Neuroscience · 2013
Ranasinghe KG, Vrana WA, Matney CJ, et al.
Abstract
Neurons at higher stations of each sensory system are responsive to feature combinations not present at lower levels. As a result, the activity of these neurons becomes less redundant than lower levels. We recorded responses to speech sounds from the inferior colliculus and the primary auditory cortex neurons of rats, and tested the hypothesis that primary auditory cortex neurons are more sensitive to combinations of multiple acoustic parameters compared to inferior colliculus neurons. We independently eliminated periodicity information, spectral information and temporal information in each consonant and vowel sound using a noise vocoder. This technique made it possible to test several key hypotheses about speech sound processing. Our results demonstrate that inferior colliculus responses are spatially arranged and primarily determined by the spectral energy and the fundamental frequency of speech, whereas primary auditory cortex neurons generate widely distributed responses to multiple acoustic parameters, and are not strongly influenced by the fundamental frequency of speech. We found no evidence that inferior colliculus or primary auditory cortex was specialized for speech features such as voice onset time or formants. The greater diversity of responses in primary auditory cortex compared to inferior colliculus may help explain how the auditory system can identify a wide range of speech sounds across a wide range of conditions without relying on any single acoustic cue.
Hearing Research · 2013
Lobarinas E, Salvi R, Ding D
Abstract
Noise trauma, aging, and ototoxicity preferentially damage the outer hair cells of the inner ear, leading to increased hearing thresholds and poorer frequency resolution. Whereas outer hair cells make synaptic connections with less than 10% of afferent auditory nerve fibers (type-II), inner hair cells make connections with over 90% of afferents (type-I). Despite these extensive connections, little is known about how selective inner hair cell loss impacts hearing. In chinchillas, moderate to high doses of the anticancer compound carboplatin produce selective inner hair cell and type-I afferent loss with little to no effect on outer hair cells. To determine the effects of carboplatin-induced inner hair cell loss on the most widely used clinical measure of hearing, the audiogram, pure-tone thresholds were determined behaviorally before and after 75 mg/kg carboplatin. Following carboplatin treatment, small effects on audiometric thresholds were observed even with extensive inner hair cell losses that exceed 80%. These results suggest that conventional audiometry is insensitive to inner hair cell loss and that only small populations of inner hair cells appear to be necessary for detecting tonal stimuli in a quiet background.
Neuroscience · 2013
Dansie LE, Phommahaxay K, Okusanya AG, et al.
Abstract
Fragile X Syndrome (FXS) is the most common single-gene inherited form of intellectual disability with behaviors characteristic of autism. People with FXS display childhood seizures, hyperactivity, anxiety, developmental delay, attention deficits, and visual-spatial memory impairment, as well as a propensity for obsessive-compulsive disorder. Several of these aberrant behaviors and FXS-associated synaptic irregularities also occur in "fragile X mental retardation gene" knock-out (Fmr1 KO) mice. We previously reported that minocycline promotes the maturation of dendritic spines - postsynaptic sites for excitatory synapses - in the developing hippocampus of Fmr1 KO mice, which may underlie the beneficial effects of minocycline on anxiolytic behavior in young Fmr1 KO mice. In this study, we compared the effectiveness of minocycline treatment in young and adult Fmr1 KO mice, and determined the dependence of behavioral improvements on short-term versus long-term minocycline administration. We found that 4- and 8-week-long treatments significantly reduced locomotor activity in both young and adult Fmr1 KO mice. Some behavioral improvements persisted in young mice post-treatment, but in adults the beneficial effects were lost soon after minocycline treatment was stopped. We also show, for the first time, that minocycline treatment partially attenuates the number and severity of audiogenic seizures in Fmr1 KO mice. This report provides further evidence that minocycline treatment has immediate and long-lasting benefits on FXS-associated behaviors in the Fmr1 KO mouse model.
American Journal of Audiology · 2013
Brennan MA, Gallun FJ, Souza PE, et al.
Abstract
PURPOSE: Authors of previous work using laboratory-based paradigms documented that wide dynamic range compression (WDRC) may improve gap detection compared to linear amplification. The purpose of this study was to measure temporal resolution using WDRC fit with compression ratios set for each listener’s hearing loss. METHOD: Nineteen adults with mild-to-moderate hearing loss fitted with WDRC or linear amplification set to a prescriptive fitting method participated in this study. Subjects detected amplitude modulations and gaps. Two types of noise carrier were used: narrowband (1995–2005 Hz) and broadband (100–8000 Hz). RESULTS: Small differences between WDRC and linear amplification were observed in the measures of temporal resolution. Modulation detection thresholds worsened by a mean of 0.7 dB with WDRC compared to linear amplification. This reduction was observed for both carrier types. Gap detection thresholds did not differ between the 2 amplification conditions. CONCLUSIONS: WDRC set using a prescriptive fitting method with individualized compression ratios had a small but statistically significant effect on measures of modulation thresholds. Differences were not observed between the two amplification conditions for the measures of gap detection. These findings contrast with previous work using fixed compression ratios, suggesting that the effect of the fitting method on the compression ratio should be considered when attempting to generalize the effect of WDRC on temporal resolution to the clinical setting.
Attention Perception & Psychophysics · 2013
Schmiedchen K, Freigang C, Rubsamen R, et al.
Abstract
Similarities have been observed in the localization of the final position of moving visual and moving auditory stimuli: Perceived endpoints that are judged to be farther in the direction of motion in both modalities likely reflect extrapolation of the trajectory, mediated by predictive mechanisms at higher cognitive levels. However, actual comparisons of the magnitudes of displacement between visual tasks and auditory tasks using the same experimental setup are rare. As such, the purpose of the present free-field study was to investigate the influences of the spatial location of motion offset, stimulus velocity, and motion direction on the localization of the final positions of moving auditory stimuli (Experiment 1 and 2) and moving visual stimuli (Experiment 3). To assess whether auditory performance is affected by dynamically changing binaural cues that are used for the localization of moving auditory stimuli (interaural time differences for low-frequency sounds and interaural intensity differences for high-frequency sounds), two distinct noise bands were employed in Experiments 1 and 2. In all three experiments, less precise encoding of spatial coordinates in paralateral space resulted in larger forward displacements, but this effect was drowned out by the underestimation of target eccentricity in the extreme periphery. Furthermore, our results revealed clear differences between visual and auditory tasks. Displacements in the visual task were dependent on velocity and the spatial location of the final position, but an additional influence of motion direction was observed in the auditory tasks. Together, these findings indicate that the modality-specific processing of motion parameters affects the extrapolation of the trajectory.
The Journal of the Acoustical Society of America · 2013
Sullivan JR, Thibodeau LM, Assmann PF
Abstract
Previous studies have indicated that individuals with normal hearing (NH) experience a perceptual advantage for speech recognition in interrupted noise compared to continuous noise. In contrast, adults with hearing impairment (HI) and younger children with NH receive a minimal benefit. The objective of this investigation was to assess whether auditory training in interrupted noise would improve speech recognition in noise for children with HI and perhaps enhance their utilization of glimpsing skills. A partially-repeated measures design was used to evaluate the effectiveness of seven 1-h sessions of auditory training in interrupted and continuous noise. Speech recognition scores in interrupted and continuous noise were obtained from pre-, post-, and 3 months post-training from 24 children with moderate-to-severe hearing loss. Children who participated in auditory training in interrupted noise demonstrated a significantly greater improvement in speech recognition compared to those who trained in continuous noise. Those who trained in interrupted noise demonstrated similar improvements in both noise conditions while those who trained in continuous noise only showed modest improvements in the interrupted noise condition. This study presents direct evidence that auditory training in interrupted noise can be beneficial in improving speech recognition in noise for children with HI.
Journal of Basic and Clinical Physiology and Pharmacology · 2013
Fostick L, Babkoff H
Abstract
Background The present study examined whether the reported age-related decline in auditory temporal resolution is specific to the temporal domain or rather reflects a general decline in auditory perception, including the stimulus intensity domain. Methods The performance of 89 healthy participants aged between 21 and 82 years with normal hearing was tested on a variety of psychophysical tasks, where discrimination was based either on the temporal or on the intensity domains. Stimulus levels for all tasks were 40 dB SL (corrected for threshold). Participants were also tested on two cognitive tasks: Wechsler Adult Intelligence Scale, Third Edition, matrices and digit span. Results Findings indicate that age was significantly negatively correlated with performance on three of the temporal resolution tasks, namely, dichotic temporal-order judgment, spectral temporal-order judgment, and gap detection, but not on the intensity discrimination task, thus emphasizing the specificity of the age-related decline to the auditory temporal domain. Conclusions The overall results suggest that age-related changes in auditory perception are specific to the temporal domain, even when controlling for hearing sensitivity and cognitive ability, and are not reflected in other aspects of non-temporal perception, such as intensity discrimination.
Experimental Psychology · 2013
Fostick L, Babkoff H
Abstract
Temporal order judgment (TOJ) thresholds have been widely reported as valid estimates of the temporal disparity necessary for correctly identifying the order of two stimuli. Data for two auditory TOJ paradigms are often reported in the literature: (1) spatially-based TOJ in which the order of presentation of the same stimulus to the right and left ear differs; and (2) spectrally-based TOJ in which the order of two stimuli differing in frequency is presented to one ear or to both ears simultaneously. Since the thresholds reported using the two paradigms differ, the aim of the current study was to compare their response patterns. The results from three different experiments showed that: (1) while almost none of the participants were able to perform the spatial TOJ task when ISI = 5 ms, with the spectral task, 50% reached an accuracy level of 75% when ISI = 5 ms; (2) temporal separation was only a partial predictor for performance in the spectral task, while it fully predicted performance in the spatial task; and (3) training improved performance markedly in the spectral TOJ task, but had no effect on spatial TOJ. These results suggest that the two paradigms may reflect different perceptual mechanisms.
Advances in Experimental Medicine and Biology · 2013
Dietz M, Marquardt T, Greenberg D, McAlpine D
Abstract
Recently, Klein-Hennig et al. (J Acoust Soc Am 129:3856–3872, 2011) suggested a design for envelope waveforms that allows for independent setting of the duration of the four segments of an envelope cycle – pause, attack, sustain, and decay. These authors conducted psychoacoustic experiments to determine the threshold interaural time differences (ITDs) for different waveforms and revealed that a steep attack flank and at least 4 ms of pause duration prior to the attack are optimal for discrimination performance, whilst sustained and decay durations were of only minor influence. The current study tests the sharpness of rate-ITD-functions recorded in the inferior colliculus of guinea pigs in response to a similar set of waveforms, examining their relationship to the psychoacoustic data. Particular focus is applied to temporally asymmetric envelope waveforms: a long 15-ms attack and a short 1.5-ms decay envelope and the temporally inverted envelope with a short 1.5-ms attack and a long 15-ms decay.
JAMA Otolaryngology–Head & Neck Surgery · 2013
Park AH, Mann D, Error ME, … Schleiss MR
Abstract
Objective To assess the validity of the guinea pig as a model for congenital cytomegalovirus (CMV) infection by comparing the effectiveness of detecting the virus by real-time polymerase chain reaction (PCR) in blood, urine, and saliva. Design Case-control study. Setting Academic research. Subjects Eleven pregnant Hartley guinea pigs. Main outcome measures Blood, urine, and saliva samples were collected from guinea pig pups delivered from pregnant dams inoculated with guinea pig CMV. These samples were then evaluated for the presence of guinea pig CMV by real-time PCR assuming 100% transmission. Results Thirty-one pups delivered from 9 inoculated pregnant dams and 8 uninfected control pups underwent testing for guinea pig CMV and for auditory brainstem response hearing loss. Repeated-measures analysis of variance demonstrated no statistically significantly lower weight for the infected pups compared with the noninfected control pups. Six infected pups demonstrated auditory brainstem response hearing loss. The sensitivity and specificity of the real-time PCR assay on saliva samples were 74.2% and 100.0%, respectively. The sensitivity of the real-time PCR on blood and urine samples was significantly lower than that on saliva samples. Conclusions Real-time PCR assays of blood, urine, and saliva revealed that saliva samples show high sensitivity and specificity for detecting congenital CMV infection in guinea pigs. This finding is consistent with recent screening studies in human newborns. The guinea pig may be a good animal model in which to compare different diagnostic assays for congenital CMV infection.
Journal of the American Academy of Audiology · 2013
Picou EM, Ricketts TA
Abstract
Background Understanding speech over the telephone when listening in noisy environments may present a significant challenge for listeners with moderate-to-severe hearing loss. Purpose The purpose of this study was to compare speech recognition and subjective ratings across several hearing aid-based telephone listening strategies for individuals with moderate-to-severe sensorineural hearing loss. Research design Speech recognition and subjective ratings were evaluated for a simulated telephone signal. The strategies evaluated included acoustic telephone, unilateral telecoil, unilateral wireless streaming, and bilateral wireless streaming. Participants were seated in a noisy room for all evaluations. Study sample Eighteen adults, aged 49-88 yr, with moderate-to-severe sensorineural hearing loss participated. Data collection and analysis Speech recognition scores on the Connected Speech Test were converted to rationalized arcsine units and analyzed using analysis of variance testing and Tukey post hoc analyses. Subjective ratings of ease and comfort were also analyzed in this manner. Results Speech recognition performance was poorest with acoustic coupling to the telephone and best with bilateral wireless routing. Telecoil coupling resulted in better speech recognition performance than acoustic coupling, but was significantly poorer than bilateral wireless routing. Furthermore, unilateral wireless routing and telecoil coupling generally led to similar speech recognition performance, except in lower-level background noise conditions, for which unilateral routing resulted in better performance than the telecoil. Conclusions For people with moderate-to-severe sensorineural hearing loss, acoustic telephone listening with a hearing aid may not lead to acceptable performance in noise. Although unilateral routing options (telecoil and wireless streaming) improved performance, speech recognition performance and subjective ratings of ease and comfort were best when bilateral wireless routing was used. These results suggest that wireless routing is a potentially beneficial telephone listening strategy for listeners with moderate-to-severe hearing loss who are fitted with limited venting if the telephone signal is routed to both ears. Unilateral wireless routing may provide similar benefits to traditional unilateral telecoil. However, the newer wireless systems may have the advantage for some listeners in that they do not include some of the positioning constraints associated with telecoil use.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013
Bae J, Sanchez Giraldo LG, Pohlmeyer EA, … Principe JC
Abstract
This paper presents the first attempt to quantify the individual performance of the subject and of the computer agent on a closed loop Reinforcement Learning Brain Machine Interface (RLBMI). The distinctive feature of the RLBMI architecture is the co-adaptation of two systems (a BMI decoder in agent and a BMI user in environment). In this work, an agent implemented using Q-learning via kernel temporal difference (KTD)(λ) decodes the neural states of a monkey and transforms them into action directions of a robotic arm. We analyze how each participant influences the overall performance both in successful and missed trials by visualizing states, corresponding action value Q, and resulting actions in two-dimensional space. With the proposed methodology, we can observe how the decoder effectively learns a good state to action mapping, and how neural states affect the prediction performance.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013
Khurram A, Seymour JP
Abstract
The combination of optical stimulation and electrical recording is commonly employed in neuroscience research. Researchers using optogenetics are familiar with the photo-induced "artifacts" that arise from illumination of an electrode array. We sought to characterize this photoelectrochemical (PEC) effect to understand the underlying mechanism seen on NeuroNexus optoelectrodes. In doing so, we discovered that the phenomenon is inversely proportional to electrode site area in the same manner as electrical impedance measurements. We have applied the PEC effect as a method of electrode evaluation and show that a PEC measurement system can be both faster and more effective than impedance at sensing defects in high-throughput biomedical device testing.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013
Tanyous F, Al Abed A, Bradd A, … Dokos S
Abstract
An isolated rabbit cardiac sinoatrial node (SAN) tissue preparation was used experimentally to map activation times and conduction velocities of extracellular cardiac action potential (AP) propagation. Extracellular recordings were carried out using a two-dimensional array of unipolar Ag-AgCl microelectrodes connected to a 128-channel data acquisition system. A 20(th) order, low-pass Butterworth filter, with a cut-off frequency of 50 Hz, was used in conjunction with a Matlab algorithm to map activation times and conduction velocities. Results show an initial slow-down of the activation wavefront emanating from the SAN, followed by acceleration in some regions, particularly near the Superior Vena Cava, as it travels towards the SAN periphery.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013
Ledochowitsch P, Koralek AC, Moses D, … Maharbiz MM
Abstract
Volitional control of neural activity lies at the heart of the Brain-Machine Interface (BMI) paradigm. In this work we investigated if subdural field potentials recorded by electrodes < 1mm apart can be decoupled through closed-loop BMI learning. To this end, we fabricated custom, flexible microelectrode arrays with 200 µm electrode pitch and increased the effective electrode area by electrodeposition of platinum black to reduce thermal noise. We have chronically implanted these arrays subdurally over primary motor cortex (M1) of 5 male Long-Evans Rats and monitored the electrochemical electrode impedance in vivo to assess the stability of these neural interfaces. We successfully trained the rodents to perform a one-dimensional center-out task using closed-loop brain control to adjust the pitch of an auditory cursor by differentially modulating high gamma (70-110 Hz) power on pairs of surface microelectrodes that were separated by less than 1 mm.
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013
Prins NW, Geng S, Pohlmeyer EA, … Sanchez JC
Abstract
New reinforcement based paradigms for building adaptive decoders for Brain-Machine Interfaces involve using feedback directly from the brain. In this work, we investigated neuromodulation in the Nucleus Accumbens (reward center) during a multi-target reaching task and investigated how to extract a reinforcing or non-reinforcing signal that could be used to adapt a BMI decoder. One of the challenges in brain-driven adaptation is how to translate biological neuromodulation into a single binary signal from the distributed representation of the neural population, which may encode many aspects of reward. To extract these signals, feature analysis and clustering were used to identify timing and coding properties of a user's neuromodulation related to reward perception. First, Principal Component Analysis (PCA) of reward related neural signals was used to extract variance in the firing and the optimum time correlation between the neural signal and the reward phase of the task. Next, k-means clustering was used to separate data into two classes.
Acoustical Science and Technology · 2013
Kazuhito Ito, Seiji Nakagawa
Abstract
Tympanic membrane (TM) vibration under bone-conducted ultrasonic (BCU) stimulation was measured in four living human subjects using a laser Doppler vibrometer (LDV) to investigate the contributions of nonlinear distortions in the osseotympanic effects and/or the inertial effects of the middle-ear ossicles to ultrasonic perception in bone conduction. A signal processing algorithm to increase the signal-to-noise ratios of measured LDV signals by removing only optical spike noise components from the wave signals was presented in this study. Evidence of nonlinear distortions, especially the generation of audible subharmonics in the outer and middle ear, was then examined. We did not find any audible signals corresponding to the subjective pitch of a BCU tone in the TM vibrations. This suggests that nonlinear distortions in the osseotympanic and inertial effects do not contribute to BCU perception. Specific properties of perception may be related to mechanisms in the cochlea or afferent neural pathway. With this consideration, we discuss the possibility that the pitch perception of BCU does not relate to tonotopical motion of the basilar membrane corresponding to the subjective pitch, given that TM vibration can reflect the motion of cochlear fluid and hence the motion of the basilar membrane.
Texas ScholarWorks (Texas Digital Library) · 2013
Pho MH
Scholarship@Western (Western University) · 2013
Suelzle D
Proceedings of Meetings on Acoustics · 2013
Rói Hansen, Sébastien Santurette, Sarah Verhulst
Abstract
When an external tone is presented in proximity to the frequency of a spontaneous otoacoustic emission (SOAE), the SOAE typically synchronizes to the external tone, a phenomenon known as "entrainment". As the tone moves further away from the SOAE frequency, beating patterns between the SOAE and the pure tone occur (Long, Hear. Res. 119, 1998). This study investigated perceptual consequences of SOAE beating and entrainment on the frequency difference limen (FDL), which has been found to improve near an SOAE. SOAE entrainment patterns were obtained for six subjects with a strong SOAE in the ipsilateral ear and no SOAE in the corresponding frequency range of the contralateral ear. Hearing thresholds and FDLs were measured ipsi- and contralaterally for nine frequencies covering the entrainment and beating regions of the SOAE. FDLs systematically improved in the entrainment region, worsened when beating occurred, and improved again for frequencies further away from the SOAE. No improvement in FDL was found in any of the contralateral ears tested, suggesting that the effect is of peripheral, rather than of central, origin. The results contradict an earlier hypothesis stating that FDL performance near SOAE frequencies is governed by a central oversensitivity to the SOAE frequency.