TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

Journal of Neuroscience Methods · 2017

Common marmoset (Callithrix jacchus) as a primate model for behavioral neuroscience studies (opens in a new tab)

Prins NW, Pohlmeyer EA, Debnath S, et al.

Abstract

Background The common marmoset (Callithrix jacchus) has been proposed as a suitable bridge between rodents and larger primates. They have been used in several types of research including auditory, vocal, visual, pharmacological and genetics studies. However, marmosets have not been used as much for behavioral studies. New method Here we present data from training 12 adult marmosets for behavioral neuroscience studies. We discuss the husbandry, food preferences, handling, acclimation to laboratory environments and neurosurgical techniques. In this paper, we also present a custom built "scoop" and a monkey chair suitable for training of these animals. Results The animals were trained for three tasks: 4 target center-out reaching task, reaching tasks that involved controlling robot actions, and touch screen task. All animals learned the center-out reaching task within 1-2 weeks whereas learning reaching tasks controlling robot actions task took several months of behavioral training where the monkeys learned to associate robot actions with food rewards. Comparison to existing method We propose the marmoset as a novel model for behavioral neuroscience research as an alternate for larger primate models. This is due to the ease of handling, quick reproduction, available neuroanatomy, sensorimotor system similar to larger primates and humans, and a lissencephalic brain that can enable implantation of microelectrode arrays relatively easier at various cortical locations compared to larger primates. Conclusion All animals were able to learn behavioral tasks well and we present the marmosets as an alternate model for simple behavioral neuroscience tasks.

Genes, Brain and Behavior · 2017

Reduced acoustic startle response and peripheral hearing loss in the 5xFAD mouse model of Alzheimer’s disease (opens in a new tab)

O'Leary TP, Shin S, Fertan E, et al.

Abstract

Hearing dysfunction has been associated with Alzheimer's disease (AD) in humans, but there is little data on the auditory function of mouse models of AD. Furthermore, characterization of hearing ability in mouse models is needed to ensure that tests of cognition that use auditory stimuli are not confounded by hearing dysfunction. Therefore, we assessed acoustic startle response and pre-pulse inhibition in the double transgenic 5xFAD mouse model of AD from 3-4 to 16 months of age. The 5xFAD mice showed an age-related decline in acoustic startle as early as 3-4 months of age. We subsequently tested auditory brainstem response (ABR) thresholds at 4 and 13-14 months of age using tone bursts at frequencies of 2-32 kHz. The 5xFAD mice showed increased ABR thresholds for tone bursts between 8 and 32 kHz at 13-14 months of age. Finally, cochleae were extracted and basilar membranes were dissected to count hair cell loss across the cochlea. The 5xFAD mice showed significantly greater loss of both inner and outer hair cells at the apical and basal ends of the basilar membrane than wild-type mice at 15-16 months of age. These results indicate that the 5xFAD mouse model of AD shows age-related decreases in acoustic startle responses, which are at least partially due to age-related peripheral hearing loss. Therefore, we caution against the use of cognitive tests that rely on audition in 5xFAD mice over 3-4 months of age, without first confirming that performance is not confounded by hearing dysfunction.

Hearing Research · 2017

On the role of ephrinA2 in auditory function (opens in a new tab)

Ingham NJ, Steel KP, Drescher U

PA5System 3RP2.1RA16ABR/DPOAE
Abstract

Recent findings suggest that the manipulation of the EphA/ephrinA system can improve hearing threshold sensitivity in the auditory system (Yates et al., 2014). These results appear to open-up the possibility that pharmacological manipulation of this system could lead to the development of treatments to cure some types of hearing loss. As a first step towards this goal, we have performed a further series of auditory brainstem evoked potential recordings on ephrinA2 homozygous knockout mice and their wildtype littermates in order to replicate the previously reported findings. However, we found that ephrinA2 knockout mice had auditory threshold sensitivity for click and 3-42 kHz tone pip frequencies comparable to that of their wildtype littermates. Evoked potential wave amplitudes, latencies and inter-peak intervals were also comparable between ephrinA2 knockout mice and wild type control littermates. Thus in our experiments we could not replicate the findings of Yates et al. (2014). Whilst the EphA/ephrinA system may therefore play a role in the development of innervation of the cochlea and neural circuitry of the auditory brainstem, there appears to be a functional redundancy between members of this family such that loss of ephrinA2 function alone is insufficient to alter auditory function in the mouse.

Biomaterials · 2017

Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study (opens in a new tab)

Boehler C, Kleber C, Martini N, et al.

Abstract

Stable interconnection to neurons in vivo over long time-periods is critical for the success of future advanced neuroelectronic applications. The inevitable foreign body reaction towards implanted materials challenges the stability and an active intervention strategy would be desirable to treat inflammation locally. Here, we investigate whether controlled release of the anti-inflammatory drug Dexamethasone from flexible neural microelectrodes in the rat hippocampus has an impact on probe-tissue integration over 12 weeks of implantation. The drug was stored in a conducting polymer coating (PEDOT/Dex), selectively deposited on the electrode sites of neural probes, and released on weekly basis by applying a cyclic voltammetry signal in three electrode configuration in fully awake animals. Dex-functionalized probes provided stable recordings and impedance characteristics over the entire chronic study. Histological evaluation after 12 weeks of implantation revealed an overall low degree of inflammation around all flexible probes whereas electrodes exposed to active drug release protocols did have neurons closer to the electrode sites compared to controls. The combination of flexible probe technology with anti-inflammatory coatings accordingly offers a promising approach for enabling long-term stable neural interfaces.

Neural Regeneration Research · 2017

Interfacing peripheral nerve with macro-sieve electrodes following spinal cord injury (opens in a new tab)

Birenbaum NK, MacEwan MR, Ray WZ

Abstract

Macro-sieve electrodes were implanted in the sciatic nerve of five adult male Lewis rats following spinal cord injury to assess the ability of the macro-sieve electrode to interface regenerated peripheral nerve fibers post-spinal cord injury. Each spinal cord injury was performed via right lateral hemisection of the cord at the T9–10 site. Five months post-implantation, the ability of the macro-sieve electrode to interface the regenerated nerve was assessed by stimulating through the macro-sieve electrode and recording both electromyography signals and evoked muscle force from distal musculature. Electromyography measurements were recorded from the tibialis anterior and gastrocnemius muscles, while evoked muscle force measurements were recorded from the tibialis anterior, extensor digitorum longus, and gastrocnemius muscles. The macro-sieve electrode and regenerated sciatic nerve were then explanted for histological evaluation. Successful sciatic nerve regeneration across the macro-sieve electrode interface following spinal cord injury was seen in all five animals. Recorded electromyography signals and muscle force recordings obtained through macro-sieve electrode stimulation confirm the ability of the macro-sieve electrode to successfully recruit distal musculature in this injury model. Taken together, these results demonstrate the macro-sieve electrode as a viable interface for peripheral nerve stimulation in the context of spinal cord injury.

Open Scholarship Institutional Repository (Washington University in St. Louis) · 2017

Intrinsic and Extrinsic Biomechanical Factors in a Co-adaptive ECoG-based Brain Computer Interface (opens in a new tab)

Landes JC

Abstract

Paralysis, due to spinal cord injury, amyotrophic lateral sclerosis (ALS), or stroke, is the result of severed communication between the brain and the motor periphery. Brain computer interfaces (BCIs) are neuroprosthetic devices that create novel communication pathways by measuring and transforming neural activity into operational commands. State of the art BCI systems measure brain activity using penetrating electrode arrays able to record from hundreds of individual cortical neurons simultaneously. Unfortunately, these systems are highly susceptible to signal degradation which limits their efficacy to 1-2 years. However, electrocorticography (ECoG) signals recorded from the surface of the brain deliver a more competitive balance between surgical risk, long-term stability, signal bandwidth, and signal-to-noise ratio when compared to both the aforementioned intracortical systems and the more common non-invasive electroencephalography (EEG) technologies. Historically, neural signals for controlling a computer cursor or robotic arm have been mapped to extrinsic, kinematic (i.e. position or velocity) variables. Although this strategy is adequate for use in simple environments, it may not be ideal for control of real-world prosthetic devices that are subject to external and unexpected forces. When reaching for an object, the trajectory of the hand through space can be defined in either extrinsic (e.g. Cartesian) or intrinsic (e.g. joint angles, muscle forces) frames of reference. During this movement, the brain has to perform a series of sensorimotor transformations that involve solving a complex, 2nd order differential equation (i.e. musculoskeletal biomechanics) in order to determine the appropriate muscle activations. Functional neuromuscular stimulation (FNS) is a desirable BCI application because it attempts to restore motor function to paralyzed limbs through electrical excitation of muscles. Rather than applying the conventional extrinsic kinematic control signals to such a system, it may be more appropriate to map neural activity to muscle activation directly and allow the brain to develop its own transfer function. This dissertation examines the application of intrinsic decoding schemes to control an upper limb using ECoG in non-human primates. ECoG electrode arrays were chronically implanted in rhesus monkeys over sensorimotor cortex. A novel multi-joint reaching task was developed to train the subjects to control a virtual arm simulating muscle and inertial forces. Utilizing a co-adaptive algorithm (where both the brain adapts via biofeedback and the decoding algorithm adapts to improve performance), new decoding models were initially built over the course of the first 3-5 minutes of each daily experimental session and then continually adapted throughout the day. Three subjects performed the task using neural control signals mapped to 1) joint angular velocity, 2) joint torque, and 3) muscle forces of the virtual arm. Performance exceeded 97%, 93%, and 89% accuracy for the three control paradigms respectively. Neural control features in the upper gamma frequency bands (70-115 and 130-175 Hz) were found to be directionally tuned in an ordered fashion, with preferred directions varying topographically in the mediolateral direction without distinction between motor and sensory areas. Long-term stability was demonstrated by all three monkeys, which maintained performance at 42, 55, and 57 months post-implantation. These results provide insights into the capabilities of sensorimotor cortex for control of non-linear multi-joint reaching dynamics and present a first step toward design of intrinsic, force-based BCI systems suitable for long-term FNS applications.

Herpetologica · 2017

Do body wall vibrations over the lungs aid aerial hearing in salamanders? An investigation into extratympanic hearing mechanisms (opens in a new tab)

Jeffrey N. Zeyl, Carol E. Johnston

MedusaRA16BioSigABR/DPOAE
Abstract

Tympanic middle ears are key innovations in the evolution of terrestrial hearing. These structures facilitate sound transmission between air and the inner ear, across an impedance mismatch boundary. Nontympanic taxa present an opportunity to explore extratympanic hearing mechanisms, which could inform our understanding of terrestrial hearing evolution. Salamanders are useful models in this regard because they lack tympanic middle ears. Lung-based extratympanic auditory mechanisms have been demonstrated in earless anurans and are hypothesized to apply to salamanders, based on observations that the body walls overlying the lungs vibrate in response to airborne sound. We tested the hypothesis that body wall vibrations over the lungs aid aerial hearing in salamanders. We immersed the body walls and pectoral girdle below a water surface in two lunged species, Notophthalmus viridescens and Ambystoma talpoideum, predicting that this would elevate auditory thresholds (measured using evoked potentials) by inhibiting body wall motion. This submersion treatment did not significantly affect auditory sensitivities in either species. We conclude that lung-based aerial auditory pathways through the body walls are negligible or absent in the tested salamanders. Whereas lungs can potentially contribute to extratympanic hearing in small tetrapods, the extent to which these peripheral vibrations are transmitted to and detected in the ear varies across taxa. Over the course of experimentation, we discovered that modifying the positioning of both the speaker and salamander shifted thresholds (expressed relative to sound pressure) by up to 15 dB, indicating that vibration, rather than pressure, might be the appropriate acoustic measurement for aerial hearing. We discuss implications of a vibration-based auditory system for evaluating the terrestrial auditory capacities of salamanders.

Epilepsy & Behavior · 2017

The genetic audiogenic seizure hamster from Salamanca: The GASH: Sal (opens in a new tab)

Luis J. Muñoz, Melissa M. Carballosa-Gautam, Kira Yanowsky, … Dolores E. López

Abstract

The hamster has been previously described as a paroxysmal dystonia model, but our strain is currently recognized as a model of audiogenic seizures (AGS). The original first epileptic hamster appeared spontaneously at the University of Valladolid, where it was known as the GPG:Vall line, and was transferred to the University of Salamanca where a new strain was developed, named GASH:Sal. By testing auditory brainstem responses, the GASH:Sal exhibits elevated auditory thresholds that indicate a hearing impairment. Moreover, amplified fragment length polymorphism analysis distinguished genetic differences between the susceptible GASH:Sal hamster strain and the control Syrian hamsters. The GASH:Sal constitutes an experimental model of reflex epilepsy of audiogenic origin derived from an autosomal recessive disorder. Thus, the GASH:Sal exhibits generalized tonic-clonic seizures, characterized by a short latency period after auditory stimulation, followed by wild running, a convulsive phase, and finally stupor, with origin in the brainstem. The seizure profile of the GASH:Sal is similar to those exhibited by other models of inherited AGS susceptibility, which decreases after six months of age, but the proneness across generations is maintained. The GASH:Sal can be considered a reliable model of audiogenic seizures, suitable to investigate current antiepileptic pharmaceutical treatments as well as novel therapeutic drugs. This article is part of a Special Issue entitled "Genetic and Reflex Epilepsies, Audiogenic Seizures and Strains: From Experimental Models to the Clinic".

CoDAS · 2017

Hearing in Noise Test (HINT) em portugues brasileiro: criterios de interpretacao de respostas (opens in a new tab)

Melo RDC, Menezes DC, Pacifico FA, et al.

Abstract

Introduction The ability to recognize the sounds of speech enables an efficient communication. This ability must always be considered when communication disorders are evaluated. In this study, sentences of the Hearing in Noise Test (HINT), originally developed in English and adapted to Brazilian Portuguese, were used to evaluate speech recognition in silence and in the presence of noise. Although this test can be an important clinical tool, it is noticed that it has not been used in audiological clinical practice in Brazil. One possible reason is the lack of standardization of some aspects of the test, including the methods adopted to analyze the patient's answers. Purpose The aim of this study was to analyze different judgment criteria of individuals' answers during sentence recognition thresholds measurement using the HINT in Brazilian Portuguese. Methods The study was conducted with 30 young adults (three groups of 10 people), between 18 and 25 years old, of both genders, with normal hearing. HINT sentences were adapted to Brazilian Portuguese and speech recognition thresholds were determined in the presence of noise by using three judgment criteria published in Brazilian literature. A single variation analysis was performed to compare the average threshold between the three groups. The maximum error probability to reject the null hypothesis was 5%. Results The mean and standard deviations of thresholds, respectively, were: 59.90 ± 1.43 dB SPL; 59.60 ± 0.53 dB SPL and 59.95 ± 0.6 dB SPL. There was no statistically significant difference between the means (F = 0.398; p> 0.05). Conclusion Regardless the judging criteria used, results obtained in all groups were equivalent.

* Preprint: not yet peer reviewed.