, Abstr: PS-465 · 2018
Publications using TDT
More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.
10,510 papers
Fechner Day · 2018
Searching for a measure of auditory temporal resolution: preliminary data (opens in a new tab)
Animal Behaviour · 2018
Do juvenile rats use specific ultrasonic calls to coordinate their social play? (opens in a new tab)
Acta Hydrobiologica Sinica · 2018
THRESHOLDS FOR THE HEARING OF MARBLED ROCKFISH SEBASTICUS MARMORATUS (opens in a new tab)
Journal of Experimental Biology · 2018
Sensitive high frequency hearing in earless and partially eared harlequin frogs (Atelopus) (opens in a new tab)
Abstract
Harlequin frogs, genus Atelopus, communicate at high frequencies despite most species lacking a complete tympanic middle ear that facilitates high frequency hearing in most anurans and other tetrapods. Here we test whether Atelopus are better at sensing high frequency acoustic sound compared to other eared and earless species in the Bufonidae family, determine whether middle ear variation within Atelopus affects hearing sensitivity, and test potential hearing mechanisms in Atelopus. We determine that at high frequencies (2000–4000 Hz) Atelopus are 10–34 dB more sensitive than other earless bufonids but are relatively insensitive to mid-range frequencies (900–1500 Hz) compared to eared bufonids. Hearing among Atelopus species is fairly consistent, evidence that the partial middle ears present in a subset of Atelopus species do not convey a substantial hearing advantage. We further demonstrate that Atelopus hearing is not likely facilitated by vibration of the skin overlying the normal tympanic membrane region or the body lung wall, leaving the extratympanic hearing pathways in Atelopus enigmatic. Together these results show Atelopus have sensitive high frequency hearing without the aid of a tympanic middle ear and prompt further study of extratympanic hearing mechanisms in anurans.
The Journal of the Acoustical Society of America · 2018
Effects of vibratory pile driver noise on echolocation and vigilance in bottlenose dolphins (Tursiops truncatus) (opens in a new tab)
Abstract
Vibratory pile drivers, used for marine construction, can produce sustained, high sound pressure levels (SPLs) in areas that overlap with dolphin habitats. Dolphins rely on echolocation for navigation, detecting predators and prey, and to coordinate group behavior. This study examined the effects of vibratory pile driver noise on dolphin sustained target detection capabilities through echolocation. Five dolphins were required to scan their enclosure and indicate the occurrences of phantom echoes during five different source levels of vibratory pile driver playback sound (no-playback control, 110, 120, 130, and 140 dB re 1 μPa). Three of the dolphins demonstrated a significant decrease in target detection performance at 140 dB playback level that was associated with an almost complete secession of echolocation activity. The performance of two dolphins was not affected. All dolphins rapidly returned to baseline levels of target detection performance by their second replication. However, an increased number of clicks was produced at the highest playback SPL. The data suggest that the decrease in vigilant behavior was due to the vibratory pile driver noise distracting the dolphins and decreasing their motivation to perform the task.
NeuroImage · 2018
Transcranial alternating current stimulation with speech envelopes modulates speech comprehension (opens in a new tab)
Abstract
Cortical entrainment of the auditory cortex to the broadband temporal envelope of a speech signal is crucial for speech comprehension. Entrainment results in phases of high and low neural excitability, which structure and decode the incoming speech signal. Entrainment to speech is strongest in the theta frequency range (4–8 Hz), the average frequency of the speech envelope. If a speech signal is degraded, entrainment to the speech envelope is weaker and speech intelligibility declines. Besides perceptually evoked cortical entrainment, transcranial alternating current stimulation (tACS) entrains neural oscillations by applying an electric signal to the brain. Accordingly, tACS-induced entrainment in auditory cortex has been shown to improve auditory perception. The aim of the current study was to modulate speech intelligibility externally by means of tACS such that the electric current corresponds to the envelope of the presented speech stream (i.e., envelope-tACS). Participants performed the Oldenburg sentence test with sentences presented in noise in combination with envelope-tACS. Critically, tACS was induced at time lags of 0 to 250 ms in 50-ms steps relative to sentence onset (auditory stimuli were simultaneous to or preceded tACS). We performed single-subject sinusoidal, linear, and quadratic fits to the sentence comprehension performance across the time lags. We could show that the sinusoidal fit described the modulation of sentence comprehension best. Importantly, the average frequency of the sinusoidal fit was 5.12 Hz, corresponding to the peaks of the amplitude spectrum of the stimulated envelopes. This finding was supported by a significant 5-Hz peak in the average power spectrum of individual performance time series. Altogether, envelope tACS modulates intelligibility of speech in noise, presumably by enhancing and disrupting (time lag with in-or out-of-phase stimulation, respectively) cortical entrainment to the speech envelope in auditory cortex.
European Journal of Neuroscience · 2018
Auditory motion does not modulate spiking activity in the middle temporal and medial superior temporal visual areas (opens in a new tab)
Abstract
The integration of multiple sensory modalities is a key aspect of brain function, allowing animals to take advantage of concurrent sources of information to make more accurate perceptual judgments. For many years, multisensory integration in the cerebral cortex was deemed to occur only in high-level “polysensory” association areas. However, more recent studies have suggested that cross-modal stimulation can also influence neural activity in areas traditionally considered to be unimodal. In particular, several human neuroimaging studies have reported that extrastriate areas involved in visual motion perception are also activated by auditory motion, and may integrate audio-visual motion cues. However, the exact nature and extent of the effects of auditory motion on the visual cortex have not been studied at the single neuron level. We recorded the spiking activity of neurons in the middle temporal (MT) and medial superior temporal (MST) areas of anesthetized marmoset monkeys upon presentation of unimodal stimuli (moving auditory or visual patterns), as well as bimodal stimuli (concurrent audio-visual motion). Despite robust, direction selective responses to visual motion, none of the sampled neurons responded to auditory motion stimuli. Moreover, concurrent moving auditory stimuli had no significant effect on the ability of single MT and MST neurons, or populations of simultaneously recorded neurons, to discriminate the direction of motion of visual stimuli (moving random dot patterns with varying levels of motion noise). Our findings do not support the hypothesis that direct interactions between MT, MST and areas low in the hierarchy of auditory areas underlie audiovisual motion integration.
Journal of Neuroscience Methods · 2018
Acoustic calibration in an echoic environment (opens in a new tab)
Abstract
Background : The sound fed to a loudspeaker may significantly differ from that reaching the ear of the listener. The transformation from one to the other consists of spectral distortions with strong dependence on the relative locations of the speaker and the listener as well as on the geometry of the environment. With the increased importance of research in awake, freely-moving animals in large arenas, it becomes important to understand how animal location influences the corresponding spectral distortions. New Method : We describe a full calibration pipeline that includes spatial sampling and estimation of the spectral distortions. We estimated the impulse responses of the environment using Golay complementary sequences. Using those sequences, we also describe an acoustic 3D localization method for freely moving animals. Results : In our arena, the impulse responses are dominated by a small number of strong reflections. We use this understanding to provide guidelines for designing the geometry of the environment as well as the presented sounds, in order to provide more uniform sound levels throughout the environment. Our 3D localization method achieves a 1 cm precision through the utilization of sound cues only. Comparison with Existing Methods : To our knowledge, this is the first description of a large-scale acoustic calibration pipeline with acoustic localization for neuroscience studies. Conclusions : Principled sampling of large arena allows for better design and control of the acoustic information provided to freely-moving animals.
Cell · 2018
A Genetically Encoded Fluorescent Sensor Enables Rapid and Specific Detection of Dopamine in Flies, Fish, and Mice (opens in a new tab)
Abstract
Dopamine (DA) is a central monoamine neurotransmitter involved in many physiological and pathological processes. A longstanding yet largely unmet goal is to measure DA changes reliably and specifically with high spatiotemporal precision, particularly in animals executing complex behaviors. Here we report the development of novel genetically-encoded GPCR-Activation-Based-DA (GRAB DA ) sensors that enable these measurements. In response to extracellular DA rises, GRAB DA sensors exhibit large fluorescence increases (ΔF/F 0 ∼90%) with sub-second kinetics, nanomolar to sub-micromolar affinities, and excellent molecular specificity. Importantly, GRABDA sensors can resolve a single-electrical-stimulus evoked DA release in mouse brain slices, and detect endogenous DA release in the intact brains of flies, fish, and mice. In freely-behaving mice, GRABDA sensors readily report optogenetically-elicited nigrostriatal DA release and depict dynamic mesoaccumbens DA changes during Pavlovian conditioning or during sexual behaviors. Thus, GRAB DA sensors enable spatiotemporal precise measurements of DA dynamics in a variety of model organisms while exhibiting complex behaviors.
Acoustical Science and Technology · 2018
Light-synchronized tapping task as an objective method for estimating auditory detection threshold (opens in a new tab)
Abstract
The accuracy of synchronous tapping with a sequence of fixed-interval light flashes (lightsynchronized tapping, LST) is impaired by the presence of a sound sequence depending on its temporal relationship with the light flashes.The present study tested the possibility that the LST task can be used as an objective method of estimating auditory detection thresholds without requiring the listener to report directly his/her sensation as in standard audiometry.The experiment used tone bursts as distractor sequences and varied the frequency and level of the tones.The tone level had a statistically significant effect on the distraction level, but the effect of frequency was not significant.Significant distraction was observed for a tone level of, on average, as low as 15 dB above the detection threshold.In other words, once the lowest tone level of the distraction effect is identified, one can expect that the participant's detection threshold would lie at around 15 dB below the level, regardless of the frequency.The results indicate that in principle, the LST task could be used to estimate auditory detection thresholds, although the reliability of the threshold estimation still has to be improved for it to be applicable to audiometry.
Infoscience (Ecole Polytechnique Federale de Lausanne) · 2018
Designing sensory feedback approaches for restoring touch and position feedback in upper limb amputees (opens in a new tab)
Abstract
Upper limb amputation disrupts most daily activities and reduces the quality of life of affected individuals. Building a suitable prosthetic limb, which can restore at least some of the lost capabilities, is a goal which has been pursued for centuries. In the last few decades, our rapidly expanding understanding of the human nervous system has unlocked impressive advances in artificial limbs. Today, commercial prosthetic hands can be controlled intuitively through voluntary muscle contractions. Nevertheless, despite leaps in the quality of modern prostheses, sensory feedback remains one of the major omissions, forcing users to rely on vision to accomplish basic tasks, such as holding a plastic cup without crushing it. Several sensory feedback strategies have recently been developed to restore tactile and proprioceptive feedback to amputees, demonstrating benefits in important areas, such as higher functional performance and increases in the sense of prosthesis ownership. Sensory feedback strategies can be distinguished based on whether the sensation they restore matches the quality (homologous feedback) or the location (somatotopic feedback) of the original sensation. Despite promising results, somatotopic tactile feedback strategies often result in unnatural sensations (e.g. electricity). Furthermore, restoration of more than a single sensory modality is rarely reported, despite being necessary to create artificial limbs capable of delivering realistic sensorimotor experiences during use. In this work, I proposed three novel and complementary strategies to improve sensory feedback restoration in upper limb prostheses. I begin by describing a non-invasive transcutaneous electrical nerve stimulation (TENS) approach aimed at restoring somatotopic tactile sensations, which is potentially applicable to all trans-radial amputees. This stimulation strategy was shown to lead to high performance during functional tasks, and compared favorably to more invasive approaches, despite a few key differences. Considering that there is no such thing as a one-size-fits-all solution for amputees, I concluded that TENS represents a viable alternative to invasive systems, especially in cases where an implant is not possible or desirable. In the second part, I proposed a sensory substitution approach to multimodal feedback, which delivered somatotopic tactile and remapped proprioceptive feedback simultaneously. This stimulation strategy relied entirely on implantable electrodes, simplifying the overall system by delivering two streams of sensory information with the same device. Using this feedback system, two amputees were able to perform interesting functional tasks, such as understanding the size and compliance of various objects, with high accuracy. Finally, I proposed a novel stimulation technique for sensory feedback designed to desynchronize induced neural activity during electrical stimulation, leading to more biomimetic patterns of activity. I discussed how this strategy could be combined with the results obtained in a recent study which I contributed to, in which we demonstrated that a model based encoding strategy resulted in more natural sensations of touch. This thesis provides evidence that advances in electrical stimulation protocols can lead to more capable prosthetic limbs. These new methods enable the delivery of multimodal, biomimetic sensory feedback and will help bridge the gap between scientific discovery and clinical translation.
The Proceedings of Mechanical Engineering Congress Japan · 2018
Intraoperative measurement of cochlear microphonic (CM) caused by direct excitation of ossicles with transducer (opens in a new tab)
Abstract
Cochlear microphonic (CM) is known to faithfully correspond to the frequency and level of sound pressure applied to the cochlea. If the CM is measured and compared before and after the treatment during an otologic surgery, the improvement of hearing of patients can be evaluated, and the risk of reoperation can be decreased. However, in some operations the sound transmission mechanism of the middle ear is temporarily disabled, and sound pressure cannot be applied to the cochlea with a speaker. In this study, a system for measuring the CM during surgery was constructed. The system consists of a vibration probe, electrodes, amplifier, and controller. The ossicles are vibrated by the vibration probe instead of sound from speaker, and the CM signals generated by the vibration are measured. The CM amplitude increased in proportion to the input voltage to the vibrator in the vibration probe as is the case with sound stimulation. This result suggests that the intraoperative assessment of improvement of hearing is possible by using the vibration probe.
Neurobiology of Disease · 2018
Chemically activated luminopsins allow optogenetic inhibition of distributed nodes in an epileptic network for non-invasive and multi-site suppression of seizure activity (opens in a new tab)
Abstract
Although optogenetic techniques have proven to be invaluable for manipulating and understanding complex neural dynamics over the past decade, they still face practical and translational challenges in targeting networks involving multiple, large, or difficult-to-illuminate areas of the brain. We utilized inhibitory luminopsins to simultaneously inhibit the dentate gyrus and anterior nucleus of the thalamus of the rat brain in a hardware-independent and cell-type specific manner. This approach was more effective at suppressing behavioral seizures than inhibition of the individual structures in a rat model of epilepsy. In addition to elucidating mechanisms of seizure suppression never directly demonstrated before, this work also illustrates how precise multi-focal control of pathological circuits can be advantageous for the treatment and understanding of disorders involving broad neural circuits such as epilepsy.
Journal of Neurophysiology · 2018
Breathing above the brain stem: volitional control and attentional modulation in humans (opens in a new tab)
Abstract
Whereas the neurophysiology of respiration has traditionally focused on automatic brain stem processes, higher brain mechanisms underlying the cognitive aspects of breathing are gaining increasing interest. Therapeutic techniques have used conscious control and awareness of breathing for millennia with little understanding of the mechanisms underlying their efficacy. Using direct intracranial recordings in humans, we correlated cortical and limbic neuronal activity as measured by the intracranial electroencephalogram (iEEG) with the breathing cycle. We show this to be the direct result of neuronal activity, as demonstrated by both the specificity of the finding to the cortical gray matter and the tracking of breath by the gamma-band (40–150 Hz) envelope in these structures. We extend prior observations by showing the iEEG signal to track the breathing cycle across a widespread network of cortical and limbic structures. We further demonstrate a sensitivity of this tracking to cognitive factors by using tasks adapted from cognitive behavioral therapy and meditative practice. Specifically, volitional control and awareness of breathing engage distinct but overlapping brain circuits. During volitionally paced breathing, iEEG-breath coherence increases in a frontotemporal-insular network, and during attention to breathing, we demonstrate increased coherence in the anterior cingulate, premotor, insular, and hippocampal cortices. Our findings suggest that breathing can act as an organizing hierarchical principle for neuronal oscillations throughout the brain and detail mechanisms of how cognitive factors impact otherwise automatic neuronal processes during interoceptive attention. NEW & NOTEWORTHY Whereas the link between breathing and brain activity has a long history of application to therapy, its neurophysiology remains unexplored. Using intracranial recordings in humans, we show neuronal activity to track the breathing cycle throughout widespread cortical/limbic sites. Volitional pacing of the breath engages frontotemporal-insular cortices, whereas attention to automatic breathing modulates the cingulate cortex. Our findings imply a fundamental role of breathing-related oscillations in driving neuronal activity and provide insight into the neuronal mechanisms of interoceptive attention.
Hearing Research · 2018
Effects of noise overexposure on tone detection in noise in nonhuman primates (opens in a new tab)
Abstract
This report explores the consequences of acoustic overexposures on hearing in noisy environments for two macaque monkeys trained to perform a reaction time detection task using a Go/No-Go lever release paradigm. Behavioral and non-invasive physiological assessments were obtained before and after narrowband noise exposure. Physiological measurements showed elevated auditory brainstem response (ABR) thresholds and absent distortion product otoacoustic emissions (DPOAEs) post-exposure relative to pre-exposure. Audiograms revealed frequency specific increases in tone detection thresholds, with the greatest increases at the exposure band frequency and higher. Masked detection was affected in a similar frequency specific manner: threshold shift rates (change of masked threshold per dB increase in noise level) were lower than pre-exposure values at frequencies higher than the exposure band. Detection thresholds in sinusoidally amplitude modulated (SAM) noise post-exposure showed no difference from those in unmodulated noise, whereas pre-exposure masked detection thresholds were lower in the presence of SAM noise compared to unmodulated noise. These frequency-dependent results were correlated with cochlear histopathological changes in monkeys that underwent similar noise exposure. These results reveal that behavioral and physiological effects of noise exposure in macaques are similar to those seen in humans and provide preliminary information on the relationship between noise exposure, cochlear pathology and perceptual changes in hearing within individual subjects.
Brain Research · 2018
Gap-induced reductions of evoked potentials in the auditory cortex: A possible objective marker for the presence of tinnitus in animals (opens in a new tab)
Abstract
Animal models of tinnitus are essential for determining the underlying mechanisms and testing pharmacotherapies. However, there is doubt over the validity of current behavioural methods for detecting tinnitus. Here, we applied a stimulus paradigm widely used in a behavioural test (gap-induced inhibition of the acoustic startle reflex GPIAS) whilst recording from the auditory cortex, and showed neural response changes that mirror those found in the behavioural tests. We implanted guinea pigs (GPs) with electrocorticographic (ECoG) arrays and recorded baseline auditory cortical responses to a startling stimulus. When a gap was inserted in otherwise continuous background noise prior to the startling stimulus, there was a clear reduction in the subsequent evoked response (termed gap-induced reductions in evoked potentials; GIREP), suggestive of a neural analogue of the GPIAS test. We then unilaterally exposed guinea pigs to narrowband noise (left ear; 8-10 kHz; 1 h) at one of two different sound levels - either 105 dB SPL or 120 dB SPL - and recorded the same responses seven-to-ten weeks following the noise exposure. Significant deficits in GIREP were observed for all areas of the auditory cortex (AC) in the 120 dB-exposed GPs, but not in the 105 dB-exposed GPs. These deficits could not simply be accounted for by changes in response amplitudes. Furthermore, in the contralateral (right) caudal AC we observed a significant increase in evoked potential amplitudes across narrowband background frequencies in both 105 dB and 120 dB-exposed GPs. Taken in the context of the large body of literature that has used the behavioural test as a demonstration of the presence of tinnitus, these results are suggestive of objective neural correlates of the presence of noise-induced tinnitus and hyperacusis.
Journal of Controlled Release · 2018
The feasibility of an encapsulated cell approach in an animal deafness model (opens in a new tab)
Abstract
For patients with profound hearing loss a cochlear implant (CI) is the only treatment today. The function of a CI depends in part of the function and survival of the remaining spiral ganglion neurons (SGN). It is well known from animal models that inner ear infusion of neurotrophic factors prevents SGN degeneration and maintains electrical responsiveness in deafened animals. The purpose with this study was to investigate the effects of a novel encapsulated cell (EC) device releasing neurotrophic factors in the deafened guinea pig. The results showed that an EC device releasing glial cell line-derived neurotrophic factor (GDNF) or brain-derived neurotrophic factor (BDNF) implanted for four weeks in deafened guinea pigs significantly preserved the SGNs and maintained their electrical responsiveness. There was a significant difference between BDNF and GDNF in favour of GDNF. This study, demonstrating positive structural and functional effects in the deafened inner ear, suggests that an implanted EC device releasing biologically protective substances offers a feasible approach for treating progressive hearing impairment.
Trends in Hearing · 2018
Interaural Time-Difference Discrimination as a Measure of Place of Stimulation for Cochlear-Implant Users With Single-Sided Deafness (opens in a new tab)
Abstract
Current clinical practice in programming a cochlear implant (CI) for individuals with single-sided deafness (SSD) is to maximize the transmission of speech information via the implant, with the implicit assumption that this will also result in improved spatial-hearing abilities. However, binaural sensitivity is reduced by interaural place-of-stimulation mismatch, a likely occurrence with a standard CI frequency-to-electrode allocation table (FAT). As a step toward reducing interaural mismatch, this study investigated whether a test of interaural-time-difference (ITD) discrimination could be used to estimate the acoustic frequency yielding the best place match for a given CI electrode. ITD-discrimination performance was measured by presenting 300-ms bursts of 100-pulses-per-second electrical pulse trains to a single CI electrode and band-limited pulse trains with variable carrier frequencies to the acoustic ear. Listeners discriminated between two reference intervals (four bursts each with constant ITD) and a moving target interval (four bursts with variable ITD). For 17 out of the 26 electrodes tested across eight listeners, the function describing the relationship between ITD-discrimination performance and carrier frequency had a discernable peak where listeners achieved 70% to 100% performance. On average, this peak occurred 1.15 octaves above the CI manufacturer’s default FAT. ITD discrimination shows promise as a method of estimating the cochlear place of stimulation for a given electrode, thereby providing information to optimize the FAT for SSD-CI listeners.
eNeuro · 2018
Auditory Brainstem Responses to Continuous Natural Speech in Human Listeners (opens in a new tab)
Abstract
Speech is an ecologically essential signal, whose processing crucially involves the subcortical nuclei of the auditory brainstem, but there are few experimental options for studying these early responses in human listeners under natural conditions. While encoding of continuous natural speech has been successfully probed in the cortex with neurophysiological tools such as electroencephalography (EEG) and magnetoencephalography, the rapidity of subcortical response components combined with unfavorable signal-to-noise ratios signal-to-noise ratio has prevented application of those methods to the brainstem. Instead, experiments have used thousands of repetitions of simple stimuli such as clicks, tone-bursts, or brief spoken syllables, with deviations from those paradigms leading to ambiguity in the neural origins of measured responses. In this study we developed and tested a new way to measure the auditory brainstem response (ABR) to ongoing, naturally uttered speech, using EEG to record from human listeners. We found a high degree of morphological similarity between the speech-derived ABRs and the standard click-evoked ABR, in particular, a preserved Wave V, the most prominent voltage peak in the standard click-evoked ABR. Because this method yields distinct peaks that recapitulate the canonical ABR, at latencies too short to originate from the cortex, the responses measured can be unambiguously determined to be subcortical in origin. The use of naturally uttered speech to measure the ABR allows the design of engaging behavioral tasks, facilitating new investigations of the potential effects of cognitive processes like language and attention on brainstem processing.
