TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

Journal of Neural Engineering · Jun 2014

A partial hearing animal model for chronic electro-acoustic stimulation (opens in a new tab)

S Irving, A K Wise, R E Millard, … J B Fallon

Abstract

Objective: Cochlear implants (CIs) have provided some auditory function to hundreds of thousands of people around the world. Although traditionally carried out only in profoundly deaf patients, the eligibility criteria for implantation have recently been relaxed to include many partially-deaf patients with useful levels of hearing. These patients receive both electrical stimulation from their implant and acoustic stimulation via their residual hearing (electro-acoustic stimulation; EAS) and perform very well. It is unclear how EAS improves speech perception over electrical stimulation alone, and little evidence exists about the nature of the interactions between electric and acoustic stimuli. Furthermore, clinical results suggest that some patients that undergo cochlear implantation lose some, if not all, of their residual hearing, reducing the advantages of EAS over electrical stimulation alone. A reliable animal model with clinically-relevant partial deafness combined with clinical CIs is important to enable these issues to be studied. This paper outlines such a model that has been successfully used in our laboratory. Approach: This paper outlines a battery of techniques used in our laboratory to generate, validate and examine an animal model of partial deafness and chronic CI use. Main results: Ototoxic deafening produced bilaterally symmetrical hearing thresholds in neonatal and adult animals. Electrical activation of the auditory system was confirmed, and all animals were chronically stimulated via adapted clinical CIs. Acoustic compound action potentials (CAPs) were obtained from partially-hearing cochleae, using the CI amplifier. Immunohistochemical analysis allows the effects of deafness and electrical stimulation on cell survival to be studied. Significance: This animal model has applications in EAS research, including investigating the functional interactions between electric and acoustic stimulation, and the development of techniques to maintain residual hearing following cochlear implantation. The ability to record CAPs via the CI has clinical direct relevance for obtaining objective measures of residual hearing.

PLOS ONE · Jun 2014

Real-time dopamine measurement in awake monkeys (opens in a new tab)

Erik W. Schluter, Andrew R. Mitz, Joseph F. Cheer, Bruno B. Averbeck

Abstract

Fast-scan cyclic voltammetry (FSCV) is often used to measure real-time dopamine (DA) concentrations in awake, behaving rodents. Extending this technique to work in monkeys would provide a platform for advanced behavioral studies and a primate model for preclinical research. The present study demonstrates the feasibility of DA recordings in two awake monkeys (Macaca mulatta) using a mixture of techniques adapted from rodent, primate and brain slice work. We developed a long carbon fiber electrode to operate in the larger primate brain. This electrode was lowered into the striatum each day using a recording chamber and a detachable micromanipulator system. A manipulator also moved one or more tungsten stimulating electrodes into either the nearby striatum or the ventral tegmental area/substantia nigra pars compacta (VTA/SNc). We developed an electrical stimulation controller to reduce artifacts during electrical stimulation. We also introduce a stimulation-based methodology for estimating distances between electrodes in the brain. Dopamine responses within the striatum were evoked by either stimulation of the striatum near the FSCV electrode, or stimulation within the VTA/SNc. Unexpected juice rewards also evoked dopamine responses in the ventral striatum. Thus, we demonstrate that robust dopamine responses can be recorded from awake, behaving primates with FSCV. In addition, we describe how a stimulation technique borrowed from the neuroprosthetics field can activate the distributed monkey midbrain dopamine system in a way that mimics rodent VTA stimulation.

Frontiers in Neuroengineering · Jun 2014

Deep brain stimulation macroelectrodes compared to multiple microelectrodes in rat hippocampus (opens in a new tab)

Sharanya Arcot Desai, Claire-Anne Gutekunst, Steve M. Potter, Robert E. Gross

Abstract

Microelectrode arrays (wire diameter <50 μm) were compared to traditional macroelectrodes for deep brain stimulation (DBS). Understanding the neuronal activation volume may help solve some of the mysteries associated with DBS, e.g., its mechanisms of action. We used c-fos immunohistochemistry to investigate neuronal activation in the rat hippocampus caused by multi-micro- and macroelectrode stimulation. At ± 1V stimulation at 25 Hz, microelectrodes (33 μm diameter) had a radius of activation of 100 μm, which is 50% of that seen with 150 μm diameter macroelectrode stimulation. Macroelectrodes activated about 5.8 times more neurons than a single microelectrode, but displaced ~20 times more neural tissue. The sphere of influence of stimulating electrodes can be significantly increased by reducing their impedance. By ultrasonic electroplating (sonicoplating) the microelectrodes with platinum to increase their surface area and reduce their impedance by an order of magnitude, the radius of activation increased by 50 μm and more than twice the number of neurons were activated within this increased radius compared to unplated microelectrodes. We suggest that a new approach to DBS, one that uses multiple high-surface area microelectrodes, may be more therapeutically effective due to increased neuronal activation.

Cell Death & Disease · Jun 2014

Augmentation of NAD(+) by NQO1 attenuates cisplatin-mediated hearing impairment (opens in a new tab)

H-J Kim, G-S Oh, A Shen, … H-S So

Abstract

Cisplatin (cis-diaminedichloroplatinum-II) is an extensively used chemotherapeutic agent, and one of its most adverse effects is ototoxicity. A number of studies have demonstrated that these effects are related to oxidative stress and DNA damage. However, the precise mechanism underlying cisplatin-associated ototoxicity is still unclear. The cofactor nicotinamide adenine dinucleotide (NAD(+)) has emerged as a key regulator of cellular energy metabolism and homeostasis. Here, we demonstrate for the first time that, in cisplatin-mediated ototoxicity, the levels and activities of SIRT1 are suppressed by the reduction of intracellular NAD(+) levels. We provide evidence that the decrease in SIRT1 activity and expression facilitated by increasing poly(ADP-ribose) transferase (PARP)-1 activation and microRNA-34a through p53 activation aggravates cisplatin-mediated ototoxicity. Moreover, we show that the induction of cellular NAD(+) levels using β-lapachone (β-Lap), whose intracellular target is NQO1, prevents the toxic effects of cisplatin through the regulation of PARP-1 and SIRT1 activity. These results suggest that direct modulation of cellular NAD(+) levels by pharmacological agents could be a promising therapeutic approach for protection from cisplatin-induced ototoxicity.

Frontiers in Neuroscience · Jun 2014

Impact of hearing protection devices on sound localization performance (opens in a new tab)

Véronique Zimpfer, David Sarafian

Abstract

Hearing Protection Devices (HPDs) can protect the ear against loud potentially damaging sounds while allowing lower-level sounds such as speech to be perceived. However, the impact of these devices on the ability to localize sound sources is not well known. To address this question, we propose two different methods: one behavioral and one dealing with acoustical measurements. For the behavioral method, sound localization performance was measured with, and without, HPDs on 20 listeners. Five HPDs, including both passive (non-linear attenuation) and three active (talk-through) systems were evaluated. The results showed a significant increase in localization errors, especially front-back and up-down confusions relative to the "naked ear" test condition for all of the systems tested, especially for the talk-through headphone system. For the acoustic measurement method, Head-Related Transfer Functions (HRTFs) were measured on an artificial head both without, and with the HPDs in place. The effects of the HPDs on the spectral cues for the localization of different sound sources in the horizontal plane were analyzed. Alterations of the Interaural Spectral Difference (ISD) cues were identified, which could explain the observed increase in front-back confusions caused by the talk-through headphone protectors.

Frontiers in Physiology · Jun 2014

Dichotic sound localization properties of duration-tuned neurons in the inferior colliculus of the big brown bat (opens in a new tab)

Riziq Sayegh, Brandon Aubie, Paul A. Faure

PA5Apos IIDA3FT6SM5PC1SD1ET1TG6Auditory NeurophysiologySingle Unit
Abstract

Electrophysiological studies on duration-tuned neurons (DTNs) from the mammalian auditory midbrain have typically evoked spiking responses from these cells using monaural or free-field acoustic stimulation focused on the contralateral ear, with fewer studies devoted to examining the electrophysiological properties of duration tuning using binaural stimulation. Because the inferior colliculus (IC) receives convergent inputs from lower brainstem auditory nuclei that process sounds from each ear, many midbrain neurons have responses shaped by binaural interactions and are selective to binaural cues important for sound localization. In this study, we used dichotic stimulation to vary interaural level difference (ILD) and interaural time difference (ITD) acoustic cues and explore the binaural interactions and response properties of DTNs and non-DTNs from the IC of the big brown bat (Eptesicus fuscus). Our results reveal that both DTNs and non-DTNs can have responses selective to binaural stimulation, with a majority of IC neurons showing some type of ILD selectivity, fewer cells showing ITD selectivity, and a number of neurons showing both ILD and ITD selectivity. This study provides the first demonstration that the temporally selective responses of DTNs from the vertebrate auditory midbrain can be selective to binaural cues used for sound localization in addition to having spiking responses that are selective for stimulus frequency, amplitude, and duration.

PLOS ONE · Jun 2014

Effects of contralateral noise on the 20-Hz auditory steady state response–magnetoencephalography study (opens in a new tab)

Hajime Usubuchi, Tetsuaki Kawase, Akitake Kanno, … Yukio Katori

Abstract

The auditory steady state response (ASSR) is an oscillatory brain response, which is phase locked to the rhythm of an auditory stimulus. ASSRs have been recorded in response to a wide frequency range of modulation and/or repetition, but the physiological features of the ASSRs are somewhat different depending on the modulation frequency. Recently, the 20-Hz ASSR has been emphasized in clinical examinations, especially in the area of psychiatry. However, little is known about the physiological properties of the 20-Hz ASSR, compared to those of the 40-Hz and 80-Hz ASSRs. The effects of contralateral noise on the ASSR are known to depend on the modulation frequency to evoke ASSR. However, the effects of contralateral noise on the 20-Hz ASSR are not known. Here we assessed the effects of contralateral white noise at a level of 70 dB SPL on the 20-Hz and 40-Hz ASSRs using a helmet-shaped magnetoencephalography system in 9 healthy volunteers (8 males and 1 female, mean age 31.2 years). The ASSRs were elicited by monaural 1000-Hz 5-s tone bursts amplitude-modulated at 20 and 39 Hz and presented at 80 dB SPL. Contralateral noise caused significant suppression of both the 20-Hz and 40-Hz ASSRs, although suppression was significantly smaller for the 20-Hz ASSRs than the 40-Hz ASSRs. Moreover, the greatest suppression of both 20-Hz and 40-Hz ASSRs occurred in the right hemisphere when stimuli were presented to the right ear with contralateral noise. The present study newly showed that 20-Hz ASSRs are suppressed by contralateral noise, which may be important both for characterization of the 20-Hz ASSR and for interpretation in clinical situations. Physicians must be aware that the 20-Hz ASSR is significantly suppressed by sound (e.g. masking noise or binaural stimulation) applied to the contralateral ear.

Psychophysiology · Jun 2014

Speech-perception training for older adults with hearing loss impacts word recognition and effort (opens in a new tab)

Stefanie E. Kuchinsky, Jayne B. Ahlstrom, Stephanie L. Cute, … Mark A. Eckert

System 3RP2.1HB7Psychoacoustics
Abstract

The current pupillometry study examined the impact of speech‐perception training on word recognition and cognitive effort in older adults with hearing loss. Trainees identified more words at the follow‐up than at the baseline session. Training also resulted in an overall larger and faster peaking pupillary response, even when controlling for performance and reaction time. Perceptual and cognitive capacities affected the peak amplitude of the pupil response across participants but did not diminish the impact of training on the other pupil metrics. Thus, we demonstrated that pupillometry can be used to characterize training‐related and individual differences in effort during a challenging listening task. Importantly, the results indicate that speech‐perception training not only affects overall word recognition, but also a physiological metric of cognitive effort, which has the potential to be a biomarker of hearing loss intervention outcome.

Cerebral Cortex · Jun 2014

Parcellation of Human and Monkey Core Auditory Cortex with fMRI Pattern Classification and Objective Detection of Tonotopic Gradient Reversals (opens in a new tab)

Marc Schönwiesner, Peter Dechent, Dirk Voit, … Katrin Krumbholz

Abstract

Auditory cortex (AC) contains several primary-like, or "core," fields, which receive thalamic input and project to non-primary "belt" fields. In humans, the organization and layout of core and belt auditory fields are still poorly understood, and most auditory neuroimaging studies rely on macroanatomical criteria, rather than functional localization of distinct fields. A myeloarchitectonic method has been suggested recently for distinguishing between core and belt fields in humans (Dick F, Tierney AT, Lutti A, Josephs O, Sereno MI, Weiskopf N. 2012. In vivo functional and myeloarchitectonic mapping of human primary auditory areas. J Neurosci. 32:16095-16105). We propose a marker for core AC based directly on functional magnetic resonance imaging (fMRI) data and pattern classification. We show that a portion of AC in Heschl's gyrus classifies sound frequency more accurately than other regions in AC. Using fMRI data from macaques, we validate that the region where frequency classification performance is significantly above chance overlaps core auditory fields, predominantly A1. Within this region, we measure tonotopic gradients and estimate the locations of the human homologues of the core auditory subfields A1 and R. Our results provide a functional rather than anatomical localizer for core AC. We posit that inter-individual variability in the layout of core AC might explain disagreements between results from previous neuroimaging and cytological studies.

Journal of the Association for Research in Otolaryngology · Jun 2014

Estimation of neural phase locking from stimulus-evoked potentials (opens in a new tab)

Eric Verschooten, Philip X. Joris

Abstract

The frequency extent over which fine structure is coded in the auditory nerve has been physiologically characterized in laboratory animals but is unknown in humans. Knowledge of the upper frequency limit in humans would inform the debate regarding the role of fine structure in human hearing. Of the presently available techniques, only the recording of mass neural potentials offers the promise to provide a physiological estimate of neural phase locking in humans. A challenge is to disambiguate neural phase locking from the receptor potentials. We studied mass potentials recorded on the cochlea and auditory nerve of cat and used several experimental manipulations to isolate the neural contribution to these potentials. We find a surprisingly large neural contribution in the signal recorded on the cochlear round window, and this contribution is in many aspects similar to the potential measured on the auditory nerve. The results suggest that recording of mass potentials through the middle ear is a promising approach to examine neural phase locking in humans.

PLOS ONE · Jun 2014

Sox10 expressing cells in the lateral wall of the aged mouse and human cochlea (opens in a new tab)

Xinping Hao, Yazhi Xing, Michael W. Moore, … Hainan Lang

System 3SigGenABR/DPOAE
Abstract

Age-related hearing loss (presbycusis) is a common human disorder, affecting one in three Americans aged 60 and over. Previous studies have shown that presbyacusis is associated with a loss of non-sensory cells in the cochlear lateral wall. Sox10 is a transcription factor crucial to the development and maintenance of neural crest-derived cells including some non-sensory cell types in the cochlea. Mutations of the Sox10 gene are known to cause various combinations of hearing loss and pigmentation defects in humans. This study investigated the potential relationship between Sox10 gene expression and pathological changes in the cochlear lateral wall of aged CBA/CaJ mice and human temporal bones from older donors. Cochlear tissues prepared from young adult (1-3 month-old) and aged (2-2.5 year-old) mice, and human temporal bone donors were examined using quantitative immunohistochemical analysis and transmission electron microscopy. Cells expressing Sox10 were present in the stria vascularis, outer sulcus and spiral prominence in mouse and human cochleas. The Sox10(+) cell types included marginal and intermediate cells and outer sulcus cells, including those that border the scala media and those extending into root processes (root cells) in the spiral ligament. Quantitative analysis of immunostaining revealed a significant decrease in the number of Sox10(+) marginal cells and outer sulcus cells in aged mice. Electron microscopic evaluation revealed degenerative alterations in the surviving Sox10(+) cells in aged mice. Strial marginal cells in human cochleas from donors aged 87 and older showed only weak immunostaining for Sox10. Decreases in Sox10 expression levels and a loss of Sox10(+) cells in both mouse and human aged ears suggests an important role of Sox10 in the maintenance of structural and functional integrity of the lateral wall. A loss of Sox10(+) cells may also be associated with a decline in the repair capabilities of non-sensory cells in the aged ear.

Journal of Micromechanics and Microengineering · Jun 2014

Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle (opens in a new tab)

Xiang Z, Yen SC, Xue N, et al.

Abstract

The ultra-thin flexible polyimide neural probe can reduce the glial sheath growth on the probe body while its flexibility can minimize the micromotion between the probe and brain tissue. To provide sufficient stiffness for penetration purposes, we developed a drawing lithography technology for uniform maltose coating to make the maltose-coated polyimide neural probe become a stiff microneedle. The coating thicknesses under different temperature and the corresponding stiffness are studied. It has been proven that the coated maltose is dissolved by body fluids after implantation for a few seconds. Moreover, carbon nanotubes are coated on the neural probe recording electrodes to improve the charge delivery ability and reduce the impedance. Last but not least, the feasibility and recording characteristic of this ultra-thin polyimide neural probe embedded in a maltose-coated microneedle are further demonstrated by in vivo tests.

Journal of Neural Engineering · Jun 2014

Chronic recruitment of primary afferent neurons by microstimulation in the feline dorsal root ganglia (opens in a new tab)

Fisher LE, Ayers CA, Ciollaro M, et al.

Abstract

OBJECTIVE: This study describes results of primary afferent neural microstimulation experiments using microelectrode arrays implanted chronically in the lumbar dorsal root ganglia (DRG) of four cats. The goal was to test the stability and selectivity of these microelectrode arrays as a potential interface for restoration of somatosensory feedback after damage to the nervous system such as amputation. APPROACH: A five-contact nerve-cuff electrode implanted on the sciatic nerve was used to record the antidromic compound action potential response to DRG microstimulation (2-15 µA biphasic pulses, 200 µs cathodal pulse width), and the threshold for eliciting a response was tracked over time. Recorded responses were segregated based on conduction velocity to determine thresholds for recruiting Group I and Group II/Aβ primary afferent fibers. MAIN RESULTS: Thresholds were initially low (5.1 ± 2.3 µA for Group I and 6.3 ± 2.0 µA for Group II/Aβ) and increased over time. Additionally the number of electrodes with thresholds less than or equal to 15 µA decreased over time. Approximately 12% of tested electrodes continued to elicit responses at 15 µA up to 26 weeks after implantation. Higher stimulation intensities (up to 30 µA) were tested in one cat at 23 weeks post-implantation yielding responses on over 20 additional electrodes. Within the first six weeks after implantation, approximately equal numbers of electrodes elicited only Group I or Group II/Aβ responses at threshold, but the relative proportion of Group II/Aβ responses decreased over time. SIGNIFICANCE: These results suggest that it is possible to activate Group I or Group II/Aβ primary afferent fibers in isolation with penetrating microelectrode arrays implanted in the DRG, and that those responses can be elicited up to 26 weeks after implantation, although it may be difficult to achieve a consistent response day-to-day with currently available electrode technology. The DRG are compelling targets for sensory neuroprostheses with potential to achieve recruitment of a range of sensory fiber types over multiple months after implantation.

Language and Speech · Jun 2014

Durations of American English vowels by native and non-native speakers: Acoustic analyses and perceptual effects (opens in a new tab)

Liu C, Jin SH, Chen CT

Abstract

The goal of this study was to examine durations of American English vowels produced by English-, Chinese-, and Korean-native speakers and the effects of vowel duration on vowel intelligibility. Twelve American English vowels were recorded in the /hVd/ phonetic context by native speakers and non-native speakers. The English vowel duration patterns as a function of vowel produced by non-native speakers were generally similar to those produced by native speakers. These results imply that using duration differences across vowels may be an important strategy for non-native speakers' production before they are able to employ spectral cues to produce and perceive English speech sounds. In the intelligibility experiment, vowels were selected from 10 native and non-native speakers and vowel durations were equalized at 170 ms. Intelligibility of vowels with original and equalized durations was evaluated by American English native listeners. Results suggested that vowel intelligibility of native and non-native speakers degraded slightly by 3-8% when durations were equalized, indicating that vowel duration plays a minor role in vowel intelligibility.

Journal of Neurophysiology · Jun 2014

Genetic disruption of the On visual pathway affects cortical orientation selectivity and contrast sensitivity in mice (opens in a new tab)

Rashmi Sarnaik, Hui Chen, Xiaorong Liu, Jianhua Cang

Abstract

The retina signals stimulus contrast via parallel On and Off pathways and sends the information to higher visual centers. Here we study the role of the On pathway using mice that have null mutations in the On-specific GRM6 receptor in the retina (Pinto LH, Vitaterna MH, Shimomura K, Siepka SM, Balannik V, McDearmon EL, Omura C, Lumayag S, Invergo BM, Brandon M, Glawe B, Cantrell DR, Donald R, Inayat S, Olvera MA, Vessey KA, Kirstan A, McCall MA, Maddox D, Morgans CW, Young B, Pletcher MT, Mullins RF, Troy JB, Takahashi JS. Vis Neurosci 24: 111–123, 2007; Maddox DM, Vessey KA, Yarbrough GL, Invergo BM, Cantrell DR, Inayat S, Balannik V, Hicks WL, Hawes NL, Byers S, Smith RS, Hurd R, Howell D, Gregg RG, Chang B, Naggert JK, Troy JB, Pinto LH, Nishina PM, McCall MA. J Physiol 586: 4409–4424, 2008). In these “nob” mice, single unit recordings in the primary visual cortex (V1) reveal degraded selectivity for orientations due to an increased response at nonpreferred orientations. Contrast sensitivity in the nob mice is reduced with severe deficits at low contrast, consistent with the phenotype of night blindness in human patients with mutations in Grm6. These cortical deficits can be largely explained by reduced input drive and increased response variability seen in nob V1. Interestingly, increased variability is also observed in the superior colliculus of these mice but does not affect its tuning properties. Further, the increased response variability in the nob mice is traced to the retina, a result phenocopied by acute pharmacological blockade of the On pathway in wild-type retina. Together, our results suggest that the On and Off pathways normally interact to increase response reliability in the retina, which in turn propagates to various central visual targets and affects their functional properties.

Hearing Research · Jun 2014

Natural variability in species-specific vocalizations constrains behavior and neural activity (opens in a new tab)

Kate L. Christison-Lagay, Sharath Bennur, Jennifer Blackwell, … Yale E. Cohen

Abstract

A listener's capacity to discriminate between sounds is related to the amount of acoustic variability that exists between these sounds. However, a full understanding of how this natural variability impacts neural activity and behavior is lacking. Here, we tested monkeys' ability to discriminate between different utterances of vocalizations from the same acoustic class (i.e., coos and grunts), while neural activity was simultaneously recorded in the anterolateral belt region (AL) of the auditory cortex, a brain region that is a part of a pathway that mediates auditory perception. Monkeys could discriminate between coos better than they could discriminate between grunts. We also found AL activity was more informative about different coos than different grunts. This difference could be attributed, in part, to our finding that coos had more acoustic variability than grunts. Thus, intrinsic acoustic variability constrained the discriminability of AL spike trains and the ability of rhesus monkeys to discriminate between vocalizations.

2014 Solid-State, Actuators, and Microsystems Workshop Technical Digest · May 2014

DEVELOPMENT AND IN VIVO TESTING OF RECONFIGURABLE NEURAL PROBES FOR CHRONIC ELECTRICAL RECORDING (opens in a new tab)

A. Dighe, U.P. Froriep, M. Sunshine, … J. Voldman

Abstract

We present the successful in vivo testing of a triggerable, reconfigurable neural probe designed to record neural activity in the central nervous system for extended periods of time.The probe consists of a thin polyimide-gold-polyimide sandwich structure that can be deflected prior to insertion to store mechanical energy.After inserting into the brain and waiting for the initial glial sheath to form, the device can be triggered, causing the recording tip of the device to penetrate into fresh tissue.Here we present the first in vivo triggering and acute electrical recordings from this device in the rodent motor cortex, demonstrating the essential device functionality.

Cell Death & Disease · May 2014

Receptor-interacting protein kinases modulate noise-induced sensory hair cell death (opens in a new tab)

H-W Zheng, J Chen, S-H Sha

System 3SigGenBioSigABR/DPOAE
Abstract

Receptor-interacting protein (RIP) kinases promote the induction of necrotic cell death pathways. Here we investigated signaling pathways in outer hair cells (OHCs) of adult male CBA/J mice exposed to noise that causes permanent threshold shifts, with a particular focus on RIP kinase-regulated necroptosis. One hour after noise exposure, nuclei of OHCs in the basal region of the cochlea displayed both apoptotic and necrotic features. RIP1 and RIP3 protein levels increased and caspase-8 was activated. Treatment with pan-caspase inhibitor ZVAD blocked the activation of caspase-8 and reduced the number of apoptotic nuclei, while increasing levels of RIP1, RIP3, and necrotic OHCs. Conversely, treatment with necrosis inhibitor necrostatin-1 (Nec-1) or RIP3 siRNA (siRIP3) diminished noise-induced increases in RIP1 and RIP3, and decreased necrotic OHC nuclei. This treatment also increased the number of apoptotic nuclei without increasing activation of caspase-8. Consistent with the elevation of levels of RIP1 and RIP3, noise-induced active AMPKα levels increased with ZVAD treatment, but decreased with Nec-1 and siRIP3 treatment. Furthermore, treatment with siRIP3 did not alter the activation of caspase-8, but instead increased activation of caspase-9 and promoted endonuclease G translocation into OHC nuclei. Finally, auditory brainstem response functional measurements and morphological assessment of OHCs showed that ZVAD treatment reduces noise-induced deficits. This protective function is potentiated when combined with siRIP3 treatment. In conclusion, noise-induced OHC apoptosis and necrosis are modulated by caspases and RIP kinases, respectively. Inhibition of either pathway shifts the prevalence of OHC death to the alternative pathway.

The Journal of the Acoustical Society of America · May 2014

Temporal predictability enhances auditory detection (opens in a new tab)

Emma L. A. Lawrance, Nicol S. Harper, James E. Cooke, Jan W. H. Schnupp

Abstract

Periodic stimuli are common in natural environments and are ecologically relevant, for example, footsteps and vocalizations. This study reports a detectability enhancement for temporally cued, periodic sequences. Target noise bursts (embedded in background noise) arriving at the time points which followed on from an introductory, periodic “cue” sequence were more easily detected (by ∼1.5 dB SNR) than identical noise bursts which randomly deviated from the cued temporal pattern. Temporal predictability and corresponding neuronal “entrainment” have been widely theorized to underlie important processes in auditory scene analysis and to confer perceptual advantage. This is the first study in the auditory domain to clearly demonstrate a perceptual enhancement of temporally predictable, near-threshold stimuli.

Frontiers in Neuroscience · May 2014

A confidence metric for using neurobiological feedback in actor-critic reinforcement learning based brain-machine interfaces (opens in a new tab)

Noeline W. Prins, Justin C. Sanchez, Abhishek Prasad

Abstract

Brain-Machine Interfaces (BMIs) can be used to restore function in people living with paralysis. Current BMIs require extensive calibration that increase the set-up times and external inputs for decoder training that may be difficult to produce in paralyzed individuals. Both these factors have presented challenges in transitioning the technology from research environments to activities of daily living (ADL). For BMIs to be seamlessly used in ADL, these issues should be handled with minimal external input thus reducing the need for a technician/caregiver to calibrate the system. Reinforcement Learning (RL) based BMIs are a good tool to be used when there is no external training signal and can provide an adaptive modality to train BMI decoders. However, RL based BMIs are sensitive to the feedback provided to adapt the BMI. In actor-critic BMIs, this feedback is provided by the critic and the overall system performance is limited by the critic accuracy. In this work, we developed an adaptive BMI that could handle inaccuracies in the critic feedback in an effort to produce more accurate RL based BMIs. We developed a confidence measure, which indicated how appropriate the feedback is for updating the decoding parameters of the actor. The results show that with the new update formulation, the critic accuracy is no longer a limiting factor for the overall performance. We tested and validated the system onthree different data sets: synthetic data generated by an Izhikevich neural spiking model, synthetic data with a Gaussian noise distribution, and data collected from a non-human primate engaged in a reaching task. All results indicated that the system with the critic confidence built in always outperformed the system without the critic confidence. Results of this study suggest the potential application of the technique in developing an autonomous BMI that does not need an external signal for training or extensive calibration.