Menu

EEG/ECoG/EMG publications

EEG, ECoG and EMG recordings made with TDT systems.

PLOS ONE · Mar 2021

Steady state evoked potential (SSEP) responses in the primary and secondary somatosensory cortices of anesthetized cats: Nonlinearity characterized by harmonic and intermodulation frequencies (opens in a new tab)

Yota Kawashima, Rannee Li, Spencer Chin-Yu Chen, … Naotsugu Tsuchiya

Abstract

When presented with an oscillatory sensory input at a particular frequency, F [Hz], neural systems respond with the corresponding frequency, f [Hz], and its multiples. When the input includes two frequencies ( F1 and F2 ) and they are nonlinearly integrated in the system, responses at intermodulation frequencies (i.e., n1 * f1 + n2 * f2 [Hz], where n1 and n2 are non-zero integers) emerge. Utilizing these properties, the steady state evoked potential (SSEP) paradigm allows us to characterize linear and nonlinear neural computation performed in cortical neurocircuitry. Here, we analyzed the steady state evoked local field potentials (LFPs) recorded from the primary (S1) and secondary (S2) somatosensory cortex of anesthetized cats (maintained with alfaxalone) while we presented slow ( F1 = 23Hz) and fast ( F2 = 200Hz) somatosensory vibration to the contralateral paw pads and digits. Over 9 experimental sessions, we recorded LFPs from N = 1620 and N = 1008 bipolar-referenced sites in S1 and S2 using electrode arrays. Power spectral analyses revealed strong responses at 1) the fundamental ( f1 , f2 ), 2) its harmonic, 3) the intermodulation frequencies, and 4) broadband frequencies (50-150Hz). To compare the computational architecture in S1 and S2, we employed simple computational modeling. Our modeling results necessitate nonlinear computation to explain SSEP in S2 more than S1. Combined with our current analysis of LFPs, our paradigm offers a rare opportunity to constrain the computational architecture of hierarchical organization of S1 and S2 and to reveal how a large-scale SSEP can emerge from local neural population activities.

Frontiers in Neuroscience · Feb 2021

Rapid and Low Cost Manufacturing of Cuff Electrodes (opens in a new tab)

Matthew T. Flavin, Marek A. Paul, Alexander S. Lim, … Jongyoon Han

Abstract

For many peripheral neuro-modulation applications, the cuff electrode has become a preferred technology for delivering electrical current into targeted volumes of tissue. While basic cuffs with low spatial selectivity, having longitudinally arranged contacts, can be produced from relatively straightforward processes, the fabrication of more complex electrode configurations typically requires iterative design and clean-room fabrication with skilled technicians. Although facile methods for fabricating cuff electrodes exist, their inconsistent products have limited their adoption for rapid manufacturing. In this article, we report a fast, low-cost fabrication process for patterning of electrode contacts in an implantable peripheral nerve cuff. Using a laser cutter as we have prescribed, the designer can render precise contact geometries that are consistent between batches. This method is enabled by the use of silicone/carbon black (CB) composite electrodes, which integrate with the patterned surface of its substrate—tubular silicone insulation. The size and features of its products can be adapted to fit a wide range of nerve diameters and applications. In this study, we specifically documented the manufacturing and evaluation of circumpolar cuffs with radial arrays of three contacts for acute implantation on the rat sciatic nerve. As part of this method, we also detail protocols for verification—electrochemical characterization—and validation—electrophysiological evaluation—of implantable cuff electrodes. Applied to our circumpolar cuff electrode, we report favorable electrical characteristics. In addition, we report that it reproduces expected electrophysiological behaviors described in prior literature. No specialized equipment or fabrication experience was required in our production, and we encountered negligible costs relative to commercially available solutions. Since, as we demonstrate, this process generates consistent and precise electrode geometries, we propose that it has strong merits for use in rapid manufacturing.

eneuro · 2021

Neural Correlates of Vocal Auditory Feedback Processing: Unique Insights from Electrocorticography Recordings in a Human Cochlear Implant User (opens in a new tab)

Charles A. Miller, Roozbeh Behroozmand, Christine P. Etler, … Jeremy D. W. Greenlee

Abstract

There is considerable interest in understanding cortical processing and the function of top-down and bottom-up human neural circuits that control speech production. Research efforts to investigate these circuits are aided by analysis of spectro-temporal response characteristics of neural activity recorded by electrocorticography (ECoG). Further, cortical processing may be altered in the case of hearing-impaired cochlear implant (CI) users, as electric excitation of the auditory nerve creates a markedly different neural code for speech compared with that of the functionally intact hearing system. Studies of cortical activity in CI users typically record scalp potentials and are hampered by stimulus artifact contamination and by spatiotemporal filtering imposed by the skull. We present a unique case of a CI user who required direct recordings from the cortical surface using subdural electrodes implanted for epilepsy assessment. Using experimental conditions where the subject vocalized in the presence (CIs ON) or absence (CIs OFF) of auditory feedback, or listened to playback of self-vocalizations without production, we observed ECoG activity primarily in γ (32-70 Hz) and high γ (70-150 Hz) bands at focal regions on the lateral surface of the superior temporal gyrus (STG). High γ band responses differed in their amplitudes across conditions and cortical sites, possibly reflecting different rates of stimulus presentation and differing levels of neural adaptation. STG γ responses to playback and vocalization with auditory feedback were not different from responses to vocalization without feedback, indicating this activity reflects not only auditory, but also attentional, efference-copy, and sensorimotor processing during speech production.

Frontiers in Neuroscience · Oct 2019

uECoG Recordings Through a Thinned Skull (opens in a new tab)

Sarah K. Brodnick, Jared P. Ness, Thomas J. Richner, … Justin C. Williams

Abstract

The studies described in this paper for the first time characterize the acute and chronic performance of optically transparent thin-film micro-electrocorticography (μECoG) grids implanted on a thinned skull as both an electrophysiological complement to existing thinned skull preparation for optical recordings/manipulations, and a less invasive alternative to epidural or subdurally placed μECoG arrays. In a longitudinal chronic study, μECoG grids placed on top of a thinned skull maintain impedances comparable to epidurally placed μECoG grids that are stable for periods of at least 1 month. Optogenetic activation of cortex is also reliably demonstrated through the optically transparent μECoG grids acutely placed on the thinned skull. Finally, spatially distinct electrophysiological recordings were evident on μECoG electrodes placed on a thinned skull separated by 500-750 μm, as assessed by stimulation evoked responses using optogenetic activation of cortex as well as invasive and epidermal stimulation of the sciatic and median nerve at chronic time points. Neural signals were collected through a thinned skull in mice and rats, demonstrating potential utility in neuroscience research applications such as in vivo imaging and optogenetics.

bioRxiv · Sep 2019

Spreading depolarization and repolarization during cardiac arrest as an ultra-early marker of neurological recovery in a preclinical model (opens in a new tab)

Robert H. Wilson, Christian Crouzet, Donald E. Lee, … Yama Akbari

Abstract

Spreading depolarization (SD) accompanies numerous neurological conditions, including migraine, stroke, and traumatic brain injury. There is significant interest in understanding the relationship between SD and neuronal injury. However, characteristics underlying SD and repolarization (RP) induced by global cerebral ischemia (e.g., cardiac arrest (CA)) and reperfusion are not well understood. Quantifying features of SD and RP during CA and cardiopulmonary resuscitation (CPR) may provide important metrics for diagnosis and prognosis of neurological injury from hypoxia-ischemia. We characterized SD and RP in a rodent model of asphyxial CA+CPR using a multimodal platform including electrocorticography (ECoG) and optical imaging. We detected SD and RP by (1) alternating current (AC), (2) direct current (DC), and (3) optical imaging of spreading ischemia, spreading edema, and vasoconstriction. Earlier SD (r=−0.80; p<0.001) and earlier RP (r=−0.71, p<0.001) were associated with better neurological recovery after 24hrs. SD+RP onset times predicted good vs poor neurological recovery with 82% sensitivity and 91% specificity. To our knowledge, this is the first preclinical study to link SD and RP characteristics with neurological recovery post-CA. These data suggest that SD and RP may be ultra-early, real-time prognostic markers of post-CA outcome, meriting further investigation into translational implications during global cerebral ischemia.

eneuro · Mar 2019

Signature Patterns for Top-Down and Bottom-Up Information Processing via Cross-Frequency Coupling in Macaque Auditory Cortex (opens in a new tab)

Christian D. Márton, Makoto Fukushima, Corrie R. Camalier, … Bruno B. Averbeck

Abstract

Predictive coding is a theoretical framework that provides a functional interpretation of top-down and bottom-up interactions in sensory processing. The theory suggests there are differences in message passing up versus down the cortical hierarchy. These differences result from the linear feedforward of prediction errors, and the nonlinear feedback of predictions. This implies that cross-frequency interactions should predominate top-down. But it remains unknown whether these differences are expressed in cross-frequency interactions in the brain. Here we examined bidirectional cross-frequency coupling across four sectors of the auditory hierarchy in the macaque. We computed two measures of cross-frequency coupling, phase–amplitude coupling (PAC) and amplitude–amplitude coupling (AAC). Our findings revealed distinct patterns for bottom-up and top-down information processing among cross-frequency interactions. Both top-down and bottom-up interactions made prominent use of low frequencies: low-to-low-frequency (theta, alpha, beta) and low-frequency-to-high- gamma couplings were predominant top-down, while low-frequency-to-low-gamma couplings were predominant bottom-up. These patterns were largely preserved across coupling types (PAC and AAC) and across stimulus types (natural and synthetic auditory stimuli), suggesting that they are a general feature of information processing in auditory cortex. Our findings suggest the modulatory effect of low frequencies on gamma-rhythms in distant regions is important for bidirectional information transfer. The finding of low-frequency-to-low-gamma interactions in the bottom-up direction suggest that nonlinearities may also play a role in feedforward message passing. Altogether, the patterns of cross-frequency interaction we observed across the auditory hierarchy are largely consistent with the predictive coding framework.

Materials · Dec 2018

Glassy Carbon Electrocorticography Electrodes on Ultra-Thin and Finger-Like Polyimide Substrate: Performance Evaluation Based on Different Electrode Diameters (opens in a new tab)

Maria Vomero, Elena Zucchini, Emanuela Delfino, … Thomas Stieglitz

Abstract

Glassy carbon (GC) has high potential to serve as a biomaterial in neural applications because it is biocompatible, electrochemically inert and can be incorporated in polyimide-based implantable devices. Miniaturization and applicability of GC is, however, thought to be partially limited by its electrical conductivity. For this study, ultra-conformable polyimide-based electrocorticography (ECoG) devices with different-diameter GC electrodes were fabricated and tested in vitro and in rat models. For achieving conformability to the rat brain, polyimide was patterned in a finger-like shape and its thickness was set to 8 µm. To investigate different electrode sizes, each ECoG device was assigned electrodes with diameters of 50, 100, 200 and 300 µm. They were electrochemically characterized and subjected to 10 million biphasic pulses—for achieving a steady-state—and to X-ray photoelectron spectroscopy, for examining their elemental composition. The electrodes were then implanted epidurally to evaluate the ability of each diameter to detect neural activity. Results show that their performance at low frequencies (up to 300 Hz) depends on the distance from the signal source rather than on the electrode diameter, while at high frequencies (above 200 Hz) small electrodes have higher background noises than large ones, unless they are coated with poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS).

Micromachines · Oct 2018

A Bidirectional Neuromodulation Technology for Nerve Recording and Stimulation (opens in a new tab)

Jian Xu, Hongsun Guo, Anh Tuan Nguyen, … Zhi Yang

Abstract

Electrical nerve recording and stimulation technologies are critically needed to monitor and modulate nerve activity to treat a variety of neurological diseases. However, current neuromodulation technologies presented in the literature or commercially available products cannot support simultaneous recording and stimulation on the same nerve. To solve this problem, a new bidirectional neuromodulation system-on-chip (SoC) is proposed in this paper, which includes a frequency-shaping neural recorder and a fully integrated neural stimulator with charge balancing capability. In addition, auxiliary circuits consisting of power management and data transmission circuits are designed to provide the necessary power supply for the SoC and the bidirectional data communication between the SoC and an external computer via a universal serial bus (USB) interface, respectively. To achieve sufficient low input noise for sensing nerve activity at a sub-10 μ V range, several noise reduction techniques are developed in the neural recorder. The designed SoC was fabricated in a 0.18 μ m high-voltage Bipolar CMOS DMOS (BCD) process technology that was described in a previous publication and it has been recently tested in animal experiments that demonstrate the proposed SoC is capable of achieving reliable and simultaneous electrical stimulation and recording on the same nerve.

Frontiers in Human Neuroscience · Sep 2018

Spontaneous Neural Activity in the Superior Temporal Gyrus Recapitulates Tuning for Speech Features (opens in a new tab)

Jonathan D. Breshears, Liberty S. Hamilton, Edward F. Chang

Abstract

Background: Numerous studies have demonstrated that individuals exhibit structured neural activity in many brain regions during rest that is also observed during different tasks, however it is still not clear whether and how resting state activity patterns may relate to underlying tuning for specific stimuli. In the posterior superior temporal gyrus (STG), distinct neural activity patterns are observed during the perception of specific linguistic speech features. We hypothesized that spontaneous resting-state neural dynamics of the STG would be structured to reflect its role in speech perception, exhibiting an organization along speech features as seen during speech perception. Methods: Human cortical local field potentials were recorded from the superior temporal gyrus (STG) in 8 patients undergoing surgical treatment of epilepsy. Signals were recorded during speech perception and rest. Patterns of neural activity (high gamma power: 70-150 Hz) during rest, extracted with spatiotemporal principal component analysis, were compared to spatiotemporal neural responses to speech features during perception. Hierarchical clustering was applied to look for patterns in rest that corresponded to speech feature tuning. Results: Significant correlations were found between neural responses to speech features (sentence onsets, consonants, and vowels) and the spontaneous neural activity in the STG. Across subjects, these correlations clustered into five groups, demonstrating tuning for speech features-most robustly for acoustic onsets. These correlations were not seen in other brain areas, or during motor and spectrally-rotated speech control tasks. Conclusions: In this study, we present evidence that the RS structure of STG activity robustly recapitulates its stimulus-evoked response to acoustic onsets. Further, secondary patterns in RS activity appear to correlate with stimulus-evoked responses to speech features. The role of these spontaneous spatiotemporal activity patterns remains to be elucidated.

eneuro · Jul 2018

Parallel Arousal Pathways in the Lateral Hypothalamus (opens in a new tab)

Jaime E. Heiss, Akihiro Yamanaka, Thomas S. Kilduff

Abstract

Until recently, hypocretin (Hcrt) neurons were the only known wake-promoting neuronal population in the lateral hypothalamus (LH), but subpopulations of inhibitory neurons in this area and glutamatergic neurons in the nearby supramammillary nucleus (SuM) have recently been found that also promote wakefulness. We performed chemogenetic excitation of LH neurons in mice and observed increased wakefulness that lasted more than 4 h without unusual behavior or EEG anomalies. The increased wakefulness was similar in the presence or absence of the dual orexin receptor blocker almorexant (ALM). Analysis of hM3Dq transfection and c-FOS expression in LH inhibitory neurons and in the SuM failed to confirm that the increased wakefulness was due to these wake-promoting populations, although this possibility cannot be completely excluded. To evaluate the relationship to the Hcrt system, we repeated the study in Orexin-tTA mice in the presence or absence of dietary doxycycline (DOX), which enabled us to manipulate the percentage of Hcrt neurons that expressed hM3Dq. In DOX-fed mice, 18% of Hcrt neurons as well as many other LH neurons expressed hM3Dq; these mice showed a profound increase in wake after hM3Dq activation even in the presence of ALM. In mice switched to normal chow, 62% of Hcrt neurons expressed hM3Dq along with other LH cells; chemogenetic activation produced even more sustained arousal which could be reduced to previous levels by ALM treatment. Together, these results indicate an LH neuron population that promotes wakefulness through an Hcrt-independent pathway that can act synergistically with the Hcrt system to prolong arousal.

Frontiers in Cellular Neuroscience · May 2018

Histological Characterization of the Irritative Zones in Focal Cortical Dysplasia Using a Preclinical Rat Model (opens in a new tab)

Abhay Deshmukh, Jared Leichner, Jihye Bae, … Jorge J. Riera

Abstract

Current clinical practice in focal epilepsy involves brain source imaging (BSI) to localize brain areas where from interictal epileptiform discharges (IEDs) emerge. These areas, named irritative zones, have been useful to define candidate seizures-onset zones during pre-surgical workup. Since human histological data are mostly available from final resected zones, systematic studies characterizing pathophysiological mechanisms and abnormal molecular/cellular substrates in irritative zones-independent of them being epileptogenic-are challenging. Combining BSI and histological analysis from all types of irritative zones is only possible through the use of preclinical animal models. Here, we recorded 32-channel spontaneous electroencephalographic data from rats that have focal cortical dysplasia (FCD) and chronic seizures. BSI for different IED subtypes was performed using the methodology presented in Bae et al. (2015). Post-mortem brain sections containing irritative zones were stained to quantify anatomical, functional, and inflammatory biomarkers specific for epileptogenesis, and the results were compared with those obtained using the contralateral healthy brain tissue. We found abnormal anatomical structures in all irritative zones (i.e., larger neuronal processes, glioreactivity, and vascular cuffing) and larger expressions for neurotransmission (i.e., NR2B) and inflammation (i.e., ILβ1, TNFα and HMGB1). We conclude that irritative zones in this rat preclinical model of FCD comprise abnormal tissues disregarding whether they are actually involved in icto-genesis or not. We hypothesize that seizure perpetuation happens gradually; hence, our results could support the use of IED-based BSI for the early diagnosis and preventive treatment of potential epileptic foci. Further verifications in humans are yet needed.

Neurophotonics · Dec 2017

Alterations in neurovascular coupling following acute traumatic brain injury (opens in a new tab)

Hyounguk Jang, Stanley Huang, Daniel X. Hammer, … Jonathan A. N. Fisher

RZ5DPZ2ZIF-ClipEEG/ECoG/EMG
Abstract

Following acute traumatic brain injury (TBI), timely transport to a hospital can significantly improve the prognosis for recovery. There is, however, a dearth of quantitative biomarkers for brain injury that can be rapidly acquired and interpreted in active, field environments in which TBIs are frequently incurred. We explored potential functional indicators for TBI that can be noninvasively obtained through portable detection modalities, namely optical and electrophysiological approaches. By combining diffuse correlation spectroscopy with colocalized electrophysiological measurements in a mouse model of TBI, we observed concomitant alterations in sensory-evoked cerebral blood flow (CBF) and electrical potentials following controlled cortical impact. Injury acutely reduced the peak amplitude of both electrophysiological and CBF responses, which mostly recovered to baseline values within 30 min, and intertrial variability for these parameters was also acutely altered. Notably, the postinjury dynamics of the CBF overshoot and undershoot amplitudes differed significantly; whereas the amplitude of the initial peak of stimulus-evoked CBF recovered relatively rapidly, the ensuing undershoot did not appear to recover within 30 min of injury. Additionally, acute injury induced apparent low-frequency oscillatory behavior in CBF (<1 Hz). Histological assessment indicated that these physiological alterations were not associated with any major, persisting anatomical changes. Several time-domain features of the blood flow and electrophysiological responses showed strong correlations in recovery kinetics. Overall, our results reveal an array of stereotyped, injury-induced alterations in electrophysiological and hemodynamic responses that can be rapidly obtained using a combination of portable detection techniques.

Frontiers in Neuroscience · Apr 2017

A Rodent Model of Dynamic Facial Reanimation Using Functional Electrical Stimulation (opens in a new tab)

Mark A. Attiah, Julius de Vries, Andrew G. Richardson, Timothy H. Lucas

Abstract

Facial paralysis can be a devastating condition, causing disfiguring facial droop, slurred speech, eye dryness, scarring and blindness. This study investigated the utility of closed-loop functional electric stimulation (FES) for reanimating paralyzed facial muscles in a quantitative rodent model. The right buccal and marginal mandibular branches of the rat facial nerve were transected for selective, unilateral paralysis of whisker muscles. Microwire electrodes were implanted bilaterally into the facial musculature for FES and electromyographic (EMG) recording. With the rats awake and head-fixed, whisker trajectories were tracked bilaterally with optical micrometers. First, the relationship between EMG and volitional whisker movement was quantified on the intact side of the face. Second, the effect of FES on whisker trajectories was quantified on the paralyzed side. Third, closed-loop experiments were performed in which the EMG signal on the intact side triggered FES on the paralyzed side to restore symmetric whisking. The results demonstrate a novel in vivo platform for developing control strategies for neuromuscular facial prostheses.

Brain Connectivity · Apr 2017

Neural Correlates of Consciousness at Near-Electrocerebral Silence in an Asphyxial Cardiac Arrest Model (opens in a new tab)

Donald E. Lee, Lauren G. Lee, Danny Siu, … Yama Akbari

Abstract

Recent electrophysiological studies have suggested surges in electrical correlates of consciousness (i.e., elevated gamma power and connectivity) after cardiac arrest (CA). This study examines electrocorticogram (ECoG) activity and coherence of the dying brain during asphyxial CA. Male Wistar rats (n = 16) were induced with isoflurane anesthesia, which was washed out before asphyxial CA. Mean phase coherence and ECoG power were compared during different stages of the asphyxial period to assess potential neural correlates of consciousness. After asphyxia, the ECoG progressed through four distinct stages (asphyxial stages 1-4 [AS1-4]), including a transient period of near-electrocerebral silence lasting several seconds (AS3). Electrocerebral silence (AS4) occurred within 1 min of the start of asphyxia, and pulseless electrical activity followed the start of AS4 by 1-2 min. AS3 was linked to a significant increase in frontal coherence between the left and right motor cortices (p < 0.05), with no corresponding increase in ECoG power. AS3 was also associated with a significant posterior shift of ECoG power, favoring the visual cortices (p < 0.05). Although the ECoG during AS3 appears visually flat or silent when viewed with standard clinical settings, our study suggests that this period of transient near-electrocerebral silence contains distinctive neural activity. Specifically, the burst in frontal coherence and posterior shift of ECoG power that we find during this period immediately preceding CA may be a neural correlate of conscious processing.

Scientific Reports · Jan 2017

Highly Stable Glassy Carbon Interfaces for Long-Term Neural Stimulation and Low-Noise Recording of Brain Activity (opens in a new tab)

Maria Vomero, Elisa Castagnola, Francesca Ciarpella, … Davide Ricci

Abstract

We report on the superior electrochemical properties, in-vivo performance and long term stability under electrical stimulation of a new electrode material fabricated from lithographically patterned glassy carbon. For a direct comparison with conventional metal electrodes, similar ultra-flexible, micro-electrocorticography (μ-ECoG) arrays with platinum (Pt) or glassy carbon (GC) electrodes were manufactured. The GC microelectrodes have more than 70% wider electrochemical window and 70% higher CTC (charge transfer capacity) than Pt microelectrodes of similar geometry. Moreover, we demonstrate that the GC microelectrodes can withstand at least 5 million pulses at 0.45 mC/cm 2 charge density with less than 7.5% impedance change, while the Pt microelectrodes delaminated after 1 million pulses. Additionally, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) was selectively electrodeposited on both sets of devices to specifically reduce their impedances for smaller diameters (<60 μm). We observed that PEDOT-PSS adhered significantly better to GC than Pt, and allowed drastic reduction of electrode size while maintaining same amount of delivered current. The electrode arrays biocompatibility was demonstrated through in-vitro cell viability experiments, while acute in vivo characterization was performed in rats and showed that GC microelectrode arrays recorded somatosensory evoked potentials (SEP) with an almost twice SNR (signal-to-noise ratio) when compared to the Pt ones.

eLife · Mar 2016

The auditory representation of speech sounds in human motor cortex (opens in a new tab)

Connie Cheung, Liberty S Hamilton, Keith Johnson, Edward F Chang

Abstract

In humans, listening to speech evokes neural responses in the motor cortex. This has been controversially interpreted as evidence that speech sounds are processed as articulatory gestures. However, it is unclear what information is actually encoded by such neural activity. We used high-density direct human cortical recordings while participants spoke and listened to speech sounds. Motor cortex neural patterns during listening were substantially different than during articulation of the same sounds. During listening, we observed neural activity in the superior and inferior regions of ventral motor cortex. During speaking, responses were distributed throughout somatotopic representations of speech articulators in motor cortex. The structure of responses in motor cortex during listening was organized along acoustic features similar to auditory cortex, rather than along articulatory features as during speaking. Motor cortex does not contain articulatory representations of perceived actions in speech, but rather, represents auditory vocal information.

Neuroscience · 2016

Urodynamic function during sleep-like brain states in urethane anesthetized rats (opens in a new tab)

J. Crook, T. Lovick

Abstract

The aim was to investigate urodynamic parameters and functional excitability of the periaqueductal gray matter (PAG) during changes in sleep-like brain states in urethane anesthetized rats. Simultaneous recordings of detrusor pressure, external urethral sphincter (EUS) electromyogram (EMG), cortical electroencephalogram (EEG), and single-unit activity in the PAG were made during repeated voiding induced by continuous infusion of saline into the bladder. The EEG cycled between synchronized, high-amplitude slow wave activity (SWA) and desynchronized low-amplitude fast activity similar to slow wave and 'activated' sleep-like brain states. During (SWA, 0.5-1.5 Hz synchronized oscillation of the EEG waveform) voiding became more irregular than in the 'activated' brain state (2-5 Hz low-amplitude desynchronized EEG waveform) and detrusor void pressure threshold, void volume threshold and the duration of bursting activity in the external urethral sphincter EMG were raised. The spontaneous firing rate of 23/52 neurons recorded within the caudal PAG and adjacent tegmentum was linked to the EEG state, with the majority of responsive cells (92%) firing more slowly during SWA. Almost a quarter of the cells recorded (12/52) showed phasic changes in firing rate that were linked to the occurrence of voids. Inhibition (n=6), excitation (n=4) or excitation/inhibition (n=2) was seen. The spontaneous firing rate of 83% of the micturition-responsive cells was sensitive to changes in EEG state. In nine of the 12 responsive cells (75%) the responses were reduced during SWA. We propose that during different sleep-like brain states changes in urodynamic properties occur which may be linked to changing excitability of the micturition circuitry in the periaqueductal gray.

Nature Communications · Oct 2014

Graphene-based carbon-layered electrode array technology for neural imaging and optogenetic applications (opens in a new tab)

Dong-Wook Park, Amelia A. Schendel, Solomon Mikael, … Justin C. Williams

Abstract

Neural micro-electrode arrays that are transparent over a broad wavelength spectrum from ultraviolet to infrared could allow for simultaneous electrophysiology and optical imaging, as well as optogenetic modulation of the underlying brain tissue. The long-term biocompatibility and reliability of neural micro-electrodes also require their mechanical flexibility and compliance with soft tissues. Here we present a graphene-based, carbon-layered electrode array (CLEAR) device, which can be implanted on the brain surface in rodents for high-resolution neurophysiological recording. We characterize optical transparency of the device at >90% transmission over the ultraviolet to infrared spectrum and demonstrate its utility through optical interface experiments that use this broad spectrum transparency. These include optogenetic activation of focal cortical areas directly beneath electrodes, in vivo imaging of the cortical vasculature via fluorescence microscopy and 3D optical coherence tomography. This study demonstrates an array of interfacing abilities of the CLEAR device and its utility for neural applications.