TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

IEEE Transactions on Biomedical Circuits and Systems · 2016

A Bidirectional Neural Interface IC With Chopper Stabilized BioADC Array and Charge Balanced Stimulator (opens in a new tab)

Greenwald E, So E, Wang Q, et al.

Abstract

We present a bidirectional neural interface with a 4-channel biopotential analog-to-digital converter (bioADC) and a 4-channel current-mode stimulator in 180 nm CMOS. The bioADC directly transduces microvolt biopotentials into a digital representation without a voltage-amplification stage. Each bioADC channel comprises a continuous-time first-order ∆Σ modulator with a chopper-stabilized OTA input and current feedback, followed by a second-order comb-filter decimator with programmable oversampling ratio. Each stimulator channel contains two independent digital-to-analog converters for anodic and cathodic current generation. A shared calibration circuit matches the amplitude of the anodic and cathodic currents for charge balancing. Powered from a 1.5 V supply, the analog and digital circuits in each recording channel draw on average [Formula: see text] and [Formula: see text] of supply current, respectively. The bioADCs achieve an SNR of [Formula: see text] and a SFDR of [Formula: see text] , for better than 9-b ENOB. Intracranial EEG recordings from an anesthetized rat are shown and compared to simultaneous recordings from a commercial reference system to validate performance in-vivo . Additionally, we demonstrate bidirectional operation by recording cardiac modulation induced through vagus nerve stimulation, and closed-loop control of cardiac rhythm. The micropower operation, direct digital readout, and integration of electrical stimulation circuits make this interface ideally suited for closed-loop neuromodulation applications.

Neurobiology of Aging · 2016

The impact of aging, hearing loss, and body weight on mouse hippocampal redox state, measured in brain slices using fluorescence imaging (opens in a new tab)

Stebbings KA, Choi HW, Ravindra A, et al.

ES1 & EC1System 3RPvdsExABR/DPOAE
Abstract

The relationships between oxidative stress in the hippocampus and other aging-related changes such as hearing loss, cortical thinning, or changes in body weight are not yet known. We measured the redox ratio in a number of neural structures in brain slices taken from young and aged mice. Hearing thresholds, body weight, and cortical thickness were also measured. We found striking aging-related increases in the redox ratio that were isolated to the stratum pyramidale, while such changes were not observed in thalamus or cortex. These changes were driven primarily by changes in flavin adenine dinucleotide, not nicotinamide adenine dinucleotide hydride. Multiple regression analysis suggested that neither hearing threshold nor cortical thickness independently contributed to this change in hippocampal redox ratio. However, body weight did independently contribute to predicted changes in hippocampal redox ratio. These data suggest that aging-related changes in hippocampal redox ratio are not a general reflection of overall brain oxidative state but are highly localized, while still being related to at least one marker of late aging, weight loss at the end of life.

Hearing Research · 2016

Otoacoustic emission estimates of human basilar membrane impulse response duration and cochlear filter tuning (opens in a new tab)

Raufer S, Verhulst S

Abstract

This study describes a method based on temporal suppression of click-evoked otoacoustic emissions (CEOAEs) to estimate the time course and duration of human basilar membrane impulse responses (BM IRs). This was achieved by tracing the suppression of dominant peaks in the CEOAE spectrum as a function of the temporal separation between two equal-level stimulus clicks. The relationship between the suppression pattern and underlying BM IR duration near the generation site of the CEOAE frequency was established using model simulations. To relate BM IR duration estimates to cochlear filter tuning (Q ERB ), a tuning ratio was derived from available BM IR measurements in animals. Results for 11 normal-hearing subjects yielded BM IR duration estimates of 37.4/F ms at 65 dB peSPL and 36.4/F ms at 71 dB peSPL, with F in kHz. Corresponding Q ERB estimates were 14.2F[in kHz] 0.22 at 65 dB peSPL and 13.8F[in kHz] 0.22 at 71 dB peSPL. Because the proposed temporal suppression method relies on cochlear nonlinearity, the method is applicable for stimulus levels above 30-40 dB SPL and complements existing OAE methods to assess human cochlear filter tuning.

Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · 2016

miR-431 is involved in regulating cochlear function by targeting Eya4 (opens in a new tab)

Fan Y, Zhang Y, Zhang Y, et al.

SigGenABR/DPOAE
Abstract

To understand the relationship between microRNAs and hearing loss and help clarify the causes of hereditary deafness, we studied the functions of miR-431 in cochleae. We first investigated the spatial-temporal expression profiles of miR-431 in spiral ganglion neurons (SGNs) in cochleae using real-time PCR and miRNA in situ hybridization. These studies showed that expression of miR-431 was high in SGNs in the cochleae of newborn mice, and decreased as development progressed. To test the functional effects of miR-431, we established miR-431 overexpressing transgenic (Tg) mice. Surface preparations of the cochlear basilar membrane and cochlear sections revealed no major structural differences between Tg and wild-type (Wt) mice. However, a comparison of auditory brain stem responses (ABRs) in Tg and Wt mice showed that ABR thresholds were significantly higher in Tg mice than in Wt mice. Notably, the density of SGNs was significantly lower in Tg mice than in Wt mice. We also found that the proportion of mature SGNs in cultures of primary SGNs from Tg cochleae was lower and their axons were shorter. A bioinformatics analysis predicted that the mRNA target of miR-431 was Eya4, a finding confirmed by luciferase reporter assays and western blotting. Importantly, overexpression of miR-431 in cochleae of Tg mice inhibited the translation of Eya4 mRNA, leading to a deficiency of EYA4. Thus, excessive amounts of miR-431 in cochleae of Tg mice may be the cause of sparse SGNs, which in turn could be responsible for hearing loss.

Military Medicine · 2016

Impulse Noise Injury Model (opens in a new tab)

Chan PC, Ho K, Ryan AF

Abstract

OBJECTIVES: The new Auditory 4.0 model has been developed for the assessment of auditory outcomes, expressed as temporary threshold shift (TTS) and permanent threshold shift (PTS), from exposures to impulse noise for unprotected ears, including the prediction of TTS recovery. METHODS: Auditory 4.0 is an empirical model, constructed from test data collected from chinchillas exposed to impulse noise in the laboratory. Injury outcomes are defined as TTS and PTS, and Auditory 4.0 provides the full range of TTS and PTS dose-response curves with the risk factor constructed from A-weighted sound exposure level. Human data from large weapons noise exposure was also used to guide the development of the recovery model. RESULTS: Guided by data, a 28-dBA shift was applied to the dose-response curves to account for the scaling from chinchillas to humans. Historical data from rifle noise tests were used to validate the dose-response curves. New chinchilla tests were performed to collect recovery data to construct the TTS recovery model. CONCLUSIONS: Auditory 4.0 is the only model known to date that provides the full TTS and PTS dose-response curves, including a TTS recovery model. The model shows good agreement with historical data.

Digital Collections of Colorado (Colorado State University) · 2016

The evolution of ‘earlessness’ in the true toad family (Bufonidae) (opens in a new tab)

Womack MC, L HK, L DP, et al.

Abstract

Anurans (frogs and toads) have a tympanic middle ear to transmit airborne sound from the environment to their inner ear sensory cells. Yet, many bufonid (true toad) species have independently evolved earlessness, the lack of a tympanic middle ear, despite the importance of acoustic communication in most toad mating systems. My thesis aims to determine why middle ear structures are so evolutionarily labile in the Bufonidae family by comparing development, sensory, and morphological data of eared and earless toads within a phylogenetic context. I show that the middle ear forms very late in the development of toads and takes many months past metamorphosis to become fully functional. Adult earless species are typically less sensitive to high frequency sound and more sensitive to low frequency vibrations compared to eared toads. I also find the skulls of eared and earless are very similar, indicating the middle ear is lost without change to other developmentally or genetically linked skull features. I conclude that alternative hearing pathways allow earless species to retain some hearing sensitivity, and discuss roles for development and behavior in shaping the evolutionary lability of ear structures.

International Journal of Polymer Science · 2016

Antiepileptic Effects of Lacosamide Loaded Polymers Implanted Subdurally in GAERS (opens in a new tab)

Bauquier SH, Jiang JL, Yue Z, et al.

Abstract

The current experiment investigated the ability of coaxial electrospun poly(D,L-lactide-co-glycolide) (PLGA) biodegradable polymer implants loaded with the antiepileptic drugs (AED) lacosamide to reduce seizures following implantation above the motor cortex in the Genetic Absence Epilepsy Rat from Strasbourg (GAERS). In this prospective, randomized, masked experiments, GAERS underwent surgery for implantation of skull electrodes ( n=6 ), skull electrodes and blank polymers ( n=6 ), or skull electrodes and lacosamide loaded polymers ( n=6 ). Thirty-minute electroencephalogram (EEG) recordings were started at day 7 after surgery and continued for eight weeks. The number of SWDs and mean duration of one SWD were compared week-by-week between the three groups. There was no difference in the number of SWDs between any of the groups. However, the mean duration of one SWD was significantly lower in the lacosamide polymer group for up to 7 weeks when compared to the control group ( 0.004<p<0.038 ). The mean duration of one seizure was also lower at weeks 3, 5, 6, and 7 when compared to the blank polymer group ( p = 0.016, 0.037, 0.025, and 0.025, resp.). We have demonstrated that AED loaded PLGA polymer sheets implanted on the surface of the cortex could affect seizure activity in GAERS for a sustained period.

Neural Plasticity · 2016

EEG Radiotelemetry in Small Laboratory Rodents: A Powerful State-of-the Art Approach in Neuropsychiatric, Neurodegenerative, and Epilepsy Research (opens in a new tab)

Lundt A, Wormuth C, Siwek ME, et al.

Abstract

EEG radiotelemetry plays an important role in the neurological characterization of transgenic mouse models of neuropsychiatric and neurodegenerative diseases as well as epilepsies providing valuable insights into underlying pathophysiological mechanisms and thereby facilitating the development of new translational approaches. We elaborate on the major advantages of nonrestraining EEG radiotelemetry in contrast to restraining procedures such as tethered systems or jacket systems containing recorders. Whereas a main disadvantage of the latter is their unphysiological, restraining character, telemetric EEG recording overcomes these disadvantages. It allows precise and highly sensitive measurement under various physiological and pathophysiological conditions. Here we present a detailed description of a straightforward successful, quick, and efficient technique for intraperitoneal as well as subcutaneous pouch implantation of a standard radiofrequency transmitter in mice and rats. We further present computerized 3D-stereotaxic placement of both epidural and deep intracerebral electrodes. Preoperative preparation of mice and rats, suitable anaesthesia, and postoperative treatment and pain management are described in detail. A special focus is on fields of application, technical and experimental pitfalls, and technical connections of commercially available radiotelemetry systems with other electrophysiological setups.

* Preprint: not yet peer reviewed.