TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Psychoacoustics publications

Listening experiments in people and animals, with sounds generated and timed by TDT systems.

1,902 papers

The Journal of the Acoustical Society of America · 1996

Observer weighting of concurrent binaural information (opens in a new tab)

Stellmack MA, Lutfi RA

Abstract

Two experiments examined how listeners weight binaural information of individual components in a multicomponent complex when they are instructed to use this information in various ways. On each experimental trial of the first experiment, a two-component complex consisting of a 553- and 753-Hz pure tone was presented to listeners over headphones. Each component had an interaural difference of time (IDT) that was randomly chosen from a single distribution. Listeners were to indicate the apparent position of the intracranial image relative to the midline on the basis of either the IDT of the 753-Hz component, the sum of the IDTs of the two components, or the difference between the two IDTs. Observer weights for the component IDTs were derived by computing the point-biserial correlations between the IDTs of the components and the listeners' left-right judgments. Three of the four listeners were found to adjust their weighting of the binaural information appropriately for each listening task, while the fourth listener consistently gave almost no weight to the 553-Hz component regardless of the listening condition. In a second experiment, listeners were instructed to attend to the randomly selected IDT of one of three components (553, 753, or 953 Hz) and to indicate whether the intracranial image produced by that component was to the left or right of midline. Only one of six listeners gave greatest weight to the target component regardless of its frequency. The other five listeners gave significant weight to all three components in all listening conditions. In all cases, individual differences in percent correct performance could be attributed largely to individual differences in weights with little variation in internal noise.

The Journal of the Acoustical Society of America · Dec 1995

Lateralization of comodulated complex waveforms (opens in a new tab)

Saberi K

Abstract

This study examines the ability to lateralize a complex signal characterized by correlated temporal activity across widely separated frequency regions. The high-frequency complex consisted of two narrow-band stimuli. The two stimuli had common interaural delays but different carriers centered on nonoverlapping critical bands. Two basic conditions were examined: The narrow-band stimuli had temporal envelopes which were (1) identical or (2) different. In the first experiment, narrow bands of noise were used which either had identical temporal envelopes (comodulated) or statistically independent envelopes (CFs = 2550 and 3350 Hz). In the second experiment, two sinusoidally amplitude-modulated (SAM) tones were used whose modulators either had the same starting phase or a different starting phase (CFs = 2550 and 4000 Hz). Results of the first experiment showed that for bandwidths narrower than 300 Hz, comodulated bands produced significantly lower interaural-delay thresholds compared to independent bands. Results of the second experiment showed that when the two SAM tones (100-Hz modulation rate) had the same modulator starting phase, interaural-delay thresholds were lowest.

The Journal of the Acoustical Society of America · Dec 1995

Age effects on duration discrimination with simple and complex stimuli (opens in a new tab)

Fitzgibbons PJ, Gordon-Salant S

Abstract

This study examined age-related changes in temporal processing by measuring DLs for signal duration using simple and complex stimuli. Previous research has shown that elderly listeners exhibit difficulty discriminating duration changes in simple sounds, suggesting the possibility of age-related changes in central timing mechanisms. The present experiments examined the interactive effects of aging, hearing loss, and stimulus complexity on duration discrimination. Four groups participated: young and elderly listeners with normal hearing, and young and elderly listeners with hearing loss. Duration DLs were measured for 250-ms tone bursts and for silent gaps between tone bursts that were presented either in isolation or embedded as target stimuli within tonal sequences. The tone sequences were composed of five sequential 250-ms components. Stimulus complexity was varied by changing the sequential order of tone frequencies and the location of an embedded target component across listening conditions. Analyses of results revealed the following: Elderly listeners performed more poorly than younger listeners in nearly all stimulus conditions, the effects of stimulus complexity on discrimination were greatest among elderly listeners, and hearing loss had no systematic effect on discrimination performance.

Journal of Vestibular Research · Nov 1995

The accuracy of absolute localization judgments for speech stimuli (opens in a new tab)

Gilkey RH, Anderson TR

Abstract

Communication signals are likely to be one of the primary forms of acoustic stimulation within three-dimensional auditory displays, yet the ability to localize these signals has received relatively little study. We investigated the ability to localize single-word speech targets, spoken by one male and one female talker, as compared to the ability to localize click targets. On each trial, the targets could arise from any one of 239 speaker locations that surrounded the subject in azimuth and ranged from -45 degrees to +90 degrees in elevation. The results showed that localization accuracy relative to the median plane (the Left/Right dimension) was good for both the speech and nonspeech targets. However, with speech targets, there were more front/back reversals (inaccurate judgments relative to the frontal plane, the Front/Back dimension) and typically less accurate elevation judgments (inaccurate judgments relative to the horizontal plane, the Up/Down dimension) than were found with click targets. These results have important implications for applications of spatial hearing technology and suggest that need for caution when designing three-dimensional auditory displays in order to assure that spatial information is conveyed appropriately.

Journal of Speech and Hearing Research · Oct 1995

Reliability and sensitivity of paired comparisons and category rating in children (opens in a new tab)

Eisenberg LS, Dirks DD

Abstract

Children's subjective judgments of speech clarity using the methods of paired comparisons and category rating were evaluated in this investigation. Eighty children with normal hearing between the ages of 4 and 8 years judged the clarity of sentences that were systematically bandpass-filtered using conditions that increased intelligibility as estimated by the Articulation Index. Subjects were classified into four age groups (4-, 5-, 6-, and 7-8-year age groups) with 20 subjects per group. With use of materials and training methods suitable for children, judgments were obtained via the two psychophysical procedures (10 subjects per age group for each procedure). Results indicated that children 5 years of age and older were able to make reliable clarity judgments using either procedure; however, the method of paired comparisons was more sensitive than category rating in detecting differences between the bandpass-filtered conditions.

The Journal of the Acoustical Society of America · Sep 1995

The effects of sinusoidal amplitude modulation on gap detection in noise (opens in a new tab)

Snell KB

Abstract

The purpose of this study was to investigate the effects of envelope fluctuation on temporal gap detection. Temporal gap detection thresholds were measured in wideband noisebursts that had been amplitude modulated by a very low-frequency sinusoid. Detection was studied at six modulation depths and in four phase conditions which placed the onset of the silent gap at different amplitudes on the temporal envelope of the waveform. Gap thresholds were obtained in a 3IFC paradigm in four young, normal-hearing subjects. The smallest mean gap threshold, 3.5 ms, was obtained for unmodulated noisebursts. The largest mean gap threshold, 25.7 ms, was obtained at a modulation depth of 100%. Phase did not significantly affect gap detection until modulation depth was increased to 40%. At deeper depths of modulation, gap thresholds were smallest, but also most variable, when the gap onset was placed at a peak in the waveform envelope and largest when the gaps were centered on an envelope minimum or randomly placed. Results of this study are consistent with previous findings and the hypothesis that gap detection is dependent on the similarity of the gap itself to inherent fluctuations in the stimulus envelope, reflecting coherence in terms of phase and depth of envelope fluctuation.

The Journal of the Acoustical Society of America · Jul 1995

Behavioral auditory thresholds for sinusoidal electrical stimuli in the cat (opens in a new tab)

Smith DW, Watt S, Konrad KE, Olszyk VB

Abstract

Behavioral thresholds were measured in four cats by training them to respond behaviorally to acoustic auditory stimuli using food as a reward in an operant reinforcement paradigm. Following training, the subjects were implanted unilaterally with either a scaled-UCSF electrode containing four contacts or an electrode array containing eight intracochlear contacts and one extracochlear contact under temporalis muscle. Behavioral thresholds for electrical stimuli were obtained as a function of sinusoidal frequency, duration, and electrode configuration. Threshold functions for both electrode types and all animals had minima between 48 and 125 Hz and, in general, were relatively flat below this minima; functions increased at 3-6 dB/octave from 96 Hz to 1 kHz. Threshold varied predictably as a function of electrode configuration, with thresholds decreasing as much as 20 dB as electrode spacing was widened from a radial bipolar (200-microns separation) to a monopolar configuration (apical stimulating and temporalis return). With long-duration stimuli, increasing the electrode separation systematically increased the slope of the threshold-versus-frequency contours in all animals. Irrespective of electrode type or configuration, charge/phase thresholds for single-cycle sinusoids were relatively flat for stimulus periods up to 1-5 ms, approximating a constant charge/phase determination of threshold. At phase durations greater than 5 ms, charge thresholds increased at a rate slightly above 6 dB/octave (constant peak current), which was suggestive of neural accommodation. Thresholds for the cat share many features with those reported for implanted humans and monkeys.

The Journal of the Acoustical Society of America · May 1995

Within‐and across‐channel processes in modulation detection interference (opens in a new tab)

Mendoza L, Hall JW 3rd, Grose JH

Abstract

Modulation detection interference (MDI) describes the effect of an amplitude-modulated sound on detection of amplitude modulation (AM) on a spectrally distant target sound. In MDI, AM detection is worsened by an AM interfering sound. Previous research has implicated both within-channel and across-channel processes as the basis for MDI. This study examined the detection of 10-Hz sinusoidal AM as a function of the spectral relationship, gating synchrony, and ear of presentation of the target and interfering sounds. Using a 993-Hz target sound, AM detection improved as the frequency of the interferer increased from 1250 to 2188 Hz, and as it decreased from 788 to 450 Hz. MDI was less for continuous interferers than for interferers gated synchronously with the target. In the continuous interferer conditions, however, MDI was still greatest for interferers most proximal to the target. The effects of frequency proximity and gating asynchrony were also evident using interferers presented to the ear contralateral to the target ear. While a 1250-Hz interferer led to more MDI than a 788-Hz interferer when the interferers were presented to the same ear as a 993-Hz target, no significant asymmetry was noted with dichotic stimulation. Taken together, the results of these experiments indicated that MDI is the result of across-channel, and to a limited extent, within-channel processes.

The Journal of the Acoustical Society of America · Apr 1995

Masked thresholds and consonant recognition in low‐pass maskers for hearing‐impaired and normal‐hearing listeners (opens in a new tab)

Dubno JR, Ahlstrom JB

Abstract

Thresholds and consonant recognition were measured in six low-pass maskers as a function of masker bandwidth for hearing-impaired subjects and for normal-hearing subjects listening in spectrally shaped broadband noise (SSBB). SSBB was adjusted such that thresholds in that masker for a normal-hearing listener were equal to a hearing-impaired listener's absolute thresholds. Thresholds measured in low-pass maskers were higher for hearing-impaired than for normal-hearing subjects for signal frequencies both within and outside masker passbands, although threshold differences were larger for signal frequencies outside masker passbands. Slopes of functions relating consonant recognition to speech level were not significantly different between groups, due to the presence of SSBB for the normal-hearing listeners. However, 25% of observed scores for hearing-impaired listeners, compared to only 5% of observed scores for normal-hearing listeners, were significantly poorer than predicted by the articulation index (AI), when AIs were computed using subjects' absolute thresholds. Better correspondence between observed and predicted scores in low-pass maskers was achieved when AIs were derived empirically from thresholds measured in each low-pass masker. Hence poorer-than-predicted consonant recognition scores in low-pass maskers were accounted for by higher-than-normal thresholds in those maskers.

Acta Oto-Laryngologica · Mar 1995

Contralateral suppression of evoked otoacoustic emissions and detection of a multi-tone complex in noise (opens in a new tab)

Micheyl C, Morlet T, Giraud AL, … Morgon A

Abstract

Although some findings suggest that auditory efferent fibers are involved in perception in noise, their function remains controversial. The contralateral suppression of evoked otoacoustic emissions (EOAEs) has recently provided a means of exploring the medial olivocochlear system (MOCS) in humans. In an experiment based on this paradigm, the present study examined the relationships between variations of both EOAEs and detection-in-noise thresholds, induced in the same subjects by a contralateral 50-dB-SPL broad-band noise masker. EOAEs were recorded in response to a burst of a multitone complex composed of 1, 1.5 and 2-kHz components. The detection thresholds of this 3-component complex were measured at 2 ipsilateral noise levels: 50 and 70 dB SPL. The main finding was a significant correlation between EOAE suppression and threshold variations under contralateral masking. A relationship was also found between the contralateral suppression of EOAEs and threshold variation induced by the increase in ipsilateral noise level. These findings support the notion that the MOCS is involved in the detection of multicomponent stimuli in noise.

Proceedings of the Human Factors and Ergonomics Society Annual Meeting · 1995

Auditory icons as warning and advisory signals in the US Army Battlefield Combat Identification System (BCIS) (opens in a new tab)

Ellen Haas, Jeffrey Schmidt

Abstract

The U.S. Army proposed the Battlefield Combat Identification System (BCIS) to diminish fratricide by providing five critical auditory and visual warning signals. The purpose of this experiment was to determine whether the auditory warning signals designed by the U.S. Army Human Research and Engineering Directorate (HRED) provided greater user association with the BCIS signal functions than did signals designed by a contractor. The contractor signals consisted of pure tones, while the HRED signals were auditory icons designed with intent to provide a high level of user association. The dependent variable was the subject's free-modulus magnitude estimation rating of the degree of association of the signal with the signal function. Subjects were 20 male U.S. Army Infantrymen. Data were analyzed using t-tests for paired samples. Results indicated that the mean perceived association was significantly greater for the HRED auditory icons in one of five cases, and greater (but not significantly so) in two additional cases. There were no other significant differences. Implications for auditory display design are discussed.

Ear & Hearing · Dec 1994

Simultaneous measurement of tinnitus pitch and loudness (opens in a new tab)

Penner MJ, Saran A

Abstract

Objective Simultaneous measures of the frequency and level of a pure tone matching the predominant pitch and loudness of tinnitus were obtained using four interleaved staircases. Design Two staircases in a forced-choice procedure tracked two frequencies, one higher and one lower than the predominant pitch of the tinnitus, while two staircases tracked two levels, one louder and one softer than the tinnitus. Results The standard deviation of the pitch matches to tinnitus using the forced-choice procedure with four staircases (4SFC) exceeded that from a double staircase (2SFC) task in which the level of the matching tone was fixed, whereas the 2SFC and 4SFC tasks had similar SDs for loudness matches to tinnitus when the frequency of the matching tone was fixed and for matches to the pitch or loudness of external tones. As the level of the tone matching the tinnitus pitch in the 4SFC task increased relative to that of the 2SFC task, so did its frequency. Conclusion These data may be interpreted as indicating that tinnitus is a fluctuant signal, and that matches of pure tones to tinnitus are not single-valued.

The Journal of the Acoustical Society of America · Oct 1994

Amplitude modulation rate discrimination with sinusoidal carriers (opens in a new tab)

Lee J

Abstract

Discrimination of the change in rate of sinusoidal amplitude modulation was investigated for sinusoidal carriers. The just-noticeable change in the modulation rate was measured as a function of (1) carrier frequency (fc = 500, 1000, 2000, or 4000 Hz), (2) initial modulation rate (fm = 10, 20, 40, 80, 160, or 320 Hz), and (3) stimulus duration (T = 62, 125, 250, 500, 1000, or 2000 ms). For modulation rates less than 320 Hz, the thresholds for a change in modulation rate were not affected by changing the carrier frequency. When fm = 320 Hz, the threshold for changes in the modulation rate ordered in the same way as the threshold for changes in the frequency of a pure tone, suggesting that the primary cue for discriminating a change in modulation rate was the frequency of either sideband. As stimulus duration increased to a certain T (critical duration), the thresholds decreased by more than a factor of 2. Above that duration, the thresholds for changes in modulation rate decreased only slightly or remained constant. The critical duration corresponded to about five cycles of modulation, at least for the slower modulation rates.

The Journal of the Acoustical Society of America · Oct 1994

Loudness growth in forward masking: Relation to intensity discrimination (opens in a new tab)

Zeng FG

Abstract

The growth of loudness of a tone burst following an intense forward masker was measured as a function of the tone level. The level of the forward-masked tone was adjusted to balance the loudness of a standard tone presented without a forward masker, using a 2AFC, double-staircase, tracking procedure. The forward masker was a 90-dB SPL, 100-ms, 1000-Hz pure tone. The standard tone and the masked tone were both 25-ms, 1000-Hz pure tones. The forward masker and the masked tone were always presented in the first interval. With a 100-ms delay between them, there was little or no threshold elevation for the masked tone. However, the masker caused the masked tone to sound louder than it would if it had not been masked, a phenomenon termed "loudness enhancement" [Irwin and Zwislocki, Percept. Psychophys. 10, 189-192 (1971); Galambos et al., J. Acoust. Soc. Am. 52, 1127-1130 (1972)]. In addition, the present results show a nonmonotonic enhancement function that the forward masker introduced a 10-16-dB enhancement effect for tones of 40-65 dB SPL and no significant effect for the 30 and 90 dB SPL tones. The loudness variability in forward masking was estimated from the upper and lower sequences tracking the 21% and the 79% louder response levels on the psychometric function, respectively. The variability demonstrated a similar nonmonotonic function. In forward masking loudness grows more steeply at low-medium sensation levels, and merges with normal growth at high levels.(ABSTRACT TRUNCATED AT 250 WORDS)

The Journal of the Acoustical Society of America · Sep 1994

The effects of signal frequency and absolute bandwidth on gap detection in noise (opens in a new tab)

Snell KB, Ison JR, Frisina DR

Abstract

Whether temporal resolution in noisebursts is primarily determined by the highest frequency component in the signal or its absolute bandwidth remains unclear. In this study, the absolute bandwidths and upper cutoff frequencies of signal noisebursts were varied across broad frequency ranges, several times greater than previously jointly studied. The purpose was to determine how each independently affects detection, taking into consideration that bandwidth effects at one signal frequency might be very different from bandwidth effects at another. Gap detection thresholds were obtained for five subjects with normal hearing in a 2 IFC paradigm. Signals were noisebursts whose bandwidths and upper cutoff frequencies varied among 1, 2, 4, 8, and 12 kHz. Their duration was 150 ms and they were presented at an overall level of 75 dB SPL above a 45 dB SPL white noise floor. The largest mean gap detection threshold, 6.98 ms, was obtained for a noiseburst with a bandwidth of 1 kHz and upper cutoff frequency of 12 kHz. The smallest mean gap detection threshold, 2.22 ms, was found with a bandwidth and upper cutoff frequency of 12 kHz. Significant interactions were found to exist between absolute bandwidth and upper cutoff frequency. Although gap detection thresholds generally decreased with increasing signal frequency and bandwidth, the pattern was complex. When the absolute bandwidth was at least one-half the upper cutoff frequency then upper cutoff frequency and not bandwidth determined gap sensitivity; but when the absolute bandwidth was less than one-half of the upper frequency, then both determined gap thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Hearing Research · Jun 1994

Perception of temporal acoustic patterns by the goldfish (Carassius auratus) (opens in a new tab)

Fay RR

Abstract

The perception of temporal acoustic patterns was studied in the goldfish using classical respiratory conditioning in combination with a stimulus generalization paradigm. Stimuli consisted of a bandpass filtered pulse repeated in various periodic and aperiodic temporal patterns. In each of 14 experiments, animals received 40 conditioning trials to a given stimulus pattern and were then tested for generalization to eight novel stimuli differing only in temporal pattern. In experiments 1-5, animals were conditioned to a periodic pulse train with a particular interpulse interval (IPI) and then tested to novel periodic pulse trains with various IPIs. Generalization gradients were substantially symmetric and monotonic with repetition rate, suggesting a perceptual continuum in goldfish that is similar to periodicity pitch or roughness in human listeners. Several additional experiments indicated that the perceptual qualities of simple and complex temporal patterns are not primarily determined by spectral structure or pulse rate, but rather are determined by the distribution of IPIs. A model for the central analysis of IPIs was successful in accounting for the results of experiments in which animals were conditioned to simple, periodic stimuli. However, the model failed when animals were conditioned to more complex stimuli having aperiodic temporal patterns. These experiments demonstrate the potential usefulness of the stimulus generalization paradigm for investigating aspects of complex sound source perception in non-human animals.

Hearing Research · May 1994

Monaural sound localization: acute versus chronic unilateral impairment (opens in a new tab)

Slattery WH 3rd, Middlebrooks JC

Abstract

We tested the ability of human listeners to localize broadband noise bursts in the absence of binaural localization cues. The subject population consisted of five patients, who had normal hearing in one ear and congenital deafness in the other, and seven normal controls, who were tested with both ears open and with one ear plugged. Consistent with previous reports, the introduction of an ear plug unilaterally into control subjects resulted in a prominent lateral displacement in their localization judgements by an average of 30.9 degrees toward the side of the open ear. Vertical localization was less strongly impaired. The five monaural patients showed a considerable range of ability to localize sounds. Two of the patients were essentially indistinguishable from the plugged control subjects in that they showed a prominent displacement of responses toward the side of the hearing ear. The other three subjects localized significantly better than the plugged controls, in that they demonstrated little or no lateral displacement toward the hearing side and that they localized targets on the hearing and on the impaired sides about equally well. The performance of these latter patients demonstrates that monaural cues can provide useful localization information in the horizontal as well as in the vertical dimension.

Otolaryngology · 1994

Covariation of tinnitus pitch and the associated emission: A case study (opens in a new tab)

Penner MJ, Glotzbach L

Abstract

Tinnitus in one female subject was found to be related to numerous (as many as 21) bilateral spontaneous otoacoustic emissions. The association of tinnitus and spontaneous otoacoustic emissions was empirically supported by the masking/suppression demonstration. The subject reported that her tinnitus occurred primarily in her right ear, which had linked, quasi-stable spontaneous otoacoustic emissions not found contralaterally. During one menstrual cycle, a pure tone was adjusted to match the predominant tinnitus pitch. The frequency of the tone generally followed the day-to-day shifts in the frequency of the associated spontaneous otoacoustic emission. The frequencies of these tones were a local minimum near the onset of menstruation, reaching a local maximum after menstruation.

Le Journal de Physique IV · 1994

Système efférent, masquage central et perception dans le bruit (opens in a new tab)

C. MICHEYL, L. COLLET

Abstract

In order to investigate the role of the auditory efferents in perception, the controlateral suppression of evoked otoacoustic emissions (EOAEs) was examined together with 1) central masking and 2) detection in noise in normal hearing subjects. The first study, concerning the relations between the contralateral suppression of EOAEs and central masking at 1 kHz, put into evidence the existence of a significant negative correlation between the amount of central masking obtained with a delay of 20 ms between the test and the mask and the modifications of the amplitude of EOAEs induced around 1 kHz by a contralateral 30 dBSL broadband noise stimulation. In the second study, a correlation was found between the mean equivalent attenuation of EOAEs and the variation of the tone-in-noise detection threshold, both induced by a contralateral 30 dBSL broadband noise stimulation. These results support the hypothesis that the crossed part of the medial olivo-cochlear system is actually involved in auditory perception in humans.