattern, separated along the dorsal-ventral axis. These results demonstrate that Fgf17 plays important roles in both the anatomical and functional development of the auditory midbrain, and show the utility of MEMRI for in vivo analyses of mutant mice with subtle brain defects.
Journal of Neurophysiology · Jun 2011
Edward L. Bartlett, Xiaoqin Wang
Abstract
As the information bottleneck of nearly all auditory input that reaches the cortex, the auditory thalamus serves as the basis for establishing auditory cortical processing streams. The functional organization of the primary and nonprimary subdivisions of the auditory thalamus is not well characterized, particularly in awake primates. We have recorded from neurons in the auditory thalamus of awake marmoset monkeys and tested their responses to tones, band-pass noise, and temporally modulated stimuli. We analyzed the spectral and temporal response properties of recorded neurons and correlated those properties with their locations in the auditory thalamus, thereby forming the basis for parallel output channels. Three medial geniculate body (MGB) subdivisions were identified and studied physiologically and anatomically, although other medial subdivisions were also identified anatomically. Neurons in the ventral subdivision (MGV) were sharply tuned for frequency, preferred narrowband stimuli, and were able to synchronize to rapid temporal modulations. Anterodorsal subdivision (MGAD) neurons appeared well suited for temporal processing, responding similarly to tone or noise stimuli but able to synchronize to the highest modulation frequencies and with the highest temporal precision among MGB subdivisions. Posterodorsal subdivision (MGPD) neurons differed substantially from the other two subdivisions, with many neurons preferring broadband stimuli and signaling changes in modulation frequency with nonsynchronized changes in firing rate. Most neurons in all subdivisions responded to increases in tone sound level with nonmonotonic changes in firing rate. MGV and MGAD neurons exhibited responses consistent with provision of thalamocortical input to core regions, whereas MGPD neurons were consistent with provision of input to belt regions.
Neuroscience · Jun 2011
D.L. Oliver, M.A. Izquierdo, M.S. Malmierca
Abstract
Acoustic experiences significantly shape the functional organization of the auditory cortex during postnatal "critical periods." Here, we investigate the effects of a non-traumatic augmented acoustic environment (AAE) on the central nucleus of the inferior colliculus (ICC) and lower brainstem nuclei in rat during the critical period. Our results show that an AAE during P9-P28 had a persistent effect on the evoked auditory brainstem responses leading to a decreased latency and an increased amplitude of the response at and above the frequency of the stimulus used for the AAE. These findings are correlated with increased numbers of sites in the ICC that responded to the AAE frequency and show higher thresholds. There also were persistent effects in neurons with a best frequency higher than the AAE stimulus. These neurons showed decreased activity at low sound levels in the low frequency tail of the frequency response area. This was at, below and above the AAE stimulus frequency. Less often, increased activity at higher sound levels also was seen. Together, these findings suggest multifaceted interactions between activity-dependent plasticity, homeostasis, and development in the brainstem during the initial stages of hearing. A neonate exposed to an altered auditory environment may experience long-lasting change over the entire network of the auditory system.
Journal of Experimental Biology · Jun 2011
Jason S. Schwarz, Tobias Reichenbach, A. J. Hudspeth
Abstract
The perception of sensory stimuli by an animal requires several steps, commencing with the capture of stimulus energy by an antenna that, as the interface between the physical world and the nervous system, modifies the stimulus in ways that enhance the animal's perception. The mammalian external ear, for example, collects sound and spectrally alters it to increase sensitivity and improve the detection of directionality. In view of the morphological diversity of the lateral-line system across species and its accessibility to observation and experimental intervention, we sought to investigate the role of antennal structures on the response characteristics of the lateral line. The surface-feeding killifish Aplocheilus lineatus is able to hunt in darkness by detecting surface capillary waves with the lateral-line system atop its head. This cephalic lateral line consists of a stereotyped array of 18 mechanosensitive neuromasts bordered by fleshy ridges. By recording microphonic potentials, we found that each neuromast has a unique receptive field defined by its sensitivity to stimulation of the water's surface. The ridges help determine these receptive fields by altering the flow of water over each neuromast. Modification of the hydrodynamic environment by the addition of a supplemental ridge changes the pattern of water movement, perturbs the receptive fields of adjacent neuromasts and impairs the fish's localization ability. On the basis of electrophysiological, hydrodynamic and behavioral evidence, we propose that the ridges constitute a hydrodynamic antenna for the cephalic lateral line.
Neuron · Jun 2011
Neil C. Rabinowitz, Ben D.B. Willmore, Jan W.H. Schnupp, Andrew J. King
Abstract
The auditory system must represent sounds with a wide range of statistical properties. One important property is the spectrotemporal contrast in the acoustic environment: the variation in sound pressure in each frequency band, relative to the mean pressure. We show that neurons in ferret auditory cortex rescale their gain to partially compensate for the spectrotemporal contrast of recent stimulation. When contrast is low, neurons increase their gain, becoming more sensitive to small changes in the stimulus, although the effectiveness of contrast gain control is reduced at low mean levels. Gain is primarily determined by contrast near each neuron's preferred frequency, but there is also a contribution from contrast in more distant frequency bands. Neural responses are modulated by contrast over timescales of ∼100 ms. By using contrast gain control to expand or compress the representation of its inputs, the auditory system may be seeking an efficient coding of natural sounds.
The Journal of the Acoustical Society of America · Jun 2011
Isabelle C. Noirot, Elizabeth F. Brittan-Powell, Robert J. Dooling
Abstract
Auditory brainstem responses (ABRs) were recorded in adult budgerigars, canaries, and zebra finches in quiet and in three levels of white noise for tone stimuli between 1 and 4 kHz. Similar to behavioral results, masked ABR thresholds increased linearly with increasing noise levels. When the three species are considered together, ABR-derived CRs were higher than behavioral CRs by 18–23 dB between 2 and 4 kHz and by about 30 dB at 1 kHz. This study clarifies the utility of using ABRs for estimating masked auditory thresholds in natural environmental noises in species that cannot be tested behaviorally.
Audiology & Neuro-otology · May 2011
Bremer HG, de Groot JC, Versnel H, Klis SF
Abstract
Aminoglycoside antibiotics are known to damage the vestibular and auditory sensory epithelia. Although loop diuretics enhance the cochleotoxic effect of aminoglycosides, it is not known whether concomitant administration of an aminoglycoside and a loop diuretic affects the vestibular system. The aim of our study was to investigate the effect of co-administration of kanamycin and furosemide upon the otolith organs and to compare it to the known vestibulotoxic effect of gentamicin. Five guinea pigs were injected with a single dose of both kanamycin (400 mg/kg, s.c.) and furosemide (100 mg/kg, i.v.), 5 animals received gentamicin (100 mg/kg, i.p.) for 10 days, and 5 untreated animals served as controls. After 7 days, vestibular function was assessed by measuring vestibular short-latency evoked potentials (VsEPs) to linear acceleration stimuli and cochlear function by auditory brainstem responses (ABRs) to clicks. Hair cell densities were determined in phalloidin-stained whole mounts of the utricles and saccules, and in midmodiolar sections of resin-embedded cochleae. Co-administration of kanamycin and furosemide had no significant effect on VsEPs and hair cell densities in the utricles and saccules were not reduced. ABR thresholds were increased to a great extent (by ∼60 dB), and histologically a severe loss of cochlear hair cells was observed. The effect of gentamicin, both on vestibular and cochlear function, was just the opposite. VsEP thresholds to horizontal stimulation were elevated and suprathreshold amplitudes showed a decrease, whereas cochlear function was not reduced. With this protocol, we have a tool to selectively induce cochlear or vestibular damage, which may be of interest to researchers and clinicians alike.
Journal of Neural Engineering · May 2011
P T McCarthy, M P Rao, K J Otto
Abstract
Direct recording from sequential processing stations within the brain has provided opportunity for enhancing understanding of important neural circuits, such as the corticothalamic loops underlying auditory, visual, and somatosensory processing. However, the common reliance upon microwire-based electrodes to perform such recordings often necessitates complex surgeries and increases trauma to neural tissues. This paper reports the development of titanium-based, microfabricated, microelectrode devices designed to address these limitations by allowing acute recording from the thalamic nuclei and associated cortical sites simultaneously in a minimally invasive manner. In particular, devices were designed to simultaneously probe rat auditory cortex and auditory thalamus, with the intent of recording auditory response latencies and isolated action potentials within the separate anatomical sites. Details regarding the design, fabrication, and characterization of these devices are presented, as are preliminary results from acute in vivo recording.
Journal of Neural Engineering · May 2011
A Muralidharan, J Chae, D M Taylor
Abstract
Movement-assist devices such as neuromuscular stimulation systems can be used to generate movements in people with chronic hand paralysis due to stroke. If detectable, motor planning activity in the cortex could be used in real time to trigger a movement-assist device and restore a person's ability to perform many of the activities of daily living. Additionally, re-coupling motor planning in the cortex with assisted movement generation in the periphery may provide an even greater benefit-strengthening relevant synaptic connections over time to promote natural motor recovery. This study examined the potential for using electroencephalograms (EEGs) as a means of rapidly detecting the intent to open the hand during movement planning in individuals with moderate chronic hand paralysis following a subcortical ischemic stroke. On average, attempts to open the hand could be detected from EEGs approximately 100-500 ms prior to the first signs of movement onset. This earlier detection would minimize device activation delays and allow for tighter coupling between initial formation of the motor plan in the cortex and augmentation of that plan in the periphery by a movement-assist device. This tight temporal coupling may be important or even essential for strengthening synaptic connections and enhancing natural motor recovery.
Neuroscience · May 2011
Nichols JA, Nichols AR, Smirnakis SM, … Atzori M
Abstract
Vagus nerve stimulation (VNS) is an FDA approved treatment for drug-resistant epilepsy and depression. Recently, we demonstrated the capacity for repeatedly pairing sensory input with brief pulses of VNS to induce input specific reorganization in rat auditory cortex. This was subsequently used to reverse the pathological neural and perceptual correlates of hearing loss induced tinnitus. Despite its therapeutic potential, VNS mechanisms of action remain speculative. In this study, we report the acute effects of VNS on intra-cortical synchrony, excitability, and sensory processing in anesthetized rat auditory cortex. VNS significantly increased and decorrelated spontaneous multi-unit activity, and suppressed entrainment to repetitive noise burst stimulation at 6-8 Hz but not after application of the muscarinic antagonist scopolamine. Collectively, these experiments demonstrate the capacity for VNS to acutely influence cortical synchrony and excitability and strengthen the hypothesis that acetylcholine and muscarinic receptors are involved in VNS mechanisms of action. These results are discussed with respect to their possible implications for sensory processing, neural plasticity, and epilepsy.
Journal of Neurophysiology · May 2011
Zhu H, Tang X, Wei W, … Zhou W
Abstract
Sound activates not only the cochlea but also the vestibular end organs. Research on this phenomenon led to the discovery of the sound-evoked vestibular myogenic potentials recorded from the sternocleidomastoid muscles (cervical VEMP, or cVEMP). Since the cVEMP offers simplicity and the ability to stimulate each labyrinth separately, its values as a test of human vestibular function are widely recognized. Currently, the cVEMP is interpreted as a test of saccule function based on the assumption that clicks primarily activate the saccule. However, sound activation of vestibular end organs other than the saccule has been reported. To provide the neural basis for interpreting clinical VEMP testing, we employed the broadband clicks used in clinical VEMP testing to examine the sound-evoked responses in a large sample of vestibular afferents in Sprague-Dawley rats. Recordings were made from 924 vestibular afferents from 106 rats: 255 from the anterior canal (AC), 202 from the horizontal canal (HC), 177 from the posterior canal (PC), 207 from the superior vestibular nerve otolith (SO), and 83 from the inferior nerve otolith (IO). Sound sensitivity of each afferent was quantified by computing the cumulative probability of evoking a spike (CPE). We found that clicks activated irregular afferents (normalized coefficient of variation of interspike intervals >0.2) from both the otoliths (81%) and the canals (43%). The order of end organ sound sensitivity was SO = IO > AC > HC > PC. Since the sternocleidomastoid motoneurons receive inputs from both the otoliths and the canals, these results provide evidence of a possible contribution from both of them to the click-evoked cVEMP.