The Journal of the Acoustical Society of America · Oct 2012
William P. Shofner, Jeannine Campbell
Abstract
To study the role of harmonic structure in pitch perception, normal-hearing listeners were tested using noise-vocoded harmonic tone complexes. When tested in a magnitude judgment procedure using vocoded versions generated with 2–128 channels, judgments of pitch strength increased systematically as the number of channels increased and reflected acoustic cues based on harmonic peak-to-valley ratio, but not cues based on periodicity strength. When tested in a fundamental frequency discrimination task, listeners correctly recognized the direction of pitch change with as few as eight noise-vocoded channels. The results suggest that spectral processing contributes substantially to pitch perception in normal-hearing listeners.
Journal of Neurophysiology · Oct 2012
de Cheveigné A, Edeline JM, Gaucher Q, Gourévitch B
Abstract
Local field potentials (LFPs) recorded in the auditory cortex of mammals are known to reveal weakly selective and often multimodal spectrotemporal receptive fields in contrast to spiking activity. This may in part reflect the wider "listening sphere" of LFPs relative to spikes due to the greater current spread at low than high frequencies. We recorded LFPs and spikes from auditory cortex of guinea pigs using 16-channel electrode arrays. LFPs were processed by a component analysis technique that produces optimally tuned linear combinations of electrode signals. Linear combinations of LFPs were found to have sharply tuned responses, closer to spike-related tuning. The existence of a sharply tuned component implies that a cortical neuron (or group of neurons) capable of forming a linear combination of its inputs has access to that information. Linear combinations of signals from electrode arrays reveal information latent in the subspace spanned by multichannel LFP recordings and are justified by the fact that the observations themselves are linear combinations of neural sources.
PLOS ONE · Oct 2012
Yan-Yan Su, Bin Luo, Yan Jin, … Lin Chen
Abstract
Sodium salicylate (NaSal), an aspirin metabolite, can cause tinnitus in animals and human subjects. To explore neural mechanisms underlying salicylate-induced tinnitus, we examined effects of NaSal on neural activities of the medial geniculate body (MGB), an auditory thalamic nucleus that provides the primary and immediate inputs to the auditory cortex, by using the whole-cell patch-clamp recording technique in MGB slices. Rats treated with NaSal (350 mg/kg) showed tinnitus-like behavior as revealed by the gap prepulse inhibition of acoustic startle (GPIAS) paradigm. NaSal (1.4 mM) decreased the membrane input resistance, hyperpolarized the resting membrane potential, suppressed current-evoked firing, changed the action potential, and depressed rebound depolarization in MGB neurons. NaSal also reduced the excitatory and inhibitory postsynaptic response in the MGB evoked by stimulating the brachium of the inferior colliculus. Our results demonstrate that NaSal alters neuronal intrinsic properties and reduces the synaptic transmission of the MGB, which may cause abnormal thalamic outputs to the auditory cortex and contribute to NaSal-induced tinnitus.
The Journal of the Acoustical Society of America · Oct 2012
Ross K. Maddox, Willy Cheung, Adrian K. C. Lee
Abstract
Listeners are good at attending to one auditory stream in a crowded environment. However, is there an upper limit of streams present in an auditory scene at which this selective attention breaks down? Here, participants were asked to attend one stream of spoken letters amidst other letter streams. In half of the trials, an initial primer was played, cueing subjects to the sound configuration. Results indicate that performance increases with token repetitions. Priming provided a performance benefit, suggesting that stream selection, not formation, is the bottleneck associated with attention in an overcrowded scene. Results' implications for brain-computer interfaces are discussed.
International Journal of Pediatric Otorhinolaryngology · Oct 2012
Jang CH, Cho YB, Choi CH, … Kang SI
Abstract
Objective No study to date has assessed the anti-adhesive effect of new middle ear (ME) packing agents in. This study compared the anti-inflammatory and anti-adhesive effect of antibiotic-steroid containing packing agents in abraded mucosa of the ME inflammation. Materials and methods Transbullar injection of a saline suspension of Pseudomonas aeruginosa lipopolysaccharide (LPS) induced otitis media. ME mucosa of guinea pigs was abraded using a pick 30 min after LPS inoculation. The animals were divided into four groups of 10 guinea pigs each. In group A, ME cavity was preserved without any packing. In group B, ME cavity was packed with soluble hyaluronic acid-carboxymethyl cellulose (HA-CMC). In group C, the ME cavity was packed with soluble HA-CMC. In group D, the ME cavity was packed with antibiotic-steroid containing soluble HA-CMC. Otoendoscopic examination, auditory brainstem responses (ABRs), and radiographic examination using computerized tomography (CT) were performed at 2 weeks post-surgery. Histopathological evaluation for ME mucosa was performed by light microscopy (LM) and scanning electron microscopy (SEM). Results Otoendoscopic findings and CT findings revealed that group D showed the best recovery of aeration in the ME compared to other groups. Recovery of ABRs threshold was significantly attenuated in group D. In LM and SEM findings, group D showed normalized mucosal thickening compared to other groups. Conclusion ME packing by antibiotic-steroid containing soluble HA-CMC may be useful in the abraded mucosa of the ME inflammation.
NeuroImage · Oct 2012
Zhang JW, Lau C, Cheng JS, … Wu EX
Abstract
Intensity is an important physical property of a sound wave and is customarily reported as sound pressure level (SPL). Invasive techniques such as electrical recordings, which typically examine one brain region at a time, have been used to study neuronal encoding of SPL throughout the central auditory system. Non-invasive functional magnetic resonance imaging (fMRI) with large field of view can simultaneously examine multiple auditory structures. We applied fMRI to measure the hemodynamic responses in the rat brain during sound stimulation at seven SPLs over a 72 dB range. This study used a sparse temporal sampling paradigm to reduce the adverse effects of scanner noise. Hemodynamic responses were measured from the central nucleus of the inferior colliculus (CIC), external cortex of the inferior colliculus (ECIC), lateral lemniscus (LL), medial geniculate body (MGB), and auditory cortex (AC). BOLD signal changes generally increase significantly (p<0.001) with SPL and the dependence is monotonic in CIC, ECIC, and LL. The ECIC has higher BOLD signal change than CIC and LL at high SPLs. The difference between BOLD signal changes at high and low SPLs is less in the MGB and AC. This suggests that the SPL dependences of the LL and IC are different from those in the MGB and AC and the SPL dependence of the CIC is different from that of the ECIC. These observations are likely related to earlier observations that neurons with firing rates that increase monotonically with SPL are dominant in the CIC, ECIC, and LL while non-monotonic neurons are dominant in the MGB and AC. Further, the IC's SPL dependence measured in this study is very similar to that measured in our earlier study using the continuous imaging method. Therefore, sparse temporal sampling may not be a prerequisite in auditory fMRI studies of the IC.
The Journal of Neuroscience · Oct 2012
Dajun Xing, Yutai Shen, Samuel Burns, … Wu Li
Abstract
Oscillatory neural activity within the gamma band (25–90 Hz) is generally thought to be able to provide a timing signal for harmonizing neural computations across different brain regions. Using time–frequency analyses of the dynamics of gamma-band activity in the local field potentials recorded from monkey primary visual cortex, we found identical temporal characteristics of gamma activity in both awake and anesthetized brain states, including large variability of peak frequency, brief oscillatory epochs (<100 ms on average), and stochastic statistics of the incidence and duration of oscillatory events. These findings indicate that gamma-band activity is temporally unstructured and is inherently a stochastic signal generated by neural networks. This idea was corroborated further by our neural-network simulations. Our results suggest that gamma-band activity is too random to serve as a clock signal for synchronizing neuronal responses in awake as in anesthetized monkeys. Instead, gamma-band activity is more likely to be filtered neuronal network noise. Its mean frequency changes with global state and is reduced under anesthesia.
Cognitive Neurodynamics · Oct 2012
Yoshinori Ide, Muneyoshi Takahashi, Johan Lauwereyns, … Takeshi Aihara
Abstract
The present study used an optical imaging paradigm to investigate plastic changes in the auditory cortex induced by fear conditioning, in which a sound (conditioned stimulus, CS) was paired with an electric foot-shock (unconditioned stimulus, US). We report that, after conditioning, auditory information could be retrieved on the basis of an electric foot-shock alone. Before conditioning, the auditory cortex showed no response to a foot-shock presented in the absence of sound. In contrast, after conditioning, the mere presentation of a foot-shock without any sound succeeded in eliciting activity in the auditory cortex. Additionally, the magnitude of the optical response in the auditory cortex correlated with variation in the electrocardiogram (correlation coefficient: -0.68). The area activated in the auditory cortex, in response to the electric foot-shock, statistically significantly had a larger cross-correlation value for tone response to the CS sound (12 kHz) compared to the non-CS sounds in normal conditioning group. These results suggest that integration of different sensory modalities in the auditory cortex was established by fear conditioning.
Journal of Neurophysiology · Oct 2012
Maier JK, Hehrmann P, Harper NS, et al.
Abstract
Many neurons adapt their spike output to accommodate the prevailing sensory environment. Although such adaptation is thought to improve coding of relevant stimulus features, the relationship between adaptation at the neural and behavioral levels remains to be established. Here we describe improved discrimination performance for an auditory spatial cue (interaural time differences, ITDs) following adaptation to stimulus statistics. Physiological recordings in the midbrain of anesthetized guinea pigs and measurement of discrimination performance in humans both demonstrate improved coding of the most prevalent ITDs in a distribution, but with highest accuracy maintained for ITDs corresponding to frontal locations, suggesting the existence of a fovea for auditory space. A biologically plausible model accounting for the physiological data suggests that neural tuning is stabilized by inhibition to maintain high discriminability for frontal locations. The data support the notion that adaptive coding in the midbrain is a key element of behaviorally efficient sound localization in dynamic acoustic environments.
The Journal of the Acoustical Society of America · Oct 2012
Freyman RL, Griffin AM, Oxenham AJ
Abstract
This study investigated the role of natural periodic temporal fine structure in helping listeners take advantage of temporal valleys in amplitude-modulated masking noise when listening to speech. Young normal-hearing participants listened to natural, whispered, and/or vocoded nonsense sentences in a variety of masking conditions. Whispering alters normal waveform temporal fine structure dramatically but, unlike vocoding, does not degrade spectral details created by vocal tract resonances. The improvement in intelligibility, or masking release, due to introducing 16-Hz square-wave amplitude modulations in an otherwise steady speech-spectrum noise was reduced substantially with vocoded sentences relative to natural speech, but was not reduced for whispered sentences. In contrast to natural speech, masking release for whispered sentences was observed even at positive signal-to-noise ratios. Whispered speech has a different short-term amplitude distribution relative to natural speech, and this appeared to explain the robust masking release for whispered speech at high signal-to-noise ratios. Recognition of whispered speech was not disproportionately affected by unpredictable modulations created by a speech-envelope modulated noise masker. Overall, the presence or absence of periodic temporal fine structure did not have a major influence on the degree of benefit obtained from imposing temporal fluctuations on a noise masker.
Journal of Neural Engineering · Oct 2012
Prasad AS, Xue QS, Sankar V, et al.
Abstract
For nearly 55 years, tungsten microwires have been widely used in neurophysiological experiments in animal models to chronically record neuronal activity. While tungsten microwires initially provide stable recordings, their inability to reliably record high-quality neural signals for tens of years has limited their efficacy for neuroprosthetic applications in humans. Comprehensive understanding of the mechanisms of electrode performance and failure is necessary for developing next generation neural interfaces for humans. In this study, we evaluated the abiotic (electrophysiology, impedance, electrode morphology) and biotic (microglial reactivity, blood-brain barrier disruption, biochemical markers of axonal injury) effects of 16-channel, 50 µm diameter, polyimide insulated tungsten microwires array for implant durations that ranged from acute to up to 9 months in 25 rats. Daily electrode impedance spectroscopy, electrophysiological recordings, blood and cerebrospinal fluid (CSF) withdrawals, and histopathological analysis were performed to study the time-varying effects of chronic electrode implantation. Structural changes at the electrode recording site were observed as early as within 2-3 h of electrode insertion. Abiotic analysis indicated the first 2-3 weeks following surgery was the most dynamic period in the chronic electrode lifetime as there were greater variations in the electrode impedance, functional electrode performance, and the structural changes occurring at the electrode recording tips. Electrode recording site deterioration continued for the long-term chronic animals as insulation damage occurred and recording surface became more recessed over time. In general, electrode impedance and functional performance had smaller daily variations combined with reduced electrode recording site changes during the chronic phase. Histopathological studies were focused largely on characterizing microglial cell responses to electrode implantation. We found that activated microglia were present near the electrode tracks in all non-acute animals studied, thus indicating presence of a neuroinflammatory response regardless of post-implantation survival times and electrode performance. Conversely, dystrophic microglia detectable as fragmented cells were found almost exclusively in acute animals surviving only few hours after implantation. While there was no consistent relationship between microglial cell responses and electrode performance, we noticed co-occurrence of high ferritin expression, intraparenchymal bleeding, and microglial degeneration suggesting presence of excessive oxidative stress via Fenton chemistry. Biochemical analysis indicated that these electrodes always caused a persistent release of axonal injury biomarkers even several months after implantation suggesting persistent tissue damage. Our study suggests that mechanisms of electrode failure are multi-factorial involving both abiotic and biotic parameters. Since these failure modes occur concurrently and cannot be isolated from one another, the lack of consistent relationship between electrode performance and microglial responses in our results suggest that one or more of the abiotic factors were equally responsible for degradation in electrode performance over long periods of time.
The Journal of the Acoustical Society of America · Oct 2012
Reichmuth C, Ghoul A, Southall BL
Abstract
In a recent study, Kastelein et al. [(2010) J. Acoust. Soc. Am. 127, 1135-1145] reported auditory integration times for harbor seals (Phoca vitulina) exceeding 3000 ms for 200 Hz tonal signals. This finding is unexpected and potentially significant given that time constants measured in mammals for tones above 1 kHz are typically less than 500 ms. To further explore this result, the hearing of another harbor seal was measured in air and water for 200 Hz tones with durations of 500 and 2500 ms. Threshold comparisons, as well as reaction time measures, revealed no gain in audibility as signal duration increased above 500 ms.
Journal of Speech, Language, and Hearing Research · Oct 2012
Sona Patel, Rahul Shrivastav, David A. Eddins
Abstract
Purpose Perceptual estimates of voice quality obtained using rating scales are subject to contextual biases that influence how individuals assign numbers to estimate the magnitude of vocal quality. Because rating scales are commonly used in clinical settings, assessments of voice quality are also subject to the limitations of these scales. Instead, a matching task can be used to obtain objective measures of voice quality, thereby facilitating model development and tools for clinical use. Method Twenty-seven individuals participated in a rating task or at least 1 of 3 matching tests (named after their modulation functions: SINE, SQUARE, POWER) to quantify the degree of roughness in dysphonic voice stimuli. Participants evaluated the roughness of 34 voice samples using an amplitude-modulated complex carrier. Results The matching thresholds were highly correlated with the ratings estimates. Reliability of thresholds did not significantly differ across tasks, but linear regressions showed that the POWER test resulted in larger perceptual distances. Conclusions A matching task can be used to obtain reliable estimates of roughness in dysphonic voices. The POWER comparison is recommended because the variability in matching thresholds across the range of roughness was evenly distributed, and the perceptual distances between stimuli were maximized.
Journal of Neurophysiology · Oct 2012
Nathaniel T. Greene, Kevin A. Davis
Abstract
Anatomical and pharmacological studies have shown that the lateral superior olive (LSO) receives inputs from a number of sources and that LSO cells can alter the balance of their own excitatory and inhibitory drive. It is thus likely that the ongoing sound-evoked responses of LSO cells reflect a complex interplay of excitatory and inhibitory events, which may be affected by anesthesia. The goal of this study was to characterize the temporal discharge patterns of single units in the LSO of unanesthetized, decerebrate cats in response to long-duration ipsilateral best-frequency tone bursts. A decision tree is presented to partition LSO units on the basis of poststimulus time histogram shape, adaptation of instantaneous firing rate as a function of time, and sustained discharge rate. The results suggest that LSO discharge patterns form a continuum with four archetypes: sustained choppers that show two or more peaks of activity at stimulus onset and little adaptation of rate throughout the response, transient choppers that undergo a decrease in rate that eventually stabilizes with time, primary-like units that display an initial peak of activity followed by a monotonic decline in rate to a steady-state value, and onset-sustained units that exhibit an initial peak of activity at stimulus onset followed by a low sustained activity. Compared with the chopper units, the nonchopper units tend to show longer first-spike latencies, lower peak firing rates, and more irregular sustained discharge patterns. Modeling studies show that the full range of LSO response types can be obtained from an underlying sustained chopper by varying the strength and latency of a sound-driven ipsilateral inhibition relative to that of excitation. Together, these results suggest that inhibition plays a major role in shaping the temporal discharge patterns of units in unanesthetized preparations.
Journal of Microelectromechanical Systems · Oct 2012
Sindhu Anand, Jemmy Sutanto, Michael S. Baker, … Jit Muthuswamy
Abstract
This paper presents a new actuation scheme for in-plane bidirectional translation of polysilicon microelectrodes. The new Chevron-peg actuation scheme uses microelectromechanical systems (MEMS) based electrothermal microactuators to move microelectrodes for brain implant applications. The design changes were motivated by specific needs identified by the in vivo testing of an earlier generation of MEMS microelectrodes that were actuated by the Chevron-latch type of mechanism. The microelectrodes actuated by the Chevron-peg mechanism discussed here show improved performance in the following key areas: higher force generation capability (111 μN per heat strip compared to 50 μN), reduced power consumption (91 mW compared to 360 mW), and reliable performance with consistent forward and backward movements of microelectrodes. Failure analysis of the Chevron-latch and the Chevron-peg type of actuation schemes showed that the latter is more robust to wear over four million cycles of operation. The parameters for the activation waveforms for Chevron-peg actuators were optimized using statistical analysis. Waveforms with a 1-ms time period and a 1-Hz frequency of operation showed minimal error between the expected and the actual movement of the microelectrodes. The new generation of Chevron-peg actuators and microelectrodes are therefore expected to enhance the longevity and performance of implanted microelectrodes in the brain. [2011-0341].
Neuroscience · Oct 2012
S. Srinivasan, A. Keil, K. Stratis, … D.W. Smith
Abstract
There is increasing evidence that alterations in the focus of attention result in changes in neural responding at the most peripheral levels of the auditory system. To date, however, those studies have not ruled out differences in task demands or overall arousal in explaining differences in responding across intermodal attentional conditions. The present study sought to compare changes in the response of cochlear outer hair cells, employing distortion product otoacoustic emissions (DPOAEs), under different, balanced conditions of intermodal attention. DPOAEs were measured while the participants counted infrequent, brief exemplars of the DPOAE primary tones (auditory attending), and while counting visual targets, which were instances of Gabor gradient phase shifts (visual attending). Corroborating an earlier study from our laboratory, the results show that DPOAEs recorded in the auditory-ignoring condition were significantly higher in overall amplitude, compared with DPOAEs recorded while participants attended to the eliciting primaries; a finding in apparent contradiction with more central measures of intermodal attention. Also consistent with our previous findings, DPOAE rapid adaptation, believed to be mediated by the medial olivocochlear efferents (MOC), was unaffected by changes in intermodal attention. The present findings indicate that manipulations in the conditions of attention, through the corticofugal pathway, and its last relay to cochlear outer hair cells (OHCs), the MOC, alter cochlear sensitivity to sound. These data also suggest that the MOC influence on OHC sensitivity is composed of two independent processes, one of which is under attentional control.
Neuroscience Letters · Oct 2012
Chun Liang, Yan Zhu, Liang Zong, … Hong-Bo Zhao
Abstract
Connexin26 (Cx26, GJB2) mutations can induce congenital deafness and are responsible for ∼50% of nonsyndromic hearing loss in children. Mouse models show that Cx26 deficiency induces cochlear development disorder, hair cell loss, and spiral ganglion (SG) neuron degeneration. Hair cell loss and cell degeneration have been considered as a primary causer responsible for Cx26 deficiency associated hearing loss. In this study, by coincidental examination of cochlear postnatal development with recording of auditory brainstem response (ABR) and hair cell function, we found that occurrence of hearing loss in Cx26 knockout (KO) mice was ahead of hair cell loss and cochlear cell degeneration. ABR was absent at the whole-frequency range (8-40 kHz) after birth. However, cochlear cells including SG neurons had no significant degeneration throughout postnatal development. Severe cochlear hair cell loss and SG neuron degeneration were only visible in middle and basal turns, i.e., in middle and high frequency regions, in the adult Cx26 KO mouse cochlea. Functional tests show that hair cells in Cx26 KO mice functioned normally; outer hair cells retained electromotility. These data suggest that cell degeneration is not a primary causer of Cx26 deficiency associated hearing loss. Some mechanisms other than cell degeneration, such as cochlear development disorders, may play an essential role in this common hereditary deafness.
The Journal of the Acoustical Society of America · Oct 2012
Skyler G. Jennings, Elizabeth A. Strickland
Abstract
The physiology of the medial olivocochlear reflex suggests that a sufficiently long stimulus (>100 ms) may reduce cochlear gain and result in broadened frequency selectivity. The current study attempted to avoid gain reduction by using short maskers (20 ms) to measure psychophysical tuning curves (PTCs) and notched-noise tuning characteristics, with a 4-kHz signal. The influence of off-frequency listening on PTCs was evaluated using two types of background noise. Iso-level curves were derived using an estimate of the cochlear input/output (I/O) function, which was obtained using an off-frequency masker as a linear reference. The influence of masker duration on PTCs was assessed using a model that assumed long maskers (>20 ms) evoked gain reduction. The results suggested that the off-frequency masker was a valid linear reference when deriving I/O functions and that off-frequency listening may have occurred in auditory filters apical to the signal place. The iso-level curves from this growth-of-masking study were consistent with those from a temporal-masking-curve study by Eustaquio-Martin and Lopez-Poveda [J. Assoc. Res. Otolaryngol. 12, 281–299. (2011)], suggesting that either approach may be used to derive iso-level curves. Finally, model simulations suggested that masker duration may not influence estimates of frequency selectivity.
The Journal of the Acoustical Society of America · Oct 2012
Skyler G. Jennings, Elizabeth A. Strickland
Abstract
Frequency selectivity was evaluated under two conditions designed to assess the influence of a “precursor” stimulus on auditory filter bandwidths. The standard condition consisted of a short masker, immediately followed by a short signal. The precursor condition was identical except a 100-ms sinusoid at the signal frequency (i.e., the precursor) was presented before the masker. The standard and precursor conditions were compared for measurements of psychophysical tuning curves (PTCs), and notched noise tuning characteristics. Estimates of frequency selectivity were significantly broader in the precursor condition. In the second experiment, PTCs in the standard and precursor conditions were simulated to evaluate the influence of the precursor on PTC bandwidth. The model was designed to account for the influence of additivity of masking between the masker and precursor. Model simulations were able to qualitatively account for the perceptual data when outer hair cell gain of the model was reduced in the precursor condition. These findings suggest that the precursor may have reduced cochlear gain, in addition to producing additivity of masking. This reduction in gain may be mediated by the medial olivocochlear reflex.
PLOS ONE · Sep 2012
Lijun Ji, Junli Zhou, Rabia Zafar, … Huabei Jiang
Abstract
While functional imaging is widely used in studies of the brain, how well the hemodynamic signal represents the underlying neural activity is still unclear. And there is a debate on whether hemodynamic signal is more tightly related to synaptic activity or action potentials. This study intends to address these questions by examining neurovascular coupling driven by pyramidal cells in the motor cortex of rats. Pyramidal cells in the motor cortex of rats were selectively transduced with the light sensitive cation channel channelrhodopsin-2 (ChR2). Electrophysiological recordings and optical intrinsic signal imaging were performed simultaneously and synchronously to capture the neural activity and hemodynamics induced by optical stimulation of ChR2-expressing pyramidal cells. Our results indicate that both synaptic activity (local field potential, LFP) and action potentials (multi-unit activity, MUA) are tightly related to hemodynamic signals. While LFPs in γ band are better in predicting hemodynamic signals elicited by short stimuli, MUA has better predictions to hemodynamic signals elicited by long stimuli. Our results also indicate that strong nonlinearity exists in neurovascular coupling.