Menu

Electrical Stimulation publications

Electrical stimulation delivered with TDT stimulators: microstimulation, deep brain and nerve stimulation.

Frontiers in Human Neuroscience · Oct 2021

Epidural Spinal Electrogram Provides Direct Spinal Recordings in Awake Human Participants (opens in a new tab)

John F. Burke, Nikhita Kunwar, Maria S. Yaroshinsky, … Doris D. Wang

Abstract

Little is known about the electrophysiological activity of the spinal cord during voluntary movement control in humans. We present a novel method for recording electrophysiological activity from the human spinal cord using implanted epidural electrodes during naturalistic movements including overground walking. Spinal electrograms (SEGs) were recorded from epidural electrodes implanted as part of a test trial for patients with chronic pain undergoing evaluation for spinal cord stimulation. Externalized ends of the epidural leads were connected to an external amplifier to capture SEGs. Electromyographic and accelerometry data from the upper and lower extremities were collected using wireless sensors and synchronized to the SEG data. Patients were instructed to perform various arm and leg movements while SEG and kinematic data were collected. This study proves the safety and feasibility of performing epidural spinal recordings from human subjects performing movement tasks.

Scientific Reports · Jul 2021

A wireless spinal stimulation system for ventral activation of the rat cervical spinal cord (opens in a new tab)

Matthew K. Hogan, Sean M. Barber, Zhoulyu Rao, … Philip J. Horner

Abstract

Electrical stimulation of the cervical spinal cord is gaining traction as a therapy following spinal cord injury; however, it is difficult to target the cervical motor region in a rodent using a non-penetrating stimulus compared with direct placement of intraspinal wire electrodes. Penetrating wire electrodes have been explored in rodent and pig models and, while they have proven beneficial in the injured spinal cord, the negative aspects of spinal parenchymal penetration (e.g., gliosis, neural tissue damage, and obdurate inflammation) are of concern when considering therapeutic potential. We therefore designed a novel approach for epidural stimulation of the rat spinal cord using a wireless stimulation system and ventral electrode array. Our approach allowed for preservation of mobility following surgery and was suitable for long term stimulation strategies in awake, freely functioning animals. Further, electrophysiology mapping of the ventral spinal cord revealed the ventral approach was suitable to target muscle groups of the rat forelimb and, at a single electrode lead position, different stimulation protocols could be applied to achieve unique activation patterns of the muscles of the forelimb.

Scientific Reports · May 2021

Both high fat and high carbohydrate diets impair vagus nerve signaling of satiety (opens in a new tab)

Hailley Loper, Monique Leinen, Logan Bassoff, … Matthew A. Schiefer

Abstract

Obesity remains prevalent in the US. One potential treatment is vagus nerve stimulation (VNS), which activates the sensory afferents innervating the stomach that convey stomach volume and establish satiety. However, current VNS approaches and stimulus optimization could benefit from additional understanding of the underlying neural response to stomach distension. In this study, obesity-prone Sprague Dawley rats consumed a standard, high-carbohydrate, or high-fat diet for several months, leading to diet-induced obesity in the latter two groups. Under anesthesia, the neural activity in the vagus nerve was recorded with a penetrating microelectrode array while the stomach was distended with an implanted balloon. Vagal tone during distension was compared to baseline tone prior to distension. Responses were strongly correlated with stomach distension, but the sensitivity to distension was significantly lower in animals that had been fed the nonstandard diets. The results indicate that both high fat and high carbohydrate diets impair vagus activity.

Scientific Reports · Apr 2021

High-fidelity transmission of high-frequency burst stimuli from peripheral nerve to thalamic nuclei in children with dystonia (opens in a new tab)

Estefanía Hernandez-Martin, Enrique Arguelles, Yifei Zheng, … Terence D. Sanger

Abstract

High-frequency peripheral nerve stimulation has emerged as a noninvasive alternative to thalamic deep brain stimulation for some patients with essential tremor. It is not known whether such techniques might be effective for movement disorders in children, nor is the mechanism and transmission of the peripheral stimuli to central brain structures understood. This study was designed to investigate the fidelity of transmission from peripheral nerves to thalamic nuclei in children with dystonia undergoing deep brain stimulation surgery. The ventralis intermediate (VIM) thalamus nuclei showed a robust evoked response to peripheral high-frequency burst stimulation, with a greatest response magnitude to intra-burst frequencies between 50 and 100 Hz, and reliable but smaller responses up to 170 Hz. The earliest response occurred at 12–15 ms following stimulation onset, suggesting rapid high-fidelity transmission between peripheral nerve and thalamic nuclei. A high-bandwidth, low-latency transmission path from peripheral nerve to VIM thalamus is consistent with the importance of rapid and accurate sensory information for the control of coordination and movement via the cerebello-thalamo-cortical pathway. Our results suggest the possibility of non-invasive modulation of thalamic activity in children with dystonia, and therefore the possibility that a subset of children could have beneficial clinical response without the need for invasive deep brain stimulation.

bioRxiv · Mar 2021

Enhancing neuronal plasticity through intracranial theta burst stimulation in the human sensorimotor cortex (opens in a new tab)

Jose L. Herrero, Alexander Smith, Akash Mishra, … Stephan Bickel

Abstract

The progress of therapeutic neuromodulation greatly depends on improving stimulation parameters to most efficiently induce neuroplasticity effects. Intermittent Theta Burst stimulation (iTBS), a form of electrical stimulation that mimics the natural brain activity patterns, has shown efficacy in inducing such effects in animal studies and rhythmic Transcranial Magnetic Stimulation (rTMS) studies in humans. However, little is known about the potential neuroplasticity effects of iTBS applied through intracranial electrodes in humans which could have implications for deep brain stimulation therapies. This study characterizes the physiological effects of cortical iTBS in the human cortex and compare them with single pulse alpha stimulation, another frequently used paradigm in rTMS research. We applied these stimulation paradigms to well-defined regions in the sensorimotor cortex which elicited contralateral hand or arm muscle contractions during electrical stimulation mapping in epilepsy patients implanted with intracranial electrodes. Treatment effects were evaluated using effective connectivity and beta oscillations coherence measures in areas connected to the treatment site as defined with cortico-cortical evoked potentials. Our results show that iTBS increases beta band synchronization within the sensorimotor network indicating a potential neuroplasticity effect. The effect is specific to the sensorimotor system, the beta frequency band and the stimulation pattern (no effect was found with single-pulse alpha stimulation). The effects outlasted the stimulation by three minutes. By characterizing the neurophysiological effects of iTBS within well-defined cortical networks, we hope to provide an electrophysiological framework that allows clinicians and researchers to optimize brain stimulation protocols which may have translational value.

bioRxiv · Mar 2021

A machine-learning algorithm correctly classifies cortical evoked potentials from both natural retinal stimulation and electrical stimulation of the optic nerve (opens in a new tab)

Vivien Gaillet, Elodie Geneviève Zollinger, Diego Ghezzi

Abstract

Objective Optic nerve’s intraneural stimulation is an emerging neuroprosthetic approach to provide artificial vision to totally blind patients. An open question is the possibility to evoke individual non-overlapping phosphenes via selective intraneural optic nerve stimulation. To begin answering this question, first, we aim at showing in preclinical experiments with animals that each intraneural electrode could evoke a distinguishable activity pattern in the primary visual cortex. Approach We performed both patterned visual stimulation and patterned electrical stimulation in healthy rabbits while recording evoked cortical activity with an electrocorticogram array in the primary visual cortex. Electrical stimulation was delivered to the optic nerve with the intraneural array OpticSELINE. We used a support vector machine algorithm paired to a linear regression model to classify cortical responses originating from visual stimuli located in different portions of the visual field and electrical stimuli from the different electrodes of the OpticSELINE. Main results Cortical activity induced by visual and electrical stimulation could be classified with nearly 100% accuracy relative to the specific location in the visual field or electrode in the array from which it originated. For visual stimulation, the accuracy increased with the separation of the stimuli and reached 100% for separation higher than 7 degrees. For electrical stimulation, at low current amplitudes, the accuracy increased with the distance between electrodes, while at higher current amplitudes, the accuracy was nearly 100% already for the shortest separation. Significance Optic nerve’s intraneural stimulation with the OpticSELINE induced discernible cortical activity patterns. These results represent a leap forward for intraneural optic nerve stimulation towards artificial vision.

Frontiers in Neuroscience · Mar 2021

Improving the Selectivity of an Osseointegrated Neural Interface: Proof of Concept For Housing Sieve Electrode Arrays in the Medullary Canal of Long Bones (opens in a new tab)

Augusto X. T. Millevolte, Aaron M. Dingle, Jared P. Ness, … Samuel O. Poore

Abstract

Sieve electrodes stand poised to deliver the selectivity required for driving advanced prosthetics but are considered inherently invasive and lack the stability required for a chronic solution. This proof of concept experiment investigates the potential for the housing and engagement of a sieve electrode within the medullary canal as part of an osseointegrated neural interface (ONI) for greater selectivity toward improving prosthetic control. The working hypotheses are that (A) the addition of a sieve interface to a cuff electrode housed within the medullary canal of the femur as part of an ONI would be capable of measuring efferent and afferent compound nerve action potentials (CNAPs) through a greater number of channels; (B) that signaling improves over time; and (C) that stimulation at this interface generates measurable cortical somatosensory evoked potentials through a greater number of channels. The modified ONI was tested in a rabbit ( n = 1) amputation model over 12 weeks, comparing the sieve component to the cuff, and subsequently compared to historical data. Efferent CNAPs were successfully recorded from the sieve demonstrating physiological improvements in CNAPs between weeks 3 and 5, and somatosensory cortical responses recorded at 12 weeks postoperatively. This demonstrates that sieve electrodes can be housed and function within the medullary canal, demonstrated by improved nerve engagement and distinct cortical sensory feedback. This data presents the conceptual framework for housing more sophisticated sieve electrodes in bone as part of an ONI for improving selectivity with percutaneous connectivity toward improved prosthetic control.

bioRxiv · Feb 2021

Interaural Time Difference Tuning in the Rat Inferior Colliculus is Predictive of Behavioral Sensitivity (opens in a new tab)

Kongyan Li, Vani G. Rajendran, Ambika Prasad Mishra, … Jan W. H. Schnupp

Abstract

Recent studies have shown that rats are a useful model for binaural cochlear implant (CI) research, with behavioral sensitivity to interaural time differences (ITDs) of CI stimuli which are better than those of human patients. Here, we characterize ITD tuning in the rat inferior colliculus (IC) and explore whether quality of tuning can predict behavioral performance. We recorded IC responses to stimuli of varying pulse rates and envelope types and quantified both mutual information (MI) and neural d ′ as measures of ITD sensitivity. Neural d ′ values paralleled behavioral ones, declining with increasing click rates or when envelopes changed from rectangular to Hanning windows. While MI values increased with experience, neural d ′ did not. However, neural d ′ values correlated much better with behavioral performance than MI. Thus, neural d ′ appears to be a particularly well suited to predicting how stimulus parameters will impact behavioral performance.

Aug 2020

Vagus Nerve Stimulation Evoked Electroneurography and Electromyography Recordings in Swine v1 (opens in a new tab)

Evan N Nicolai, Kip Ludwig

Abstract

This protocol was used to collect data now published in the Journal of Neural Engineering, Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs, see Metadata for citation. Additionally, the dataset is publicly available on Pennsieve 10.26275/qcuk-a8ty.

Frontiers in Neuroscience · Jul 2020

Optimal Multichannel Artifact Prediction and Removal for Neural Stimulation and Brain Machine Interfaces (opens in a new tab)

Mina Sadeghi Najafabadi, Longtu Chen, Kelsey Dutta, … Monty A. Escabí

Abstract

Neural implants that deliver multi-site electrical stimulation to the nervous systems are no longer the last resort but routine treatment options for various neurological disorders. Multi-site electrical stimulation is also widely used to study nervous system function and neural circuit transformations. These technologies increasingly demand dynamic electrical stimulation and closed-loop feedback control for real-time assessment of neural function, which is technically challenging since stimulus-evoked artifacts overwhelm the small neural signals of interest. We report a novel and versatile artifact removal method that can be applied in a variety of settings, from single- to multi-site stimulation and recording and for current waveforms of arbitrary shape and size. The method capitalizes on linear electrical coupling between stimulating currents and recording artifacts, which allows us to estimate a multi-channel linear Wiener filter to predict and subsequently remove artifacts via subtraction. We confirm and verify the linearity assumption and demonstrate feasibility in a variety of recording modalities, including in vitro sciatic nerve stimulation, bilateral cochlear implant stimulation, and multi-channel stimulation and recording between the auditory midbrain and cortex. We demonstrate a vast enhancement in the recording quality with a typical artifact reduction of 25-40 dB. The method is efficient and can be scaled to arbitrary number of stimulus and recording sites, making it ideal for applications in large-scale arrays, closed-loop implants, and high-resolution multi-channel brain-machine interfaces.

Journal of Neural Engineering · Apr 2020

Signal recovery from stimulation artifacts in intracranial recordings with dictionary learning (opens in a new tab)

D J Caldwell, J A Cronin, R P N Rao, … B W Brunton

Abstract

Objective: Electrical stimulation of the human brain is commonly used for eliciting and inhibiting neural activity for clinical diagnostics, modifying abnormal neural circuit function for therapeutics, and interrogating cortical connectivity. However, recording electrical signals with concurrent stimulation results in dominant electrical artifacts that mask the neural signals of interest. Here we develop a method to reproducibly and robustly recover neural activity during concurrent stimulation. We concentrate on signal recovery across an array of electrodes without channel-wise fine-tuning of the algorithm. Our goal includes signal recovery with trains of stimulation pulses, since repeated, high-frequency pulses are often required to induce desired effects in both therapeutic and research domains. We have made all of our code and data publicly available. Approach: We developed an algorithm that automatically detects templates of artifacts across many channels of recording, creating a dictionary of learned templates using unsupervised clustering. The artifact template that best matches each individual artifact pulse is subtracted to recover the underlying activity. To assess the success of our method, we focus on whether it extracts physiologically interpretable signals from real recordings. Main results: We demonstrate our signal recovery approach on invasive electrophysiologic recordings from human subjects during stimulation. We show the recovery of meaningful neural signatures in both electrocorticographic (ECoG) arrays and deep brain stimulation (DBS) recordings. In addition, we compared cortical responses induced by the stimulation of primary somatosensory (S1) by natural peripheral touch, as well as motor cortex activity with and without concurrent S1 stimulation. Significance: Our work will enable future advances in neural engineering with simultaneous stimulation and recording.

Scientific Reports · Feb 2020

Ramped pulse shapes are more efficient for cochlear implant stimulation in an animal model (opens in a new tab)

Charlotte Amalie Navntoft, Jeremy Marozeau, Tania Rinaldi Barkat

Abstract

In all commercial cochlear implant (CI) devices, the electric stimulation is performed with a rectangular pulse that generally has two phases of opposite polarity. To date, developing new stimulation strategies has relied on the efficacy of this shape. Here, we investigate the potential of a novel stimulation paradigm that uses biophysically-inspired electrical ramped pulses. Using electrically-evoked auditory brainstem response (eABR) recordings in mice, we found that less charge, but higher current level amplitude, is needed to evoke responses with ramped shapes that are similar in amplitude to responses obtained with rectangular shapes. The most charge-efficient pulse shape had a rising ramp over both phases, supporting findings from previous in vitro studies. This was also true for longer phase durations. Our study presents the first physiological data on CI-stimulation with ramped pulse shapes. By reducing charge consumption ramped pulses have the potential to produce more battery-efficient CIs and may open new perspectives for designing other efficient neural implants in the future.

Scientific Reports · Aug 2018

A Proof-of-Concept Study of Transcutaneous Magnetic Spinal Cord Stimulation for Neurogenic Bladder (opens in a new tab)

Tianyi Niu, Carol J. Bennett, Tina L. Keller, … Daniel C. Lu

Abstract

Patients with chronic spinal cord injury (SCI) cannot urinate at will and must empty the bladder by self-catheterization. We tested the hypothesis that non-invasive, transcutaneous magnetic spinal cord stimulation (TMSCS) would improve bladder function in individuals with SCI. Five individuals with American Spinal Injury Association Impairment Scale A/B, chronic SCI and detrusor sphincter dyssynergia enrolled in this prospective, interventional study. After a two-week assessment to determine effective stimulation characteristics, each patient received sixteen weekly TMSCS treatments and then received “sham” weekly stimulation for six weeks while bladder function was monitored. Bladder function improved in all five subjects, but only during and after repeated weekly sessions of 1 Hz TMSCS. All subjects achieved volitional urination. The volume of urine produced voluntarily increased from 0 cc/day to 1120 cc/day (p = 0.03); self-catheterization frequency decreased from 6.6/day to 2.4/day (p = 0.04); the capacity of the bladder increased from 244 ml to 404 ml (p = 0.02); and the average quality of life ranking increased significantly (p = 0.007). Volitional bladder function was re-enabled in five individuals with SCI following intermittent, non-invasive TMSCS. We conclude that neuromodulation of spinal micturition circuitry by TMSCS may be used to ameliorate bladder function.

Brain Sciences · Jul 2018

Pediatric Deep Brain Stimulation Using Awake Recording and Stimulation for Target Selection in an Inpatient Neuromodulation Monitoring Unit (opens in a new tab)

Terence D. Sanger, Mark Liker, Enrique Arguelles, … Aaron Robison

Abstract

Deep brain stimulation (DBS) for secondary (acquired, combined) dystonia does not reach the high degree of efficacy achieved in primary (genetic, isolated) dystonia. We hypothesize that this may be due to variability in the underlying injury, so that different children may require placement of electrodes in different regions of basal ganglia and thalamus. We describe a new targeting procedure in which temporary depth electrodes are placed at multiple possible targets in basal ganglia and thalamus, and probing for efficacy is performed using test stimulation and recording while children remain for one week in an inpatient Neuromodulation Monitoring Unit (NMU). Nine Children with severe secondary dystonia underwent the NMU targeting procedure. In all cases, 4 electrodes were implanted. We compared the results to 6 children who had previously had 4 electrodes implanted using standard intraoperative microelectrode targeting techniques. Results showed a significant benefit, with 80% of children with NMU targeting achieving greater than 5-point improvement on the Burke–Fahn–Marsden Dystonia Rating Scale (BFMDRS), compared with 50% of children using intraoperative targeting. NMU targeting improved BFMDRS by an average of 17.1 whereas intraoperative targeting improved by an average of 10.3. These preliminary results support the use of test stimulation and recording in a Neuromodulation Monitoring Unit (NMU) as a new technique with the potential to improve outcomes following DBS in children with secondary (acquired) dystonia. A larger sample size will be needed to confirm these results.

bioRxiv · May 2018

Optic nerve intraneural stimulation allows selective visual cortex activation (opens in a new tab)

Vivien Gaillet, Annarita Cutrone, Paola Vagni, … Diego Ghezzi

Abstract

Retinal prostheses have been developed to restore a functional form of vision in patients affected by outer retinal layer dystrophies. Other approaches, namely optic nerve, thalamic, and cortical prostheses are under investigation to expand this toolbox both as clinical devices and as tools for fundamental research. Optic nerve stimulation is attractive since it bypasses the entire retinal network and directly activates nerve fibers. At the same time, it still takes advantage of the high-level information processing occurring downstream in the visual cortex. Here we show that a new intraneural electrode array (OpticSELINE) is effective in inducing the activation of the visual cortex upon electrical stimulation of the optic nerve. We also demonstrate that intraneural optic nerve stimulation induces selective cortical activation patterns depending on the stimulating electrode, thus suggesting that the OpticSELINE possesses spatial selectivity in fiber stimulation. In conclusion, the OpticSELINE can be used both as visual prosthesis for blind patients and as tool to further investigate the effect of the electrical stimulation in the visual system.

2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Jul 2017

Retinal electrostimulation in rats: Activation thresholds from superior colliculus and visual cortex recordings (opens in a new tab)

Alejandro Barriga-Rivera, Tianruo Guo, John W. Morley, … Gregg J. Suaning

Abstract

Retinal neuromodulation is an emerging therapeutic approach to restore functional vision to those suffering retinal photoreceptor degeneration. The retina encodes visual information and transmits it to the brain. Replicating this retinal code through electrical stimulation is essential to improving the performance of visual prostheses. In doing so, the first step relies on precise neural recordings from visual centers that allow studying the response of these neurons to electrical stimulation of the retina. This paper demonstrates the feasibility of a rat model to conduct highly reliable electrophysiological studies in the field of retinal neuromodulation. A disc electrode, implanted in the retrobulbar space was used to stimulate the retina of Long-Evans rats. Buzsaki multi-electro arrays were inserted in the superior colliculus (SC) to record electrical activity propagated from the retinal ganglion cells (RGCs). Activation thresholds calculated from local field potentials (visual cortex) and from neural spikes (SC) were contrasted. Both values were comparable to those in humans and in other animal models, and were slightly higher when estimated from SC recordings. However, differences were not statistically significant.